What is Pump Head and Shut-off Head?

One of the most misunderstood physical characteristics of a pump is the concept of


head. It’s related to pressure, but how, exactly?

This article will demystify the term “head” as it relates to pumps, so you should
never have to worry again about what head is, how it relates to pressure or why it’s
important.

It’s a concept that’s actually incredibly simple to define, but can be confusing
when the concept is translated into examples involving real pumps. Imagine a
pump where you have a pipe that extends straight up vertically from the
discharge (see Figure 1).
Figure 1: Imaginary vertical discharge pipe used to measure head.

Simply stated: a pump’s head is the maximum height that the pump can achieve
pumping against gravity. Intuitively, if a pump can produce more pressure, it can
pump water higher and produce a higher head. Also note that the higher the liquid
in the tank, the higher the pump will be able to pump the water into the vertical
discharge pipe, due to the head exerted by the liquid in the suction tank (see Figure
2).
Figure 2: Head depends on the pump itself and the height of the liquid in the suction tank.

A much more useful measure of head is the difference between the liquid level in
the suction tank and the head in the vertical discharge pipe. This number is known
as the “total head” that the pump can produce.
Increasing the level of the liquid in the suction tank will give rise to increased
head, and decreasing the level will give rise to a lower head. Pump manufacturers
and suppliers often won’t tell you how much head a pump can produce, because
they can’t predict what the height of the liquid in your suction tank will be. Instead,
they will report the pump’s total head, the difference in height between the level of
liquid in the suction tank and the height of a column of water that the pump can
achieve. Total head is independent of the level of liquid in the suction tank.
Figure 3: Total head is independent of the suction head.

Note that now that we’ve defined total head, we can translate these useful
relationships into equations:

Ht = Hd – Hs

Where Ht is the total head, Hd is the discharge head and Hs is the suction head.
Also be aware that this equation holds true whether the suction head is positive
(level of liquid in the suction tank is above the pump) or negative (level of the
liquid in the suction tank is below the pump). See Figure 4 for an example of the
latter situation. In this case, the pump will still produce the same total head, but
because the suction head is negative, the discharge head will be reduced by this
amount, according to our equation.

Figure 4: Example of how a negative suction head affects the discharge head.

In Figure 5 a pump is transferring liquid from the suction tank into a vertical pipe
where the liquid rises until it can’t overcome the force of gravity and it quits rising.
In this situation, the flow of the pump is zero. The pump is working, but the force
of gravity causes the water’s rise in the vertical discharge pipe to stop and the net
flow stops. This is known as the “shut-off head”, it’s the amount of head a pump
can produce at zero flow.
To choose your required pump, you need to know two things: the total head and
what flow rate you require. As you might expect, these two quantities are related.
The maximum head (shut-off head) is achieved at a flow rate of zero. Increasing
flow rate introduces friction into the system as the liquid travels along the pipes
from the suction tank to the pump and from the pump into the discharge pipe. This
friction reduces the amount of total head that the pump can produce. In fact, as the
flow increases, friction increases and the total head continues to decrease. The
amount of head that is lost due to friction is called “friction head” or “friction-
loss” (see Figure 5 and Figure 6).

Figure 5: Relationship between total head, shut-off head, discharge head and suction head in a pump with
no flow.
Figure 6: Relationship between total head, shut-off head, discharge head and suction head in a pump with
no flow.

In a system where there is flow, the total head is the difference between the
discharge head and the suction head plus the friction head and this sum will be less
than the shut-off head. The plot of head versus flow rate is known as the pump’s
performance curve (see Figure 7 for an example of a pump performance curve).
Figure 7: Pump performance curve of total head versus flow.

Every centrifugal pump will be supplied with a performance curve plotting head
versus flow rate. The required flow rate and total head will intersect at a certain
point on the pump’s performance curve and comparing this to the pump’s curve
will allow you to determine whether that particular pump will be appropriate (i.e.
will it produce enough head at the required flow rate?) for your needs.

Why is head used as a measure of a pump’s ability to pump liquids rather than
pressure? Historically, many pumps were used to pump water uphill to a higher
level – for example into a storage tank at the top of a hill. If you have to pump
water to a height of 60 metres to get it up the hill, then using head – measured in
metres – is natural. You automatically know that if a pump doesn’t have 60 metres
of head, it’s not appropriate for your application.

Another reason that head is used, is that as long as the liquid that is being pumped
has a similar viscosity to water, the head will be identical for different liquids. This
may or may not be the case when using pressure to define a pump’s characteristics.
Although some pump manufacturers do use pressure to characterise their pumps,
the vast majority of pumps are still characterised by the total head they produce.
We hope you found this blog post helpful. Head to our blog page to learn more
about how to reduce friction in suction/discharge lines or how to check flow and
head pressure.

Global Pumps are a leading Australian industrial pump supplier for mining,
government, wine, food, beverage, chemical processing, paint, print, packaging
and manufacturing industries. We stock an extensive range of pumps and spares in
Australia and deliver anywhere in the world.

Our pump engineers and sales consultants are available to help you to select the
right pump or system to suit your specific industry application needs, to achieve
efficiencies, increased productivity and reduced downtime. Contact us today to
talk to one of our friendly pump experts about what type of industrial pump you
need for your specific industry application.

You might also like