Professional Documents
Culture Documents
Drafts - Drafts - Concrete - 24 Anchors - North - c25-30
Drafts - Drafts - Concrete - 24 Anchors - North - c25-30
88
www.hilti.co.uk
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
Specifier's comments:
1 Anchor Design
1.1 Input data
Baseplate
CBFEM
: lx x ly x t = 920.0 mm x 950.0 mm x 70.0 mm;
CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gM,s
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
N
NEd £ NRd,p = Rk,p EN 1992-4, Table 7.1
gM,p
0 Ap,N
NRk,p = NRk,p · 0
· y g,Np · y s,Np · y re,N · y ec1,Np · y ec2,Np EN 1992-4, Eq. (7.13)
Ap,N
0
NRk,p = y sus · t Rk · p · d · hef EN 1992-4, Eq. (7.14)
y sus =1 EN 1992-4, Eq. (7.14a)
Rk,c
³ 1.00 EN 1992-4, Eq. (7.18)
k3
t Rk,c = · √hef · fck EN 1992-4, Eq. (7.19)
p·d
c
y s,Np = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.20)
ccr,Np £
1
y ec1,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec1,N £
1+ (
scr,Np )
1
y ec2,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec2,N £
1+ (
scr,Np )
2 0 2 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,20 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm] fc,cyl [N/mm ]
2,529,868 863,298 18.00 929.1 464.6 300.0 25.00
0
yc t Rk,cr [N/mm ]
2
k3 t Rk,c [N/mm ]
2
y g,Np y g,Np
1.023 9.20 7.700 10.01 1.354 1.186
Group anchor ID
5, 6, 10, 11, 14-16, 20-23, 26, 27, 30, 31, 33
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
3,775,200 3,240,000 900.0 1,800.0 25.00
Group anchor ID
5, 6, 10, 11, 14-16, 20-23, 26, 27, 30, 31, 33
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)
0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
168.300 1.000 168.300 1.250 134.640 16.012
V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · min {NRk,c; NRk,p} EN 1992-4, Eq. (7.39c)
0 A
NRk,c = NRk,c · 0c,N · y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
3,775,200 3,240,000 900.0 1,800.0 2.000 25.00
Group anchor ID
1-34
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gM,c
0 Ac,V
VRk,c = kT · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2
= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
1.5 Combined tension and shear loads (EN 1992-4, Section 7.2.3)
Steel failure
a a
bN + bV £ 1.0
Concrete failure
1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid baseplates as per current regulations (ETAG 001/Annex C, EOTA TR029,
etc.). This means load re-distribution on the anchors due to elastic deformations of the baseplate are not considered - the baseplate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the
minimum required baseplate thickness with CBFEM to limit the stress of the baseplate based on the assumptions explained above. The
proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• Attention! In case of compressive anchor forces a buckling check as well as the proof of the local load transfer into and within the base
material (incl. punching) has to be done separately.
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure
• Design is only valid if hole is filled to remove clearance, clearance as per EN 1992-4 Table 6.1
• Load transfer from supplementary reinforcement to the structural member shall be verified by the responsible structural engineer.
• With supplementary reinforcement and post-installed anchors, please ensure that in the jobsite the rebars are not drilled through.
• The anchor design methods in PROFIS Engineering require rigid baseplates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the baseplate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the baseplate is considered close to rigid by engineering judgment."
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
Hilti HAS-U threaded rod with HIT-HY 200 injection mortar with 600 mm embedment h_ef, M30, Steel galvanized, SAFEset - automatic
cleaning installation per ETA 11/0493, with annular gaps filled with Hilti Filling Set or any suitable gap solutions
y
460.0 460.0
55.0
23 24 25 26 27 28
140.0
17 18 19 20 21 22
475.0
140.0
12 13 29 30 15 16
140.0
7 8 10 11
x
140.0
3 4 5 6
140.0
475.0
1 9 14 2
140.0
31 32 33 34
55.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
2 Baseplate design
2.2 Summary
Description Profile Baseplate Welds [%] Concrete [%]
sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] Hole bearing
[%]
1 Combination 1 84.32 0.00 59.26 0.00 2 60 9
2.3 Baseplate plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid baseplate (CBFEM) Component-based Finite Element Method
(CBFEM) baseplate
Anchor 1 -0.005 kN -0.003 kN
Anchor 2 27.627 kN 0.000 kN
Anchor 3 -0.005 kN -0.006 kN
Anchor 4 -0.004 kN -0.009 kN
Anchor 5 20.579 kN 59.892 kN
Anchor 6 28.376 kN 21.726 kN
Anchor 7 -0.005 kN -0.006 kN
Anchor 8 -0.004 kN -0.011 kN
Anchor 9 -0.004 kN -0.005 kN
Anchor 10 21.328 kN 70.384 kN
Anchor 11 29.125 kN 25.740 kN
Anchor 12 -0.005 kN -0.005 kN
Anchor 13 -0.004 kN -0.009 kN
Anchor 14 19.830 kN 36.544 kN
Anchor 15 22.076 kN 60.489 kN
Anchor 16 29.873 kN 22.492 kN
Anchor 17 -0.005 kN -0.003 kN
Anchor 18 -0.003 kN -0.005 kN
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
12
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
Anchor tension forces Equivalent rigid baseplate (CBFEM) Component-based Finite Element Method
(CBFEM) baseplate
Anchor 19 -0.002 kN -0.003 kN
Anchor 20 0.000 kN 29.966 kN
Anchor 21 22.823 kN 34.666 kN
Anchor 22 30.620 kN 3.527 kN
Anchor 23 -0.005 kN 2.998 kN
Anchor 24 -0.003 kN -0.001 kN
Anchor 25 -0.002 kN -0.001 kN
Anchor 26 0.691 kN 8.673 kN
Anchor 27 23.571 kN 3.924 kN
Anchor 28 31.367 kN -0.002 kN
Anchor 29 -0.002 kN -0.006 kN
Anchor 30 0.000 kN 50.130 kN
Anchor 31 -0.005 kN 1.240 kN
Anchor 32 -0.004 kN -0.001 kN
Anchor 33 19.080 kN 16.252 kN
Anchor 34 26.877 kN -0.002 kN
User accepted to consider the selected baseplate as rigid by his/her engineering judgement. This means the anchor design guidelines can be
applied.
2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for
critical cross sections, which should be performed outside of PROFIS Engineering.
Results
Part Load Material sEd [N/mm²] ePl [%] fy [N/mm²] gM0 fy/gM0 elim [%] Status
combination [N/mm²]
Plate Combination S 355 59.26 0.00 335.00 1.00 335.00 5.00 OK
1
Profile Combination S 355 84.32 0.00 335.00 1.00 335.00 5.00 OK
1
Profile Combination S 355 73.20 0.00 335.00 1.00 335.00 5.00 OK
1
Profile Combination S 355 60.29 0.00 335.00 1.00 335.00 5.00 OK
1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
13
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
335.00 N/mm²
0.00 N/mm²
2.4.1.2 Plastic strain
Results below are displayed for the decisive load combination: 1 - Combination 1
5.00%
0.00%
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
14
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 15
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
Equations
k1 ab fu d t
Fb,Rd =
gM2
VEd
Utilisation =
Fb,Rd
Variables
k1 ab fu [N/mm²] d [mm] t [mm] gM2
Anchor 1 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 2 2.50 0.45 470.00 30.0 70.0 1.25
Anchor 3 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 4 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 5 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 6 2.50 0.45 470.00 30.0 70.0 1.25
Anchor 7 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 8 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 9 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 10 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 11 2.50 0.46 470.00 30.0 70.0 1.25
Anchor 12 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 13 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 14 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 15 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 16 2.50 0.46 470.00 30.0 70.0 1.25
Anchor 17 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 18 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 19 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 20 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 21 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 22 2.50 0.46 470.00 30.0 70.0 1.25
Anchor 23 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 24 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 25 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 26 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 27 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 28 2.50 0.46 470.00 30.0 70.0 1.25
Anchor 29 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 30 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 31 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 32 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 33 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 34 2.50 0.45 470.00 30.0 70.0 1.25
Results
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
15
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 16
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
2.5 Welds
Profiles are modelled without taking the corner radius into account. Special rules for welding (e.g. for cold-formed profiles ...) are not taken into
account by the software.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
16
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 17
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
Equations
Results
Edge sw,Ed [N/mm²] sw,Rd [N/mm²] s┴,Rd [N/mm²] Utilisation [%] Utilisationc [%] Status
Member 1-bfl 1 144.61 435.56 352.80 34 16 OK
Member 1-bfl 257.23 435.56 352.80 60 43 OK
Member 1-tfl 1 235.94 435.56 352.80 55 38 OK
Member 1-tfl 138.30 435.56 352.80 32 14 OK
Member 1-w 1 106.30 435.56 352.80 25 15 OK
Member 1-w 108.01 435.56 352.80 25 14 OK
2.6 Concrete
Decisive load combination: 1 - Combination 1
According to EN1992-1-1 section 6.7(4), the concrete should have sufficient reinforcement to take into account the tensile forces that develop
due to the fixture attachment. The definition of the reinforcement in the concrete is not within the scope of PROFIS Engineering.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
17
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 18
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
0.00 N/mm²
2.6.2 Verification of compression in concrete under the baseplate around the profile as per EN1992-1 section 6.7 and EN1993-1-8,
section 6.2.5
Equations
fjd
bj kj acc fck
=
gc
N
s = A
eff
Utilisation =
s
fjd
Variables
N [kN] Aeff [mm²] bj kj acc fck [N/mm²] gc
432.460 228,324 0.67 2.45 0.85 25.00 1.50
Results
s [N/mm²] fjd [N/mm²] Utilisation [%] Status
1.89 23.28 9 OK
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
18
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 19
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
2.8 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
baseplate may not behave rigidly. Please, have the results validated by a professional designer and/or structural engineer to ensure
suitability and adequacy for your specific jurisdiction and project requirements.
● The anchor is modelled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
19
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 20
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
3 Summary of results
Design of the baseplate, anchor, welds and other elements are based on CBFEM (component based finite element method) and Eurocode
regulations.
Load combination Max. utilisation Status
Anchors Combination 1 388% NOT OK
Baseplate Combination 1 18% OK
Welds Combination 1 60% OK
Concrete Combination 1 9% OK
Profile Combination 1 26% OK
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
20
Hilti PROFIS Engineering 3.0.88
www.hilti.co.uk
Company: Page: 21
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
21