COMTECO

APS Configuration
7705 SAR18

Martín Ljubicic
Integration Engineer

Nokia Networks proprietary and confidential. Copyright © 2017. All rights reserved.
Contents
1 Introduction.........................................................................................................................................3
1.1 Purpose........................................................................................................................................3
1.2 Document History........................................................................................................................3
1.3 Related Information.....................................................................................................................3
1.4 Technical Support........................................................................................................................3
1.5 Disclaimer....................................................................................................................................3
2 Preliminary Information......................................................................................................................4
2.1 Affected Network Elements or Sites............................................................................................4
2.2 Logins...........................................................................................................................................4
2.3 Dependencies..............................................................................................................................4
3 Configuration.......................................................................................................................................4
3.1 APS...............................................................................................................................................4
3.2 Fabric profile................................................................................................................................5

Nokia Networks proprietary and confidential. Copyright © 2017. All rights reserved.
1 Introduction

1.1 Purpose
This document describes the APS mechanism for redundancy on a single 7705 SAR 18.

1.2 Document History

The table below shows the revision history of this document.

Date Issue Description Author

07/11/2017 1.0 Document creation Martin Ljubicic

1.3 Related Information

The following list provides the relevant documentation for 7705 SAR 18. Please refer to these documents for 7705
SAR information regarding Planning, Features, Applications, Hardware, Software, and OA&M.

 7705 SAR Integration MOP Template


 7705 SAR Software Upgrade MOP Template
 7705 SAR Acceptance Test Plan

1.4 Technical Support

For technical support, contact your local Nokia customer support team. See the Nokia Support web site
http://Nokia.com/support/ for contact information.

1.5 Disclaimer

NOKIA is not responsible for any outages and/or delay caused by Non-NOKIA hardware during the execution of the
SAR 18 Acceptance Test Plan.

Nokia Networks proprietary and confidential. Copyright © 2017. All rights reserved.
2 Preliminary Information

2.1 Affected Network Elements or Sites

The list below identifies the equipment that is modified during execution of this Acceptance Test Plan document.
Prior to implementation, verify and confirm that the information is correct.

 SAR 18 Centro
 SAR 18 Hipodromo

2.2 Logins

The login information required during execution of this Acceptance Test Plan document are defaults Passwords
and passphrases are not included for security reasons and are to be provided to COMTECO.

2.3 Dependencies

The following list provides the dependencies and customer deliverables for the successful implementation of this
Acceptance Test Plan. If these criteria are not met, this Acceptance Test Plan will not be executed.

 The 7705 SAR must be physically installed and powered prior to the arrival of the integration team.
 All cabling to the 7705 SAR has been run.

3 Configuration

3.1 APS

Automatic Protection Switching (APS) is a means to provide redundancy on SONET equipment to guard
against linear unidirectional or bidirectional failures. The network elements (NEs) in a SONET/SDH
network constantly monitor the health of the network. When a failure is detected, the network
proceeds through a coordinated predefined sequence of steps to transfer (or switchover) live traffic to
the backup facility (called protection facility.) This is done very quickly to minimize lost traffic. Traffic
remains on the protection facility until the primary facility (called working facility) fault is cleared, at
which time the traffic may optionally be reverted to the working facility.

/configure port 1/11/[1..2] sonet-sdh framing sdh


/configure port 1/11/[1..2] no shutdown
/configure port 1/12/[1..2] sonet-sdh framing sdh
/configure port 1/12/[1..2] no shutdown
/configure port aps-1
aps

Nokia Networks proprietary and confidential. Copyright © 2017. All rights reserved.
working-circuit 1/11/1
protect-circuit 1/12/1
exit
sonet-sdh
path sts3
no shutdown
exit
group tug3-1 payload vt2
group tug3-2 payload vt2
group tug3-3 payload vt2
path vt2-1.1.1
no shutdown
exit
path vt2-1.1.2
no shutdown
exit
{…}
/configure port aps-2
aps
working-circuit 1/11/2
protect-circuit 1/12/2
exit
sonet-sdh
path sts3
no shutdown
exit
group tug3-1 payload vt2
group tug3-2 payload vt2
group tug3-3 payload vt2
path vt2-1.1.1
no shutdown
exit
path vt2-1.1.2
no shutdown
exit

3.2 Fabric profile

The SAR18 default configuration is set to 200Mbps of traffic between the Cards and the fabric.
Is necessary configure a fabric profile in 2,5 Gbps.

/configure qos
fabric-profile 25 aggregate-mode create
description "Fabric_2.5G"
aggregate-rate 2500000 unshaped-sap-cir 0
exit

Nokia Networks proprietary and confidential. Copyright © 2017. All rights reserved.
/configure card 1
mda 11
mda-type a2-choc3
network
ingress
fabric-policy 25
exit
exit
access
ingress
fabric-policy 25
exit
exit
no shutdown
exit
mda 12
mda-type a2-choc3
network
ingress
fabric-policy 25
exit
exit
access
ingress
fabric-policy 25
exit
exit
no shutdown
exit

END DOCUMENT

Nokia Networks proprietary and confidential. Copyright © 2017. All rights reserved.