Hilti PROFIS Engineering 3.0.

88

www.hilti.co.uk
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

Specifier's comments:

1 Anchor Design
1.1 Input data

Anchor type and size: HIT-HY 200-A + HAS-U 5.8 M30


Return period (service life in years): 50
Item number: not available (insert) / 2022696 HIT-HY 200-A
(mortar)
Hilti Filling Set or any suitable annular gap filling solution
Effective embedment depth: hef,act = 600.0 mm (hef,limit = - mm)
Material: 5.8
Approval No.: ETA 11/0493
Issued I Valid: 10/12/2021 | -
Proof: SOFA based on EN 1992-4, Chemical
Stand-off installation: eb = 0.0 mm (no stand-off); t = 70.0 mm

Baseplate
CBFEM
: lx x ly x t = 920.0 mm x 950.0 mm x 70.0 mm;

Profile: HD, HD 404; (L x W x T x FT) = 407.0 mm x 404.0 mm x 43.7 mm x 43.7 mm


Base material: 2
cracked concrete, C25/30, fc,cyl = 25.00 N/mm ; h = 1,500.0 mm, Temp. short/long: 0/0 °C,
User-defined partial material safety factor gc = 1.500
Installation: automatic cleaned drilled hole, Installation condition: Dry
Reinforcement: Reinforcement spacing < 150 mm (any Ø) or < 100 mm (Ø <= 10 mm)
with longitudinal edge reinforcement d >= 12.0 [mm] + close mesh (stirrups, hangers) s <= 100.0
[mm]
Reinforcement to control splitting acc. to EN 1992-4, 7.2.1.7 (2) b) 2) present

CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

1.1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Combination 1 N = 19.000; Vx = -488.500; Vy = 17.000; no no 388
Mx = 14.600; My = -212.000; Mz = 0.000;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

1.2 Load case/Resulting anchor forces 23 24 25 y 26 27 28

Anchor reactions [kN] 17 18 19 20 21 22


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y 12 13 29 30 15 16
1 -0.003 15.508 -15.481 0.917
2 0.000 15.405 -15.405 -0.088 7 8 x
10 11
3 -0.006 15.658 -15.605 1.285 Compression Tension
4 -0.009 15.917 -15.897 0.797 3 4 5 6
5 59.892 15.867 -15.866 0.040
6 21.726 15.549 -15.543 -0.448 1 9 14 2
7 -0.006 15.483 -15.356 1.979
8 -0.011 16.012 -15.940 1.525 31 32 33 34
9 -0.005 15.656 -15.643 0.646
10 70.384 15.771 -15.764 -0.474
11 25.740 15.310 -15.274 -1.041
12 -0.005 14.698 -14.457 2.652
13 -0.009 14.869 -14.706 2.197
14 36.544 15.603 -15.602 0.181
15 60.489 14.640 -14.606 -1.002
16 22.492 14.408 -14.317 -1.614
17 -0.003 13.541 -13.214 2.958
18 -0.005 13.499 -13.306 2.273
19 -0.003 13.352 -13.291 1.275
20 29.966 13.240 -13.239 -0.134
21 34.666 13.239 -13.191 -1.119
22 3.527 13.182 -13.040 -1.930
23 2.998 12.461 -12.088 3.028
24 -0.001 12.331 -12.128 2.232
25 -0.001 12.155 -12.094 1.217
26 8.673 12.052 -12.051 -0.131
27 3.924 12.044 -11.989 -1.157
28 -0.002 12.040 -11.871 -2.009
29 -0.006 15.000 -14.944 1.298
30 50.130 14.942 -14.942 -0.073
31 1.240 15.412 -15.391 0.818
32 -0.001 15.506 -15.494 0.623
33 16.252 15.472 -15.470 0.243
34 -0.002 15.295 -15.295 0.036

resulting tension force in (x/y)=(256.8/34.0): 448.565 [kN]


resulting compression force in (x/y)=(-235.0/15.1): 432.460 [kN]

Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

1.3 Tension load EN 1992-4, Section 7.2.1

Load [kN] Capacity [kN] Utilization bN [%] Status


Steel failure* 70.384 187.000 38 OK
Combined pullout-concrete cone failure** 448.642 876.249 52 OK
Concrete Breakout failure** 448.642 315.059 143 not recommended
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

1.3.1 Steel failure

N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gM,s

NRk,s [kN] gM,s NRd,s [kN] NEd [kN]


280.500 1.500 187.000 70.384

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

1.3.2 Combined pullout-concrete cone failure

N
NEd £ NRd,p = Rk,p EN 1992-4, Table 7.1
gM,p
0 Ap,N
NRk,p = NRk,p · 0
· y g,Np · y s,Np · y re,N · y ec1,Np · y ec2,Np EN 1992-4, Eq. (7.13)
Ap,N
0
NRk,p = y sus · t Rk · p · d · hef EN 1992-4, Eq. (7.14)
y sus =1 EN 1992-4, Eq. (7.14a)

scr,Np = 7.3 · d · √y sus · t Rk £ 3 · hef EN 1992-4, Eq. (7.15)


0,5
y g,Np
0
= y g,Np -
s
s
( ) · (y g,Np - 1) ³ 1.00
cr,Np
0
EN 1992-4, Eq. (7.17)
1,5
0
y g,Np = √n - (√n - 1) · (tt )
Rk

Rk,c
³ 1.00 EN 1992-4, Eq. (7.18)
k3
t Rk,c = · √hef · fck EN 1992-4, Eq. (7.19)
p·d
c
y s,Np = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.20)
ccr,Np £
1
y ec1,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec1,N £
1+ (
scr,Np )
1
y ec2,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec2,N £
1+ (
scr,Np )
2 0 2 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,20 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm] fc,cyl [N/mm ]
2,529,868 863,298 18.00 929.1 464.6 300.0 25.00
0
yc t Rk,cr [N/mm ]
2
k3 t Rk,c [N/mm ]
2
y g,Np y g,Np
1.023 9.20 7.700 10.01 1.354 1.186

ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np


65.8 0.876 36.0 0.928 0.894 1.000
0
y sus asus y sus
0.740 0.000 1.000
0
NRk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NEd [kN]
520.422 1,314.373 1.500 876.249 448.642

Group anchor ID
5, 6, 10, 11, 14-16, 20-23, 26, 27, 30, 31, 33

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

1.3.3 Concrete Breakout failure

N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)

2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
3,775,200 3,240,000 900.0 1,800.0 25.00

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


65.8 0.932 36.0 0.962 0.800 1.000
0
z [mm] y M,N k1 NRk,c [kN] gM,c NRd,c [kN] NEd [kN]
492.1 1.000 7.700 565.832 1.500 315.059 448.642

Group anchor ID
5, 6, 10, 11, 14-16, 20-23, 26, 27, 30, 31, 33

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

1.4 Shear load EN 1992-4, Section 7.2.2

Load [kN] Capacity [kN] Utilization bV [%] Status


Steel failure (without lever arm)* 16.012 134.640 12 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout failure** 488.796 665.424 74 OK
Concrete edge failure in direction x-** 489.086 151.839 323 not recommended

* highest loaded anchor **anchor group (relevant anchors)

1.4.1 Steel failure (without lever arm)

V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)

0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
168.300 1.000 168.300 1.250 134.640 16.012

1.4.2 Pryout failure (concrete cone relevant)

V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · min {NRk,c; NRk,p} EN 1992-4, Eq. (7.39c)
0 A
NRk,c = NRk,c · 0c,N · y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)

2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
3,775,200 3,240,000 900.0 1,800.0 2.000 25.00

ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N y M,N


1.7 0.998 49.4 0.948 0.800 1.000 1.000
0
k1 NRk,c [kN] gM,c,p VRd,cp [kN] VEd [kN]
7.700 565.832 1.500 665.424 488.796

Group anchor ID
1-34

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

1.4.3 Concrete edge failure in direction x-

V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gM,c
0 Ac,V
VRk,c = kT · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2

= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)

lf [mm] dnom [mm] k9 a b 2


fc,cyl [N/mm ]
300.0 30.00 1.700 0.100 0.063 25.00
2 0 2
c1 [mm] Ac,V [mm ] Ac,V [mm ]
300.0 783,000 405,000

y s,V y h,V aV [°] y a,V ec,V [mm] y ec,V y re,V


1.000 1.000 2.80 1.001 26.1 0.945 1.400
0
VRk,c [kN] kT gM,c VRd,c [kN] VEd [kN]
88.942 1.0 1.500 151.839 489.086

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

1.5 Combined tension and shear loads (EN 1992-4, Section 7.2.3)
Steel failure

bN bV a Utilization bN,V [%] Status


0.376 0.117 2.000 16 OK

a a
bN + bV £ 1.0

Concrete failure

bN bV a Utilization bN,V [%] Status


1.424 3.221 1.000 388 not recommended

(bN + bV) / 1.2 £ 1.0

1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid baseplates as per current regulations (ETAG 001/Annex C, EOTA TR029,
etc.). This means load re-distribution on the anchors due to elastic deformations of the baseplate are not considered - the baseplate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the
minimum required baseplate thickness with CBFEM to limit the stress of the baseplate based on the assumptions explained above. The
proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• Attention! In case of compressive anchor forces a buckling check as well as the proof of the local load transfer into and within the base
material (incl. punching) has to be done separately.
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure
• Design is only valid if hole is filled to remove clearance, clearance as per EN 1992-4 Table 6.1
• Load transfer from supplementary reinforcement to the structural member shall be verified by the responsible structural engineer.
• With supplementary reinforcement and post-installed anchors, please ensure that in the jobsite the rebars are not drilled through.
• The anchor design methods in PROFIS Engineering require rigid baseplates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the baseplate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the baseplate is considered close to rigid by engineering judgment."
• The characteristic bond resistances depend on the return period (service life in years): 50

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

1.7 Installation data


2 2
Baseplate, steel: S 355; E = 210,000.00 N/mm ; fyk = 355.00 N/mm Anchor type and size: HIT-HY 200-A + HAS-U 5.8 M30
Profile: HD, HD 404; (L x W x T x FT) = 407.0 mm x 404.0 mm x 43.7 mm x Item number: not available (insert) / 2022696 HIT-HY
43.7 mm 200-A (mortar)
Hole diameter in the fixture: df = 33.0 mm Maximum installation torque: 300 Nm
Plate thickness (input): 70.0 mm Hole diameter in the base material: 35.0 mm
Hole depth in the base material: 600.0 mm
Drilling method: SafeSet - automatic cleaning Minimum thickness of the base material: 670.0 mm
Cleaning: Automatically performed while drilling

Hilti HAS-U threaded rod with HIT-HY 200 injection mortar with 600 mm embedment h_ef, M30, Steel galvanized, SAFEset - automatic
cleaning installation per ETA 11/0493, with annular gaps filled with Hilti Filling Set or any suitable gap solutions

1.7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • No accessory required • Dispenser including cassette and mixer
• Properly sized drill bit for SAFEset - • Torque wrench
automatic cleaning (TE-CD / TE-YD)
• Vacuum cleaner

y
460.0 460.0
55.0

23 24 25 26 27 28
140.0

17 18 19 20 21 22
475.0
140.0

12 13 29 30 15 16
140.0

7 8 10 11
x
140.0

3 4 5 6
140.0

475.0

1 9 14 2
140.0

31 32 33 34
55.0

45.0 140.0 175.0 200.0 175.0 140.0 45.0

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y Anchor x y c-x c+x c-y c+y
1 -415.0 -280.0 300.0 1,130.0 - - 18 -275.0 280.0 440.0 990.0 - -
2 415.0 -280.0 1,130.0 300.0 - - 19 -100.0 280.0 615.0 815.0 - -
3 -415.0 -140.0 300.0 1,130.0 - - 20 100.0 280.0 815.0 615.0 - -
4 -275.0 -140.0 440.0 990.0 - - 21 275.0 280.0 990.0 440.0 - -
5 275.0 -140.0 990.0 440.0 - - 22 415.0 280.0 1,130.0 300.0 - -
6 415.0 -140.0 1,130.0 300.0 - - 23 -415.0 420.0 300.0 1,130.0 - -
7 -415.0 0.0 300.0 1,130.0 - - 24 -275.0 420.0 440.0 990.0 - -
8 -275.0 0.0 440.0 990.0 - - 25 -100.0 420.0 615.0 815.0 - -
9 -275.0 -280.0 440.0 990.0 - - 26 100.0 420.0 815.0 615.0 - -
10 275.0 0.0 990.0 440.0 - - 27 275.0 420.0 990.0 440.0 - -
11 415.0 0.0 1,130.0 300.0 - - 28 415.0 420.0 1,130.0 300.0 - -
12 -415.0 140.0 300.0 1,130.0 - - 29 -100.0 140.0 615.0 815.0 - -
13 -275.0 140.0 440.0 990.0 - - 30 100.0 140.0 815.0 615.0 - -
14 275.0 -280.0 990.0 440.0 - - 31 -415.0 -420.0 300.0 1,130.0 - -
15 275.0 140.0 990.0 440.0 - - 32 -275.0 -420.0 440.0 990.0 - -
16 415.0 140.0 1,130.0 300.0 - - 33 275.0 -420.0 990.0 440.0 - -
17 -415.0 280.0 300.0 1,130.0 - - 34 415.0 -420.0 1,130.0 300.0 - -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

2 Baseplate design

2.1 Input data


Baseplate: Shape: Rectangular
lx x ly x t = 920.0 mm x 950.0 mm x 70.0 mm
Calculation: CBFEM
Material: S 355; Fy = 335.00 N/mm²; εlim = 5.00%
Anchor type and size: HIT-HY 200-A + HAS-U 5.8 M30, hef = 600.0 mm
Anchor stiffness: The anchor is modelled considering stiffness values determined from load displacement curves tested in
an independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method: EN based design using component-based FEM
Stand-off installation: eb = 0.0 mm (No stand-off); t = 70.0 mm
Profile: HD 404; (L x W x T x FT) = 407.0 mm x 404.0 mm x 43.7 mm x 43.7 mm
Material: S 355; Fy = 335.00 N/mm²; εlim = 5.00%
Eccentricity x: 0.0 mm
Eccentricity y: 0.0 mm
Base material: Cracked concrete; C25/30; fc,cyl = 25.00 N/mm²; h = 1,500.0 mm; E = 31,000.00 N/mm²; G = 12,916.67
N/mm²; v = 0.20
Welds (profile to baseplate): Type of redistribution: Plastic
Material: S 355
Mesh size: Number of elements on edge: 8
Min. size of element: 10.0 mm
Max size of element: 50.0 mm

2.2 Summary
Description Profile Baseplate Welds [%] Concrete [%]
sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] Hole bearing
[%]
1 Combination 1 84.32 0.00 59.26 0.00 2 60 9
2.3 Baseplate plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid baseplate (CBFEM) Component-based Finite Element Method
(CBFEM) baseplate
Anchor 1 -0.005 kN -0.003 kN
Anchor 2 27.627 kN 0.000 kN
Anchor 3 -0.005 kN -0.006 kN
Anchor 4 -0.004 kN -0.009 kN
Anchor 5 20.579 kN 59.892 kN
Anchor 6 28.376 kN 21.726 kN
Anchor 7 -0.005 kN -0.006 kN
Anchor 8 -0.004 kN -0.011 kN
Anchor 9 -0.004 kN -0.005 kN
Anchor 10 21.328 kN 70.384 kN
Anchor 11 29.125 kN 25.740 kN
Anchor 12 -0.005 kN -0.005 kN
Anchor 13 -0.004 kN -0.009 kN
Anchor 14 19.830 kN 36.544 kN
Anchor 15 22.076 kN 60.489 kN
Anchor 16 29.873 kN 22.492 kN
Anchor 17 -0.005 kN -0.003 kN
Anchor 18 -0.003 kN -0.005 kN

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

12
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

Anchor tension forces Equivalent rigid baseplate (CBFEM) Component-based Finite Element Method
(CBFEM) baseplate
Anchor 19 -0.002 kN -0.003 kN
Anchor 20 0.000 kN 29.966 kN
Anchor 21 22.823 kN 34.666 kN
Anchor 22 30.620 kN 3.527 kN
Anchor 23 -0.005 kN 2.998 kN
Anchor 24 -0.003 kN -0.001 kN
Anchor 25 -0.002 kN -0.001 kN
Anchor 26 0.691 kN 8.673 kN
Anchor 27 23.571 kN 3.924 kN
Anchor 28 31.367 kN -0.002 kN
Anchor 29 -0.002 kN -0.006 kN
Anchor 30 0.000 kN 50.130 kN
Anchor 31 -0.005 kN 1.240 kN
Anchor 32 -0.004 kN -0.001 kN
Anchor 33 19.080 kN 16.252 kN
Anchor 34 26.877 kN -0.002 kN

User accepted to consider the selected baseplate as rigid by his/her engineering judgement. This means the anchor design guidelines can be
applied.

2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for
critical cross sections, which should be performed outside of PROFIS Engineering.

2.4.1 Equivalent stress and plastic strain


Limit state criteria as per EN1993-1-5 Annex C.8, (1) 2.

Results
Part Load Material sEd [N/mm²] ePl [%] fy [N/mm²] gM0 fy/gM0 elim [%] Status
combination [N/mm²]
Plate Combination S 355 59.26 0.00 335.00 1.00 335.00 5.00 OK
1
Profile Combination S 355 84.32 0.00 335.00 1.00 335.00 5.00 OK
1
Profile Combination S 355 73.20 0.00 335.00 1.00 335.00 5.00 OK
1
Profile Combination S 355 60.29 0.00 335.00 1.00 335.00 5.00 OK
1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

13
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

2.4.1.1 Equivalent stress


Results below are displayed for the decisive load combination: 1 - Combination 1

335.00 N/mm²

0.00 N/mm²
2.4.1.2 Plastic strain
Results below are displayed for the decisive load combination: 1 - Combination 1

5.00%

0.00%

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

14
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 15
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

2.4.2 Hole bearing


Decisive load combination: 1 - Combination 1
Plate hole bearing resistance, EN1993-1 - 8 section 3.6.1:

Equations

k1 ab fu d t
Fb,Rd =
gM2
VEd
Utilisation =
Fb,Rd

Variables
k1 ab fu [N/mm²] d [mm] t [mm] gM2
Anchor 1 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 2 2.50 0.45 470.00 30.0 70.0 1.25
Anchor 3 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 4 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 5 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 6 2.50 0.45 470.00 30.0 70.0 1.25
Anchor 7 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 8 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 9 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 10 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 11 2.50 0.46 470.00 30.0 70.0 1.25
Anchor 12 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 13 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 14 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 15 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 16 2.50 0.46 470.00 30.0 70.0 1.25
Anchor 17 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 18 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 19 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 20 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 21 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 22 2.50 0.46 470.00 30.0 70.0 1.25
Anchor 23 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 24 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 25 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 26 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 27 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 28 2.50 0.46 470.00 30.0 70.0 1.25
Anchor 29 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 30 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 31 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 32 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 33 2.50 1.00 470.00 30.0 70.0 1.25
Anchor 34 2.50 0.45 470.00 30.0 70.0 1.25

Results

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

15
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 16
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

VEd [kN] Fb,Rd [kN] Utilisation [%] Status


Anchor 1 15.508 1,974.000 1 OK
Anchor 2 15.405 897.287 2 OK
Anchor 3 15.658 1,974.000 1 OK
Anchor 4 15.917 1,974.000 1 OK
Anchor 5 15.866 1,974.000 1 OK
Anchor 6 15.549 897.646 2 OK
Anchor 7 15.483 1,974.000 1 OK
Anchor 8 16.013 1,974.000 1 OK
Anchor 9 15.656 1,974.000 1 OK
Anchor 10 15.771 1,974.000 1 OK
Anchor 11 15.309 899.355 2 OK
Anchor 12 14.698 1,974.000 1 OK
Anchor 13 14.869 1,974.000 1 OK
Anchor 14 15.603 1,974.000 1 OK
Anchor 15 14.640 1,974.000 1 OK
Anchor 16 14.408 902.954 2 OK
Anchor 17 13.541 1,974.000 1 OK
Anchor 18 13.499 1,974.000 1 OK
Anchor 19 13.352 1,974.000 1 OK
Anchor 20 13.240 1,974.000 1 OK
Anchor 21 13.238 1,974.000 1 OK
Anchor 22 13.182 907.045 2 OK
Anchor 23 12.461 1,974.000 1 OK
Anchor 24 12.332 1,974.000 1 OK
Anchor 25 12.155 1,974.000 1 OK
Anchor 26 12.052 1,974.000 1 OK
Anchor 27 12.045 1,974.000 1 OK
Anchor 28 12.040 910.032 2 OK
Anchor 29 15.000 1,974.000 1 OK
Anchor 30 14.942 1,974.000 1 OK
Anchor 31 15.413 1,974.000 1 OK
Anchor 32 15.507 1,974.000 1 OK
Anchor 33 15.472 1,974.000 1 OK
Anchor 34 15.295 897.275 2 OK

2.5 Welds
Profiles are modelled without taking the corner radius into account. Special rules for welding (e.g. for cold-formed profiles ...) are not taken into
account by the software.

2.5.1 Baseplate to profile


Decisive load combination: 1 - Combination 1
Weld design, EN1993-1-8 section 4.5.3.2
Minimum web weld thickness (amin): 7.9 mm

Minimum flange weld thickness (amin): 7.9 mm

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

16
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 17
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

Equations

sw,Ed = (s┴2 + 3 (t┴2 + t||2))0.5


fu
sw,Rd =
bw gM2
fu
s┴,Rd = 0.9
gM2
sw,Ed |s┴|
Utilisation = max ( ; )
sw,Rd s┴,Rd
Variables
Weld bw fu [N/mm²] gM2
Web 0.90 490.00 1.25
Flange 0.90 490.00 1.25

Edge a [mm] L [mm] ePl [%] s┴ [N/mm²] t|| [N/mm²] t┴ [N/mm²]


Member 1-bfl 1 8.4 404.0 0.00 53.01 46.68 62.09
Member 1-bfl 8.4 404.0 0.00 118.12 -74.28 -109.04
Member 1-tfl 1 8.4 404.0 0.00 -107.04 74.27 -96.03
Member 1-tfl 8.4 404.0 0.00 -47.12 -47.50 58.14
Member 1-w 1 8.4 363.3 0.00 5.67 60.82 7.56
Member 1-w 8.4 363.3 0.00 6.29 -62.10 -4.40

Results
Edge sw,Ed [N/mm²] sw,Rd [N/mm²] s┴,Rd [N/mm²] Utilisation [%] Utilisationc [%] Status
Member 1-bfl 1 144.61 435.56 352.80 34 16 OK
Member 1-bfl 257.23 435.56 352.80 60 43 OK
Member 1-tfl 1 235.94 435.56 352.80 55 38 OK
Member 1-tfl 138.30 435.56 352.80 32 14 OK
Member 1-w 1 106.30 435.56 352.80 25 15 OK
Member 1-w 108.01 435.56 352.80 25 14 OK

2.6 Concrete
Decisive load combination: 1 - Combination 1
According to EN1992-1-1 section 6.7(4), the concrete should have sufficient reinforcement to take into account the tensile forces that develop
due to the fixture attachment. The definition of the reinforcement in the concrete is not within the scope of PROFIS Engineering.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

17
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 18
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

2.6.1 Compression in concrete under the baseplate


2.63 N/mm²

0.00 N/mm²

2.6.2 Verification of compression in concrete under the baseplate around the profile as per EN1992-1 section 6.7 and EN1993-1-8,
section 6.2.5

Equations

fjd
bj kj acc fck
=
gc
N
s = A
eff

Utilisation =
s
fjd

Variables
N [kN] Aeff [mm²] bj kj acc fck [N/mm²] gc
432.460 228,324 0.67 2.45 0.85 25.00 1.50

Results
s [N/mm²] fjd [N/mm²] Utilisation [%] Status
1.89 23.28 9 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

18
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 19
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

2.7 Symbol explanation


a Throat thickness of weld
ab Factor
acc Long-term effects on maximum strength of concrete
Aeff Effective area
amin Minimum weld thickness
bj Joint coefficient βj
bw Corelation factor EN 1993-1-8 tab. 4.1
d Nominal diameter of the bolt
elim Limit plastic strain
ePl Plastic strain from CBFEM results
Fb,Rd Plate bearing resistance EN 1993-1-8 tab. 3.4
fck Characteristic compressive concrete strength
fjd The ultimate bearing strength of the concrete block
fu Ultimate strength
fy Yield strength
gc Service factor - SP 16, Table 41
gM0 Steel safety factor gamma M0
gM2 Steel safety factor gamma M2
k1 Factor for edge distance and bolt spacing perpendicular to the direction of load transfer - EN 1993-1-8 - Table 3.4
kj Concentration factor
L Length of weld
N Resulting compression force
s Average stress in concrete
s┴ Perpendicular stress
s┴,Rd Perpendicular stress resistance
sEd Equivalent stress
sw,Ed Equivalent stress
sw,Rd Equivalent stress resistance
t Thickness of the baseplate
t┴ Shear stress perpendicular to weld axis
t|| Shear stress parallel to weld axis
Utilisationc Weld capacity utilisation
VEd Anchor shear force

2.8 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
baseplate may not behave rigidly. Please, have the results validated by a professional designer and/or structural engineer to ensure
suitability and adequacy for your specific jurisdiction and project requirements.
● The anchor is modelled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

19
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 20
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

3 Summary of results
Design of the baseplate, anchor, welds and other elements are based on CBFEM (component based finite element method) and Eurocode
regulations.
Load combination Max. utilisation Status
Anchors Combination 1 388% NOT OK
Baseplate Combination 1 18% OK
Welds Combination 1 60% OK
Concrete Combination 1 9% OK
Profile Combination 1 26% OK

Fastening does not meet the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

20
Hilti PROFIS Engineering 3.0.88

www.hilti.co.uk
Company: Page: 21
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - 24 Anchors - North - 50% Date: 19/09/2023
Fastening Point:

4 Remarks; Your Cooperation Duties


● Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,
formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc.,
that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be
conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based
essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the
relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and
cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility.
The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and
the relevance of the results or suitability for a specific application.
● You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you
do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the
Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery
of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

21