2 Storeyed RCC Building (8.5.2023) Structure

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

1 2 2' 3 4 5

60'-0"
6'-3" 19'-0" 19'-0" 15'-9"

7'-0"
15"
6'-416
15"
4'-616
2'-683"
1'-0"

1'-0"
1'-0"

1'-0"
B

6"

1'-6"

1'-0"
1'-0"

C1

1'-6"
C2 C1

1'-6"
C2 C1

27'-0"
3'-6" 3'-6"

SB1
3'-6"
OWNER / APPLICANT
20'-0"
18'-0"

18'-0"
19'-6"

19'-6"

19'-6"
16'-9"
17'-0"

18'-0"
19'-0"

17'-0"

18'-0"

17'-0"

18'-0"

18'-0"
SB1

SB1

SB1
SB1

7'-0"
A' C1
C1 C1
3'-6" F1
7'-0"
SF1 SF2 SF2 SF3
PROJECT PROPOSED (2 )STOREYED
1'-0"

1'-0"

1'-0"
C2
1'-0"

C2 C1 R.C.C BUILDING

1'-0"
C1 C1
6"

6"
6"
6"
6"

6"
1'-6" 2'-0" 5'-6" 2'-3" BOUNDARY LINE 2'-3" 2'-3" 3"
3'-6" 3'-6" 3'-6" 3'-6"
6"

10'-0" 7'-0" 7'-0" 4'-6"


BLOCK NO.
3'-0" 60'-0" 2'-0"
65'-0"
NOTE: SOIL BEARING CAPACITY IS 0.8 TSF. SF1= 10'-0" x 19'-0" x 0'-16" SB1= 14"x24" LOT NO.
FOUNDATION PLAN SF2= 7'-0" x 19'-6" x 0'-16"
(-6'-0" LV FROM NGL) SF3= 4'-6" x 19'-6" x 0'-12"
F1= 7'-0" x 7'-0" x 0'-12"

SUBJECT
1 2 2' 3 4 5 FOUNDATION & COLUMN LAYOUT PLAN

60'-0"
6'-3" 9'-6" 9'-6" 19'-0" 15'-9"
1 IN : 7 FT SHEET-NO.
1'-0"

1'-0"

1'-0"

1'-0"

1'-0"
6" 6" 6" 6" 6"
B
6"

6"

6"

6"

6"
C2 S-01
1'-0" C2 1'-0" C1 1'-0" C1 1'-0" C1 1'-0" 8.5.2023
9'-0"

R.S.E/Construction
1'-0"

1'-0"

1'-0"
6" 6" 6"
18'-0"

6"

6"

6"
A' C1
C1 1'-0" C1 1'-0" 1'-0"
9'-0"

C1= 12"x12"
1'-0"

1'-0"

1'-0"

1'-0"

1'-0"

6" 6" 6" 6" 6" C2= 12"x12"


6"

6"

6"

6"

6"

A C2
1'-0" C2 1'-0" C1 1'-0" C1 1'-0" C1 1'-0"
GROUND ,FIRST FLOOR COLUMN LAYOUT PLAN f 'c =3000 psi(C25)
(+1'-6" , 12'-6" LEVEL) f y =50000 psi
(HRB-400)
1 2 2' 3 4 5
60'-0"
6'-3" 9'-6" 9'-6" 19'-0" 15'-9"

1'-0"

1'-0"
6" 6"
B

6"

6"
C2 C2 C1 C1 C1
1'-0" 1'-0"

9'-0"
18'-0"

A' C1 C1 C1
9'-0"
1'-0"

1'-0"

6" 6" C1= 12"x12"


C2= 12"x12"
6"

6"
OWNER / APPLICANT
A C2
1'-0"C2 1'-0" C1 C1 C1
C1 Column End At This Level. ROOF FLOOR COLUMN LAYOUT PLAN
(+21'-6" LEVEL)
1 2 2' 3 4 5
60'-0"
6'-3" 9'-6" 9'-6" 19'-0" 15'-9" PROJECT PROPOSED (2 )STOREYED
B C2
R.C.C BUILDING
C2
9'-0"

BLOCK NO.
18'-0"

LOT NO.
A'
9'-0"

SUBJECT FOUNDATION & COLUMN LAYOUT PLAN


C2= 12"x12"
A C2 C2
TOP ROOF FLOOR COLUMN LAYOUT PLAN
C2 Column End At This Level. (+30'-6" LEVEL)
1 IN : 7 FT SHEET-NO.
1 2 2' 3 4 5
60'-0" S-02
6'-3" 9'-6" 9'-6" 19'-0" 15'-9" 8.5.2023
B
R.S.E/Construction
9'-0"
18'-0"

A'
9'-0"

f 'c =3000 psi(C25)


A *All Retaining Wall Are 9"thk. RETAINING WALL PLAN f y =50000 psi
(HRB-400)
1 2 2' 3 4 5
60'-0"
6'-3" 9'-6" 9'-6" 19'-0" 15'-9"
1

GB3 GB3 GB3 GB3


B

4'-0"
GB1 GB1 GB1
9'-0"

GB2
GB3

GB3
12'-0"

GB3
CP1 GB2 GB2
18'-0"

GB2
GB3

GB3
A'
GB1

GB2

GB3
9'-0"

CP1
OWNER / APPLICANT
GB3

A GB3 GB3 GB3 GB3


1
9"x9" RC Prop(CP1) Start From This Level.
GROUND FLOOR BEAM PLAN GB1= 9"x9"
GB2= 9"x14" PROJECT PROPOSED (2 )STOREYED
(+1'-6" LEVEL) GB3= 12"x16" R.C.C BUILDING

BLOCK NO.

1 2 2' 3 4 5
LOT NO.
60'-0"
6'-3" 9'-6" 9'-6" 19'-0" 15'-9" 2'-6"

FB2 FB2 FB2 FB2 FB2


FB3A

FB3A
FB3A

FB3A
FB3A
3'-0"

SUBJECT

FB2
GROUND & FIRST FLOOR BEAM PLAN
S1 S1 S1 S1 S1
FB3 FB3 FB3 FB3
B
4'-712"

FB3A
S2
FB1
9'-0"

FB2
FB4

FB3
S1 S2 S1
FB4

VOID 1 IN : 7 FT SHEET-NO.
12'-0"

4'-412"

S2
FB1

CP1 FB4 FB4 S-03


18'-0"

FB2A

FB2A
S2 S2 S2 8.5.2023
FB3

FB3
S1
A' FB3A
FB3
4'-412"

S3
FB1

FB1 R.S.E/Construction
FB1 S2

FB2
FB4
9'-0"

S1 S1

FB3
CP1
FB4

S3
4'-712"

S2

A FB3 FB3 FB3 FB3 FB3A


6'-6" 3'-0" 9'-6" 12'-6" 11'-3"
9"x9" RC Prop(CP1) Start From This Level. FB1= 9"x9"
FIRST FLOOR BEAM PLAN FB2= 9"x16"
FB2A= 9"x16"
(+12'-6" LEVEL) FB3= 12"x16"
f 'c =3000 psi(C25)
FB3A= 12"x16"
FB4= 12"x12" f y =50000 psi
(HRB-400)
1 2 2' 3 4 5
60'-0" 2'-6"
6'-3" 9'-6" 9'-6" 19'-0" 15'-9"

RB2 RB2 RB2 RB2 RB2

RB3A
RB3A

RB3A
RB3A

RB3A
3'-0"

RB2
S1 S1 S1 S1 S1
RB3 RB3 RB3 RB3
B
RB3A
9'-0"

RB4

RB3

RB2
S2 S2 S1

RB4
VOID
12'-0"

RB4 RB4
18'-0"

RB2

RB2
S2 S2 S2 S2
RB3

RB3
A' RB3A

RB3
RB1
OWNER / APPLICANT

RB3
RB4

RB2
S2 S2
9'-0"

S1
RB4

S2

A RB3 RB3 RB3 RB3 RB3A


9'-6" 9'-6" 8'-112"
PROJECT PROPOSED (2 )STOREYED
C1 COLUMN END AT This Level.
RB1= 9"x9" R.C.C BUILDING
ROOF FLOOR BEAM PLAN RB2= 9"x16"
(+21'-6" LEVEL) RB3= 12"x16"
RB3A= 12"x16" BLOCK NO.
RB4= 12"x12"

LOT NO.
1 2 2' 3 4 5
60'-0"
6'-3" 9'-6" 9'-6" 19'-0" 15'-9"

SUBJECT ROOF & TOP ROOF FLOOR BEAM PLAN


TRB1
B

1 IN : 7 FT SHEET-NO.

S-04
18'-0"

S1
TRB1

TRB1

8.5.2023
A'
R.S.E/Construction

A TRB1

TOP ROOF FLOOR BEAM PLAN


TRB1= 9"x16"
(+30'-6" LEVEL)

f 'c =3000 psi(C25)


f y =50000 psi
(HRB-400)
FOUNDATION SCHEDULE

SIZE REINFORCEMENT
TYPE TOP BAR BOTTOM BAR REMARK
L B H
SHORT DIRECTION LONG DIRECTION SHORT DIRECTION LONG DIRECTION

SF1 10'-0" 19'-0" 0'-16" STRIP


FOOTING
SF2 7'-0" 19'-6" 0'-16" STRIP
FOOTING
SF3 4'-6" 19'-6" 0'-12" STRIP
FOOTING
F1 7'-0" 7'-0" 0'-12" - - ISOLATED
FOOTING
NOTE: SOIL BEARING CAPACITY IS0.8 TSF.

STRIP BEAM SCHEDULE

MAIN REINFORCEMENT
SIDE BAR STIRRUP REMARK
TYPE END SPAN(LEFT) MID SPAN END SPAN(RIGHT) OWNER / APPLICANT
SIZE OR
TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2h MID SPAN

SB1 14"x24" - STRIP BEAM

PROJECT PROPOSED (2 )STOREYED


R.C.C BUILDING

Ground Floor Slab = 4" Thk; Ground Floor Slab = 4" Thk;
3" thk; (1:3:6:)Lean Concrete 3" thk; (1:3:6:)Lean Concrete
BLOCK NO.
11" thk; Hard Core 11" thk; Hard Core
GROUND FL(+1'-6"LV) GB GROUND FL(+1'-6"LV) GB GB GB
1'-6"

LOT NO.
5'-0"

9"
2'-9"

9" Thk; Retaining Wall 9" Thk; Retaining Wall 9" Thk; Retaining Wall
3"
6"

3" Thk; (1:3:6)Lean Conc;


6" Thk; Hard Core SUBJECT STRUCTURAL SCHEDULE
1'-112"
9"

1'-6" SECTION 1-1


2'-6"
2'
9" Thk; RETAINING WALL DETAIL 1 IN : 4 FT SHEET-NO.

GROUND FL(+1'-6"LV) S-05


8.5.2023
1'-6"

GB2
R.S.E/Construction
C1
7'-6"
6'-0"

12"

3" Thk; (1:3:6)Lean Conc;


12" Thk; Hard Core
7'-0"
(F1) ISOLATE SQUARE FOOTING SECTION AT GRID-A'
NOTE: SOIL BEARING CAPACITY IS 0.8 TSF.
A B
6" 18'-0" 1'-0"

GROUND FL(+1'-6"LV)
1'-6"
GB3 GB3 GB3
7'-6"
6'-0"

C1 C1
OWNER / APPLICANT

SB1(12"x24")
SF2
2'-0"
1'-4"

Ld Ld
3" Thk; (1:3:6)Lean Conc;
12" Thk; Hard Core PROJECT PROPOSED (2 )STOREYED
R.C.C BUILDING
1'-0" 17'-0" 1'-6"
19'-6"
BLOCK NO.
SF2 STRIP FOOTING SECTION GRID LINE-3
NOTE: SOIL BEARING CAPACITY IS 0.8 TSF.
LOT NO.

SUBJECT STRUCTURAL SCHEDULE

1'-6"
GROUND FL(+1'-6"LV)
GB3 GB3

1 IN : 4 FT SHEET-NO.

C1 S-06
7'-6"
6'-0" 8.5.2023

R.S.E/Construction
SB1(12"x24")
SF1
2'-0"
1'-4"

Ld
3" Thk; (1:3:6)Lean Conc;
12" Thk; Hard Core

3'-6" 3'-6"
7'-0"

SF2 STRIP FOOTING SECTION GRID LINE-B


NOTE: SOIL BEARING CAPACITY IS 0.8 TSF.
FOUNDATION TO GROUND FLOOR TO ROOF FLOOR TO
COLUMN TYPE REMARK
GROUND FLOOR ROOF FLOOR TOP ROOF FLOOR

12" 12"
SIZE

12"

12"
C1 &
DETAIL

MAIN STEEL

TIES
(clear Spacing) (clear Spacing) OWNER / APPLICANT

12" 12" 12"


SIZE
12"

12"

12"
C2 &
DETAIL PROJECT PROPOSED (2 )STOREYED
R.C.C BUILDING

MAIN STEEL
BLOCK NO.

TIES LOT NO.


(clear Spacing) (clear Spacing) (clear Spacing)

9" NOTE : 9"x9" RC PROP COLUMN


SIZE
FLOOR BEAM TO LANDING LEVEL
9"

CP1 & SUBJECT STRUCTURAL SCHEDULE


DETAIL

MAIN STEEL 1 IN : 4 FT SHEET-NO.

TIES S-07
8.5.2023
(clear Spacing)
R.S.E/Construction
GROUND FLOOR BEAM SCHEDULE

MAIN REINFORCEMENT
SIDE BAR STIRRUP
TYPE END SPAN(LEFT) MID SPAN END SPAN(RIGHT)
SIZE OR REMARK
TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2h MID SPAN

GB1 9"x9" - GROUND


FLOOR
GB2 9"x14" - LEVEL
GB3 12"x16" -

FIRST FLOOR BEAM SCHEDULE

MAIN REINFORCEMENT
SIDE BAR STIRRUP
TYPE END SPAN(LEFT) MID SPAN END SPAN(RIGHT)
SIZE OR REMARK
TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2h MID SPAN

FB1 9"x9" - FIRST


OWNER / APPLICANT
FLOOR
FB2 9"x16" - LEVEL
FB2A 9"x16" -

FB3 12"x16" + + + -

FB3A 12"x16" - PROJECT PROPOSED (2 )STOREYED


FB4 12"x12" R.C.C BUILDING
-

ROOF FLOOR BEAM SCHEDULE BLOCK NO.

MAIN REINFORCEMENT
SIDE BAR STIRRUP LOT NO.
TYPE END SPAN(LEFT) MID SPAN END SPAN(RIGHT)
SIZE OR REMARK
TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2h MID SPAN

RB1 9"x9" - ROOF


FLOOR
RB2 9"x16" - LEVEL
SUBJECT STRUCTURAL SCHEDULE
RB3 12"x16" -
RB3A 12"x16" -
RB4 12"x12" -
1 IN : 4 FT SHEET-NO.

TOP ROOF FLOOR BEAM SCHEDULE S-08


8.5.2023
MAIN REINFORCEMENT
SIDE BAR STIRRUP REMARK
TYPE SIZE END SPAN(LEFT) MID SPAN END SPAN(RIGHT) R.S.E/Construction
OR
TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2h MID SPAN
TOP ROOF
TRB1 9"x16" FLOOR
-
LEVEL
SLAB STEEL SCHEDULE

SHORTER DIRECTION LONGER DIRECTION DISTRIBUTION


TYPE THICKNESS LAYER STEEL REMARK
Discont; Mid Span Cont; Discont; Mid Span Cont;

TOP - - -
S1 4" ONE WAY
BOTTOM - - -
TOP -
S2 4" TWO WAY
BOTTOM -
TOP -
S3 5" TWO WAY
BOTTOM -

1 2
STAIR STEEL SCHEDULE
6'-0"
LB1 C1
TYPE THICKNESS
REINFORCEMENT
REMARK CP1 OWNER / APPLICANT

3'-3"
LB1

LB1
MAIN STEEL DIST; STEEL
MAIN STAIR /LS1
LS1
5" GB TO RB
CP1 CP1
LB1

5'-6"
PROJECT
B PROPOSED (2 )STOREYED
R.C.C BUILDING
3'-0" 9'-0"
A BLOCK NO.

9"x9" RC Prop(CP1)End At This Level.


LOT NO.
6"
1'-6" 1'- LB1= 9"x9"
FIRST FLOOR(+12'-6"LV)
5"

LANDING BEAM PLAN


Tread =10.6875" FB
Riser = 6.625" (+7'-0",18'-0" LEVEL)
SUBJECT STRUCTURAL SCHEDULE
Waist =5"

6"
1'-
5"

1'-6" (Dist; Steel)


11'-0"

LB
1 IN : 4 FT SHEET-NO.
LB LB (Main Steel) 9"
S-09
5'-6"

9"x9" RC Prop(CP1) 8.5.2023

9"
5"

Tread =12"
R.S.E/Construction
Riser = 6.625"
GROUND FLOOR(+1'-6"LV) Waist =5" GB
1'-6"

LB1 SECTION