Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: ISTER
Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3000 Wp

PVsyst TRIAL
Hacienda San Sebastián - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: ISTER
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:37

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
Hacienda San Sebastián Latitude -0.34 °S Albedo 0.20
Ecuador Longitude -78.44 °W
Altitude 2528 m
Time zone UTC-5

Meteo data
La Colina
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 30 units Technology Lead-acid, vented, tubular
Pnom total 3000 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3657.91 kWh/year
Missing Energy
Excess (unused)
73.85 kWh/year
1293.65 kWh/year

Project and results summary


Specific production 1219 kWh/kWp/year Perf. Ratio PR
Available solar energy 5133.56 kWh/year

Table of contents
Solar Fraction SF
61.45 %
98.02 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: ISTER
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:37

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 30 units Discharging min. SOC 20.0 %
Nominal (STC) 3000 Wp Stored energy 20.9 kWh
Modules 10 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2813 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 42 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.4 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 3.00 kWp
Total 30 modules
Module area 18.3 m²
Cell area 15.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
25 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: ISTER
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:37

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1 1 2200/lamp 3.0 6600
CARGA2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: ISTER
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:37

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3657.91 kWh/year Perf. Ratio PR 61.45 %
Available solar energy 5133.56 kWh/year Solar Fraction SF 98.02 %
Excess (unused) 1293.65 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 2.3 % Cycles SOW 91.6 %
Missing Energy 73.85 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
180.6
140.4
164.4
159.7
GlobEff
kWh/m²
151.4
125.1
154.2
160.0
E_Avail
kWh
410.3
336.9
411.0
427.4
EUnused
kWh
86.5
48.0
90.6
110.2
E_Miss
kWh
15.64
5.10
0.62
23.42
E_User
kWh
301.3
281.2
316.3
283.3
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
0.951
0.982
0.998
0.924
May 172.5 180.7 483.1 153.7 0.00 316.9 316.9 1.000
June 170.2 183.4 490.6 167.0 0.00 306.7 306.7 1.000
July 181.8 194.2 520.4 188.9 0.00 316.9 316.9 1.000
August 192.5 197.3 521.2 187.8 0.00 316.9 316.9 1.000
September 169.8 163.3 437.9 119.1 0.00 306.7 306.7 1.000
October 157.4 142.9 379.8 64.1 3.33 313.6 316.9 0.989
November 147.8 127.2 340.1 34.1 19.49 287.2 306.7 0.936

PVsyst TRIAL
December 166.5 138.7 374.8 43.7 6.24 310.7 316.9 0.980
Year 2003.6 1918.6 5133.6 1293.7 73.85 3657.9 3731.8 0.980

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: ISTER
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:37

PVsyst TRIAL
with v7.4.0

Loss diagram
2004 kWh/m² Global horizontal irradiation

-0.96% Global incident in coll. plane

-3.31% IAM factor on global

1919 kWh/m² * 18 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

5759 kWh Array nominal energy (at STC effic.)


-0.58% PV loss due to irradiance level

PVsyst TRIAL -4.59%

+1.25%

-1.15%

-2.09%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-24.17% Unused energy (battery full)

4022 kWh Effective energy at the output of the array

-3.99% Converter Loss during operation (efficiency)

PVsyst TRIAL
Missing Direct use
3840 kWh
Stored
-1.13%
-0.07%
0.00%
0.00%
Converter Loss over nominal conv. power
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
Converter losses (effic, overload)
Battery Storage
energy 22.4% 77.6%
-0.10% Battery Stored Energy balance
1.98%
-3.63% Battery efficiency loss
73.8 kWh
-2.22% Charge/Disch. Current Efficiency Loss
-0.15% Gassing Current (electrolyte dissociation)
-0.43% Battery Self-discharge Current

PVsyst TRIAL
3658 kWh Energy supplied to the user

3732 kWh Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: ISTER
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:37

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 4500 Wp

PVsyst TRIAL
Hacienda San Sebastián - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:47

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
Hacienda San Sebastián Latitude -0.34 °S Albedo 0.20
Ecuador Longitude -78.44 °W
Altitude 2528 m
Time zone UTC-5

Meteo data
Hacienda San Sebastián
NASA-SSE satellite data 1983-2005 - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 13.8 kWh/Day

System information
PV Array Battery pack
Nb. of modules 45 units Technology Lead-acid, vented, tubular
Pnom total 4500 Wp Nb. of units 48 units
Voltage 48 V
Capacity 1308 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 4867.08 kWh/year
Missing Energy
Excess (unused)
178.68 kWh/year
676.68 kWh/year

Project and results summary


Specific production 1082 kWh/kWp/year Perf. Ratio PR
Available solar energy 5817.44 kWh/year

Table of contents
Solar Fraction SF
70.87 %
96.46 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:47

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 13.8 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
12 in parallel x 4 in series
Number of PV modules 45 units Discharging min. SOC 20.0 %
Nominal (STC) 4500 Wp Stored energy 50.2 kWh
Modules 15 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 4219 Wp Nominal Capacity 1308 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 63 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
53.9 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 4.50 kWp
Total 45 modules
Module area 27.4 m²
Cell area 22.7 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
17 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:47

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 13.8 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA 1 1 2200/lamp 3.0 6600
CARGA2 2 1200/app 3.0 7200
Consumidores en espera 24.0 24
Total daily energy 13824

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:47

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 4867.08 kWh/year Perf. Ratio PR 70.87 %
Available solar energy 5817.44 kWh/year Solar Fraction SF 96.46 %
Excess (unused) 676.68 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 3.4 % Cycles SOW 96.0 %
Missing Energy 178.68 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
128.3
121.8
141.1
129.9
GlobEff
kWh/m²
109.3
108.4
132.0
128.3
E_Avail
kWh
435.4
429.3
525.2
507.9
EUnused
kWh
9.6
27.6
90.5
95.6
E_Miss
kWh
17.92
28.35
18.70
0.00
E_User
kWh
410.6
358.7
409.8
414.7
E_Load
kWh
428.5
387.1
428.5
414.7
SolFrac
ratio
0.958
0.927
0.956
1.000
May 127.7 131.9 517.1 58.1 17.92 410.6 428.5 0.958
June 120.6 127.2 504.2 72.4 0.00 414.7 414.7 1.000
July 132.4 139.1 557.4 104.0 0.00 428.5 428.5 1.000
August 138.3 139.2 548.6 98.5 0.00 428.5 428.5 1.000
September 128.1 122.5 471.6 50.0 0.00 414.7 414.7 1.000
October 131.4 118.5 470.3 45.2 31.19 397.3 428.5 0.927
November 129.0 110.7 438.0 16.9 19.35 395.4 414.7 0.953

PVsyst TRIAL
December 123.4 103.5 412.5 8.2 45.25 383.3 428.5 0.894
Year 1552.0 1470.7 5817.4 676.7 178.68 4867.1 5045.8 0.965

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:47

PVsyst TRIAL
with v7.4.0

Loss diagram
1552 kWh/m² Global horizontal irradiation

-1.67% Global incident in coll. plane

-3.63% IAM factor on global

1471 kWh/m² * 27 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

6622 kWh Array nominal energy (at STC effic.)


-1.01% PV loss due to irradiance level

PVsyst TRIAL -4.91%

+1.25%

-1.15%

-1.98%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-11.07% Unused energy (battery full)

5411 kWh Effective energy at the output of the array

-4.68% Converter Loss during operation (efficiency)

-0.69% Converter Loss over nominal conv. power

PVsyst TRIAL
Missing
Direct use
24.9%
5141 kWh
Stored
75.1%
-0.06%
0.00%
0.00%

+0.37%
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
Converter losses (effic, overload)
Battery Storage
Battery Stored Energy balance
energy

3.54% -3.70% Battery efficiency loss


178.7 kWh
-2.21% Charge/Disch. Current Efficiency Loss
-0.22% Gassing Current (electrolyte dissociation)
-0.79% Battery Self-discharge Current

PVsyst TRIAL
4867 kWh Energy supplied to the user

5046 kWh Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:47

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3000 Wp

PVsyst TRIAL
Hacienda Santiago de Monjas - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:53

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
Hacienda Santiago de Monjas Latitude 0.38 °N Albedo 0.20
Ecuador Longitude -78.16 °W
Altitude 1991 m
Time zone UTC-5

Meteo data
Hacienda Santiago de Monjas
PVGIS api TMY

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 30 units Technology Lead-acid, sealed, Gel
Pnom total 3000 Wp Nb. of units 36 units
Voltage 48 V
Capacity 477 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3712.94 kWh/year
Missing Energy
Excess (unused)
18.82 kWh/year
1055.99 kWh/year

Project and results summary


Specific production 1238 kWh/kWp/year Perf. Ratio PR
Available solar energy 5146.31 kWh/year

Table of contents
Solar Fraction SF
62.95 %
99.50 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:53

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Imported
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 1 RES OPzV 65
Lead-acid, sealed, Gel
9 in parallel x 4 in series
Number of PV modules 30 units Discharging min. SOC 20.0 %
Nominal (STC) 3000 Wp Stored energy 18.3 kWh
Modules 10 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2813 Wp Nominal Capacity 477 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 42 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.90 / 0.75
55.1 / 50.1 V
SOC = 0.20 / 0.45
46.0 / 48.9 V

Total PV power
Nominal (STC) 3.00 kWp
Total 30 modules
Module area 18.3 m²
Cell area 15.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
25 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:53

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1 1 2200/lamp 3.0 6600
CARAG2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:53

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3712.94 kWh/year Perf. Ratio PR 62.95 %
Available solar energy 5146.31 kWh/year Solar Fraction SF 99.50 %
Excess (unused) 1055.99 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.6 % Cycles SOW 90.9 %
Missing Energy 18.82 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
175.3
154.7
162.8
154.3
GlobEff
kWh/m²
184.0
157.2
155.5
140.4
E_Avail
kWh
491.3
420.3
421.1
382.1
EUnused
kWh
127.8
107.4
60.8
51.3
E_Miss
kWh
0.000
6.399
1.448
0.000
E_User
kWh
316.9
279.9
315.5
306.7
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
1.000
0.978
0.995
1.000
May 154.3 133.0 363.4 36.2 9.509 307.4 316.9 0.970
June 152.2 127.2 347.8 10.9 1.459 305.3 306.7 0.995
July 163.5 137.0 374.2 24.4 0.000 316.9 316.9 1.000
August 175.4 154.4 419.8 76.2 0.000 316.9 316.9 1.000
September 168.5 158.7 430.7 92.7 0.000 306.7 306.7 1.000
October 177.0 176.7 475.9 129.5 0.000 316.9 316.9 1.000
November 181.1 189.9 507.5 172.7 0.000 306.7 306.7 1.000

PVsyst TRIAL
December 178.5 191.1 512.3 166.0 0.000 316.9 316.9 1.000
Year 1997.6 1905.1 5146.3 1056.0 18.815 3712.9 3731.8 0.995

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:53

PVsyst TRIAL
with v7.4.0

Loss diagram
1998 kWh/m² Global horizontal irradiation

-1.58% Global incident in coll. plane

-3.10% IAM factor on global

1905 kWh/m² * 18 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

5719 kWh Array nominal energy (at STC effic.)


-0.50% PV loss due to irradiance level

PVsyst TRIAL -4.03%

+1.25%

-1.15%

-2.06%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-19.73% Unused energy (battery full)

4277 kWh Effective energy at the output of the array

-3.92% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.78% Converter Loss over nominal conv. power
-0.01% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
4090 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 21.7% 78.3%
+0.07% Battery Stored Energy balance
energy
0.50% -8.13% Battery efficiency loss
18.8 kWh
-2.32% Charge/Disch. Current Efficiency Loss
-0.15% Gassing Current (electrolyte dissociation)

PVsyst TRIAL
-0.37% Battery Self-discharge Current
3713 kWh Energy supplied to the user

3732 kWh Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:53

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3000 Wp

PVsyst TRIAL
Hacienda San Sebastián - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:59

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
Hacienda San Sebastián Latitude -0.34 °S Albedo 0.20
Ecuador Longitude -78.44 °W
Altitude 2528 m
Time zone UTC-5

Meteo data
Hacienda San Sebastián
NREL NSRDB Typ. Met. Year PSMv3_1998 to 2020 - TMY

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 30 units Technology Lead-acid, vented, tubular
Pnom total 3000 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3731.76 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
1076.43 kWh/year

Project and results summary


Specific production 1244 kWh/kWp/year Perf. Ratio PR
Available solar energy 4982.57 kWh/year

Table of contents
Solar Fraction SF
65.17 %
100.00 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:59

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Imported
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 30 units Discharging min. SOC 20.0 %
Nominal (STC) 3000 Wp Stored energy 20.9 kWh
Modules 10 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2813 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 42 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.4 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 3.00 kWp
Total 30 modules
Module area 18.3 m²
Cell area 15.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
25 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:59

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1 1 2200/lamp 3.0 6600
CARGA2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:59

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3731.76 kWh/year Perf. Ratio PR 65.17 %
Available solar energy 4982.57 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 1076.43 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 91.2 %
Missing Energy 0.00 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
161.2
141.5
163.6
151.4
GlobEff
kWh/m²
137.4
127.2
153.8
149.6
E_Avail
kWh
371.2
344.7
415.6
403.3
EUnused
kWh
35.5
46.8
82.0
83.6
E_Miss
kWh
0.000
0.000
0.000
0.000
E_User
kWh
316.9
286.3
316.9
306.7
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
1.000
1.000
1.000
1.000
May 148.8 153.3 414.6 83.3 0.000 316.9 316.9 1.000
June 148.9 157.4 426.0 104.7 0.000 306.7 306.7 1.000
July 170.7 180.7 490.2 158.6 0.000 316.9 316.9 1.000
August 178.3 182.1 490.0 158.4 0.000 316.9 316.9 1.000
September 171.5 165.0 443.3 122.3 0.000 306.7 306.7 1.000
October 173.4 158.2 427.1 95.3 0.000 316.9 316.9 1.000
November 166.5 142.8 385.6 64.5 0.000 306.7 306.7 1.000

PVsyst TRIAL
December 163.7 137.1 371.1 41.5 0.000 316.9 316.9 1.000
Year 1939.5 1844.7 4982.6 1076.4 0.000 3731.8 3731.8 1.000

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:59

PVsyst TRIAL
with v7.4.0

Loss diagram
1940 kWh/m² Global horizontal irradiation

-1.59% Global incident in coll. plane

-3.35% IAM factor on global

1845 kWh/m² * 18 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

5537 kWh Array nominal energy (at STC effic.)


-0.58% PV loss due to irradiance level

PVsyst TRIAL -4.20%

+1.25%

-1.15%

-2.03%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-20.81% Unused energy (battery full)

4087 kWh Effective energy at the output of the array

-4.11% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.44% Converter Loss over nominal conv. power
-0.03% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
3906 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 21.7% 78.3%
+0.05% Battery Stored Energy balance
energy
0.00%
-3.13% Battery efficiency loss
0.0 kWh
-2.20% Charge/Disch. Current Efficiency Loss
-0.20% Gassing Current (electrolyte dissociation)
-0.42% Battery Self-discharge Current

PVsyst TRIAL 3732 kWh

3732 kWh
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 15:59

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3000 Wp

PVsyst TRIAL La Colina - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:11

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
La Colina Latitude -0.32 °S Albedo 0.20
Ecuador Longitude -78.44 °W
Altitude 2508 m
Time zone UTC-5

Meteo data
Hacienda San Sebastián
NREL NSRDB Typ. Met. Year PSMv3_1998 to 2020 - TMY

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 30 units Technology Lead-acid, vented, tubular
Pnom total 3000 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3731.76 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
1076.07 kWh/year

Project and results summary


Specific production 1244 kWh/kWp/year Perf. Ratio PR
Available solar energy 4982.20 kWh/year

Table of contents
Solar Fraction SF
65.18 %
100.00 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:11

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Imported
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 30 units Discharging min. SOC 20.0 %
Nominal (STC) 3000 Wp Stored energy 20.9 kWh
Modules 10 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2813 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 42 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.4 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 3.00 kWp
Total 30 modules
Module area 18.3 m²
Cell area 15.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
25 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:11

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1 1 2200/lamp 3.0 6600
CARGA2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:11

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3731.76 kWh/year Perf. Ratio PR 65.18 %
Available solar energy 4982.20 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 1076.07 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 91.2 %
Missing Energy 0.00 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
161.2
141.5
163.6
151.4
GlobEff
kWh/m²
137.4
127.2
153.8
149.6
E_Avail
kWh
371.1
344.7
415.6
403.2
EUnused
kWh
35.5
46.7
81.9
83.6
E_Miss
kWh
0.000
0.000
0.000
0.000
E_User
kWh
316.9
286.3
316.9
306.7
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
1.000
1.000
1.000
1.000
May 148.8 153.3 414.6 83.3 0.000 316.9 316.9 1.000
June 148.9 157.4 426.0 104.7 0.000 306.7 306.7 1.000
July 170.7 180.7 490.2 158.6 0.000 316.9 316.9 1.000
August 178.3 182.1 489.9 158.4 0.000 316.9 316.9 1.000
September 171.5 165.0 443.2 122.3 0.000 306.7 306.7 1.000
October 173.4 158.2 427.1 95.3 0.000 316.9 316.9 1.000
November 166.5 142.8 385.6 64.4 0.000 306.7 306.7 1.000

PVsyst TRIAL
December 163.7 137.0 371.0 41.4 0.000 316.9 316.9 1.000
Year 1939.5 1844.5 4982.2 1076.1 0.000 3731.8 3731.8 1.000

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:11

PVsyst TRIAL
with v7.4.0

Loss diagram
1940 kWh/m² Global horizontal irradiation

-1.60% Global incident in coll. plane

-3.35% IAM factor on global

1845 kWh/m² * 18 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

5537 kWh Array nominal energy (at STC effic.)


-0.58% PV loss due to irradiance level

PVsyst TRIAL -4.20%

+1.25%

-1.15%

-2.03%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-20.81% Unused energy (battery full)

4087 kWh Effective energy at the output of the array

-4.11% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.44% Converter Loss over nominal conv. power
-0.03% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
3906 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 21.7% 78.3%
+0.05% Battery Stored Energy balance
energy
0.00%
-3.13% Battery efficiency loss
0.0 kWh
-2.20% Charge/Disch. Current Efficiency Loss
-0.20% Gassing Current (electrolyte dissociation)
-0.42% Battery Self-discharge Current

PVsyst TRIAL 3732 kWh

3732 kWh
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:11

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 4200 Wp

PVsyst TRIAL La Colina - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:17

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
La Colina Latitude -0.32 °S Albedo 0.20
Ecuador Longitude -78.44 °W
Altitude 2508 m
Time zone UTC-5

Meteo data
La Colina
NASA-SSE satellite data 1983-2005 - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 42 units Technology Lead-acid, vented, tubular
Pnom total 4200 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3519.88 kWh/year
Missing Energy
Excess (unused)
211.88 kWh/year
1730.09 kWh/year

Project and results summary


Specific production 838 kWh/kWp/year Perf. Ratio PR
Available solar energy 5486.76 kWh/year

Table of contents
Solar Fraction SF
54.89 %
94.32 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:17

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 42 units Discharging min. SOC 20.0 %
Nominal (STC) 4200 Wp Stored energy 20.9 kWh
Modules 14 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 3938 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 59 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.7 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 4.20 kWp
Total 42 modules
Module area 25.6 m²
Cell area 21.2 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
18 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:17

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1) 1 2200/lamp 3.0 6600
CARGA2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:17

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3519.88 kWh/year Perf. Ratio PR 54.89 %
Available solar energy 5486.76 kWh/year Solar Fraction SF 94.32 %
Excess (unused) 1730.09 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 6.2 % Cycles SOW 91.9 %
Missing Energy 211.88 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
128.3
121.8
141.0
129.9
GlobEff
kWh/m²
109.3
108.5
132.0
128.3
E_Avail
kWh
409.5
404.7
493.3
477.2
EUnused
kWh
94.0
122.2
170.6
173.9
E_Miss
kWh
28.07
22.24
14.10
11.38
E_User
kWh
288.9
264.0
302.8
295.3
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
0.911
0.922
0.956
0.963
May 127.7 131.5 484.8 165.6 32.55 284.4 316.9 0.897
June 120.6 127.1 475.2 168.8 20.89 285.8 306.7 0.932
July 132.4 139.5 526.1 189.8 0.00 316.9 316.9 1.000
August 138.3 138.9 517.3 183.8 0.00 316.9 316.9 1.000
September 128.1 122.6 451.0 157.0 22.35 284.4 306.7 0.927
October 131.4 119.6 442.9 135.4 22.77 294.2 316.9 0.928
November 129.0 110.9 414.9 101.5 20.90 285.8 306.7 0.932

PVsyst TRIAL
December 123.4 104.3 389.7 67.6 16.63 300.3 316.9 0.948
Year 1552.0 1472.3 5486.8 1730.1 211.88 3519.9 3731.8 0.943

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:17

PVsyst TRIAL
with v7.4.0

Loss diagram
1552 kWh/m² Global horizontal irradiation

-1.62% Global incident in coll. plane

-3.57% IAM factor on global

1472 kWh/m² * 26 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

6187 kWh Array nominal energy (at STC effic.)


-1.00% PV loss due to irradiance level

PVsyst TRIAL -4.90%

+1.25%

-1.15%

-1.97%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-30.27% Unused energy (battery full)

3967 kWh Effective energy at the output of the array

PVsyst TRIAL
-5.06% Converter Loss during operation (efficiency)

-0.40% Converter Loss over nominal conv. power


-0.08% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
3757 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 22.1% 77.9%
+0.14% Battery Stored Energy balance
energy

5.68% -4.88% Battery efficiency loss


211.9 kWh
-2.24% Charge/Disch. Current Efficiency Loss
-0.12% Gassing Current (electrolyte dissociation)

PVsyst TRIAL 3520 kWh

3732 kWh
-0.44% Battery Self-discharge Current
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:17

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3000 Wp

PVsyst TRIAL La Colina - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:21

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
La Colina Latitude -0.32 °S Albedo 0.20
Ecuador Longitude -78.44 °W
Altitude 2508 m
Time zone UTC-5

Meteo data
La Colina
PVGIS api TMY

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 30 units Technology Lead-acid, vented, tubular
Pnom total 3000 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3725.84 kWh/year
Missing Energy
Excess (unused)
5.92 kWh/year
1063.84 kWh/year

Project and results summary


Specific production 1242 kWh/kWp/year Perf. Ratio PR
Available solar energy 5011.17 kWh/year

Table of contents
Solar Fraction SF
64.91 %
99.84 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:21

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Imported
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 30 units Discharging min. SOC 20.0 %
Nominal (STC) 3000 Wp Stored energy 20.9 kWh
Modules 10 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2813 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 42 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.4 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 3.00 kWp
Total 30 modules
Module area 18.3 m²
Cell area 15.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
25 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:21

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1 1 2200/lamp 3.0 6600
CARGA2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:21

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3725.84 kWh/year Perf. Ratio PR 64.91 %
Available solar energy 5011.17 kWh/year Solar Fraction SF 99.84 %
Excess (unused) 1063.84 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.2 % Cycles SOW 91.3 %
Missing Energy 5.92 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
155.8
143.1
152.2
137.5
GlobEff
kWh/m²
133.7
128.4
142.6
135.4
E_Avail
kWh
363.2
348.3
386.1
367.3
EUnused
kWh
25.3
37.7
46.9
49.4
E_Miss
kWh
5.917
0.000
0.000
0.000
E_User
kWh
311.0
286.3
316.9
306.7
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
0.981
1.000
1.000
1.000
May 154.0 159.0 431.3 94.4 0.000 316.9 316.9 1.000
June 146.3 154.4 420.2 100.9 0.000 306.7 306.7 1.000
July 180.9 192.6 518.5 173.7 0.000 316.9 316.9 1.000
August 179.1 182.2 492.5 158.7 0.000 316.9 316.9 1.000
September 195.3 188.9 505.6 184.5 0.000 306.7 306.7 1.000
October 159.6 145.7 393.8 66.0 0.000 316.9 316.9 1.000
November 172.4 148.1 402.0 76.3 0.000 306.7 306.7 1.000

PVsyst TRIAL
December 168.3 140.4 382.3 50.1 0.000 316.9 316.9 1.000
Year 1944.7 1851.3 5011.2 1063.8 5.917 3725.8 3731.8 0.998

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:21

PVsyst TRIAL
with v7.4.0

Loss diagram
1945 kWh/m² Global horizontal irradiation

-1.61% Global incident in coll. plane

-3.24% IAM factor on global

1851 kWh/m² * 18 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

5557 kWh Array nominal energy (at STC effic.)


-0.54% PV loss due to irradiance level

PVsyst TRIAL -3.99%

+1.25%

-1.15%

-2.04%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-20.45% Unused energy (battery full)

4127 kWh Effective energy at the output of the array

-4.06% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.49% Converter Loss over nominal conv. power
-0.01% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
3947 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 20.9% 79.1%
+0.09% Battery Stored Energy balance
energy
0.16% -4.29% Battery efficiency loss
5.9 kWh
-2.26% Charge/Disch. Current Efficiency Loss
-0.17% Gassing Current (electrolyte dissociation)
-0.42% Battery Self-discharge Current

PVsyst TRIAL 3726 kWh

3732 kWh
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:21

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3000 Wp

PVsyst TRIAL La Colina - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:26

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
La Colina Latitude -0.32 °S Albedo 0.20
Ecuador Longitude -78.44 °W
Altitude 2508 m
Time zone UTC-5

Meteo data
La Colina
NREL NSRDB Typ. Met. Year PSMv3_1998 to 2020 - TMY

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 30 units Technology Lead-acid, vented, tubular
Pnom total 3000 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3731.76 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
1185.19 kWh/year

Project and results summary


Specific production 1244 kWh/kWp/year Perf. Ratio PR
Available solar energy 5093.05 kWh/year

Table of contents
Solar Fraction SF
63.64 %
100.00 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:26

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Imported
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 30 units Discharging min. SOC 20.0 %
Nominal (STC) 3000 Wp Stored energy 20.9 kWh
Modules 10 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2813 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 42 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.4 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 3.00 kWp
Total 30 modules
Module area 18.3 m²
Cell area 15.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
25 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:26

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1 1 2200/lamp 3.0 6600
CARGA2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:26

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3731.76 kWh/year Perf. Ratio PR 63.64 %
Available solar energy 5093.05 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 1185.19 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 91.1 %
Missing Energy 0.00 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
168.1
145.1
164.5
155.9
GlobEff
kWh/m²
142.9
130.2
154.7
154.5
E_Avail
kWh
386.1
352.4
417.5
415.1
EUnused
kWh
50.6
51.7
86.3
95.4
E_Miss
kWh
0.000
0.000
0.000
0.000
E_User
kWh
316.9
286.3
316.9
306.7
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
1.000
1.000
1.000
1.000
May 154.6 160.2 431.6 100.4 0.000 316.9 316.9 1.000
June 159.3 170.3 460.1 138.7 0.000 306.7 306.7 1.000
July 176.0 186.8 504.4 173.2 0.000 316.9 316.9 1.000
August 180.4 184.2 495.5 163.9 0.000 316.9 316.9 1.000
September 171.3 164.3 441.5 120.7 0.000 306.7 306.7 1.000
October 173.6 157.8 422.4 90.5 0.000 316.9 316.9 1.000
November 164.5 141.5 381.8 60.7 0.000 306.7 306.7 1.000

PVsyst TRIAL
December 171.6 142.5 384.4 53.3 0.000 316.9 316.9 1.000
Year 1984.8 1889.7 5093.1 1185.2 0.000 3731.8 3731.8 1.000

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:26

PVsyst TRIAL
with v7.4.0

Loss diagram
1985 kWh/m² Global horizontal irradiation

-1.52% Global incident in coll. plane

-3.32% IAM factor on global

1890 kWh/m² * 18 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

5672 kWh Array nominal energy (at STC effic.)


-0.55% PV loss due to irradiance level

PVsyst TRIAL -4.45%

+1.25%

-1.15%

-2.06%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-22.43% Unused energy (battery full)

4090 kWh Effective energy at the output of the array

-4.09% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.50% Converter Loss over nominal conv. power
-0.02% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
3908 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 20.9% 79.1%
+0.09% Battery Stored Energy balance
energy
0.00%
-3.10% Battery efficiency loss
0.0 kWh
-2.21% Charge/Disch. Current Efficiency Loss
-0.20% Gassing Current (electrolyte dissociation)

PVsyst TRIAL
-0.41% Battery Self-discharge Current
3732 kWh Energy supplied to the user

3732 kWh Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:26

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3000 Wp

PVsyst TRIAL San Luis - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:34

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
San Luis Latitude -0.33 °S Albedo 0.20
Ecuador Longitude -78.45 °W
Altitude 2500 m
Time zone UTC-5

Meteo data
La Colina
NREL NSRDB Typ. Met. Year PSMv3_1998 to 2020 - TMY

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 30 units Technology Lead-acid, vented, tubular
Pnom total 3000 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3731.76 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
1185.34 kWh/year

Project and results summary


Specific production 1244 kWh/kWp/year Perf. Ratio PR
Available solar energy 5093.20 kWh/year

Table of contents
Solar Fraction SF
63.64 %
100.00 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:34

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Imported
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 30 units Discharging min. SOC 20.0 %
Nominal (STC) 3000 Wp Stored energy 20.9 kWh
Modules 10 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2813 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 42 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.4 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 3.00 kWp
Total 30 modules
Module area 18.3 m²
Cell area 15.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
25 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:34

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1 1 2200/lamp 3.0 6600
CARGA2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:34

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3731.76 kWh/year Perf. Ratio PR 63.64 %
Available solar energy 5093.20 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 1185.34 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 91.1 %
Missing Energy 0.00 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
168.1
145.1
164.5
155.9
GlobEff
kWh/m²
142.9
130.2
154.7
154.5
E_Avail
kWh
386.2
352.4
417.5
415.1
EUnused
kWh
50.6
51.7
86.3
95.4
E_Miss
kWh
0.000
0.000
0.000
0.000
E_User
kWh
316.9
286.3
316.9
306.7
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
1.000
1.000
1.000
1.000
May 154.6 160.2 431.7 100.4 0.000 316.9 316.9 1.000
June 159.3 170.3 460.1 138.7 0.000 306.7 306.7 1.000
July 176.0 186.8 504.4 173.2 0.000 316.9 316.9 1.000
August 180.4 184.2 495.5 163.9 0.000 316.9 316.9 1.000
September 171.3 164.3 441.5 120.7 0.000 306.7 306.7 1.000
October 173.6 157.8 422.4 90.5 0.000 316.9 316.9 1.000
November 164.5 141.5 381.9 60.7 0.000 306.7 306.7 1.000

PVsyst TRIAL
December 171.6 142.5 384.4 53.3 0.000 316.9 316.9 1.000
Year 1984.8 1889.7 5093.2 1185.3 0.000 3731.8 3731.8 1.000

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:34

PVsyst TRIAL
with v7.4.0

Loss diagram
1985 kWh/m² Global horizontal irradiation

-1.52% Global incident in coll. plane

-3.32% IAM factor on global

1890 kWh/m² * 18 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

5672 kWh Array nominal energy (at STC effic.)


-0.55% PV loss due to irradiance level

PVsyst TRIAL -4.45%

+1.25%

-1.15%

-2.06%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-22.43% Unused energy (battery full)

4090 kWh Effective energy at the output of the array

-4.10% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.50% Converter Loss over nominal conv. power
-0.02% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
3908 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 20.9% 79.1%
+0.09% Battery Stored Energy balance
energy
0.00%
-3.10% Battery efficiency loss
0.0 kWh
-2.21% Charge/Disch. Current Efficiency Loss
-0.20% Gassing Current (electrolyte dissociation)

PVsyst TRIAL
-0.41% Battery Self-discharge Current
3732 kWh Energy supplied to the user

3732 kWh Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:34

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 4200 Wp

PVsyst TRIAL San Luis - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:37

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
San Luis Latitude -0.33 °S Albedo 0.20
Ecuador Longitude -78.45 °W
Altitude 2500 m
Time zone UTC-5

Meteo data
San Luis
NASA-SSE satellite data 1983-2005 - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 42 units Technology Lead-acid, vented, tubular
Pnom total 4200 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3519.83 kWh/year
Missing Energy
Excess (unused)
211.93 kWh/year
1730.12 kWh/year

Project and results summary


Specific production 838 kWh/kWp/year Perf. Ratio PR
Available solar energy 5486.70 kWh/year

Table of contents
Solar Fraction SF
54.89 %
94.32 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:37

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 42 units Discharging min. SOC 20.0 %
Nominal (STC) 4200 Wp Stored energy 20.9 kWh
Modules 14 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 3938 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 59 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.7 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 4.20 kWp
Total 42 modules
Module area 25.6 m²
Cell area 21.2 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
18 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:37

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARAG1 1 2200/lamp 3.0 6600
CARAG2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:37

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3519.83 kWh/year Perf. Ratio PR 54.89 %
Available solar energy 5486.70 kWh/year Solar Fraction SF 94.32 %
Excess (unused) 1730.12 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 6.2 % Cycles SOW 91.9 %
Missing Energy 211.93 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
128.3
121.8
141.1
129.9
GlobEff
kWh/m²
109.3
108.5
132.0
128.3
E_Avail
kWh
409.5
404.7
493.2
477.2
EUnused
kWh
94.0
122.2
170.5
173.9
E_Miss
kWh
28.07
22.23
14.15
11.38
E_User
kWh
288.9
264.0
302.8
295.3
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
0.911
0.922
0.955
0.963
May 127.7 131.5 484.8 165.6 32.54 284.4 316.9 0.897
June 120.6 127.1 475.2 168.8 20.89 285.8 306.7 0.932
July 132.4 139.5 526.3 190.0 0.00 316.9 316.9 1.000
August 138.3 138.9 517.3 183.8 0.00 316.9 316.9 1.000
September 128.1 122.6 451.0 157.0 22.35 284.4 306.7 0.927
October 131.4 119.6 442.9 135.4 22.76 294.2 316.9 0.928
November 129.0 110.9 414.8 101.4 20.91 285.8 306.7 0.932

PVsyst TRIAL
December 123.4 104.3 389.7 67.6 16.63 300.3 316.9 0.948
Year 1552.0 1472.4 5486.7 1730.1 211.93 3519.8 3731.8 0.943

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:37

PVsyst TRIAL
with v7.4.0

Loss diagram
1552 kWh/m² Global horizontal irradiation

-1.62% Global incident in coll. plane

-3.57% IAM factor on global

1472 kWh/m² * 26 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

6188 kWh Array nominal energy (at STC effic.)


-1.00% PV loss due to irradiance level

PVsyst TRIAL -4.90%

+1.25%

-1.15%

-1.97%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-30.27% Unused energy (battery full)

3967 kWh Effective energy at the output of the array

PVsyst TRIAL
-5.06% Converter Loss during operation (efficiency)

-0.40% Converter Loss over nominal conv. power


-0.08% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
3757 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 22.1% 77.9%
+0.14% Battery Stored Energy balance
energy

5.68% -4.88% Battery efficiency loss


211.9 kWh
-2.24% Charge/Disch. Current Efficiency Loss
-0.12% Gassing Current (electrolyte dissociation)

PVsyst TRIAL 3520 kWh

3732 kWh
-0.44% Battery Self-discharge Current
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:37

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3000 Wp

PVsyst TRIAL San Luis - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:40

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
San Luis Latitude -0.33 °S Albedo 0.20
Ecuador Longitude -78.45 °W
Altitude 2500 m
Time zone UTC-5

Meteo data
San Luis
PVGIS api TMY

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 30 units Technology Lead-acid, vented, tubular
Pnom total 3000 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3725.84 kWh/year
Missing Energy
Excess (unused)
5.92 kWh/year
1062.74 kWh/year

Project and results summary


Specific production 1242 kWh/kWp/year Perf. Ratio PR
Available solar energy 5011.27 kWh/year

Table of contents
Solar Fraction SF
64.91 %
99.84 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:40

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Imported
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 30 units Discharging min. SOC 20.0 %
Nominal (STC) 3000 Wp Stored energy 20.9 kWh
Modules 10 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2813 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 42 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.4 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 3.00 kWp
Total 30 modules
Module area 18.3 m²
Cell area 15.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
25 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:40

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1 1 2200/lamp 3.0 6600
CARGA2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:40

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3725.84 kWh/year Perf. Ratio PR 64.91 %
Available solar energy 5011.27 kWh/year Solar Fraction SF 99.84 %
Excess (unused) 1062.74 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.2 % Cycles SOW 91.3 %
Missing Energy 5.92 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
155.8
143.1
152.2
137.5
GlobEff
kWh/m²
133.7
128.4
142.6
135.4
E_Avail
kWh
363.1
348.3
386.2
367.3
EUnused
kWh
24.1
37.8
46.9
49.4
E_Miss
kWh
5.916
0.000
0.000
0.000
E_User
kWh
311.0
286.3
316.9
306.7
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
0.981
1.000
1.000
1.000
May 154.0 159.0 431.3 94.4 0.000 316.9 316.9 1.000
June 146.3 154.4 420.2 100.9 0.000 306.7 306.7 1.000
July 180.9 192.6 518.6 173.7 0.000 316.9 316.9 1.000
August 179.1 182.2 492.6 158.7 0.000 316.9 316.9 1.000
September 195.3 188.9 505.6 184.5 0.000 306.7 306.7 1.000
October 159.6 145.7 393.8 66.0 0.000 316.9 316.9 1.000
November 172.4 148.1 402.0 76.3 0.000 306.7 306.7 1.000

PVsyst TRIAL
December 168.3 140.4 382.3 50.1 0.000 316.9 316.9 1.000
Year 1944.7 1851.4 5011.3 1062.7 5.916 3725.8 3731.8 0.998

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:40

PVsyst TRIAL
with v7.4.0

Loss diagram
1945 kWh/m² Global horizontal irradiation

-1.61% Global incident in coll. plane

-3.24% IAM factor on global

1851 kWh/m² * 18 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

5557 kWh Array nominal energy (at STC effic.)


-0.54% PV loss due to irradiance level

PVsyst TRIAL -3.99%

+1.25%

-1.15%

-2.04%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-20.43% Unused energy (battery full)

4129 kWh Effective energy at the output of the array

-4.06% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.49% Converter Loss over nominal conv. power
-0.01% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
3949 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 20.9% 79.1%
+0.09% Battery Stored Energy balance
energy
0.16% -4.32% Battery efficiency loss
5.9 kWh
-2.26% Charge/Disch. Current Efficiency Loss
-0.17% Gassing Current (electrolyte dissociation)
-0.42% Battery Self-discharge Current

PVsyst TRIAL 3726 kWh

3732 kWh
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:40

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.4.0

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3000 Wp

PVsyst TRIAL San Luis - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:45

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
San Luis Latitude -0.33 °S Albedo 0.20
Ecuador Longitude -78.45 °W
Altitude 2500 m
Time zone UTC-5

Meteo data
San Luis
PVGIS api TMY

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.2 kWh/Day

System information
PV Array Battery pack
Nb. of modules 30 units Technology Lead-acid, vented, tubular
Pnom total 3000 Wp Nb. of units 20 units
Voltage 48 V
Capacity 545 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3725.84 kWh/year
Missing Energy
Excess (unused)
5.92 kWh/year
1062.74 kWh/year

Project and results summary


Specific production 1242 kWh/kWp/year Perf. Ratio PR
Available solar energy 5011.27 kWh/year

Table of contents
Solar Fraction SF
64.91 %
99.84 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:45

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Imported
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.2 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 100 Wp
PV Array Characteristics

Generic
HDT-20FH-100
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 2 RES OPzS 130
Lead-acid, vented, tubular
5 in parallel x 4 in series
Number of PV modules 30 units Discharging min. SOC 20.0 %
Nominal (STC) 3000 Wp Stored energy 20.9 kWh
Modules 10 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2813 Wp Nominal Capacity 545 Ah (C10)
U mpp 67 V Temperature Fixed 20 °C
I mpp 42 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
54.4 / 50.1 V
SOC = 0.20 / 0.45
47.2 / 48.9 V

Total PV power
Nominal (STC) 3.00 kWp
Total 30 modules
Module area 18.3 m²
Cell area 15.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-1.3 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
25 mΩ
1.5 % at STC

1.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:45

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.2 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA1 1 2200/lamp 3.0 6600
CARGA2 1 1200/app 3.0 3600
Consumidores en espera 24.0 24
Total daily energy 10224

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:45

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 3725.84 kWh/year Perf. Ratio PR 64.91 %
Available solar energy 5011.27 kWh/year Solar Fraction SF 99.84 %
Excess (unused) 1062.74 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.2 % Cycles SOW 91.3 %
Missing Energy 5.92 kWh/year Static SOW 94.4 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
155.8
143.1
152.2
137.5
GlobEff
kWh/m²
133.7
128.4
142.6
135.4
E_Avail
kWh
363.1
348.3
386.2
367.3
EUnused
kWh
24.1
37.8
46.9
49.4
E_Miss
kWh
5.916
0.000
0.000
0.000
E_User
kWh
311.0
286.3
316.9
306.7
E_Load
kWh
316.9
286.3
316.9
306.7
SolFrac
ratio
0.981
1.000
1.000
1.000
May 154.0 159.0 431.3 94.4 0.000 316.9 316.9 1.000
June 146.3 154.4 420.2 100.9 0.000 306.7 306.7 1.000
July 180.9 192.6 518.6 173.7 0.000 316.9 316.9 1.000
August 179.1 182.2 492.6 158.7 0.000 316.9 316.9 1.000
September 195.3 188.9 505.6 184.5 0.000 306.7 306.7 1.000
October 159.6 145.7 393.8 66.0 0.000 316.9 316.9 1.000
November 172.4 148.1 402.0 76.3 0.000 306.7 306.7 1.000

PVsyst TRIAL
December 168.3 140.4 382.3 50.1 0.000 316.9 316.9 1.000
Year 1944.7 1851.4 5011.3 1062.7 5.916 3725.8 3731.8 0.998

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:45

PVsyst TRIAL
with v7.4.0

Loss diagram
1945 kWh/m² Global horizontal irradiation

-1.61% Global incident in coll. plane

-3.24% IAM factor on global

1851 kWh/m² * 18 m² coll. Effective irradiation on collectors

efficiency at STC = 16.44% PV conversion

5557 kWh Array nominal energy (at STC effic.)


-0.54% PV loss due to irradiance level

PVsyst TRIAL -3.99%

+1.25%

-1.15%

-2.04%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-20.43% Unused energy (battery full)

4129 kWh Effective energy at the output of the array

-4.06% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.49% Converter Loss over nominal conv. power
-0.01% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
3949 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
Missing 20.9% 79.1%
+0.09% Battery Stored Energy balance
energy
0.16% -4.32% Battery efficiency loss
5.9 kWh
-2.26% Charge/Disch. Current Efficiency Loss
-0.17% Gassing Current (electrolyte dissociation)
-0.42% Battery Self-discharge Current

PVsyst TRIAL 3726 kWh

3732 kWh
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.4.0
VC0, Simulation date:
01/08/23 16:45

PVsyst TRIAL
with v7.4.0

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
01/08/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Puerto Quito


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 1920 Wp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC3, Simulation date:
17/07/23 08:44

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 5.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 6 units Technology Lithium-ion, LFP
Pnom total 1920 Wp Nb. of units 2 units
Voltage 53 V
Capacity 216 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 1776.26 kWh/year
Missing Energy
Excess (unused)
57.50 kWh/year
524.50 kWh/year

Project and results summary


Specific production 925 kWh/kWp/year Perf. Ratio PR
Available solar energy 2543.59 kWh/year

Table of contents
Solar Fraction SF
58.91 %
96.86 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC3, Simulation date:
17/07/23 08:44

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 5.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
2 in parallel
Number of PV modules 6 units Discharging min. SOC 10.0 %
Nominal (STC) 1920 Wp Stored energy 10.4 kWh
Modules 2 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 1806 Wp Nominal Capacity 216 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 27 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 1.92 kWp
Total 6 modules
Module area 10.2 m²
Cell area 9.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
41 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC3, Simulation date:
17/07/23 08:44

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 5.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
carga 1 5000/lamp 1.0 5000
Consumidores en espera 24.0 24
Total daily energy 5024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC3, Simulation date:
17/07/23 08:44

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 1776.26 kWh/year Performance Ratio PR 58.91 %
Available solar energy 2543.59 kWh/year Solar Fraction SF 96.86 %
Excess (unused) 524.50 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 6.0 % Cycles SOW 98.4 %
Missing Energy 57.50 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
250.0
222.6
234.9
232.8
EUnused
kWh
74.66
63.05
61.40
59.71
E_Miss
kWh
1.04
0.00
1.28
0.00
E_User
kWh
154.7
140.7
154.5
150.7
E_Load
kWh
155.7
140.7
155.7
150.7
SolFrac
ratio
0.993
1.000
0.992
1.000
May 148.7 127.9 214.6 38.77 0.00 155.7 155.7 1.000
June 134.7 114.1 192.6 19.90 1.30 149.4 150.7 0.991
July 133.9 114.6 193.5 29.51 12.32 143.4 155.7 0.921
August 134.7 120.2 202.5 33.14 5.73 150.0 155.7 0.963
September 115.9 108.7 181.3 33.93 24.59 126.1 150.7 0.837
October 116.7 113.3 189.3 20.90 7.22 148.5 155.7 0.954
November 116.5 117.7 196.5 31.56 4.01 146.7 150.7 0.973

PVsyst TRIAL
December 133.8 138.6 233.1 57.96 0.00 155.7 155.7 1.000
Year 1612.6 1516.2 2543.6 524.50 57.50 1776.3 1833.8 0.969

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC3, Simulation date:
17/07/23 08:44

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 10 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

2922 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-19.83% Unused energy (battery full)

2120 kWh Effective energy at the output of the array

-4.67% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.03% Converter Loss over nominal conv. power
-0.07% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold

Missing 2019 kWh Converter losses (effic, overload)


Direct use
energy Stored Battery Storage
5.0% 95.0%
-0.03% Battery Stored Energy balance
3.14%
57.5 kWh -10.93% Battery efficiency loss

-2.99% Charge/Disch. Current Efficiency Loss


-0.13% Battery Self-discharge Current
1776 kWh Energy supplied to the user

PVsyst TRIAL 1834 kWh Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC3, Simulation date:
17/07/23 08:44

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Puerto Quito


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 2880 Wp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:47

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 6.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 9 units Technology Lithium-ion, LFP
Pnom total 2880 Wp Nb. of units 2 units
Voltage 53 V
Capacity 216 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 2158.59 kWh/year
Missing Energy
Excess (unused)
40.17 kWh/year
1541.30 kWh/year

Project and results summary


Specific production 750 kWh/kWp/year Perf. Ratio PR
Available solar energy 3848.35 kWh/year

Table of contents
Solar Fraction SF
47.73 %
98.17 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:47

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 6.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
2 in parallel
Number of PV modules 9 units Discharging min. SOC 10.0 %
Nominal (STC) 2880 Wp Stored energy 10.4 kWh
Modules 3 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 2708 Wp Nominal Capacity 216 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 40 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 2.88 kWp
Total 9 modules
Module area 15.3 m²
Cell area 13.6 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
27 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:47

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 6.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
CARGA2 1 6000/lamp 1.0 6000
Consumidores en espera 24.0 24
Total daily energy 6024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:47

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 2158.59 kWh/year Performance Ratio PR 47.73 %
Available solar energy 3848.35 kWh/year Solar Fraction SF 98.17 %
Excess (unused) 1541.30 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 4.4 % Cycles SOW 98.0 %
Missing Energy 40.17 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
377.9
336.3
355.2
352.0
EUnused
kWh
179.5
156.7
157.3
157.9
E_Miss
kWh
2.03
0.00
1.15
0.00
E_User
kWh
184.7
168.7
185.6
180.7
E_Load
kWh
186.7
168.7
186.7
180.7
SolFrac
ratio
0.989
1.000
0.994
1.000
May 148.7 127.9 325.1 127.9 0.00 186.7 186.7 1.000
June 134.7 114.1 291.9 101.0 1.97 178.7 180.7 0.989
July 133.9 114.6 292.8 102.8 7.60 179.1 186.7 0.959
August 134.7 120.2 306.3 110.4 2.69 184.1 186.7 0.986
September 115.9 108.7 274.1 100.6 21.79 158.9 180.7 0.879
October 116.7 113.3 286.6 87.6 0.45 186.3 186.7 0.998
November 116.5 117.7 297.5 106.2 2.23 178.5 180.7 0.988

PVsyst TRIAL
December 133.8 138.6 352.6 153.4 0.25 186.5 186.7 0.999
Year 1612.6 1516.2 3848.3 1541.3 40.17 2158.6 2198.8 0.982

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:47

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 15 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

4383 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-38.85% Unused energy (battery full)

2425 kWh Effective energy at the output of the array

PVsyst TRIAL
Missing
-4.79%
-0.02%
-0.09%
0.00%
0.00%
Converter Loss during operation (efficiency)
Converter Loss over nominal conv. power
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
2307 kWh Converter losses (effic, overload)
energy
Direct use Stored Battery Storage
1.83% 2.1% 97.9%
-0.09% Battery Stored Energy balance
40.2 kWh
-5.16% Battery efficiency loss

-2.79% Charge/Disch. Current Efficiency Loss


-0.10% Battery Self-discharge Current

PVsyst TRIAL
2159 kWh Energy supplied to the user

2199 kWh Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:47

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Puerto Quito


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 2880 Wp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:51

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 7.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 9 units Technology Lithium-ion, LFP
Pnom total 2880 Wp Nb. of units 3 units
Voltage 53 V
Capacity 324 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 2531.16 kWh/year
Missing Energy
Excess (unused)
32.60 kWh/year
1019.96 kWh/year

Project and results summary


Specific production 879 kWh/kWp/year Perf. Ratio PR
Available solar energy 3824.36 kWh/year

Table of contents
Solar Fraction SF
55.96 %
98.73 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:51

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 7.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
3 in parallel
Number of PV modules 9 units Discharging min. SOC 10.0 %
Nominal (STC) 2880 Wp Stored energy 15.6 kWh
Modules 3 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 2708 Wp Nominal Capacity 324 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 40 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 2.88 kWp
Total 9 modules
Module area 15.3 m²
Cell area 13.6 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
27 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:51

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 7.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
carga 3 1 7000/lamp 1.0 7000
Consumidores en espera 24.0 24
Total daily energy 7024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:51

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 2531.16 kWh/year Performance Ratio PR 55.96 %
Available solar energy 3824.36 kWh/year Solar Fraction SF 98.73 %
Excess (unused) 1019.96 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 2.7 % Cycles SOW 98.7 %
Missing Energy 32.60 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
375.8
334.7
353.3
350.2
EUnused
kWh
132.5
119.2
116.6
115.3
E_Miss
kWh
0.00
0.00
0.00
0.00
E_User
kWh
217.7
196.7
217.7
210.7
E_Load
kWh
217.7
196.7
217.7
210.7
SolFrac
ratio
1.000
1.000
1.000
1.000
May 148.7 127.9 322.9 83.4 0.00 217.7 217.7 1.000
June 134.7 114.1 289.7 55.3 0.00 210.7 210.7 1.000
July 133.9 114.6 290.8 57.5 9.09 208.7 217.7 0.958
August 134.7 120.2 304.5 69.7 0.80 216.9 217.7 0.996
September 115.9 108.7 272.4 56.6 21.52 189.2 210.7 0.898
October 116.7 113.3 284.3 44.7 0.61 217.1 217.7 0.997
November 116.5 117.7 295.2 57.9 0.58 210.1 210.7 0.997

PVsyst TRIAL
December 133.8 138.6 350.5 111.3 0.00 217.7 217.7 1.000
Year 1612.6 1516.2 3824.4 1020.0 32.60 2531.2 2563.8 0.987

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:51

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 15 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

4383 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-25.71% Unused energy (battery full)

2947 kWh Effective energy at the output of the array

-4.75% Converter Loss during operation (efficiency)

PVsyst TRIAL
Missing
Direct use
2804 kWh
Stored
-0.02%
-0.08%
0.00%
0.00%
Converter Loss over nominal conv. power
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
Converter losses (effic, overload)
Battery Storage
energy 11.3% 88.7%
+0.08% Battery Stored Energy balance
1.27%
32.6 kWh
-8.80% Battery efficiency loss

-2.72% Charge/Disch. Current Efficiency Loss


-0.13% Battery Self-discharge Current

PVsyst TRIAL
2531 kWh Energy supplied to the user

2564 kWh Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC4, Simulation date:
17/07/23 08:51

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Puerto Quito


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 2880 Wp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC5, Simulation date:
17/07/23 08:54

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 8.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 9 units Technology Lithium-ion, LFP
Pnom total 2880 Wp Nb. of units 3 units
Voltage 53 V
Capacity 324 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 2802.48 kWh/year
Missing Energy
Excess (unused)
126.28 kWh/year
630.66 kWh/year

Project and results summary


Specific production 973 kWh/kWp/year Perf. Ratio PR
Available solar energy 3809.44 kWh/year

Table of contents
Solar Fraction SF
61.96 %
95.69 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC5, Simulation date:
17/07/23 08:54

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 8.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
3 in parallel
Number of PV modules 9 units Discharging min. SOC 10.0 %
Nominal (STC) 2880 Wp Stored energy 15.6 kWh
Modules 3 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 2708 Wp Nominal Capacity 324 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 40 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 2.88 kWp
Total 9 modules
Module area 15.3 m²
Cell area 13.6 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
27 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC5, Simulation date:
17/07/23 08:54

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 8.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
carga 4 1 8000/lamp 1.0 8000
Consumidores en espera 24.0 24
Total daily energy 8024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC5, Simulation date:
17/07/23 08:54

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 2802.48 kWh/year Performance Ratio PR 61.96 %
Available solar energy 3809.44 kWh/year Solar Fraction SF 95.69 %
Excess (unused) 630.66 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 8.8 % Cycles SOW 98.3 %
Missing Energy 126.28 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
374.4
333.3
351.9
348.6
EUnused
kWh
96.89
81.16
79.10
73.14
E_Miss
kWh
2.81
0.00
2.31
0.00
E_User
kWh
245.9
224.7
246.4
240.7
E_Load
kWh
248.7
224.7
248.7
240.7
SolFrac
ratio
0.989
1.000
0.991
1.000
May 148.7 127.9 321.4 43.32 0.00 248.7 248.7 1.000
June 134.7 114.1 288.6 23.17 9.74 231.0 240.7 0.960
July 133.9 114.6 289.7 29.14 20.97 227.8 248.7 0.916
August 134.7 120.2 303.4 40.75 13.18 235.6 248.7 0.947
September 115.9 108.7 271.7 41.42 42.97 197.7 240.7 0.821
October 116.7 113.3 283.3 21.10 16.67 232.1 248.7 0.933
November 116.5 117.7 294.2 32.15 17.63 223.1 240.7 0.927

PVsyst TRIAL
December 133.8 138.6 348.9 69.34 0.00 248.7 248.7 1.000
Year 1612.6 1516.2 3809.4 630.66 126.28 2802.5 2928.8 0.957

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC5, Simulation date:
17/07/23 08:54

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 15 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

4383 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-15.90% Unused energy (battery full)

3336 kWh Effective energy at the output of the array

-4.64% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.03% Converter Loss over nominal conv. power
-0.07% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold

Missing 3179 kWh Converter losses (effic, overload)


Direct use
energy Stored Battery Storage
8.3% 91.7%
-0.02% Battery Stored Energy balance
4.31%
126.3 kWh -10.62% Battery efficiency loss

-2.90% Charge/Disch. Current Efficiency Loss


-0.12% Battery Self-discharge Current
2802 kWh Energy supplied to the user

PVsyst TRIAL 2929 kWh Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC5, Simulation date:
17/07/23 08:54

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Puerto Quito


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3840 Wp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC6, Simulation date:
17/07/23 08:55

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 10.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 12 units Technology Lithium-ion, LFP
Pnom total 3840 Wp Nb. of units 4 units
Voltage 53 V
Capacity 432 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 3576.68 kWh/year
Missing Energy
Excess (unused)
82.08 kWh/year
1306.14 kWh/year

Project and results summary


Specific production 931 kWh/kWp/year Perf. Ratio PR
Available solar energy 5105.87 kWh/year

Table of contents
Solar Fraction SF
59.31 %
97.76 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC6, Simulation date:
17/07/23 08:55

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 10.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
4 in parallel
Number of PV modules 12 units Discharging min. SOC 10.0 %
Nominal (STC) 3840 Wp Stored energy 20.8 kWh
Modules 4 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 3611 Wp Nominal Capacity 432 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 53 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 3.84 kWp
Total 12 modules
Module area 20.4 m²
Cell area 18.1 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
20 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC6, Simulation date:
17/07/23 08:55

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 10.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
carga5 1 10000/lamp 1.0 10000
Consumidores en espera 24.0 24
Total daily energy 10024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC6, Simulation date:
17/07/23 08:55

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 3576.68 kWh/year Performance Ratio PR 59.31 %
Available solar energy 5105.87 kWh/year Solar Fraction SF 97.76 %
Excess (unused) 1306.14 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 2.4 % Cycles SOW 98.0 %
Missing Energy 82.08 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
501.1
446.9
471.6
467.6
EUnused
kWh
165.7
151.5
149.4
145.5
E_Miss
kWh
3.65
0.00
2.42
0.00
E_User
kWh
307.1
280.7
308.3
300.7
E_Load
kWh
310.7
280.7
310.7
300.7
SolFrac
ratio
0.988
1.000
0.992
1.000
May 148.7 127.9 431.3 103.6 0.00 310.7 310.7 1.000
June 134.7 114.1 387.3 71.7 1.87 298.9 300.7 0.994
July 133.9 114.6 388.2 74.7 14.99 295.8 310.7 0.952
August 134.7 120.2 406.3 85.2 4.72 306.0 310.7 0.985
September 115.9 108.7 363.8 84.8 45.17 255.6 300.7 0.850
October 116.7 113.3 379.7 54.2 4.06 306.7 310.7 0.987
November 116.5 117.7 394.1 79.4 5.21 295.5 300.7 0.983

PVsyst TRIAL
December 133.8 138.6 468.0 140.4 0.00 310.7 310.7 1.000
Year 1612.6 1516.2 5105.9 1306.1 82.08 3576.7 3658.8 0.978

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC6, Simulation date:
17/07/23 08:55

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 20 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

5844 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-24.69% Unused energy (battery full)

3983 kWh Effective energy at the output of the array

-4.52% Converter Loss during operation (efficiency)

PVsyst TRIAL
Missing
Direct use
3800 kWh
Stored
-0.04%
-0.06%
0.00%
0.00%
Converter Loss over nominal conv. power
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
Converter losses (effic, overload)
Battery Storage
energy0.3% 99.7%
+0.24% Battery Stored Energy balance
2.24%
82.1 kWh
-4.17% Battery efficiency loss

-2.89% Charge/Disch. Current Efficiency Loss


-0.12% Battery Self-discharge Current

PVsyst TRIAL
3577 kWh Energy supplied to the user

3659 kWh Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC6, Simulation date:
17/07/23 08:55

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Puerto Quito


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 5.76 kWp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC7, Simulation date:
17/07/23 08:59

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 12.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 18 units Technology Lithium-ion, LFP
Pnom total 5.76 kWp Nb. of units 5 units
Voltage 53 V
Capacity 540 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 4333.84 kWh/year
Missing Energy
Excess (unused)
54.92 kWh/year
3134.86 kWh/year

Project and results summary


Specific production 752 kWh/kWp/year Perf. Ratio PR
Available solar energy 7709.50 kWh/year

Table of contents
Solar Fraction SF
47.91 %
98.75 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC7, Simulation date:
17/07/23 08:59

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 12.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
5 in parallel
Number of PV modules 18 units Discharging min. SOC 10.0 %
Nominal (STC) 5.76 kWp Stored energy 26.0 kWh
Modules 6 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 5.42 kWp Nominal Capacity 540 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 80 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 6 kWp
Total 18 modules
Module area 30.5 m²
Cell area 27.2 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
14 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC7, Simulation date:
17/07/23 08:59

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 12.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
carga 6 1 12000/lamp 1.0 12000
Consumidores en espera 24.0 24
Total daily energy 12024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC7, Simulation date:
17/07/23 08:59

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 4333.84 kWh/year Performance Ratio PR 47.91 %
Available solar energy 7709.50 kWh/year Solar Fraction SF 98.75 %
Excess (unused) 3134.86 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 1.8 % Cycles SOW 98.5 %
Missing Energy 54.92 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
756.7
673.7
711.5
705.2
EUnused
kWh
364.1
319.7
321.6
321.6
E_Miss
kWh
0.00
0.00
0.00
0.00
E_User
kWh
372.7
336.7
372.7
360.7
E_Load
kWh
372.7
336.7
372.7
360.7
SolFrac
ratio
1.000
1.000
1.000
1.000
May 148.7 127.9 651.7 259.5 0.00 372.7 372.7 1.000
June 134.7 114.1 585.0 205.6 0.00 360.7 360.7 1.000
July 133.9 114.6 586.6 208.1 14.36 358.4 372.7 0.961
August 134.7 120.2 613.6 224.6 2.36 370.4 372.7 0.994
September 115.9 108.7 548.9 199.1 38.20 322.5 360.7 0.894
October 116.7 113.3 574.2 181.4 0.00 372.7 372.7 1.000
November 116.5 117.7 595.7 215.7 0.00 360.7 360.7 1.000

PVsyst TRIAL
December 133.8 138.6 706.5 313.9 0.00 372.7 372.7 1.000
Year 1612.6 1516.2 7709.5 3134.9 54.92 4333.8 4388.8 0.987

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC7, Simulation date:
17/07/23 08:59

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 31 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

8766 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-39.51% Unused energy (battery full)

4798 kWh Effective energy at the output of the array

PVsyst TRIAL
Missing
-4.58%
-0.02%
-0.08%
0.00%
0.00%
Converter Loss during operation (efficiency)
Converter Loss over nominal conv. power
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
4575 kWh Converter losses (effic, overload)
energy
Direct use Stored Battery Storage
1.25% 0.3% 99.7%
-0.05% Battery Stored Energy balance
54.9 kWh
-4.24% Battery efficiency loss

-2.83% Charge/Disch. Current Efficiency Loss


-0.13% Battery Self-discharge Current

PVsyst TRIAL
4334 kWh Energy supplied to the user

4389 kWh Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC7, Simulation date:
17/07/23 08:59

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Puerto Quito


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 4800 Wp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:02

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 14.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 15 units Technology Lithium-ion, LFP
Pnom total 4800 Wp Nb. of units 6 units
Voltage 53 V
Capacity 648 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 4885.69 kWh/year
Missing Energy
Excess (unused)
233.07 kWh/year
811.32 kWh/year

Project and results summary


Specific production 1018 kWh/kWp/year Perf. Ratio PR
Available solar energy 6340.18 kWh/year

Table of contents
Solar Fraction SF
64.81 %
95.45 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:02

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 14.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
6 in parallel
Number of PV modules 15 units Discharging min. SOC 10.0 %
Nominal (STC) 4800 Wp Stored energy 31.2 kWh
Modules 5 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 4514 Wp Nominal Capacity 648 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 67 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 4.80 kWp
Total 15 modules
Module area 25.4 m²
Cell area 22.7 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
16 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:02

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 14.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
carga7 1 14000/lamp 1.0 14000
Consumidores en espera 24.0 24
Total daily energy 14024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:02

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 4885.69 kWh/year Performance Ratio PR 64.81 %
Available solar energy 6340.18 kWh/year Solar Fraction SF 95.45 %
Excess (unused) 811.32 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 9.2 % Cycles SOW 98.5 %
Missing Energy 233.07 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
623.2
554.8
585.5
580.2
EUnused
kWh
141.9
115.4
108.4
101.1
E_Miss
kWh
10.96
0.00
3.51
0.00
E_User
kWh
423.8
392.7
431.2
420.7
E_Load
kWh
434.7
392.7
434.7
420.7
SolFrac
ratio
0.975
1.000
0.992
1.000
May 148.7 127.9 534.9 51.7 0.00 434.7 434.7 1.000
June 134.7 114.1 480.1 13.8 13.18 407.5 420.7 0.969
July 133.9 114.6 482.3 31.8 39.82 394.9 434.7 0.908
August 134.7 120.2 504.9 46.5 21.23 413.5 434.7 0.951
September 115.9 108.7 452.1 49.8 78.25 342.5 420.7 0.814
October 116.7 113.3 471.8 23.3 27.60 407.1 434.7 0.937
November 116.5 117.7 489.5 31.6 38.51 382.2 420.7 0.908

PVsyst TRIAL
December 133.8 138.6 580.8 95.8 0.00 434.7 434.7 1.000
Year 1612.6 1516.2 6340.2 811.3 233.07 4885.7 5118.8 0.954

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:02

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 25 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

7305 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-12.27% Unused energy (battery full)

5800 kWh Effective energy at the output of the array

-4.60% Converter Loss during operation (efficiency)

-0.03% Converter Loss over nominal conv. power

PVsyst TRIAL
Missing
Direct use
energy
8.1%
5529 kWh
Stored
91.9%
-0.07%
0.00%
0.00%

-0.04%
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
Converter losses (effic, overload)
Battery Storage
Battery Stored Energy balance
4.55%
233.1 kWh -10.51% Battery efficiency loss

-2.92% Charge/Disch. Current Efficiency Loss


-0.14% Battery Self-discharge Current
4886 kWh Energy supplied to the user

PVsyst TRIAL
5119 kWh Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:02

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Puerto Quito


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 6.72 kWp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:05

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 16.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 21 units Technology Lithium-ion, LFP
Pnom total 6.72 kWp Nb. of units 7 units
Voltage 53 V
Capacity 756 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 5785.63 kWh/year
Missing Energy
Excess (unused)
63.13 kWh/year
2626.20 kWh/year

Project and results summary


Specific production 861 kWh/kWp/year Perf. Ratio PR
Available solar energy 8932.13 kWh/year

Table of contents
Solar Fraction SF
54.82 %
98.92 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:05

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 16.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
7 in parallel
Number of PV modules 21 units Discharging min. SOC 10.0 %
Nominal (STC) 6.72 kWp Stored energy 36.4 kWh
Modules 7 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 6.32 kWp Nominal Capacity 756 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 93 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 7 kWp
Total 21 modules
Module area 35.6 m²
Cell area 31.8 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
12 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:05

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 16.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
carga 8 1 16000/lamp 1.0 16000
Consumidores en espera 24.0 24
Total daily energy 16024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:05

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 5785.63 kWh/year Performance Ratio PR 54.82 %
Available solar energy 8932.13 kWh/year Solar Fraction SF 98.92 %
Excess (unused) 2626.20 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 1.6 % Cycles SOW 98.8 %
Missing Energy 63.13 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
877.6
781.7
825.3
817.8
EUnused
kWh
327.3
301.3
296.7
291.5
E_Miss
kWh
0.00
0.00
0.00
0.00
E_User
kWh
496.7
448.7
496.7
480.7
E_Load
kWh
496.7
448.7
496.7
480.7
SolFrac
ratio
1.000
1.000
1.000
1.000
May 148.7 127.9 754.3 216.5 0.00 496.7 496.7 1.000
June 134.7 114.1 676.8 153.1 0.00 480.7 480.7 1.000
July 133.9 114.6 678.8 143.3 13.08 483.7 496.7 0.974
August 134.7 120.2 711.2 184.9 0.00 496.7 496.7 1.000
September 115.9 108.7 636.2 149.2 50.06 430.7 480.7 0.896
October 116.7 113.3 664.2 127.1 0.00 496.7 496.7 1.000
November 116.5 117.7 689.5 152.4 0.00 480.7 480.7 1.000

PVsyst TRIAL
December 133.8 138.6 818.7 282.9 0.00 496.7 496.7 1.000
Year 1612.6 1516.2 8932.1 2626.2 63.13 5785.6 5848.8 0.989

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:05

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 36 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

10227 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-28.37% Unused energy (battery full)

6629 kWh Effective energy at the output of the array

PVsyst TRIAL
-4.80% Converter Loss during operation (efficiency)

-0.02% Converter Loss over nominal conv. power


-0.08% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
6306 kWh Converter losses (effic, overload)
MissingDirect use Stored Battery Storage
energy 12.9% 87.1%
+0.15% Battery Stored Energy balance
1.08%
63.1 kWh
-7.32% Battery efficiency loss

-2.61% Charge/Disch. Current Efficiency Loss


-0.14% Battery Self-discharge Current

PVsyst TRIAL 5786 kWh

5849 kWh
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Puerto Quito
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC8, Simulation date:
17/07/23 09:05

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 8.64 kWp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
17/07/23 09:09

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 18.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 27 units Technology Lithium-ion, LFP
Pnom total 8.64 kWp Nb. of units 7 units
Voltage 53 V
Capacity 756 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 6506.07 kWh/year
Missing Energy
Excess (unused)
72.69 kWh/year
4683.21 kWh/year

Project and results summary


Specific production 753 kWh/kWp/year Perf. Ratio PR
Available solar energy 11563.58 kWh/year

Table of contents
Solar Fraction SF
47.95 %
98.90 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
17/07/23 09:09

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 18.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
7 in parallel
Number of PV modules 27 units Discharging min. SOC 10.0 %
Nominal (STC) 8.64 kWp Stored energy 36.4 kWh
Modules 9 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 8.13 kWp Nominal Capacity 756 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 120 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 9 kWp
Total 27 modules
Module area 45.8 m²
Cell area 40.8 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
9.0 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
17/07/23 09:09

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 18.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
carga 9 1 18000/lamp 1.0 18000
Consumidores en espera 24.0 24
Total daily energy 18024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
17/07/23 09:09

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 6506.07 kWh/year Performance Ratio PR 47.95 %
Available solar energy 11563.58 kWh/year Solar Fraction SF 98.90 %
Excess (unused) 4683.21 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 2.5 % Cycles SOW 98.4 %
Missing Energy 72.69 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
1135
1011
1067
1058
EUnused
kWh
545.8
478.7
481.1
481.3
E_Miss
kWh
0.00
0.00
0.73
0.00
E_User
kWh
558.7
504.7
558.0
540.7
E_Load
kWh
558.7
504.7
558.7
540.7
SolFrac
ratio
1.000
1.000
0.999
1.000
May 148.7 127.9 977 388.8 0.00 558.7 558.7 1.000
June 134.7 114.1 878 307.7 0.00 540.7 540.7 1.000
July 133.9 114.6 880 310.2 21.77 537.0 558.7 0.961
August 134.7 120.2 920 334.3 4.19 554.6 558.7 0.992
September 115.9 108.7 823 291.7 46.00 494.7 540.7 0.915
October 116.7 113.3 861 271.1 0.00 558.7 558.7 1.000
November 116.5 117.7 894 322.8 0.00 540.7 540.7 1.000

PVsyst TRIAL
December 133.8 138.6 1060 469.9 0.00 558.7 558.7 1.000
Year 1612.6 1516.2 11564 4683.2 72.69 6506.1 6578.8 0.989

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
17/07/23 09:09

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 46 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

13149 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-39.35% Unused energy (battery full)

7217 kWh Effective energy at the output of the array

PVsyst TRIAL
Missing
-4.58%
-0.02%
-0.08%
0.00%
0.00%
Converter Loss during operation (efficiency)
Converter Loss over nominal conv. power
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
6880 kWh Converter losses (effic, overload)
energy
Direct use Stored Battery Storage
1.10% 0.3% 99.7%
-0.07% Battery Stored Energy balance
72.7 kWh
-4.31% Battery efficiency loss

-2.83% Charge/Disch. Current Efficiency Loss


-0.12% Battery Self-discharge Current

PVsyst TRIAL
6506 kWh Energy supplied to the user

6579 kWh Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
17/07/23 09:09

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7
Version 7.3.2

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Nuevo Proyecto


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 8.64 kWp

PVsyst TRIAL Puerto Quito - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC1, Simulation date:
17/07/23 09:11

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Puerto Quito Latitude 0.12 °N Albedo 0.20
Ecuador Longitude -79.26 °W
Altitude 119 m
Time zone UTC-5

Meteo data
puerto Quito
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 20.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 27 units Technology Lithium-ion, LFP
Pnom total 8.64 kWp Nb. of units 8 units
Voltage 53 V
Capacity 864 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 7229.49 kWh/year
Missing Energy
Excess (unused)
79.27 kWh/year
3935.02 kWh/year

Project and results summary


Specific production 837 kWh/kWp/year Perf. Ratio PR
Available solar energy 11550.22 kWh/year

Table of contents
Solar Fraction SF
53.28 %
98.92 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 2/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC1, Simulation date:
17/07/23 09:11

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 20.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 320 Wp
PV Array Characteristics

Generic
HDT-60FH-320
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
5K3 module LV/HV 52V / 105 Ah
Lithium-ion, LFP
8 in parallel
Number of PV modules 27 units Discharging min. SOC 10.0 %
Nominal (STC) 8.64 kWp Stored energy 41.6 kWh
Modules 9 Strings x 3 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 53 V
Pmpp 8.13 kWp Nominal Capacity 864 Ah (C10)
U mpp 68 V Temperature Fixed 20 °C
I mpp 120 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 9 kWp
Total 27 modules
Module area 45.8 m²
Cell area 40.8 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.4 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
9.0 mΩ
1.5 % at STC

1.3 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.0 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 3/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC1, Simulation date:
17/07/23 09:11

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 20.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
carga 10 1 20000/lamp 1.0 20000
Consumidores en espera 24.0 24
Total daily energy 20024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 4/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC1, Simulation date:
17/07/23 09:11

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 7229.49 kWh/year Performance Ratio PR 53.28 %
Available solar energy 11550.22 kWh/year Solar Fraction SF 98.92 %
Excess (unused) 3935.02 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 1.3 % Cycles SOW 98.6 %
Missing Energy 79.27 kWh/year Static SOW 93.3 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
145.0
132.9
147.2
152.6
GlobEff
kWh/m²
149.5
132.4
140.5
138.7
E_Avail
kWh
1133
1011
1066
1058
EUnused
kWh
463.9
424.3
425.8
419.0
E_Miss
kWh
0.00
0.00
0.00
0.00
E_User
kWh
620.7
560.7
620.7
600.7
E_Load
kWh
620.7
560.7
620.7
600.7
SolFrac
ratio
1.000
1.000
1.000
1.000
May 148.7 127.9 977 326.3 0.00 620.7 620.7 1.000
June 134.7 114.1 878 247.9 0.00 600.7 600.7 1.000
July 133.9 114.6 879 250.0 24.44 596.3 620.7 0.961
August 134.7 120.2 919 276.3 3.55 617.2 620.7 0.994
September 115.9 108.7 821 225.8 51.29 549.4 600.7 0.915
October 116.7 113.3 860 209.1 0.00 620.7 620.7 1.000
November 116.5 117.7 891 257.1 0.00 600.7 600.7 1.000

PVsyst TRIAL
December 133.8 138.6 1058 409.5 0.00 620.7 620.7 1.000
Year 1612.6 1516.2 11550 3935.0 79.27 7229.5 7308.8 0.989

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 5/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC1, Simulation date:
17/07/23 09:11

PVsyst TRIAL
with v7.3.2

Loss diagram
1613 kWh/m² Global horizontal irradiation

-2.61% Global incident in coll. plane

-3.45% IAM factor on global

1516 kWh/m² * 46 m² coll. Effective irradiation on collectors

efficiency at STC = 18.94% PV conversion

13149 kWh Array nominal energy (at STC effic.)


-0.89% PV loss due to irradiance level

PVsyst TRIAL -5.93%

+0.39%

-1.40%

-1.92%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-33.06% Unused energy (battery full)

7965 kWh Effective energy at the output of the array

PVsyst TRIAL
-4.31% Converter Loss during operation (efficiency)

-0.06% Converter Loss over nominal conv. power


-0.05% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
7615 kWh Converter losses (effic, overload)
Missing
Direct use Stored Battery Storage
energy 11.7% 88.3%
+0.24% Battery Stored Energy balance
1.08%
79.3 kWh
-3.88% Battery efficiency loss

-2.49% Charge/Disch. Current Efficiency Loss


-0.12% Battery Self-discharge Current

PVsyst TRIAL 7229 kWh

7309 kWh
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 6/7
Project: Nuevo Proyecto
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC1, Simulation date:
17/07/23 09:11

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
17/07/23 PVsyst Evaluation mode Page 7/7