POWER DISTRIBUTION SCHEME OF NWPL01 PANEL
FEEDER-1 240V AC SUPPLY FEEDER-1 240V AC SUPPLY
MTB-1 1 2 3 4 5 MTB-1 1 2 3 4 5

1 3 1 3 1 3 1 3
MCB1 MCB2 MCB3 MCB4
32 A 2 4 2 4
32 A 32 A 2 4 2 4
32 A ITEMS SUPPLIED LOOSE WITH THE PANEL,
2 2
DSF
1 1
DSR
IN-1 IN-2 IN-1 IN-2 TO BE MOUNTED AT SITE.
STATIC SWITCH-1 STATIC SWITCH-2
OUT OUT

DCS-TB 1 2 3 4
1 3 1 3

CB01 CB02
TO DCS 32 A 32 A
2 4 2 4
TO MONITOR DOOR OPEN/CLOSE
STATUS ON HMI THROUGH DCS

X1 01 02 03 04 05 06 07 08 X2 01 02 03 04 05 06 07 08
X3 01 02 03 04 05 06 07 08 X4 01 02 03 04 05 06 07 08

1 3

MCB-L
6A
2 4

DTB-N
1 2 3 4 5 TOP TOP 1 2 3 4 5
1 2 3 4 5 BOT BOT 1 2 3 4 5

DTB-L
FAN

1 4

1MCB10-A

1MCB10-B
1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3

1MCB1-C

1MCB2-C

1MCB3-C

1MCB4-C

1MCB1-D

1MCB2-D

1MCB3-D

1MCB4-D

1MCB5-D
1MCB1-A

1MCB2-A

1MCB3-A

1MCB4-A

1MCB5-A

1MCB6-A

1MCB7-A

1MCB8-A

1MCB9-A

1MCB1-B

1MCB2-B

1MCB3-B

1MCB4-B

1MCB5-B

1MCB6-B

1MCB7-B

1MCB8-B

1MCB9-B
2A 2A 2A 2A 6A 6A 6A 6A 6A 6A 6A 6A 6A 6A 2A 2A 2A 2A 6A 6A 6A 6A 6A 6A 6A 6A 6A 6A 6A
1 1
DS1 DS2
2 2 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4

1 1 1
PS 2 5
L1 L2 DTB-A 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 DTB-C 01 02 03 04 05 06 07 08 09 10 11 12 DTB-B 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 DTB-D 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15

(FRONT) 2 2 (REAR) 3 4

1MBGW-PS
1OWS1

1OWS2

1OWS3

1STOR1

1OWS4

1OWS5

1OWS6

1STOR2
1HMI1-A

1DCSSW-1

LJP B/WA4-1

LJP B/WA4-2

1HMI1-B

LJP B/WA4-3

LJP B/WA4-4
LINK1

LINK2
1ENG1

CONSOLE

1ENG2
SECURITY SERVER
1DCS1-A

1DCS2-A

1U/IC PC

1DCS1-B

1DCS2-B

SPARE

SPARE

UTM
LEGEND : NOTE

MTB : MAIN TERMINAL BLOCK 1. CB01, CB02 ARE 240, 63A, 2P


DBK : DISTRIBUTION BLOCK 2. MCB1-A TO MCB4-A, MCB1-B TO MCB4-B ARE 240, 2A, 2P
DTB : DISTRIBUTION TERMINAL BLOCK 3. MCB5-A TO MCB10-A ARE 240, 6A, 2P
PS : POWER SOCKET 4. MCB5-B TO MCB10-B ARE 240, 6A, 2P
L1, L2 : LAMP1, LAMP2 5. MCB1-C TO MCB4-C ARE 240, 6A, 2P
DSF : DOOR SWITCH FRONT 6. MCB1-D TO MCB5-D ARE 240, 6A, 2P
DSR : DOOR SWITCH REAR
7. MCB-L IS 240V, 6A, DOUBLE POLE.
MBGW : MODBUS GATEWAY 8. CABLE SIZE AS PER EDN STANDARD ED0233199.

CE/1911-SH1-80-01
FIRST ANGLE PROJECTION (ALL DIMENSIONS ARE IN mm)

NOT BE USED DIRECTLY OR INDIRECTLY IN ANY WAY DETRIMENTAL TO THE INTEREST OF THE COMPANY.
THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF BHARAT HEAVY ELECTRICALS LTD. IT MUST

V1- V1+ E
V1+ V1-
1MBGW-1
1MBGW-PS C1 C2 C3 C4

RX+ TX- TX+ RX+ TX- TX+ RX+ TX- TX+ RX+ TX- TX+
GND RX- TX D- D+RX GND RX- TX D- D+RX GND RX- TX D- D+RX GND RX- TX D- D+RX
L N E
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5

10 11 12
TO DTB-D
DTB-E 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

V1- V1+ E
V2+ V2-
1MBGW-2
1MBGW-PS C1 C2 C3 C4

RX+ TX- TX+ RX+ TX- TX+ RX+ TX- TX+ RX+ TX- TX+
GND RX- TX D- D+RX GND RX- TX D- D+RX GND RX- TX D- D+RX GND RX- TX D- D+RX
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5

DTB-F 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

CE/1911-SH1-80-01