Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Increase accuracy while

saving time in water analysis

Whatman
Ready-to-use
filter family

Maintaining accuracy under the time pressure


of a busy lab can be a challenge. The WhatmanTM
ready-to-use (RTU) filter family from Cytiva are
certified to have been pre-treated in line with key
requirements for sample preparation, helping you
to support an accurate analysis while reducing time
spent on sample preparation.
Filter preparation workflows
EN872

Blank assessment × 3 filters

Dry at 105°C and cool Dry at 105°C and cool Is weight loss
in “balance” Filter water ‘blank’ in “balance” < 0.017 mg/cm2?
atmosphere and weigh atmosphere and weigh
Blank assessment × 3 filters

Dry at 105°C and cool Prewash/soak


Dry at 105°C and filters
cool NO
Is weight loss
in “balance” Filter water ‘blank’ in “balance” < 0.017 mg/cm2?
atmosphere and weigh atmosphere and weigh

Filter preparation
Prewash/soak filters NO

Filter preparation

Wash filter
Standard Method 2540 Dry Cool/desiccate Weigh Dry Cool/desicca
Wash filter Dry Cool/desiccate Weigh Dry Cool/desiccate Weigh

Or fire at 550°C Or fire at 550°C


Or fire at 550°Cif for Volatiles Or fire at 550°C if for Volatiles
if for Volatiles if for Volatiles

934-AH™ RTU for


suspended and 934-AH RTU 934-AH RTU
GF/C™ RTU dissolved solids for volatiles double weigh
Pre-washed, dried, cooled, and weighed • • • •
Barcoded aluminum pans to download filter weight • • • •
Box barcoded to download weights of all
filters contained • • • •
Pre-fired at 550ºC •
Drying and weighing steps repeated and documented twice
to conform to process in US EPA Lab Standard Method 2540
parts C and D

Certified filter mass loss the lesser of 0.5 mg
or 4% after Standard Method 2540 parts
C and D preparatory workflow
• • •
Certified mass loss of less than 0.017 mg/cm2 after
EN 872 preparatory workflow •
Economy option available (washed and dried without
weighing or barcoding) • • •
Ordering information
Standard (non-RTU) glass microfiber filters RTU for volatile analysis
Description Diameter (mm) Product code Description Diameter (mm) Product code
934-AH (1.5 µm retention efficiency) 42.5 1827-042 934-AH 35 3827-035

47 1827-047 42.5 3827-042

55 1827-055 47 3827-047

70 1827-070 70 3827-070
90 3827-090
90 1827-090
934-AH RTU for 35 4827-035
GF/C (1.2 µm retention efficiency) 42.5 1822-042
volatiles economy
42.5 4827-042
47 1822-047 (not weighed)
47 4827-047
55 1822-055
70 4827-070
70 1822-070
90 4827-090
90 1822-090

RTU double weigh


RTU for dissolved and suspended solids
934-AH RTU 47 9927-047
934-AH RTU for dissolved and suspended solids 42.5 9907-042 double weigh
47 9907-047 70 9927-070
55 9907-055 90 9927-090
70 9907-070
90 9907-090
934-AH RTU economy (non-weighed) 47 2827-047
934-AH RTU weighed to 5 decimal places 47 9907-9436
GF/C RTU for dissolved and suspended solids 47 3822-047
70 3822-070
90 3822-090
GF/C RTU economy (not weighed) 47 2822-047
70 2822-070
Download certified filter weights here:
90 2822-090
cytiva.com/documents/RTU

cytiva.com/whatman
Cytiva and the Drop logo are trademarks of Global Life Sciences IP Holdco LLC or an affiliate.
934-AH, GF/C, and Whatman are trademarks of Global Life Sciences Solutions USA LLC or an affiliate
doing business as Cytiva.
© 2020 Cytiva
For local office contact information, visit cytiva.com/contact

CY14033-17Aug20-FL

You might also like