Professional Documents
Culture Documents
TA1664-5213-5016 Mass & Heat Balance Utilities
TA1664-5213-5016 Mass & Heat Balance Utilities
: TA1664
Revision :0
Project Name : EcoOils SBE oil extraction and recovery plant Surabaya
Plant : Surabaya
Unit :
Stream nr. 1 2 3 4 5 6 7 8 9 10 11 12 13
Note 2 To Administration
Description RO from Estate 30P1A/B Suction Line 30P2A/B Suction Line To WTP System To Domestic User RO Mainline To Hot well To Clean CT To Dirty CT To FFA Plant To Extraction Plant To Softener Tank
Building
OPERATION Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors
COMPONENT RO Water RO Water RO Water RO Water RO Water RO Water RO Water RO Water RO Water RO Water RO Water RO Water RO Water
PHASE L/G/S L L L L L L L L L L L L L
PRESSURE (barg) ATM ATM 4 4 5 5 5 5 5 5 5 5
TEMPERATURE (°C) AMB AMB AMB AMB AMB AMB AMB AMB AMB AMB AMB AMB
MOLWEIGHT (kg/kmol) 18 18 18 18 18 18 18 18 18 18 18 18
FLOWRATE (m3/h) 25.00 15.00 25.00 15.00 14.60 0.68 0.77 4.50 2.10 2.88 2.88 0.77
MASS FLOW (kg/h) 25,000 15,000 25,000 15,000 14,600 680 770 4,500 2,100 2,880 2,875 770
DENSITY (kg/m3) 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
VISCOSITY (cP) 1 1 1 1 1 1 1 1 1 1 1 1 1
HEAT CAPACITY (kJ/kg.K) 4.178 4.178 4.178 4.178 4.178 4.178 4.178 4.178 4.178 4.178 4.178 4.178 4.178
LATENT HEAT (kJ/kg) 2257 2257 2257 2257 2257 2257 2257 2257 2257 2257 2257 2257 2257
Remarks
NOTES:
1. Flow based on consumption + 15% margin.
2. Estate to determined
DOC. No.: TA1664-5213-5016
JOB No.: TA1664
REVISION 0
MASS & HEAT BALANCE SOFTENER WATER DATE 29-8-2017
PREP'D IZH
CHK'D VV
APP'D MA
Ref. PFD/UFD: TA1644-5252-1011-R1
Consumption calculation: TA1664-5254-1000-R1
Stream nr. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Remarks
NOTES:
1. Flow based on consumption + 15% margin.
DOC. No.: TA1664-5213-5016
JOB No.: TA1664
REVISION 0
MASS & HEAT BALANCE STEAM & CONDENSATE DATE 29-8-2017
PREP'D IZH
CHK'D VV
APP'D MA
Ref. PFD/UFD: TA1644-5252-1005-R1
Consumption calculation: TA1664-5254-1000
Stream nr. 1 2 3 4 5 6 7 8
Description Steam Mainline To BFT To Extraction Plant To FFA Plant To VAC To Bleaching Oil To Tracing Header To Tank Farm
Remarks
NOTES:
1. Flow based on consumption + 15% margin.
DOC. No.: TA1664-5213-5016
JOB No.: TA1664
REVISION 0
MASS & HEAT BALANCE THERMAL HOT OIL DATE 29-8-2017
PREP'D IZH
CHK'D VV
APP'D MA
Ref. PFD/UFD: TA1644-5252-1006-R1
Consumption calculation: TA1664-5254-1000-R1
Stream nr. 1 2 5 6 7 8 9
Remarks
NOTES:
1. Flow based on consumption + 15% margin.
DOC. No.: TA1664-5213-5016
JOB No.: TA1664
REVISION 0
MASS & HEAT BALANCE HSD DATE 29-8-2017
PREP'D IZH
CHK'D VV
APP'D MA
Ref. PFD/UFD: TA1644-5252-1009-R1
Consumption calculation: TA1664-5254-1000-R1
Stream nr. 1 2 3 4 5 6 7
Unloading to Diesel
Description Mainline To Dispenser To Genset To Boiler To NEF to TFH
Tank
OPERATION Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors
COMPONENT HSD HSD HSD HSD HSD HSD HSD
PHASE L/G/S L L L L L L L
PRESSURE (barg) 3 3 3 3 3 3 3
TEMPERATURE (°C) 20 20 20 20 20 20 20
MOLWEIGHT (kg/kmol)
FLOWRATE (L/h) 5000.0 2361.5 69.0 69.0 718.8 1436.1 68.5
MASS FLOW (kg/h) 3,700 1,747 51 51 532 1,063 51
DENSITY (kg/m3) 740 740 740 740 740 740 740
VISCOSITY (cP) 0.2919 0.2919 0.2919 0.2919 0.2919 0.2919 0.2919
HEAT CAPACITY (kJ/kg.K) 2 2 2 2.34 2.34 2.34 2
LATENT HEAT (kJ/kg) 251 251 251 251 251 251 251
NOTES:
1. Flow based on consumption + 15% margin.
2. Two (2) pumps will be used for unloading operation.
3. One (1) pump will be used.
sheet 1 of 1
Stream nr. 1 2 3 4 5 6 7 8 9 10
To Maintenance
Description CA Mainline To Boiler To NEF To DOBE To WWTP To Extraction Plant To FFA Plant To VAC To Tank Farm
Workshop
OPERATION Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Indoors
COMPONENT Compressed Air Compressed Air Compressed Air Compressed Air Compressed Air Compressed Air Compressed Air Compressed Air Compressed Air Compressed Air
PHASE L/G/S G G G G G G G G G G
PRESSURE (barg) 10 10 10 10 10 10 10 10 10 10
TEMPERATURE (°C) 30 30 30 30 30 30 30 30 30 30
MOLWEIGHT (kg/kmol) 29 29 29 29 29 29 29 29 29 29
FLOWRATE (Nm3/h)) 1760.0 189.8 707.3 224.3 34.5 189.8 189.8 189.8 34.5 34.5
DENSITY, 0° C, 1 atm (kg/m3) 1.2920 1.2920 1.2920 1.2920 1.2920 1.2920 1.2920 1.2920 1.2920 1.2920
VISCOSITY (mPa.s) 1.846 1.846 0.797 0.797 0.797 0.797 0.797 0.797 0.797 0.797
HEAT CAPACITY (cP) 1.0049 1.0049 4.178 4.178 4.178 4.178 4.178 4.178 4.178 4.178
LATENT HEAT (kJ/kg) 1007 1007 1007 1007 1007 1007 1007 1007 1007 1007
Remarks
NOTES:
1. Flow based on consumption + 15% margin.
sheet 1 of 1
Stream nr. 1 2 5 6 7 8 9 10 11 12 13 14 15
NOTES:
1. Flowrate calculated based on fluid velocity = 10m/s in the NB40 pipe. The consumption will be 18 nitrogen bottle (50 kg each) per week.
sheet 1 of 1
Stream nr. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Remarks
NOTES:
1. Flow based on consumption + 15% margin.
DOC. No.: TA1664-5213-5016
JOB No.: TA1664
REVISION 0
MASS & HEAT BALANCE CHILLED WATER DATE 29-8-2017
PREP'D IZH
CHK'D VV
APP'D MA
Ref. PFD/UFD: TA1644-5252-1001-R1
Consumption calculation: TA1664-5254-1000-R1
Stream nr. 1 2 3 4 5 6 7 8 9 10 11 12
Description From Hot Well To Chiller To Cold Well To Extraxtion Plant From Extraction Plant
OPERATION Outdoors Outdoors Outdoors Outdoors Outdoors
COMPONENT Chilled water Chilled water Clean cooling water Clean cooling water Clean cooling water
PHASE L/G/S L L L L L
PRESSURE (barg) 0 5 5 5 5
TEMPERATURE (°C) 11.5 11.5 11.5 11.5 11.5
MOLWEIGHT (kg/kmol) 18 18 18 18 18
ACTUAL FLOW (m3/h) 79 79 79 79 79
MASS FLOW (kg/h) 79,000 79,000 79,000 79,000 79,000
DENSITY (kg/m3) 1000 1000 1000 1000 1000
VISCOSITY (mPa.s) 1 1 1 1 1
HEAT CAPACITY (kJ/kg.K) 4.18 4.18 4.18 4.18 4.18
LATENT HEAT (kJ/kg) 2257 2257 2257 2257 2257
NOTES:
1. Flow based on consumption + 15% margin.
DOC. No.: TA1664-5213-5016
JOB No.: TA1664
REVISION 0
MASS & HEAT BALANCE CLEAN COOLING WATER DATE 29-8-2017
PREP'D IZH
CHK'D VV
APP'D MA
Ref. PFD/UFD: TA1644-5252-1002-R1
Consumption calculation TA1664-5254-1000-R1
Stream nr. 1 2 3 4 5 6 7 8 9 10 11 12
OPERATION Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors
COMPONENT Clean cooling water Clean cooling water Clean cooling water Clean cooling water Clean cooling water Clean cooling water Clean cooling water Clean cooling water Clean cooling water Clean cooling water Clean cooling water Clean cooling water
PHASE L/G/S L L L L L L L L L L L L
PRESSURE (barg) 0 5 5 5 5 5 5 5 5 5 5 5
TEMPERATURE (°C) 30 30 30 30 30 30 30 30 30 35 35 35
MOLWEIGHT (kg/kmol) 18 18 18 18 18 18 18 18 18 18 18 18
ACTUAL FLOW (m3/h) 665 88 576.6 456.6 120 402.6 54 6 396.6 120 54 6
MASS FLOW (kg/h) 665,000 88,400 576,600 456,600 120,000 402,600 54,000 6,000 396,600 120,000 54,000 6,000
DENSITY (kg/m3) 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
VISCOSITY (mPa.s) 1 1 1 1 1 1 1 1 1 1 1 1
HEAT CAPACITY (kJ/kg.K) 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18
LATENT HEAT (kJ/kg) 2257 2257 2257 2257 2257 2257 2257 2257 2257 2257 2257 2257
LINE SIZE (NPS) 400 100 350 350 200 250 150 65 350 200 150 65
INSULATED YES YES YES YES YES YES YES YES YES YES YES YES
TRACED NO NO NO NO NO NO NO NO NO NO NO NO
Remarks --- --- --- --- --- --- --- --- --- --- --- ---
PFD/UFD NO. TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002 TA1664-5252-1002
Stream nr. 13 14 15 16 17 18 19 20 21 22 23 24
From Extraction Plant + From Extraction Plant +
Description Main Return Line
RVDF RVDF, NEF
OPERATION Outdoors Outdoors Outdoors
COMPONENT Clean cooling water Clean cooling water Clean cooling water
PHASE L/G/S L L L
PRESSURE (barg) 5 5 5
TEMPERATURE (°C) 35 35 35
MOLWEIGHT (kg/kmol) 18 18 18
ACTUAL FLOW (m3/h) 396.6 402.6 456.6
MASS FLOW (kg/h) 396,600 402,600 456,600
DENSITY (kg/m3) 1000 1000 1000
VISCOSITY (mPa.s) 1 1 1
HEAT CAPACITY (kJ/kg.K) 4.18 4.18 4.18
LATENT HEAT (kJ/kg) 2257 2257 2257
NOTES:
1. Flow based on consumption + 15% margin.
DOC. No.: TA1664-5213-5016
JOB No.: TA1664
REVISION 0
MASS & HEAT BALANCE DIRTY COOLING WATER DATE 29-8-2017
PREP'D IZH
CHK'D VV
APP'D MA
Ref. PFD/UFD: TA1644-5252-1003-R1
Consumption calculation: TA1664-5254-1000-R1
Stream nr. 1 2 3 4 5 6 7 8 9 10 11 12
Over Pressure To
Description From Cooling Tower To FFA From FFA To Cooling Tower To Cooling Tower
Cooling Tower
OPERATION Outdoors Outdoors Outdoors Outdoors Outdoors Outdoors
COMPONENT Dirty cooling water Dirty cooling water Dirty cooling water Dirty cooling water Dirty cooling water Dirty cooling water
PHASE L/G/S L L L L L L
PRESSURE (barg) 0 5 5 5 5 5
TEMPERATURE (°C) 30 30 30 42 42 42
MOLWEIGHT (kg/kmol) 18 18 18 18 18 18
ACTUAL FLOW (m3/h) 115 15 100 100 100 100
MASS FLOW (kg/h) 115,000 15,000 100,000 100,000 100,000 100,000
DENSITY (kg/m3) 1000 1000 1000 1000 1000 1000
VISCOSITY (mPa.s) 1 1 1 1 1 1
HEAT CAPACITY (kJ/kg.K) 4.18 4.18 4.18 4.18 4.18 4.18
LATENT HEAT (kJ/kg) 2257 2257 2257 2257 2257 2257
NOTES:
1. Flow based on consumption + 15% margin.