The Basic Principles Governing The National Plumbing Code
The Basic Principles Governing The National Plumbing Code
Fire Protection
5. FITTINGS ABOVE 50MM DIA SHALL BE FLANGE WEIDED TYPE FITTINGS BELOW
SHALL BE THREADED
7. FIRE HOSE CABINETS AND ACCESSORIES SHALL BE U.I., LISTED AND F.M.,
APPROVED
GENERAL NOTES:
SEPTIC TANK
4.1.1 Design Capacity — The septic tank capacity may be determined from the quantities
of sewage flow contained in Table I Chapter XVII of the Code on Sanitation of the Philippines
(see Annex), based on adequate detention time interval resulting in efficient sedimentation.
Daily flow from metered water consumption may be used to estimate flow when available. For
buildings with occupants, the number of persons to be served shall be computed based on the
number of rooms and considering each room as occupied by two persons or on the basis of the
actual number of persons served by the tank, whichever is the greater.
a. The septic tank may have various shapes provided the capacity, inlet, outlet and depth
requirements are met. Generally, the septic tank is rectangular in shape. If 2 or more
compartments are used, the first compartment shall have the capacity from one half to two
thirds of the total volume of the tank.
b. The septic tank shall have a liquid drawing depth not less than 1.20 meters {4 feet)
c. The vertical distance from the liquid level to the inside top of the tank shall be at least 20 cm.
(8 in.).
4.1.4 Inspection Manholes — The septic tank shall be provided with an inspection manhole
0.36 m2 (4 ft2) in minimum area or by an equivalent removable cover slab to provide access to
the inlet and outlet devices and to the compartment of the tank for inspection and cleaning. One
access manhole shall be located over each compartment. Septic tanks installed under concrete
or block top paving shall have the required manholes accessible by extending the manhole
openings to grade.
a. Plans and specifications for all septic tanks shall be submitted to the local health authority for
approval. Such plans and specifications shall show all dimensions, reinforcement, structural
calculations and such other pertinent data as may be required. Independent laboratory tests and
calibrations shall be provided on pre-fabricated septic tanks as may be required by the local
health authority.
b. Septic tanks shall be constructed of sound durable materials, not subject to excessive
corrosion or decay and shall be watertight. Each such tank shall be structurally designed to
withstand all anticipated earth or other loads and shall be installed level on a solid bed.
Structural and hydraulic design shall be in accordance with good engineering practice.
c. Approved pre-fabricated septic tanks may be used. After installation, the tank shall be filled
with sufficient amount of water to prevent floating.
d. Roof drains, foundation drains, area drains or cistern overflows shall not be made to enter the
septic tank or any part of the treatment system.
4.1.6. Location
a. The septic tank shall be located not less than 25 meters from any well, spring, cistern, or
other sources of drinking water supply; not less than 1.5 m.(5 ft.) from any water service line;
and not less than 3.0 m. (10 ft.) away from water main.
b. Septic tanks shall be located such that desludging equipment can have access to the
opening manholes conveniently is within 7.50 cm (3 inches) of the bottom of the outlet device or
the sludge and scum has reduced the liquid capacity by 50%.
Most fire sprinklers are available in two primary sizes: 1/2″ (12.7 mm) and 3/4″ (19.3 mm). A
1/2″ model is the most common size for office buildings, hotels, and schools. 3/4″ sprinklers, on
the other hand, are used in higher-challenge fire environments where larger quantities of water
are necessary.