GENERAL NOTES:

1. ALL ELECTRICAL WORKS HEREIN SHALL BE EXCUTED ACORDING TO THE REQUIREMENTS OF THE NATIONAL BUILDING CODE
OF THE PHILIPPINES, THE PHILIPPINE ELECTRICAL CODE, THE RULES AND REGULATIONS OF THE LOCAL GOVERNMENT, THE
SCHEDULE OF LOADS AND COMPUTATION REQUIREMENTS OF THE POWER COMPANY (MERALCO) AND THE TELEPHONE COMPANY.

2.ALL CONDUITS AND ELECTRICAL FRAMES OF EQUIPMENT SHALL BE GROUNDED BY CONNECTING TO EQUIPMENT
RATING OUTLET SWITCHES GROUNDING CONDUCTOR OR TO WATER SERVICE PIPE.
CKT. TOTAL AMPERE NO. AND SIZE OF WIRE
NO. AMP AMP WATT LOAD AND CONDUIT
VOLT LIGHT C.O. OTHER S1 S2 S3 S4 3. ALL FEEDERS AND BRANCH CIRCUIT SHALL BE INSTALLED AS INDICATED PLANS, INDIVIDUAL BRANCH CIRCUITS SHALL NOT
FRAME TRIP
BE COMBINED IN THE SAME RACEWAY UNLESS SO INDICATED.
2-2.0 mm ² TW,
1 220 50 15 25 3 4 2 2500 11.36 15 mm Ø PVC 4. LIGHTING BRANCH CIRCUITS WITHOUT DESIGNATION SHALL BE 2-3.5mm² (#12 AWG) TW IN 15mm (1/2) Ø CONDUIT UNLESS
OTHERWISE NOTED.
2-2.0 mm ² TW,
2 220 50 15 25 3 4 1 2500 11.36 15 mm Ø PVC
5. CONVENIENCE OUTLET CIRCUITS SHALL BE 3-3.5mm² (#12 AWG) T IN 15mm (1/2) Ø UNLESS OTHERWISE NOTED.
2-3.5 mm ² TW,
3 220 50 20 12 2400 10.90 15 mm Ø PVC
6. ALL WIRING FOR PWER, LIGHTING, C.O., SHALL BE INTERMEDIATE METALLIC CONDUIT UNLESS NOTED OTHERWISE CONDUIT
PIPE EMBEDDED IN DIRECT CONTACT WITH THE SOIL SHALL BE COATED WITH ASPHALT PAINT, WRAPPED IN ASPHALT TAPE
2-3.5 mm ² TW, AND FINALLY ANOTHER COAT OF ASPHALT PAINT EXCEPT NOTED OTHERWISE.
4 220 50 20 13 2600 11.81 15 mm Ø PVC
7. MINIMUM SIZE OF WIRE FOR CONTROL CIRCUITS SHALL BE 20mm² (#14 AWG) TW.
20
1
2HP 2-3.5 mm ² TW,
5 220 50 1127 5.12
ACU 15 mm Ø PVC 8. ALL WIRING FOR TELEPHONE SHALL BE RIGID PVC NEMA TC-2 TYPE 40 EXCEPT NOTED.

220 20
1
2HP 2-3.5 mm ² TW, 9. MOUNTING HEIGHTS OF DEVICES SHALL BE AS DETAILED IN PLANS OR AS DETAILED BY THE ARCHITECT AND OR AS
6 50 1127 5.12
ACU 15 mm Ø PVC
FOLLOWS.
LOCAL SWITCHES_ _ _ _ _ _ _ _ _ _ _ 1.37 ABOVE FLOOR FINISH
1
2HP 2-3.5 mm ² TW,
7 220 50 20 1127 5.12 15 mm Ø PVC
RECEPTACLES_ _ _ _ _ _ _ _ _ _ _ _ 0.30 ABOVE FLOOR FINISH
ACU
_ _ _ _ _ _ _ _ _ _ _ _ 0.17 ABOVE COUNTER

20
2-3.5 mm ² TW,
8 220 50 1 6000 27.27 10. ADDITIONAL MATERIALS SPECIFICATION ASIDE FROM THOSE MENTIONED ELSEWHERE SHALL BE AS FOLLOWS OR
RANGE 15 mm Ø PVC 16mm Ø EYE BOLT
APPROVED EQUAL.
20 REF. 2-3.5 mm ² TW, 25mm Ø POWER SERVICE a. ELECTRICAL METALLICTUBING MATSUSHITA
9 220 50 1 500 2.27 15 mm Ø PVC ENTRANCE CAP b. INTERMEDIATE METALLIC CONDUIT MATSUSHITA
c. POLYVINYL CHLORIDE (PVC) NELTEX
2-3.5 mm ² TW,
10 220 50 20 SPARE 1500 6.81 d. WIRES AND CABLES PHELPS DODGE, AMERICAN
15 mm Ø PVC
WIRE AND CABLE
50 27 6 8 3 21,381 e. CIRCUIT BREAKERS, PANELS
ELEMENT, BOXES & ENCLOSURES WESTING HOUSE, G.E.
21,381 X 0.80= 77.75 VOLTAGE: 230 V, 1"Ø 2- WIRES MAINS: f. WIRING DEVICES NATIONAL
COMPUTATION= AMPS.
220 2 POLE, 100 AT 2-30 mm THW, 25 mm Ø RSC g. FLOURESCENT FIXTURES BALLAST ADVANCE UNIVERSAL
h. FLOURESCENT TUBES & STARTERS G.E., PHILIPS
i. FLOURESCENT LAMP HOLDERS LEVITON (SPRING-LOADED
OR SNAP- ON TYPE)
j. FLOURESCENT HOUSING NORTHERN HILL, AMCO

11. ALL ELECTRICAL WORKS SHALL BE UNDER DIRECT AND IMMEDIATE SUPERVISION OF DULY LICENSED ELECTRICAL ENGINEER.

LEGEND:

40W FLOURESCENT LAMP W/


ACRYLIC DIFFUSER, RECESSED
SERVICE KILOWATT-HOUR METER
ENTRANCE WALL MOUNTED KEYLESS PORCELAIN LAMP RECEPTACLE WITH
100W INCANDESCENT BULB UNLESS NOTED OTHERWISE
UTILITY BOX
2-14 mm² TW
1- 8.0 mm² TW 16W "PHILIPS" ENERGY SAVING LIGHT
25 mm Ø RSC

60 AMPS 25mm Ø CONDUIT LAMP DUPLEX WALL CONVENIENCE OUTLET 15A, 250V, PARALLEL SLOTS
THOSE MARK "C" MOUNTED ABOVE COUNTER
M
FINISH FLOOR LEVEL
2-14 mm² TW SINGLE CONVENIENCE OUTLET FOR ELECTRIC RANGE
15 A 15 A 1- 8.0 mm² TW 2P, 30A, 250V GROUNDING TYPE
LIGHTING LIGHTING 25 mm Ø RSC
1 2
20 A 20 A SINGLE CONVENIENCE OUTLET 2P, 15A, 250V GROUNDING TYPE FOR
C.O. C.O. R or F
3 4 REFRIGERATOR IF MARKED "R" & FOR FREEZER IF MARKED "F"
2 CONCRETE PEDESTAL DETAIL
1 1
2HP 20 A 20 A 2HP
ACU ACU
5 6 E 2 SCALE NTS.
SINGLE POLE TOGGLE SWITCH 15A, 300V, SMALL LETTER SUBSCRIPT INDICATES
1 S1
2HP 20 A 20 A LIGHT OR DEVICE CONTROLLED, NOTE: S ETC. INDICATE GANG SWITCHES
ACU RANGE
7 8
20 A 20 A
REF. SPARE
DOUBLE POLE TOGGLE SWITCH 15A, 300V, SMALL LETTER SUBSCRIPT INDICATES
FIN. GRADE LINE 9 10 S2
LIGHT OR DEVICE CONTROLLED, NOTE: S ETC. INDICATE GANG SWITCHES

S3 TRIPLE POLE TOGGLE SWITCH 15A, 300V, SMALL LETTER SUBSCRIPT INDICATES
LIGHT OR DEVICE CONTROLLED, NOTE: S ETC. INDICATE GANG SWITCHES

GROUND LIGHTING POWER

1 SINGLE LINE RISER DIAGRAM CIRCUIT RUN EMBEDDED IN CONCRETE WALL OR FLOOR HOMERUN TO PANEL
E2 SCALE NTS.
BOARD OR AS INDICATED, NUMBER OR ARROWS INDICATE NO.OF CIRCUIT
CATV. TEL. LAN

OWNER REVISION: NOTE:

DRAWINGS AND SPECIFICATIONS


SHEET NO:
AND OTHER CONTRACT DOCUMENTS
PRC REG DATE ISSUED PRC REG DATE ISSUED CADD BY: DULY SIGNED, STAMPED OR SEALED,
AS INSTRUMENTS OF SERVICE, ARE
THE INTELLECTUAL PROPERTY AND
DOCUMENTS OF THE ARCHITECT,

PROPOSED TWO STOREY RESIDENTIAL HOUSE CHECKED BY: WHETHER THE OBJECT FOR WHICH
THEY ARE MADE IS EXECUTED OR

PTR REG PLACE ISSUED PTR REG PLACE ISSUED BLK. 56, LOT 1, SOUTHSPRINGS RESIDENTIAL ESTATE,
CANLALAY, BINAN CITY LAGUNA
JOHN RAY PAMPANGA ANGUSTIA
& ANDREA AURIGUE FLORENTO APPROVED BY:
NOT. IT SHALL BE UNLAWFUL FOR
OTHER PROJECT OR BUILDINGS,
WHETHER EXECUTED PARTLY OR IN
WHOLE, WITHOUT THE WRITTEN
CONSENT OF ARCHITECTURE OR
E-2
AUTHOR OF SAID DOCUMENTS.

DATE: REPUBLIC ACT 9266