RO SYSTEM

1 Technical data
Model MO-36000 Table 2. Limitations***
Product Code M36VCTFW 150 mg/l CaCO3
Rated capacity, LPH* 1500 Hardness
8 °dH
Membranes 6 × XLE-4040
Iron 0,1 mg/l
Inlet pressure, bar 2—6
Consumption of water Manganese 0,05 mg/l
90–110
per membrane flush, L Silica 20 mg/l
Power consumption, Total dissolved solids 3000 mg/l
1,9
kW
Chemical Oxygen Demand 4,0 mg/l O2
Dimensions 700 × 600 ×
(W × D × H), mm 1500 Residual Chlorine 0,1 mg/l
Maximum weight (dry), Hydrogen Sulfide None
120
kg ***
The limitations may be exceeded if using
Connection port sizes: antiscalant, oxygen scavenger, or other RO chemical
• feed water 1″ pretreatment.
• permeate 1″
Temperature of water 10…25 °C
• concentrate 1″
Electrical power 230 V, 50 Hz
Operating specification
Operating pressure 0,8…1,2 MPa
Recycle flow rate:
• LPM 30–52
• LPH 1800–3100
Drain flow rate:
• LPM 8–12
• LPH 480–720
Permeate flow rate:
• LPM 24–30
• LPH 1400-1800
ANN E X A
Ecosoft MO36000 piping and instrumentation diagram

Figure 3. Ecosoft МО-36000 RO system diagram

You might also like