1 www.tind.co.th 02-559-0866-8
» GENERATOR 50 KW 3
» GENERATOR 160 KW 6
» GENERATOR 255 KW 10
» GENERATOR 320 KW 14
» GENERATOR 640 KW 18
» GENERATOR 100 KW 22
» GENERATOR 250 KW 25
» GENERATOR 320 KW 29
» GENERATOR 400 KW 33
www.tind.co.th 02-559-0866-8 2
GENERATOR 50 KW
ISO 14001:2004 ISO 9001:2008 OHSAS 18001:2007
SWT DIESEL GENERATOR SET SWT DIESEL GENERATOR SET SWT DIESEL GENERATOR SET
Standard Features
๏ All generator set comply with international design and quality standards, such as ISO8528 (GB/T2820-97), ISO3046,
BS.EN60034, BS5000, IEC34-1, GB755, VDE0530, CSA22-2, AS1359, and so on.
๏ Engine and alternator coupled with the compact base of structure steel, equipped with exhaust silencer and radiator.
๏ SWT designed controller IS900 and multiple circuit breaker as a standard configuration for single unit.
๏ One year limited warranty covers all systems and components.
>>Prime power
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power.
There is no limitation to the annual hours of operation and this model can supply 10% over-load power for 1 hour in 12 hours.
>> Standby power
There ratings are available at variable load in the event of a main power network failure for a maximum of 500 hours per year.
No overload is permitted.
3 www.tind.co.th 02-559-0866-8
GENERATOR 50 KW
Engine Specifications
Model
Specification YC4D90Z-D21
BASIC TECHNICAL DATA
Manufacturer YuChai
Engine type 4-cycle,turbocharged
Cylinder arrangement 4 cylinders in-line
Bore and stroke(mm) 108 x 115
Compression ratio 17.5:1
Displacement(L) 4.214
Estimated total weight (dry)(kg) 370
Engine rated speed(rpm) 1500
Prime power(kW) 60
Standby power(kW) 66
EXHAUST SYSTEM
Combustion air inlet flow(m 3/min).rate 3.9
Exhaust gas flow (m3 /min).rate 10.4
Maximum back pressure(kPa) 10
Exhaust gas temperature outlet (rate)( ํC) 442
COOLING SYSTEM
Total system capacity(with radiator)(L) 24.5
FUEL CONSUMPTION
fuel consumption ( g/kW·h ) 230
LUBRICATION SYSTEM
Total system capacity 11
ELECTRIC SYSTEM
Governor type electrical
Starter motor DC24V
NOTE:
All data is based on:
1. Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust
silencer; not included are battery charging alternator, fan, and optional driven components.
2. Engine operating with fuel corresponding to grade No. 2-D per ASTM D975.
3. ISO 3046, Part 1, Standard reference Condition of :
Barometric Pressure: 100 kPa (29.53 in Hg)
Air Temperature : 25 ํc (77 ํF); Altitude:110 m (361 ft); Relative Humidity:30%;
Air Intake Restriction: 254 mm H2O (10 in H2 O);Exhaust Restriction : 51 mm Hg (2 in Hg).
4. Backed by worldwide service network.
N/A : Not Available;
TBD: To Be Determined;
www.tind.co.th 02-559-0866-8 4
GENERATOR 50 KW
Alternator Specifications
FARADAY Alternator
Model FD2C
Specification Continuous capacity,125/40 ํC Rise.(KW/KVA)
Frequency and Speed 50HZ,1500RPM
380/220V(Ph-Ph/Ph-N) 50/62.5
400/230V 50 /62.5
415/240V 50/62.5
440/254V N/A
Rated power factor 0.8
Stator winding pitch 2/3
Maximum over -speed(Rev/Min) 2250
Insulation system Class H
Protection IP23
AVR model SX460
PMG Optional
Excitation Boost System(EBS) N/A
NOTE:
1. Alternators meet the requirement of BS EN 60034 and the relevant section of other international standards such
as BS5000,VDE 0530, NEMA MG1-32, IEC34, CSAC22.2-100, As1359, and other standards and certifications can be
considered on request.
2. Brushless alternator with brushless pilot exciter for excellent load response.
3. Backed by worldwide service network.
Option
◇Residential muffler
◇Battery float charger
◇Fuel filter/Water separator
◇Double wall fuel tank or enlarger capacity fuel tank
◇50 ํC radiator For tropical condition(open sets for optional, soundproof sets as a standard configuration)
◇Automatic Transfer Switch(ATS) panel
◇DEIF,COMAP,DEEPSEA or other famous brand controller
◇ABB,SCHNEIDER, SIEMENS or other famous brand circuit breaker
◇Generator set main breaker with adjustable earth leakage protection or with grounding protection
◇Engine auto oil level regulator
◇Engine manual oil drain pump
◇Engine return fuel cooling device
◇Engine Coolant heater/Oil heater/Fuel heater
◇Engine auto fuel filling system(pump) for generator set base fuel tank
◇Alternator anti-condensation heater
◇Alternator differential protection CT
◇Alternator winding or bearing temperature sensor-RTD/THERMISTOR/PT100
……
Other generator set accessories can be considered on request.
5 www.tind.co.th 02-559-0866-8
GENERATOR 160 KW
ISO 9001:2000 GENSET MODEL: SPW220
THAI INDUSTECH ENERGYS DIESEL
400/230V 3P4W
RPM1500 50Hz
Rating Range
Standby: kW 176
kVA 220
Prime: kW 160
kVA 200
WARRANTY
• Company provides one-source responsibility for the generator set and accessories. Each generating set has been
got through 1.5 hours Load test for running 0%,25%,50%,75%,100% and 110% load, all protective devices and
control function are simulated and checked before dispatch.
• Engine and Alternator are guaranteed for a period of 12months from the date of commissioning or 18 months
from shipping, whichever occurs first.
• Convenience for operation and maintenance, backed by global service network.
Prime power(P)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially
purchased power. There is no limitation to the annual hours of operation and this model can supply 10% over-load
power for 1 hour in 12 hours.
Standby power(S)
Standby power is defined as the maximum power available, under the agreed operating conditions, for which the
generating set is capable of delivering for up to 500h of operation per year.
www.tind.co.th 02-559-0866-8 6
GENERATOR 160 KW
DIESEL ENGINE
Engine Model 1106A - 70TAG4
BASIC TECHNICAL DATA FUEL CONSUMPTION
Manufacturer Perkins Power rating (best SFC)
Number of cylinders 6 Standby power(L/h) 49.4
Induction system Turbocharged and air charge 100% prime power(L/h) 45.8
cooled
Bore and stroke(mm) 1 05×1 35
Compression ratio 1 6:1
Engine weight, dry(kg) 743
TECHNICAL DATA COOLING SYSTEM
Engine speed(rpm) 1500 Total coolant capacity (L) 21
Gross engine Standby power (kW) 1 96.3 Maximum top tank temperature ( ํC ) 1 10
Prime power(kW) 1 78.9 Thermostat operating range( ํC ) 82-93
Combustion air flow(m 3/min) 1 2.6
Exhaust gas flow (max)(m 3/min) 34.9
Exhaust gas temperature outlet(max) 550 ELECTRIC SYSTEM
Alternator type 8SI
Alternator voltage (V) 12
Alternator output (A) 63
EXHAUST SYSTEM Starter motor voltage (V) 12
Starter motor power 4.2kW(E0421)/5.0kW(E0471)
Exhaust back pressure at maximum power (kpa) 6
NOTE:
All data is based on:
LUBRICATION SYSTEM 1. Engine operating with fuel system, water pump, lubricating
oil pump, air cleaner and exhaust silencer; not included are
battery charging alternator, fan, and optional driven
Total lubrication system capacity (dry engine) (L) 18 components.
Minimum oil capacity in sump (L) 12.5 2.Engine operating with fuel corresponding to grade No.D2
Maximum oil capacity in sump (L) 16.1 per ASTM D975.
Maximum continuous oil temperature (in rail) (°C) 125 3. ISO 3046, Part 1, Standard Reference Conditions of:
Barometric Pressure: 100 kPa (29.53 in Hg)
Air Temperature : 25 °C (77°F )
Altitude: 110 m (361 ft)
FUEL SYSTEM Relative Humidity: 30%
Air Intake Restriction: 254 mm H 2O (10 in H 2O)
Type of injection Mechanical
Maximum static pressure head (kPa) 50 Exhaust Restriction: 51 mm Hg (2 in Hg)
Priming pump type Manual N/A: Not Available
Maximum priming time (seconds) 90 TBD: To Be Determined
Fuel temperature at engine fuel pump inlet (°C) 85 CP: Continuous power
Maximum fuel flow (litres/min ) 3 FSP: Fuel stop power
Altitude: Derate 2.0% per 300 m ( 984 ft.) elevation above 1000m ( 3279 ft.) up to a maximum elevation of 2450m(8000 ft.).
More than 2450m(8000ft), please contacts with us or our dealer seek the help.
Temperat ure: Derate 6.0% per 11 °C(20°F) temperature above 40 °C(104 °F).
7 www.tind.co.th 02-559-0866-8
GENERATOR 160 KW
ALTERNATOR
NOTE: This drawing is provided for reference only and should not be used for
planning installation. Contact your local distributor for more detailed
information.
www.tind.co.th 02-559-0866-8 8
GENERATOR 160 KW
CONTROL SYSTEM
Deepsea DSE6120 (Standard controller for generators )
Control System: Key Benefits:
The DSE6120 Auto Mains (Utility) Failure Control Module are suitable for a Automatically transfers betweenmains (utility) and generator
wide variety of single gen-set applications. Increased input and outputexpansion capability via DSENet ®
Monitoring engine speed, oil pressure, coolant temperature, frequency, voltage, Hours counter provides accurate information for monitoring and
current, power and fuel level, the modules give comprehensive engine and maintenance periods
alternator protection. This isindicated on a large back-lit LCD text display via an User -friendly set-up and button layout for ease of use Multiple
array of warning, electrical trip and shutdown alarmsin multiple languages. parameters are monitored simultaneously which
Electronic J1939 (CAN) and non-electronic MPU and alternator sensing engine are clearly displayed on a large back-lit text display via multiple
support for diesel, gas and petrol engines all in one variant. With a number of languages
flexible inputs, outputs and protections, the modules can be easily adapted to
The module can be configuredto suit a wide range of Applications
suit a wide range of applications.
Through USB Communication both modules can be configured using the DSE Compatible with a wide range of CAN engines including Tier 4
Configuration Suite PC Software or through the module'sfront panel editor. Uses DSE Configuration Suite , PC Software for simplified
Using the DSE Configuration Suite PC Software the controller is easyto use and configuration
configure which allows alteration of operating parameters, sequences, timers Licence-free PC software
and alarms. IP65 rating (with optional gasket) offers increased resistance to
water ingress
Desc ription For Module DSE6120 :
9 www.tind.co.th 02-559-0866-8
GENERATOR 255 KW
ISO 9001:2000 GENSET MODEL: SCS350
THAI INDUSTECH ENERGYS DIESEL
380/220V 3P4W
RPM1500 50Hz
Rating Range
Standby: kW 280
kVA 350
Prime: kW 255
kVA 319
WARRANTY
• SUPERWATT Company provides one -source responsibility for the generator set and accessories. Each
SUPERWATT generating set has been got through 1.5 hours Load test for running 0%,25%,50%,75%,100%
and 110% load, all protective devices and control function are simulated and checked before dispatch .
• Engine and Alternator are guaranteed for a period of 12months from the date of commissioning or 18
months from shipping, whichever occurs first.
• Convenience for opera tion and maintenance, backed by global service network.
Prime power(P)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially
purchased power. There is no lim itation to the annual hours of operation and this model can supply 10%
over-load power for 1 hour in 12 hours.
Standby power(S)
Standby power is defined as the maximum power available, under the agreed operating conditions, for which
the generating set is capable of delivering for up to 500h of operation per year.
www.tind.co.th 02-559-0866-8 10
GENERATOR 255 KW
DIESEL ENGINE
Engine Model NTA855 -G 1 B
Altitude: Derate 2.0% per 300m (984 ft.) elevation above 1000m (3279 ft.) up to a maximum elevation of 2450m (8000 ft.).
More than 2450m(8000ft), ple ase contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 11 ํC (20 ํF ) temperature above 40 ํC (104 ํF ).
11 www.tind.co.th 02-559-0866-8
GENERATOR 255 KW
ALTERNATOR
Alternators meet the requirement of BS EN 60034
Alternator Brand STAMFORD and the relevant section of other international
Alternator Model HCI4 34ES standards such as BS5000, VDE 0530, NEMA MG1-32,
IEC34, CSAC22.2-100, As1359, and other standards
Frequency and Speed 50Hz/1500rpm and certifications can be considered on request.
Voltage (V) 380
Prime capacity(kVA) 325 The 2/3 pitch design avoids excessive neutral currents.
Prime power(kW) 260 With the 2/3 pitch a nd carefully selected pole and
Power efficiency (%) 93.6 tooth designs, ensures very low waveform distortion.
Voltage regulation ±1.0 %
Brushless alternator with brushless pilot exciter for
Rated power factor 0.8 excellent load response.
Winding type P2/3
The insulation system is class H, easy paralleling
Overspeed(rpm) 1800 with mains or other generators, standard 2/3 pitch
Sustained short circuit 300%(3IN):20S stator windings avoid excessive neutral currents.
Protection class IP23 Backed by worldwide service network.
www.tind.co.th 02-559-0866-8 12
GENERATOR 255 KW
CONTROL SYSTEM
Deepsea DSE6120 (Standard controller for generators)
Control System: Key Benefits :
The DSE6120 Auto Mains (Utility) FailureControl Module are suitable for a Automatically transfers between mains (utility) and generator
wide variety of single gen - set applications. Increased input and output expansion capability via DSENet ®
Monitoring engine speed, oilpressure, coolant temperature,frequency, voltage, Hours counter provides accurate information for monitoring and
current, power and fuel level, the modules give comprehensive engine and maintenance periods
alternator protection. This is indicated on a large back-lit LCD text display via an User-friendly set-up and button layout for ease of use Multiple
array of warning,electrical trip and shutdown alarmsin multiple languages. parameters are monitored simultaneously which
Electronic J1939 (CAN) and non-electronic MPU and alternator sensing engine are clearly displayed on a large back-lit text display via multiple
support for diesel, gas and petrol engines all in one variant. With a number of languages
flexible inputs, outputs and protections, themodules can be easily adapted to
The module can be configured to suit a wide range of Applications
suit a wide range of applications.
Through USB Communication both modules can be configured using the DSE Compatible with a wide range of CAN engines including Tier 4
Configuration Suite PC Software or through the module's front panel editor. Uses DSE Configuration Suite PC Software for simplified
Using the DSE Configuration Suite PC Software the controller is easy to use and configuration
configure which allows alteration of operating parameters, sequences, timers Licence-free PC software
and alarms. IP65 rating (with optional gasket) offers increased resistance to
water ingress
Desc ription For Module DSE6120 :
13 www.tind.co.th 02-559-0866-8
GENERATOR 320 KW
ISO 9001:2000 GENSET MODEL: SPW450
THAI INDUSTECH ENERGYS DIESEL 400/230V 3P4W
RPM1500 50Hz
Rating Range
Standby : kW 360
kVA 450
Prime: kW 320
kVA 400
www.tind.co.th 02-559-0866-8 14
GENERATOR 320 KW
DIESEL ENGINE
Engine Model 2206C-E13TAG3
BASIC TECHNICAL DATA CONSUMPTION
Manufacturer Perkins Power rating (best SFC)
Number of cylinders 6 Standby power(L/h) 94
Induction system Turbocharged and air-to-air 100% prime power(L/h) 85
charge cooled 75% prime power(L/h) 65
Bore and stroke(mm) 1 30×1 57 50% prime power(L/h) 46
Compression ratio 1 6.3 :1
Engine weight, dry(kg) 1 478
TECHNICAL DATA COOLING SYSTEM
Engine speed(rpm) 1500 Total coolant capacity (L) 51.4
Gross engine Standby power (kW) 368.4 Maximum top tank temperature ( ํC ) 104
Prime power(kW) 324.2 Thermostat operating range ( ํC ) 87-98
Combustion air flow(m 3/min) 25.2
Exhaust gas flow (max)(m 3/min) 67.3
Exhaust gas temperature outlet(max) 630 ELECTRIC SYSTEM
Alternator type 20SI 24 V/ 70A
Starter motor type 39MT 24V/ 7.8KW
EXHAUST SYSTEM
NOTE:
Exhaust back pressure for total system (kpa) 10 All data is based on:
1. Engine operating with fuel system, water pump, lubricating
oil pump, air cleaner and exhaust silencer; not included are
battery charging alternator, fan, and optiona l driven
components.
LUBRICATION SYSTEM 2.Engine operating with fuel corresponding to grade No. 2 -D
per ASTM D975.
Total lubrication system capacity (dry engine) (L) 40 3. ISO 3046, Part 1, Standard Reference Conditions of:
Minimum oil capacity in sump (L) 32.5 Barometric Pressure: 100 kPa (29.53 in Hg)
Air Temperature : 25 ํC (77 ํF )
Maximum oil capacity in sump (L) 38 Altitude: 110 m (361 ft)
Relative Humidity: 30%
Air Intake Restriction: 254 mm H 2O (10 in H 2O)
Exhaust Restriction: 51 mm Hg (2 in Hg)
FUEL SYSTEM N/A: Not Available
TBD: To Be Determined
Injection system MEUI CP: Continuous power
Maximum static pressure head 4m FSP: Fuel stop powe r
Governor type Electronic
Altitude: Derate 2.0% per 300m (984 ft.) elevation above 1000m (3279 ft.) up to a maximum ele vation of 2450m (8000 ft.).
More than 2450m(8000ft), please contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 11 ํC (20 ํF ) temperature above 40 ํC (104 ํF ).
15 www.tind.co.th 02-559-0866-8
GENERATOR 320 KW
ALTERNATOR
NOTE: This drawing is provided for reference only and should not be used for
planning installation. Contact your local distributor for more detailed
information.
www.tind.co.th 02-559-0866-8 16
GENERATOR 320 KW
Deepsea DSE6120 (Standard controller for generators )
Control System: Key Benefits :
The DSE6120 Auto Mains (Utility) Failure Control Module are suitable for a Automatically transfers between mains (utility) and generator
wide variety of single gen-set applications. Increased input and output expansion capability via DSENet ®
Monitoring engine speed, oil pressure, coolant temperature, frequency, voltage, Hours counter provides accurate information for monitoring and
current, power and fuel level, the modules give comprehensive engine and maintenance periods
alternator protection. This is indicated on a large back-lit LCD text display via an User -friendly set -up and button layout for ease of use Multiple
array of warning, electrical trip and shutdown alarms in multiple languages. parameters are monitored simultaneously which
Electronic J1939 (CAN) and non -electronic MPU and alternator sensing engine are clearly displayed on a large back-lit text display via multiple
support for diesel, gas and petrol engines all in one variant. With a number of languages
flexible inputs, outputs and protections, the modules can be easily adapted to
The module can be configured to suit a wide range of Applications
suit a wide range of applications.
Through USB Communication both modules can be configured using the DSE Compatible with a wide range of CAN engines including Tier 4
Configuration Suite PC Software or through the module'sfront panel editor. Uses DSE Configuration Suite PC Software for simplified
Using the DSE Configuration Suite PC Software the controller is easy to use and configuration
configure which allows alteration of operating parameters, sequences, timers Licence-free PC software
and alarms. IP65 rating (with optional gasket) offers increased resistance to
water ingress
Description For Module DSE6120 :
17 www.tind.co.th 02-559-0866-8
GENERATOR 640 KW
ISO 9001:2000
THAI INDUSTECH ENERGYS DIESEL GENSET MODEL: SPW880
400/230V 3P4W
3P4W
RPM1500 50Hz
Rating Range
Standby : kW 704
kVA 880
Prime: kW 640
kVA 800
ASSEMBLY
• The engine and alternator are close coupled by means of an SAE flange. A full torsional analysis has been
carried
Out to guarantee no harmful vibration will occur.
• Anti -vibration pads are affixed between engine alternator feet and the base frame. Thus ensuring complete
Vibration isolation of the rotating assemblies and enabling the machine to be placed on an uneven surface
without any detrimental effects.
• For durability and corrosion resistance, all iron and steel surfaces of canopy fabrications have been treated
for coating by grit blast cleaning. Then covered by special three layers painting which provides an excellent
corrosion resistant surface.
CONTROL SYSTEM AND PROTECTION
• Controllers are available for all applications. It contains DeepSea, Deif , Comap or other famous brands.
According to their different functions, the control systems can be specified into key start controller model,
automatic start control model and PCRC three remote control systems. See controller features inside.
WARRANTY
• SUPERWATT Company provides one -source responsibility for the gene rator set and accessories. Each
SUPERWATT generating set has been got through 1.5 hours Load test for running 0%,25%,50%,75%,100%
and 110% load, all protective devices and control function are simulated and checked before dispatch .
• Engine and Alternator are guaranteed for a period of 12months from the date of commissioning or 18
months from shipping, whichever occurs first.
• Convenience for operation and maintenance, backed by PERKINS global service network.
Prime power(P)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially
purchased power. There is no limitation to the annual hours of operation and this model can supply 10%
over-load power for 1 hour in 12 hours.
Standby power (S)
Standby power is defined as the maximum power available, under the agreed operating conditions, for which
the generating set is capable of delivering for up to 500h of operation per year.
www.tind.co.th 02-559-0866-8 18
GENERATOR 640 KW
DIESEL ENGINE
Engine Model 4006-23TAG3A
BASIC TECHNICAL DATA CONSUMPTION
Manufacturer Per k ins Power rating (best SFC)
Number of cylinders 6 Standby power(L/h) 194
Induction system Turbocharged and air -to-air charge cooled 100% prime power(L/h) 172
Bore and stroke (mm) 160 × 190 75% prime power(L/h) 130
Cubic capacity (L) 22.921 50% prime power(L/h) 90
Compression ratio 13.6 :1
Engine weight, dry(kg) 2524 COOLING SYSTEM
Pressure cap setting (kPa) 70
T ECHNICAL DATA
Thermostat operating range (°C) 71 -85
Engine speed(rpm) 1500
Gross engine Standby power(kW) 786 ELECTRIC SYSTEM
Prime power(kW) 705
Brake mean effective pressure( kPa) 2452
Mean piston speed(m/s) 9.5 Type Insulated return
Engine coolant flow( L/s) 10 Alternator output 55 amps at 28 volts at 20 °C ambient
Combustion air flow(m 3/min) 69 Engine stop solenoid (V) 24
Exhaust gas flow(max)(m 3/min) 193 Starter motor power (Kw) 7.5
Exhaust gas temperature outlet(max) 500
Altitude: Derate 2.0% per 300m (984 ft.) elevation above 1000m (3279 ft.) up to a maximum elevation of 2450m (8000 ft.).
More than 2450m(8000ft), please contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 11 °C (20°F ) temperature above 40 °C (104 °F ).
19 www.tind.co.th 02-559-0866-8
GENERATOR 640 KW
ALTERNATOR
Alternators meet the requirement of BS EN 60034
Alternat or Brand Stamford and the relevant section of other international
Alternator M odel S6L1D -C4 standards such as BS5000, VDE 0530, NEMA MG1 -32,
Frequency and Speed 50Hz/1500rpm IEC34, CSAC22.2-100, As1359, and other standards
and certifications can be considered on request.
Voltage (V) 400
Prime capacity(kVA) 81 0 The 2/3 pitch design avoids excessive neutral
currents.
Prime power(kW) 648 With the 2/3 pitch and carefully selected pole and
Power efficiency(%) 94.4 tooth designs, ensures very low waveform distortion.
Voltage regulation ±0.5%
Brushless alternator with brushless pilot exciter for
Rated power factor 0.8 excellent load response.
Stator winding P2/3
The insulation system is class H, easy parallelling
Overspeed (rpm) 1800 with mains or other generators, standard 2/3 pitch
Sustained short circuit 300%(3IN):20S stator windings avoid excessive neutral currents.
Protection class IP23 Backed by worldwide service network
CONTAINERIZED
Containerized 20' Container
Weight (radiator model), net, kg 9220
NOTE: This drawing is provided for reference only and should not be used for
planning installation. Contact your local distributor for more detailed
information.
www.tind.co.th 02-559-0866-8 20
GENERATOR 640 KW
Deepsea DSE6120 (Standard controller for generators )
Control System: Key Benefits :
The DSE6120 Auto Mains (Utility) Failure Control Module are suitable for a Automatically transfers betweenmains (utility) and generator
wide variety of single gen -set applications. Increased input and outputexpansion capability via DSENet ®
Monitoring engine speed, oil pressure, coolant temperature, frequency, voltage, Hours counter provides accurate information for monitoring and
current, power and fuel level, the modules give comprehensive engine and maintenance periods
alternator protection. This isindicated on a large back-lit LCD text display via an User -friendly set-up and button layout for ease of use Multiple
array of warning, electrical trip and shutdown alarmsin multiple languages. parameters are monitored simultaneously which
Electronic J1939 (CAN) and non - electronic MPU and alternator sens ing engine are clearly displayed on a large back-lit text display via multiple
support for diesel, gas and petrol engines all in one variant. With a number of languages
flexible inputs, outputs and protections, the modules can be easily adapted to
The module can be configuredto suit a wide range of Applications
suit a wide range of applications.
Through USB Communication both modules can be configured using the DSE Compatible with a wide range of CAN engines including Tier 4
Configuration Suite PC Software or through the module's front panel editor. Uses DSE Configuration Suite PC Software for simplified
Using the DSE Configuration Suite PC Software the controller is easyto use and configuration
configure which allows alteration of operating parameters, sequences, timers Licence-free PC software
and alarms. IP65 rating (with optional gasket) offers increased resistance to
water ingress
Description For Module DSE6120 :
21 www.tind.co.th 02-559-0866-8
GENERATOR 100 KW
Standard Features
All generator set comply with international design and quality standards, such as ISO8528 (GB/T2820-97),
ISO3046,
BS.EN60034, BS5000, IEC34-1, GB755, VDE0530, CSA22 -2, AS1359, and so on.
Engine and alternator coupled with the compact base of structure steel, equipped with exhaust silencer and
radiator.
SWT designed controller IS900 and multiple circuit breaker as a standard configuration for single unit.
O ne year limited warranty covers all systems and components.
>>Prime power
These ratings are applicable forsupplying continuous electrical power (at variable load) in lieu of commercially purchasedpower. There is no
limitation to the annual hours of operation and this model can supply 10% over-load power for 1 hour in 12 hours.
>> Standby power
There ratings are available at variable load in the event of a main power network failure for a maximum of 500 hours per year. No overload is
permitted.
www.tind.co.th 02-559-0866-8 22
GENERATOR 100 KW
NOTE:
All data is based on:
1. Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer; not
included are battery charging alternator, fan, and optional driven components.
2. Engine operating with fuel corresponding to grade No. 2 -D per ASTM D975.
3. ISO 3046, Part 1, Standard Reference Conditions of:
Barometric Pressure: 100 kPa (29.53 in Hg)
Air Temperature : 25 ํC (77 ํF); Altitude:110 m (361 ft); Relative Humidity:30%;
Air Intake Restriction: 254 mm H2O (10 in H 2O);Exhaust Restriction : 51 mm Hg (2 in Hg).
4. Backed by worldwide service network .
N/A : Not Available;
TBD: To Be Determined;
23 www.tind.co.th 02-559-0866-8
GENERATOR 100 KW
Alternator Specifications
FARADAY Alternator
Model FD3C
S pecification Continuous capacity,125/40 ํC Rise.(KW/KVA)
Frequency and Speed 50HZ,1500RPM
380/220V(Ph-Ph/Ph -N) 100/125
400/230V 100/125
415/240V 100/125
440/254V N/A
Rated power factor 0.8
Stator winding pitch 2/3
Maximum over-speed(Rev/Min) 2250
Insulation system Class H
Protection IP23
AVR model SX460
PMG Optional
Excitation Boost System(EBS) N/A
NOTE:
1. Alternator s meet the requirement of BS EN 60034 and the relevant section of other international standards such as
BS5000, VDE 0530, NEMA MG1 -32, IEC34, CSAC22.2-100, As1359, and other standards and certifications can be
considered on request.
2. Brushless alternator with brushless pilot exciter for excellent load response.
3. Backed by worldwide service network .
Option
◇Residential muffler
◇Battery float charger
◇Fuel filter/Water separator
◇Double wall fuel tank or enlarger capacity fuel tank
◇50℃℃radiator For tropical condition(open sets for optional, soundproof sets as a standard configuration)
◇Automatic Transfer Switch(ATS) panel
◇DEIF,COMAP,DEEPSEA or other famous brand controller
◇ABB,SCHNEIDER, SIEMENS or other famous brand circuit breaker
◇Generator set main breaker with adjustable earth leakage protection or with grounding protection
◇Engine auto oil level regulator
◇Engine manual oil drain pump
◇Engine return fuel cooling device
◇Engine Coolant heater/Oil heater/Fuel heater
◇Engine auto fuel filling system(pump) for generator set base fuel tank
◇Alternator anti -condensation heater
◇Alternator differential protection CT
◇Alternator winding or bearing temperature sensor -RTD/THERMISTOR/PT100
www.tind.co.th 02-559-0866-8 24
GENERATOR 250 KW
ISO 9001:2000 GENSET MODEL: SPW343
THAI INDUSTECH ENERGYS DIESEL 400/230V 3P4W
RPM1500 50Hz
Rating Range
Standby : kW 275
kVA 343
Prime: kW 250
kVA 31 2
ASSEMBLY
• The engine and alternator are close coupled by means of an SAE flange. A full torsional analysis has been
carried Out to guarantee no harmful vibration will occur.
• Anti -vibration pads are affixed between engine alternator feet and the base frame. Thus ensuring complete
Vibration isolation of the rotating assemblies and enabling the machine to be placed on an uneven surface
without any detrimental effects.
• For durability and corrosion resistance, all iron and steel surfaces of canopy fabrications have been
treated for coating by grit blast cleaning. Then covered by special three layers painting which provides
an excellent corrosion resistant surface.
WARRANTY
• SUPERWATT Company provides one -source responsibility for the generator set and accessories. Each
SUPERWATT generating set has been got through 1.5 hours Load test for running 0%,25%,50%,75%,100%
and 110% load, all protective devices and control function are simulated and checked before dispatch .
• Engine and Alternator are guaranteed for a period of 12months from the date of commissioning or 18
months from shipping, whiche ver occurs first.
• Convenience for operation and maintenance, backed by global service network.
Prime power(P)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially
purchased power. There is no limitation to the annual hours of operation and this model can supply 10%
over-load power for 1 hour in 12 hours.
Standby power (S)
Standby power is defined as the maximum power available, under the agreed operating conditions, for which
the generating set is capable of delivering for up to 500h of operation per year.
25 www.tind.co.th 02-559-0866-8
GENERATOR 250 KW
DIESEL ENGINE
Altitude: Derate 2.0% per 300 m (984 ft.) elevation above 1000 m (3279 ft.) up to a maximum elevation of 2450m (8000 ft.).
More than 2450m(8000ft), please contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 1 1 ํC (20 ํF ) temperature above 40 ํC (104 ํF ).
www.tind.co.th 02-559-0866-8 26
GENERATOR 250 KW
ALTERNATOR
Alternators meet the requirement of BS EN 60034
Alternator Brand Stamford and the relevant section of other international
Alternator Model HCI444ES standards such as BS5000, VDE 0530, NEMA MG1 -32,
Frequency and Speed 50Hz/1500rpm IEC34, CSAC22.2 -100, As1359, and other standards
and certifications can be considered on request.
Voltage (V) 400
Prime capacity(kVA) 325 The 2/3 pitch design avoids excessive neutral
currents.
Prime power(kW) 260 With the 2/3 pitch an d carefully selected pole and
Power efficiency(%) 93.7 tooth designs, ensures very low waveform distortion.
Voltage regulation ± 1 .0%
Brushless alternator with brushless pilot exciter for
Rated power factor 0.8 excellent load response.
winding type P2/3
The insulation system is class H, easy paralleling
Overspeed (rpm) 2250 with mains or other generators, standard 2/3 pitch
Sustained short circuit 300%(3IN): 20S stator windings avoid excessive neutral currents.
Protection class IP23 Backed by worldwide service network .
NOTE: This drawing is provided for ref erence only and should not be used for
planning installation. Contact your local distributor for more detailed information.
27 www.tind.co.th 02-559-0866-8
GENERATOR 250 KW
CONTROL SYSTEM
Deepsea DSE6120 (Standard controller for generators)
Control System: Key Benefits :
The D SE6120 Auto Mains (Utility) Failure Control Module are suitable for a Automatically transfers between mains (utility) and generator
wide variety of single gen -set applications. Increased input and output expansion capability via DSENet ®
Monitoring engine speed, oil pressure, coolant temperature, frequency, voltage, Hours counter provides accurate information for monitoring and
current, power and fuel level, the modules give comprehensive engine and main tenance periods
alternator protection. This is indicated on a large back -lit LCD text display via an User -friendly set -up and button layout for ease of use Multiple
array of warning, electrical trip and shutdown alarms in multiple languages. parameters are monitored simultaneously which
Electronic J1939 (CAN) and non -electronic MPU and alternator sensing engine are clearly displayed on a large back -lit text display via multiple
suppor t for diesel, gas and petrol engines all in one variant. With a number of languages
flexible inputs, outputs and protections, the modules can be easily adapted to
The module can be configured to suit a wide range of Applications
suit a wide range of applications.
Through USB Communication both modules can be configured using the DSE Compatible with a wide range of CAN engines including Tier 4
Configuration Suite PC Software or through the module's front panel editor. Uses DSE Configuration Suite PC Software for simplified
Using the DSE Configuration Suite PC Software the controller is easy to use and configuration
configure which allows alteration of operating parameters, sequences, timers Licence -free PC software
and alarms. IP65 rating (with optional gasket) offers increased resistance to
water ingress
Desc ription For Module DSE6120 :
www.tind.co.th 02-559-0866-8 28
GENERATOR 320 KW
ISO 9001:2000 GENSET MODEL: SPW450
THAI INDUSTECH ENERGYS DIESEL 400/230V 3P4W
RPM1500 50Hz
Rating Range
Standby : kW 360
kVA 450
Prime: kW 320
kVA 400
ASSEMBLY
• The engine and alternator are close coupled by means of an SAE flange. A full torsional analysis has been
carried
Out to guarantee no harmful vibration will occur.
• Anti -vibration pads are affixed between engine alternator feet and the base frame. Thus ensuring complete
Vibration isolation of the rotating assemblies and enabling the machine to be placed on an uneven surface
without any detrimental effects.
• For durability and corrosion resistance, all iron and steel surfaces of canopy fabrications have been treated
for coating by grit blast cleaning. Then covered by special three layers painting which provides an excellent
corrosion resistant surface.
CONTROL SYSTEM AND PROTECTION
• Controllers are available for all applications. It contains DeepSea, Deif, Comap or other famous brands.
According to their different functions, the control systems can be specified into key start controller model,
automatic start control model and PCRC three remote control systems. See controller features inside.
WARRANTY
• SUPERWATT Company provides one -source responsibility for the generator set and accessories. Each
SUPERWATT generating set has been got through 1.5 hours Load test for running 0%,25%,50%,75%,100%
and 110% load, all protective devices and control function are simulated and checked before dispatch.
• Engine and Alternator are guaranteed for a period of 12months from the date of commissioning or 18
months from shipping, whiche ver occurs first.
• Convenience for operation and maintenance, backed by global service network.
Prime power(P)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially
purchased power. There is no limitation to the annual hours of operation and this model can supply 10%
over-load power for 1 hour in 12 hours.
Standby power (S)
Standby power is defined as the maximum power available, under the agreed operating conditions, for which
the generating set is capable of delivering for up to 500h of operation per year.
29 www.tind.co.th 02-559-0866-8
GENERATOR 320 KW
DIESEL ENGINE
Engine Model 2206C -E13TAG3
EXHAUST SYSTEM
NOTE:
Exhaust back pressure for total system (kpa) 10 All data is based on:
1. Engine operating with fuel system, water pump, lubricating
oil pump, air cleaner and exhaust silencer; not included are
battery charging alternator, fan, and optiona l driven
components.
LUBRICATION SYSTEM 2.Engine operating with fuel corresponding to grade No. 2-D
per ASTM D975.
Total lubrication system capacity (dry engine) (L) 40 3. ISO 3046, Part 1, Standard Reference Conditions of:
Minimum oil capacity in sump (L) 32.5 Barometric Pressure: 100 kPa (29.53 in Hg)
Air Temperature : 25 ํC (77 ํF )
Maximum oil capacity in sump (L) 38 Altitude: 110 m (361 ft)
Relative Humidity: 30%
Air Intake Restriction: 254 mm H 2O (10 in H 2 O)
Exhaust Restriction: 51 mm Hg (2 in Hg)
FUEL SYSTEM N/A: Not Available
TBD: To Be Determined
Injection system MEUI CP: Continuous power
Maximum static pressure head 4m FSP: Fuel stop powe r
Governor type Electronic
Altitude: Derate 2.0% per 300m (984 ft.) elevation above 1000m (3279 ft.) up to a maximum ele vation of 2450m (8000 ft.).
More than 2450m(8000ft), please contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 11 ํC (20 ํF ) temperature above 40 ํC (104 ํF ).
www.tind.co.th 02-559-0866-8 30
GENERATOR 320 KW
ALTERNATOR
Alternator Brand Stamford Alternators meet the requirement of BS EN 60034
and the relevant section of other international
Alternator Model S4L 1D -F41 standards such as BS5000, VDE 0530, NEMA MG1 -32,
Frequency and Speed 50Hz/1500rpm IEC34, CSAC22.2-100, As1359, and other standards
Voltage (V) 400 and certifications can be considered on request.
Prime capacity(kVA) 415 The 2/3 pitch design avoids excessive neutra l
Prime power(kW) 332 currents.
With the 2/3 pitch and carefully selected pole and
Power efficiency (%) 93.2 tooth designs, ensures very low waveform distortion.
Voltage regulation ±1.0 %
Rated power factor Brushless alternator with brushless pilot exciter for
0.8 excellent load response.
winding type P2/3
Overspeed(rpm) 2250 The insulation system is class H, easy paralleling
with mai ns or other generators, standard 2/3 pitch
Sustained short circuit 300%(3IN):20S stator windings avoid excessive neutral currents.
Protection class IP23
Backed by worldwide service network .
NOTE: This drawing is provided for reference only and should not be used for
planning installation. Contact your local distributor for more detailed information.
31 www.tind.co.th 02-559-0866-8
GENERATOR 320 KW
CONTROL SYSTEM
Deepsea DSE6120 (Standard controller for generators )
Control System: Key Benefits :
The DSE6120 Auto Mains (Utility) Failure Control Module are suitable for a Automatically transfers between mains (utility) and generator
wide variety of single gen-set applications. Increased input and output expansion capability via DSENet ®
Monitoring engine speed, oil pressure, coolant temperature, frequency, voltage, Hours counter provides accurate information for monitoring and
current, power and fuel level, the modules give comprehensive engine and maintenance periods
alternator protection. This is indicated on a large back-lit LCD text display via an User -friendly set-up and button layout for ease of use Multiple
array of warning, electrical trip and shutdown alarms in multiple languages. parameters are monitored simultaneously which
Electronic J1939 (CAN) and non -electronic MPU and alternator sensing engine are clearly displayed on a large back-lit text display via multiple
support for diesel, gas and petrol engines all in one variant. With a number of languages
flexible inputs, outputs and protections, the modules can be easily adapted to
The module can be configured to suit a wide range of Applications
suit a wide range of applications.
Through USB Communication both modules can be configured using the DSE Compatible with a wide range of CAN engines including Tier 4
Configuration Suite PC Software or through the module'sfront panel editor. Uses DSE Configuration Suite PC Software for simplified
Using the DSE Configuration Suite PC Software the controller is easy to use and configuration
configure which allows alteration of operating parameters, sequences, timers Licence-free PC software
and alarms. IP65 rating (with optional gasket) offers increased resistance to
water ingress
Description For Module DSE6120 :
www.tind.co.th 02-559-0866-8 32
GENERATOR 400 KW
ISO 9001:2000 GENSET MODEL: SPS550
THAI INDUSTECH ENERGYS DIESEL
380/440V 3P4W
RPM1500 50Hz
Rating Range
Standby : kW 440
kVA 550
Prime: kW 400
kVA 500
ASSEMBLY
• The engine and alternator are close coupled by means of an SAE flange . A full torsional analysis has been
carried
Out to guarantee no harmful vibration will occur.
• Anti -vibration pads are affixed between engine alternator feet and the base frame. Thus ensur ing complete
Vibration isolation of the rotating assemblies and enabling the machine to be placed on an uneven surface
without any detrimental effects.
• For durability and corrosion resistance, all iron and steel surfaces of canopy fabrications have been treated
for
coating by grit blast cleaning. Then covered by special three layers painting which provides an excellent
corrosion resistant surface.
CONTROL SYSTEM AND PROTECTION
• Controllers are available for all applications. It contains Deep Sea, Delf, Comap or other famous brands.
According to their different functions, the control systems can be specified into key start controller model,
automatic start control model and PCRC three remote control systems. See controller features inside.
WARRANTY
• SUPERWATT Company provides one -source responsibility for the generator set and accessories. Each
SUPERWATT generating set has been got through 1.5 hours Load test for running 0%,25%,50%,75%,100%
and 110% load, all protective devices and control functio n are simulated and checked before despatch.
• Engine and Alternator are guaranteed for a period of 12months from the date of commissioning or 18
months from shipping,whichever occurs first.
• Convenience for operation and maintenance, backed by global service network.
Prime power(P)
These ratings are applicable for supplying continuous electrical power(at variable load) in lieu of commercially
purchased power. There is no limitation to the annual hours of operation and this model can supply 10%
over-load power for 1 hour in 12 hours.
Standby power (S)
Standby power is defined as the maximum power available, under the agreed operating conditions, for which
the generating set is capable of delivering for up to 500h of operation per year.
33 www.tind.co.th 02-559-0866-8
GENERATOR 400 KW
DIESEL ENGINE
Engine Model
BASIC TECHNICAL DATA CONSUMPTION
Manufacturer PerKins Power rating(best SFC)
Number of cylinders 6 Standby power(L/h) 109
Induction system turbocharged, air -to -air 100% prime power(L/h) 99
charge 75% prime power(L/h) 73
cooling 50% prime power(L/h) 51
Bore and stroke (mm) 1 37× 1 71
Compression ratio 1 6:1
Engine weight, dry(kg) 1 633 COOLING SYSTEM
Total coolant capacity (L) 8.0 5
TECHNICAL DATA Maximum top tank temperature ( ํC) 107
Thermostat operating range( ํC ) 88-98
Engine speed(rpm) 1500
Gross engine Standby power (kW) 451
Prime power(kW) 412
Combustion air flow(m 3/min) 33.0 ELECTRIC SYSTEM
Exhaust gas flow (max)(m 3/min) 85.0 Alternator type 22SI 24 V/70
Exhaust gas temperature outlet(max) N/A Startermotor type 42MT 24V/7.5KW
EXHAUST SYSTEM
NOTE:
Exhaust back pressure for total system (kpa) 6.8 All data is based on:
1. Engine operating with fuel system, water pump, lubr icating
oil pump,air cleaner and exhaust silencer; not included are
battery charging alternator, fan, and optional driven
components.
LUBRICATION SYSTEM 2.Engine operating with fuel corresponding to grade No. 2
per ASTM D975.
Total lubrication system capacity (dry engine) (L) 62.0 3. ISO 3046, Part 1, Standard Reference Conditions of:
Minimum oil capacity in sump 53.0 L Barometric Pressure : 100 kPa (29.53 in Hg)
Air Temperature : 25 ํC (77 ํF )
Maximum oil capacity in sump 45.0L Altitude : 110 m (361 ft)
Relative Humidity : 30%
Air Intake Restriction : 254 mm H2O (10 in H 2O)
Exhaust Restriction : 51 mm Hg (2 in Hg)
FUEL SYSTEM N/A: Not Available
TBD: To Be Determined
Injection system MEUI CP: Continuous power
Maximum static pressure head 4m FSP: Fuel stop power
Governor type Electronic
Altitude: Derate 2.0% per 300m(984 ft.) elevation above 1000m(3279 ft.) up to a maximum elevation of 2450m(8000 ft.).
More than 2450m(8000ft), please contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 11 ํC (20 ํF) temperature above 40 ํC (104 ํF ).
www.tind.co.th 02-559-0866-8 34
GENERATOR 400 KW
ALTERNATOR
Alternators meet the requirement of BS EN 60034
and the relevant section of other international
Alternator Stamford( HCI544D) standards such as BS5000, VDE 0530, NEMA MG1 -32,
Frequency and Speed 50Hz/1500rpm IEC34, CSAC22.2-100, As1359, and other standards
Voltage (V) 400 and certifications can be considered on request.
Prime capacity(kVA) 550
The 2/3 pitch design avoids excessive neutral
Prime power(kW) 440 currents.
Power efficiency(%) 94.3 With the 2/3 pitch and carefully selected pole and
tooth designs, ensures very low waveform distortion.
Voltage regulation ±1.0%
Rated power factor 0.8 Brushless alternator with brushless pilot exciter for
excellent load response.
winding type P2/3
Overspeed(rpm) 2250 The insulation system is class H, easy parallelling
Sustained short circuit 300%(3IN):20S with mains or other generators, standard 2/3 pitch
stator windings avoid excessive neutral currents.
Protection class IP23
Backed by worldwide service network .
NOTE: This drawing is provided for reference only and should not be used for
planning installation. Contact your local distributor for more detailed information.
35 www.tind.co.th 02-559-0866-8
GENERATOR 400 KW
CONTROL SYSTEM
Controlled by Model DSE7320
Control System:
www.tind.co.th 02-559-0866-8 36
MEMO
www.tind.co.th 02-559-0866-8
MEMO
www.tind.co.th 02-559-0866-8
Email: tind@tind.co.th Tel: +(66)2-559-0866-8
Address : 390 Soi Ladphrao 94 (Panjamitr) Ladphrao Rd. Plap - Pla, Wangthonglang, Bangkok 10310 Thailand