PalmCare plus
Handheld Pulse Oximeter (Ver 1.0)
www.ebionics.co.kr
CONTENTS
2
Before Using the Product ·····
Thank you for purchasing PalmCare plus(Handheld Pulse Oximeter) .
Contacts
For various services and product information, please feel free to
contact our salesperson at the following number.
For any questions about use or setup of the product, please contact the
following number.
Technical Support
3
Product Guarantee …
The product you have purchased comes with a 1-year warranty from the
purchasing date covering inferior materials and the manufacturing
process. For the disposable products, a warranty is given for 6 months
from the purchasing date or 6 months from its first use covering
inferior materials and the manufacturing process. This warranty cannot
be applied to consumption supplies such as the battery, external cables,
cradle and disposable accessories.
We are not responsible for any physical, financial and mental loss or
damage and direct or indirect expenses caused by, or resultant from,
accidental or special circumstances during the use of the product. The
warranty is limited to the repair or exchange of the product by the
authority of the company or the agency, for problems in materials or the
manufacturing process which occurred during use under normal
circumstances.
The company has no legal responsibility for the confirmation of services,
declarations or whole warranty beyond the warranty specified above,
which were supplied or will be supplied by the agency or the staff of the
company at their own discretion. The user cannot request the
company of services, declarations or whole warranty which were supplied
or will be supplied by the agency or the staff of the company at their own
discretion based on the statements above.
The contents of this warranty represent all other warranties indicated or
implied, and also represent all kinds of service- related responsibilities of
the product sellers for the product they sell.
The product was manufactured under strict quality controls and the
inspection process of the company. The indemnification standard for
product repair and exchange is according to the Economic Planning
Board notification “ Regulation for the indemnification of consumer
damage”
4
Symbols in the Manual …
Some symbols are used in this manual to help users or patients use
this product safely and appropriately and to prevent any risk to
patients or damage to materials. Please read and understand all
warnings and precautions.
Warning
5
Precautions for Use
6
▶ Standard operational conditions are as follows.
- Temperature : 10℃ ~ 40℃ (50 ~ 113℉)
- Altitude : 70 ~ 106Kpa
- Humidity : 30 ~ 85%
7
CAUTION
◈ The product may not work well when it is kept or operated beyond
the temperature and humidity specified.
◈ If you want to turn off the PalmCare plus while you’re operating,
please use the power switch where is the front of the product.
CAUTION
◈ Leakage, heating, ignition or rupture of the battery may cause fire
or injury.
Do not use batteries beyond those specified in this manual.
Do not short-circuit the battery and do not heat, disassemble,
or dispose of it in a fire.
Do not mix using the used battery with new batteries , different
kind of batteries, other company batteries
◈ When the product is not used for a long time, separate the
battery from the product.
◈ To ensure the lifecycle and safety of battery, please discharge the
battery and then charge perfectly again every six months.
Also time-worn battery exceed 24 months should be replaced.
◈ When the product has been moved, make sure to turn it off and
arrange the accessories in order. Injured cords or cables may
cause fire or electric shock.
8
Precautions for Electric Safety
Prior to operation of the equipment, make sure to check following itmes.
CAUTION
NOTE
9
Description of Palmcare plus
There are two types of probe to the Plamcare plus. One is reusable
probe and the other is disposable probe to apply neonate or pediatric
patient as well as single use to adult.
Pulse rate and arterial blood oxygen saturation are pleased on a LCD
display in the real time. Users can determine the alarm settings and
volume as needed via cont기 key panel on the front. PalmCare plus
gives the operator the ability to measure patient basic vital biometric
data.
10
Composition of PalmCare plus(Accessories)
Standard Accessories
SpO2
(1EA)
Operation
Adapter(1EA)
Manual
DC 5V 2A
(1EA)
Optional
① Disposable probe
② Extension cord 2.4m(8ft)
③ Cradle
④ USB(mini B TYPE) serial cable
11
How to Set PalmCare plus
equipment.
12
(3) Maintenance and Cleaning After Use
A. Keep the product cleans by cleaning it using a soft cloth at
least once a month. Do not use thinner, ethylene, oxidant or
lacquer since these may damage the product.
B. Keep the accessories clean of dust or foreign materials. For
cleaning, use a soft cloth and clinical alcohol.
C. Do not soak the accessories in liquid or detergents. Keep the
product and accessories out of any liquid.
D. For the protection of the environment, please contact the
agency you purchased the product from when you wish to
discard the Palmcare plus.
E. Our product can be used semipermanently. Please contact
our Customer Service dept. or any distributor and then replace
the parts , when wasting parts such as battery.
ⅷ. Make sure to not let any dirt or especially metallic objects from
13
ⅰ. To avoid electrical noise or disturbance, install the device away
completely.
For the protection of the environment, please contact the agency you
purchased the product from when you wish to discard the battery.
14
Components of Palmcare plus
15
(2) Right Side
16
(5) Back Side
CAUTION
◈ In order to avoid electrical shock, do not open the cover.
Disassembling of the equipment must be done only an by
service personnel who is authorized by BIONICS.
17
Description of Equipment Symbols
18
Screen Configuration
Initial screen is shown after system boot and test for about 3 seconds, if
you turn the power on.
※ PalmCare plus offers six kinds of initial screen as the following
pictures for the user’s convenience, initial screen displayed on
pressing power button can be set up differently.
※ Please refer the chapter 6 for how to set up each initial display mode.
- Vertical mode initial screen
(1)Large Wave Mode (2)Small Wave Mode
1
19
- Horizontal Mode initial screen
2
2
3
3
2
3
20
(Table1). Description of Screen Icon
Falling out the probe connection (Sensor Off) Blink every 1seconds
21
Function of the buttons
Each buttons on the PalmCare plus services more than two use
according to the screen. The use meaning for each screen is as
below chart.
Commonness for
all kind of the Power On/Off
screens.
22
Palmcare plus Basic Operation
(1) OPERATION
NOTE
◈ Push and hold the power button for 1~2 seconds when power off.
◈ Power off automatically when no inputting data for 1 minute when battery
mode.
23
Environment Setting of Equipment
Menu Setting
You can set the all menu pushing MENU button ( )
Step 2 Press the ENTER ( ) button and enter setup screen you want,
after making reverse turn item you want by using UP/DOWN
( / ) button.
Step 3 In case you want to return to the initial screen, press ECS ( )
Button.
24
Alarm Setting
The below screen will be shown if you press ENTER ( ) button,
after making reverse the item “ 1. Alarm Setting ” on the
environment setting screen of Palmcare plus.
Step 2 The SETUP screen can be returned if you press the ECS ( )
button after completed inputting Alarm setting.
Default
Range
Setting value
HI LOW HI LOW
※ The LOW+1 in the chart means low limit value +1, the HI-1 means high limit
value -1.
For example, if low limit value for HR is 55, the HI value range for HR can
be adjusted as some numbers between 56 to 299.On the contrary, if high
limit value for HR is 150, the LOW value range for HR can be adjusted as
some numbers between1 to 149.
25
The value range for SpO2 also can be applied of the same rule of setting
up HR value. The only difference is the high limit value can be “OFF”
This “OFF” means the measured SpO2 value beyond the high limit range
will not be checked for alarm.
After selecting “HR Low” (the digits in right side of the colon is
reversed) on the alarm setting screen, you can change the value as
you want by UP/DOWN
( / ) button And then press ENTER button. Now, you can
adjust the low pulse rate alarm limit like this.
After selecting “SPO2 High” ( the digits in right side of the colon is
reversed) on the alarm setting screen, you can change the value as
you want by UP/DOWN
( / ) button and then press ENTER button.
Now, You can adjust the high oxygen saturation alarm limit like this
26
Low SpO₂Alarm Limits Adjust Mode
After selecting “SPO2 Low” ( the digits in right side of the colon is
reversed) on the alarm setting screen, you can change the value as
you want by UP/DOWN
( / ) button and then press ENTER button.
Now, you can adjust the low oxygen saturation alarm limit like this.
After selecting “Info Alarm” ( the on/off in right side of the colon is
reversed) on the alarm setting screen, you can select on/off as you
want by UP/DOWN ( / ) button and then press ENTER
button.
Now, you can adjust how to turn on or off the information alarm like
this.
27
Alarm Suspend Time value setting
Alarm suspend time value means not to make any alarm sound during the
set time.
In other words, the user can make not to activate the alarm sound for a
while. The time can be adjusted as 1MIN/2MIN/3MIN/OFF
If the event caused the alarm will not be terminated during the set time,
the alarm sound will activate again.
※ The alarm will not ring if you set the Suspend Time as OFF, even
though the alarm occurs
※As this shape icon ( ) s displayed on the LCD of the initial screen
during Suspend time, you can find out that the current alarm is
suspended state.
After selecting Suspend Time( the value in right side of the colon is
reversed) on the alarm setting screen, you can adjust suspending
time as you want by UP/DOWN button ( / ) and then
press ESC button to return to the initial screen of the environment
setting.
28
Initial Display Setting Mode (Display Mode)
Step 1 You can enter to the initial display setting mode if you press ENTER
button ( ), after making a reverse the item “2. DISPLAY MODE”
on the environment setting (SETUP) screen .
Step 2 You can use UP/DOWN ( / ) for the item moving, and
ENTER
( ) button for your choice.
29
You can return automatically to the SETUP screen if you choose the
Step 3 mode by ENTER button. And if you want to cancel the selection and
return to the SETUP screen, you can go back to the SETUP screen with
ESC( ) button.
※ The initial display mode of PalmCare plus is Vertical Large Wave.
30
Screen Setting (Vertical/Horizontal)
You can enter to the initial display setting mode if you press ENTER
Step 1 button ( ), after making a reverse the item “3. LCD VIEW” on
the environment setting (SETUP) screen .
(1)Horizontal (2)Vertical
31
You can return automatically to the SETUP screen if you choose the
Step 3 mode by ENTER button. And if you want to cancel the selection and
return to the SETUP screen, you can go back to the SETUP screen
with ESC( ) button.
32
Sound Setting (Sound High/Low/Off)
The sound ON/OFF set up is used for the Heart Beating Sound (Peak Sound),
buttons sound which can be heard on pressing the buttons and turning on/off
the sound.
You can enter to the High/Low/Off setting mode if you press ENTER
Step 1 button ( ), after making a reverse the item “4.Sound Volume” on
the environment setting (SETUP) screen .
Step 2 You can use UP/DOWN ( / ) button for the item moving, and
ENTER ( ) button for your choice.
33
You can return automatically to the SETUP screen if you choose the
Step 3
mode by ENTER button. And if you want to cancel the selection and
return to the SETUP screen, you can go back to the SETUP screen with
ESC( ) button.
34
Delete the TREND
This item is used to delete all of the trend data which is saved in the internal
memory of Palmcare plus.
You can enter to the TREND DELETE setting mode if you press ENTER
Step 1 button ( ), after making a reverse the item “5.TREND DELET” on the
environment setting (SETUP) screen .
Step 2 You can use UP/DOWN ( / ) button for the item moving, and
ENTER ( ) button for your choice.
Step 3 You can return automatically to the SETUP screen if you choose the mode
by ENTER button. And if you want to cancel the selection and return to the
SETUP screen, you can go back to the SETUP screen with ESC( )
button.
35
CAUTION
◈ Please take a note that all of the trend data saved in the
inside of Palmcare can be deleted, if you select “YES”
36
Select Language
You can enter to the Select Language setting mode if you press ENTER
Step 1 button ( ), after making a reverse the item “6.Select Language” on
the environment setting (SETUP) screen.
Step 2 You can use UP/DOWN ( / ) button for the item moving, and
ENTER ( ) button for your choice.
37
Step 3 You can return automatically to the SETUP screen if you choose the mode
by ENTER button. And if you want to cancel the selection and return to the
SETUP screen, you can go back to the SETUP screen with ESC( )
button.
38
Information of Palmcare plus
Palmcare plus displays the simple information of this equipment on the LCD
like the manufacturer of Palmcare plus, Program version/name and etc.
You can check the information of Palmcare plus by pressing the ENTER
Step 1 button ( ) after making a reverse the item “7.Device Info”.
Step 2 You can use UP/DOWN ( / ) button for the item moving, and
ENTER ( ) button for your choice.
You can go back to the previous (SETUP screen) if you press ESC ( )
Step 3 button.
39
Trend Function PalmCare plus
Palmcare plus can show you the value at each time in the trend form which
has been measured for1hr, 12hr, 24hr, 48hr and 72hr of the patients oxygen
saturation (SpO2) and Pulse Rate (HR) That’s to say, you can examine and
print the long-term change and the previous data of the measurement value
of the patient (However, the printing is possible only in case of attaching the
printer on Palmcare plus.
If you want to examine the trend information on the initial screen, please
Step 1
press TREDN button ( ) then the following Trend printing screen will
be seen on the LCD .
40
① ② ③ ④
⑦
⑥
① It indicates the type of the trend being displayed on the curren screen.
② Time(hour: minute-It starts at 00:00) for initial trend saving time
③ Saved SpO₂value
④ Save HR Value
⑤ Event data which is saved by the user
⑥ Data mark which is saved by Medium Priority Alarm
⑦ Data mark which is saved by High Priority Alarm
Step 2 You can examine the Trend Data by pressing the UP/DOWN button
( / ) . Whenever pressing the TREDN button( ) one time,
you can check Trend information as below 다.
● 1 hour SpO2/ Pulse Rage Trend - mean value of the 1 minute unit
● 12 hours SpO2/ Pulse Rage Trend - mean value of the 5 minutes unit
● 24 hours SpO2/ Pulse Rage Trend - mean value of the 10 minutes
unit
● 48 hours SpO2/ Pulse Rage Trend - mean value of the 20 minutes
unit
● 72 hours SpO2/ Pulse Rage Trend - mean value of the 30 minutes unit
Step 3 You can go back to the initial screen if you press ESC button ( ) after
completing trend examination.
41
Measuring of SpO₂
Preparation before Measuring SpO₂
Step 1 Plug in the SpO₂probe to SpO connection port on upper side of Palmcare
plus .
Step 2 Turn the power on by pressing the power button ( ) PalmCare plus .
Attaching of Probe
42
(How to apply SpO₂finger probe)
CAUTION
◈ Make sure that you should carefully handle the sensor and cable.
Non-careful use of the probe may cause harm the sensitive
sensor. Be sure that the cable is protected against sharp things.
◈ If a patient suffers from a fever or a disorder in peripheral
circulation system, then the temperature of the skin goes up by 2
or 3 degrees.
◈ If the values for Oxyhemoglobin or Methemoglobin of a patient
are increased abnormally, the SpO2 data are not reliable.
◈ The disposable sensor should not be re-used for the same
patient on the same or different part of the body.
◈ In order to reuse disposable sensor, you should sterilize it
WARNING
◈ Using an SpO2 probe during MR imaging can cause severe
burns. To minimize this risk, ensure that the cable is positioned
so that no inductive loops are formed. If the probe does not
appear to be operating properly, remove it immediately from the
patient.
◈ Never apply an SpO2 probe at ambient temperatures higher than
37℃
◈ Do not use disposable probe on patients who have allergic
reactions to the adhesive
◈ Avoiding the probe placed on any extremity with an arterial
catheter, or intravascular venous infusion line.
◈ Make sure the sensor emitter light and is directly opposite each
other and that all of the light from the emitter passes through the
patient’s tissue.
43
Alarm Function
Palmcare plus is designed to provide various kinds of alarm for users
convenience. Users must read following carefully and treat proper manner
in the situation of alarm occurrence.
③ Information Alarm
Information Alarm informs the matters which the user should keep or the
abnormality occurrence during measuring by alarming
NOTE
① Standard Mode
44
5 times in 2 seconds. This alarm sound has a rhythm specified by the
international standards.
i. Heart beating : The pitch of beep sound will vary in accordance with
oxygen saturation value changes.
ii. In case the battery capacity is running out: when inside battery is
used instead of outside power source (DC adapter), the information
(warning) alarm will go off to alert the user, when the battery is
running out.
iii. In case of Measuring failure: When a sensor has slipped off, or
when a probe connector is pulled off from the equipment, or when
sensor is malfunctioning, the information alarm will go off.
② Visual Alarm …
Alarm Occurrence
In the event the alarm occurs, the measured value changed red color and
you can heard the alarm weaning sound at the same time.
45
Power & Battery Specifications
PalmCare plus can be operated DC power. It can be operated while on the
move by getting the power from the internal battery which ca be used again
by recharging with the DC adapter.
DC Adapter Power
Battery Power
The internal battery supplies the sources of electricity, if you separate the
Dc adapter from Palmcare plus.
- Recharging period : 1Houres 1H/2 Min(1CELL),3 hours (2CELL)
- Continuous operating time : 3 hours(1CELL: 1130mAh)- Standard
6hours (2CELL: 2260mAh)-Optional
NOTE
46
Both AC and DC power is used for PalmCare plus. Basically, AC power
is used and a rechargeable battery is available for portable use .
1. AC Power (110~240VAC)
If the AC power is connected to the main body of the product, If the
product is not being used, the power changes automatically to the
recharging mode.
A. Type of Adaptor
- Model : JMW110KA0500M03
– Input : 100~240V~, 50~60Hz
- Output : 5V(DC), 2Amps
- Manufacturer: BridgePower Corp.
CAUTION
◈ During operation using AC power, noise may occur in the
waveform. If this is the case, ground the product soundly.
◈ An AC power connection in a wet or damp area may cause electric
shock or fatal damage to the product.
◈ When you connect the adapter will charge the battery automatically
2. Battery Specifications
When the AC power is disconnected and the switch is turned on, the
power is supplied using the battery.
47
Recharging time: 1H 1H/2Min,3H(OP MODE),(2H,4H)(POWER OFF)
Use time : 180 Min,360 MIN
CAUTION
◈ When the battery is removed, all data can be reset. Only in case
the product is kept for long time, Remove the battery from the product
48
CUATION
◈ For the protection of the environment, please contact the agency you
purchased the product from when you wish to discard the battery.
◈ Contact the agency you purchased battery in case battery should be
changed.
◈ To ensure the lifecycle and safety of battery, please discharge the battery
and then charge perfectly again every six months.
Problem Solution
1. In case of the battery is discharged.
- Connect DC adapter.
Cannot turn the Power
2. Please check the connection of the switch, it happens
on.
when the switch junction is imperfect.
49
Product Specification
■ Display
■ Indicators
■ Measurement Range
SpO₂Saturation: 0 ~ 100 %
HR : 30 ~ 300 BPM
50
Default
Range
Setting Value
■
HI LOW HI LOW
Accuracy
■ Power Consumption
■ Battery
■ Output
■ Temperature Range
■ Humidity Range
51
■ SpO₂Sensor
■ Trend Memory
■ Physical Dimension
■ Standard Accessories
Finger Probe
5V, 2.0A DC Adapter
■ Optional Accessories
52
Product Warranty
Customer Name of
Information Hospital
Address
Name
Name of Distributor
0120
53
54