Data sheet

Customer item no.:CWTP-C06-B2-01


Communication dated: 22/04/2021 Number: ES 8001117310
Doc. no.: 1 Item no.: 100
Quantity: 3 Date: 22/04/2021
Page: 1 / 7

Omega 125-365 A GC G F Version no.: 1

228.50/3.6=63.47 L/s
Operating data
Requested flow rate 228.50 m³/h Actual flow rate 228.5 m³/h
Requested developed head 42.50 m Actual developed head 42.5 m
Pumped medium Water Efficiency 80.4 %
Clean water Power absorbed 32.80 kW
Not containing chemical and Pump speed of rotation 1480 rpm
mechanical substances which NPSH required 2.72 m
affect the materials NPSH 3% 2.22 m
Max. ambient air temperature 50.0 °C Discharge press. 4.16 bar.g
Min. ambient air temperature 20.0 °C
Fluid temperature 80.0 °C

Fluid density 998 kg/m³ Operating pressure (for 4.67 bar.g


Fluid viscosity 1.00 mm²/s indicated duty conditions)
Suction pressure max. 0.00 bar.g Min. allow. mass flow for 23.94 kg/s
Mass flow rate 63.33 kg/s continuous stable operation
Max. power on curve 48.20 kW Shutoff head 47.74 m
Min. allow. flow for continuous 86.36 m³/h Max. allow. mass flow 112.26 kg/s
stable operation Design Single system 1 x 100 %

Design 86.36/3.6=23.98 L/s


Pump standard KSB axially split volute casing Minimum impeller diameter 289.0 mm
pump Full impeller diameter 385.0 mm
Design Pump and motor on common Free passage size 14.0 mm
Baseframe (3E) Direction of rotation from drive Clockwise
Pressure Rating PN16 Bearing seal driver side Lip seal
Enhanced Finish No Bearing type driver side Anti-friction bearings
Suction flange (AS) EN 1092-2 / DN 200 / PN 16 Lubrication type driver side Grease
drilling+seal face according to 21A / FF Bearing sealing end side Lip seal
Discharge flange (AD) EN 1092-2 / DN 125 / PN 16 Bearing type end side Anti-friction bearings
drilling+seal face according to 21A / FF Bearing lubrication end side Grease
Shaft seal Single acting mechanical seal Temperature measurement With
Manufacturer John Crane/ Burgmman tapping
Type 4OM Temperature sensor PT100 Without
Mechanical Seal Form Balanced motor side
Material code Q2Q2VGG Vibration measurement With
Sealing plan E Single acting mechanical tapping
(external circulation) Color Ultramarine blue (RAL 5002)
Wear ring Casing wear ring KSB-blue
Wear ring type Standard design
Impeller diameter 350.0 mm

Percentage of recommended minimum flow = 23.98/63.47=37.78 %