Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Version 7.4.

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: New Project2


Variant: New simulation variant
Standalone system with batteries
System power: 1200 Wp

PVsyst TRIAL
Tamanbogo - Indonesia

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: New Project2
Variant: New simulation variant

PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50

PVsyst TRIAL
with v7.4.2

Project summary
Geographical Site Situation Project settings
Tamanbogo Latitude -5.01 °S Albedo 0.20
Indonesia Longitude 105.50 °E
Altitude 31 m
Time zone UTC+7

Meteo data
Tamanbogo
Meteonorm 8.1 (1996-2015), Sat=100% - Synthetic

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 7.7 / 0 ° Constant over the year
Average 2.4 kWh/Day

System information
PV Array Battery pack
Nb. of modules 8 units Technology Lithium-ion, LFP
Pnom total 1200 Wp Nb. of units 6 units
Voltage 13 V
Capacity 600 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 886.58 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
794.62 kWh/year

Project and results summary


Specific production 739 kWh/kWp/year Perf. Ratio PR
Available solar energy 1714.25 kWh/year

Table of contents
Solar Fraction SF
41.04 %
100.00 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 2/7
Project: New Project2
Variant: New simulation variant

PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50

PVsyst TRIAL
with v7.4.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 7.7 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 2.4 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 150 Wp
PV Array Characteristics

Generic
Mono 150 Wp 36 cells
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Adjustable Li-Ion
Lithium-ion, LFP
6 in parallel
Number of PV modules 8 units Discharging min. SOC 10.0 %
Nominal (STC) 1200 Wp Stored energy 6.7 kWh
Modules 4 Strings x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 13 V
Pmpp 1067 Wp Nominal Capacity 600 Ah (C10)
U mpp 33 V Temperature Fixed 20 °C
I mpp 32 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 1.20 kWp
Total 8 modules
Module area 8.0 m²
Cell area 6.8 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.8 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
17 mΩ
1.5 % at STC

0.5 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.9 % at STC

0.2 %

IAM loss factor


ASHRAE Param.: IAM = 1 - bo (1/cosi -1)
bo Param. 0.05

PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 3/7
Project: New Project2
Variant: New simulation variant

PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50

PVsyst TRIAL
with v7.4.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 2.4 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
Rice Cooker 1 450/lamp 0.5 225
TV 1 60/app 6.0 360
Kipas 1 50/app 4.0 200
Pompa Air 1 150 tot 2.0 300
Kulkas 1 110 tot 12.0 1320
Stand-by consumers 24.0 24

PVsyst TRIAL
Total daily energy 2429

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 4/7
Project: New Project2
Variant: New simulation variant

PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50

PVsyst TRIAL
with v7.4.2

Main results
System Production
Useful energy from solar 886.58 kWh/year Perf. Ratio PR 41.04 %
Available solar energy 1714.25 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 794.62 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 93.0 %
Missing Energy 0.00 kWh/year Static SOW 90.0 %
Battery lifetime 10.0 years

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL

PVsyst TRIAL
Balances and main results

GlobHor GlobEff E_Avail EUnused E_Miss E_User E_Load SolFrac


kWh/m² kWh/m² kWh kWh kWh kWh kWh ratio
January 158.4 147.0 143.9 64.23 0.000 75.30 75.30 1.000
February 145.7 138.5 135.3 64.67 0.000 68.01 68.01 1.000
March 164.1 159.7 155.2 77.39 0.000 75.30 75.30 1.000
April 145.4 145.2 142.0 66.31 0.000 72.87 72.87 1.000
May 140.5 143.0 140.3 62.34 0.000 75.30 75.30 1.000
June 132.5 135.9 134.4 59.01 0.000 72.87 72.87 1.000
July 145.0 148.9 146.7 68.67 0.000 75.30 75.30 1.000
August 144.9 145.7 142.7 64.80 0.000 75.30 75.30 1.000
September 147.4 144.7 141.1 65.53 0.000 72.87 72.87 1.000
October 168.1 161.4 157.4 79.47 0.000 75.30 75.30 1.000

PVsyst TRIAL
November 146.7 137.6 136.0 60.50 0.000 72.87 72.87 1.000
December 155.4 142.6 139.2 61.70 0.000 75.30 75.30 1.000
Year 1794.0 1750.1 1714.3 794.62 0.000 886.58 886.58 1.000

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 5/7
Project: New Project2
Variant: New simulation variant

PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50

PVsyst TRIAL
with v7.4.2

Loss diagram
1794 kWh/m² Global horizontal irradiation
+0.3% Global incident in coll. plane

-2.78% IAM factor on global

1750 kWh/m² * 8 m² coll. Effective irradiation on collectors

efficiency at STC = 15.09% PV conversion

2116 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-0.69% PV loss due to irradiance level

-13.67% PV loss due to temperature

+0.75% Module quality loss

-0.65% Mismatch loss, modules and strings

-3.24% Ohmic wiring loss

-45.22% Unused energy (battery full)

PVsyst TRIAL
963 kWh Effective energy at the output of the array

-4.44% Converter Loss during operation (efficiency)


-0.03% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
920 kWh Converter losses (effic, overload)
Missing
Direct use Stored Battery Storage
energy 27.7% 72.3%
+0.15% Battery Stored Energy balance
0.00%
0.0 kWh
-3.24% Battery efficiency loss
-2.59% Charge/Disch. Current Efficiency Loss

PVsyst TRIAL 887 kWh

887 kWh
-0.02% Battery Self-discharge Current
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 6/7
Project: New Project2
Variant: New simulation variant

PVsyst V7.4.2
VC0, Simulation date:
09/25/23 03:50

PVsyst TRIAL
with v7.4.2

Predef. graphs
Daily Input/Output diagram

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
09/25/23 PVsyst Evaluation mode Page 7/7

You might also like