Professional Documents
Culture Documents
Rumah Lampung - vc0 Report
Rumah Lampung - vc0 Report
PVsyst TRIAL
PVsyst - Simulation report
Standalone system
PVsyst TRIAL
Tamanbogo - Indonesia
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: New Project2
Variant: New simulation variant
PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50
PVsyst TRIAL
with v7.4.2
Project summary
Geographical Site Situation Project settings
Tamanbogo Latitude -5.01 °S Albedo 0.20
Indonesia Longitude 105.50 °E
Altitude 31 m
Time zone UTC+7
Meteo data
Tamanbogo
Meteonorm 8.1 (1996-2015), Sat=100% - Synthetic
System summary
PVsyst TRIAL
Standalone system Standalone system with batteries
System information
PV Array Battery pack
Nb. of modules 8 units Technology Lithium-ion, LFP
Pnom total 1200 Wp Nb. of units 6 units
Voltage 13 V
Capacity 600 Ah
Results summary
PVsyst TRIAL
Useful energy from solar 886.58 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
794.62 kWh/year
Table of contents
Solar Fraction SF
41.04 %
100.00 %
2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7
PVsyst TRIAL
PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 2/7
Project: New Project2
Variant: New simulation variant
PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50
PVsyst TRIAL
with v7.4.2
General parameters
Standalone system Standalone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 7.7 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 2.4 kWh/Day
PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 150 Wp
PV Array Characteristics
Generic
Mono 150 Wp 36 cells
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Adjustable Li-Ion
Lithium-ion, LFP
6 in parallel
Number of PV modules 8 units Discharging min. SOC 10.0 %
Nominal (STC) 1200 Wp Stored energy 6.7 kWh
Modules 4 Strings x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 13 V
Pmpp 1067 Wp Nominal Capacity 600 Ah (C10)
U mpp 33 V Temperature Fixed 20 °C
I mpp 32 A
PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.
97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35
Total PV power
Nominal (STC) 1.20 kWp
Total 8 modules
Module area 8.0 m²
Cell area 6.8 m²
Array losses
PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)
-0.8 %
DC wiring losses
Global array res.
Loss Fraction
0.5 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction
0.2 %
PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 3/7
Project: New Project2
Variant: New simulation variant
PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50
PVsyst TRIAL
with v7.4.2
PVsyst TRIAL
Total daily energy 2429
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 4/7
Project: New Project2
Variant: New simulation variant
PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50
PVsyst TRIAL
with v7.4.2
Main results
System Production
Useful energy from solar 886.58 kWh/year Perf. Ratio PR 41.04 %
Available solar energy 1714.25 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 794.62 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 93.0 %
Missing Energy 0.00 kWh/year Static SOW 90.0 %
Battery lifetime 10.0 years
PVsyst TRIAL
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
November 146.7 137.6 136.0 60.50 0.000 72.87 72.87 1.000
December 155.4 142.6 139.2 61.70 0.000 75.30 75.30 1.000
Year 1794.0 1750.1 1714.3 794.62 0.000 886.58 886.58 1.000
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 5/7
Project: New Project2
Variant: New simulation variant
PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50
PVsyst TRIAL
with v7.4.2
Loss diagram
1794 kWh/m² Global horizontal irradiation
+0.3% Global incident in coll. plane
PVsyst TRIAL
-0.69% PV loss due to irradiance level
PVsyst TRIAL
963 kWh Effective energy at the output of the array
887 kWh
-0.02% Battery Self-discharge Current
Energy supplied to the user
PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 6/7
Project: New Project2
Variant: New simulation variant
PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50
PVsyst TRIAL
with v7.4.2
Predef. graphs
Daily Input/Output diagram
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 7/7