Panel Formwork
Poster
Tips for ensuring smooth construction
progress
TRIO
Shaft Element TSE 270,
Item no. 105523 Seal all unused tie holes with Plugs Ø 20/24,
Art.-no. 030300.
• More information can be found in the TRIO Assembly
Instructions.
WDA 10
Shaft Element TSE 120,
Item no. 105524
• This poster presents only part of the intended use of the system.
The poster may only be used in connection with the corresponding Instructions for Assembly and Use and
The panel formwork with the BFD coupler system Original Instructions.
• Without exception, all current safety regulations and guidelines must be observed in those countries where
Alignment Coupler BFD our products are used.
Only one part for
all panel connections.
85
270 x 240 6 BFD couplers 60
72
165°
TAR
75°
2,70 m
TRM
Articulated Corner ø 24
30
TRIO Wall Thickness Compensation 2. With WDA or timber TGE 270
WDA 5, WDA 6 or timber infills.
TRM 72
30 30 TRM 72 TGE
TA
30 30 R
Filler Timber TR 85
M
72
60 TGE
150° 60
Filler timber
Filler timber
2 x Alignment Coupler BFD
TE 3. With TRM 72 Item no. 023500, ≥ 75°
TE
WDA 5 (6) for 2.70 m panel heights. TAR 85
TRM 72 TGE
(18)
(36)
TAR 85
20
WDA 5 (6)
35
90
90
TA TRM
60 TGE
R8 7
TRM 72 135°
5 2
60 120°
4. With WDA
60
1. With 270 x 240 2. With TRM 72 3. With TR 30 or timber infills
WDA 5/6
TRM 72
TRM 72
2. Longitudinal Compensation
30
30
WDA 5 (6)
TRIO Column
TAR 85
TAR 85
270 x 240
270 x 240
Simple and fast solution. Cost-effective solution. Optimal visible surface solution. With elements for walls and
TE
With timber, or timber and formlining, With filler plates from 6 - 36 cm. With formlining and filler support. columns
TE and Alignment Couplers BFD up to LA 270, Item no. 023170 TPP, Alu 270, Item no. 101813
10 cm. LA 120, Item no. 023270 TPP, Alu 120, Item no. 101823 Can be used as column panels for
(24)
90
25
WDA 5
40
cross-sections of up to 75 x 75 cm.
90
TE
Used in the wall as “standard” 90 cm
TE formwork panel.
TRS 90
TRS 90
max.
TRM 72
TE 60 75 x 75
TRS 90
90
TE
TE
TE TE TRS 90
120
60
30
90
TE TE
72
TE
TRM 72
TRM 72
Corner formation:
7. Stopend Formwork 5. Wall Offsets 3. Corners wall thickness 60 cm
Perm. fresh concrete pressure 60 kN/m²
With the TRIO Stopend Panel MT/MTF for continuous Up to max. 20 cm Basic rules for corners 20 25 30 Note:
reinforcement, with or without waterstop bar. Wall thicknesses 18 - 40 cm Along the length L of 2.25 m,
60
Lower TAR 85 to be (18) (24)
fixed from below 3 BFD Alignment Couplers are
30 Adapting to required wall thickness required per panel joint.
Centre Piece MT, Centre Piece MTF,
with Wall Thickness Compensation
without waterstop bar with waterstop bar Filler timber
TAR 85
WDA 5 (6)
2 WDA 5 (6)
Internal formwork: External formwork:
30
with TRIO Corner TE with Panel TR 72, TRM 72 and TR 60
L
Timber Connection:
Connection: 5 x BFD Alignment Couplers for h =
Additional BFD for Hook Tie 2 x BFD Alignment Couplers for h = 2.70 m TE
60
TAR 85
12 cm offsets upwards DW 15/400 2.70 m TE
72
72
72
TE
270 x 240
270 x 240
Compensation
Waler TAR 85
L
TRM 72
TRM 72
wall thickness 80 cm
TRM 72
86 cm
max.
AT MT AT AT MTF AT TE
c c c c TE
TAR 85
TE
TAR 85
80
72
Push-pull props and kicker braces They are connected to the panel with
serve to align the formwork as well the appropriate brace connector. Height Extensions Extension Units (steel)
y2
For safe stacking of 5 TRIO or a crane sling angle of max. 30°. Use. The pins are used to move stacks Use. For transporting stacks of panels TRIO are simple and easy. as one unit.
y1
MAXIMO panels. Always use 2 pieces for each unit of panels at low hights. MAXIMO Lift- at low hights.
Table for PERI Push-Pull Props and Kickers - standard application 270 240 120 90 72 60 30 TE TGE TGE TE
h
FAV FAV
60° 1 60° 2 60° 1
Formwork Height h [m] System 1 Formwork Height h [m] System 2 x1 x2
x1
FA FA
240 / 270
3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00
Perm. width of influence [m] EBref 5.20 4.04 2.74 2.26 2.05 1.74 2.45 2.04 1.80 1.50 For fixing
Follow the Instructions Follow the Instructions Follow the Instructions Follow the Instructions
270
Item-no.: 124777
struction aids on reinforced concrete
components. Fixing thickness tfix 6–12 mm
1 13.7 13.7 13.5 13.4 13.7 13.9 11.5 11.0 11.5 11.5
Assembly Instructions Tightening torque MD 50 Nm
➀ ➁ Spanner size SW 24 mm Pallets and Stacking Devices Lifting Hook MAXIMO 1.5 t Lifting Gear Combi MX Lifting Gear MX
Axis spacing s ≥ 500 mm
Item no. 115168 Item no. 117321 Item no. 117322
Resulting force [kN] Distance to edge c ≥ 500 mm
Base Plate
d0
60
1 52.4 51.1 51.1 51.1 49.4 48.2 60.0 60.0 60.0 60.0 c SW 24 Interaction Equation
c
s FZ
≤ 1,0
FQ
≤ 1,0
s
FQ perm. FZ perm. FQ
db
FZ FQ
≤ 1,2
perm. FZ + perm. FQ
d
FZ
300
Lifting force VWind [kN/m] 2.1 2.6 3.8 4.6 5.1 5.9 8.4 10.0 11.4 13.2
Tube gauge
270
✓
Formwork Scaffolding Engineering
P.O. Box 1264
89259 Weissenhorn
240
Germany
✗
Tel. +49 (0)7309.950-0 1 2 3 4
Fax +49 (0)7309.951-0
info@peri.com
www.peri.com
y1
Edition 05/2011 Edition 10 | 2013
Top connection point from 1.0 1.2 1.5 1.8 1.8 1.8 1.5 1.8 2.1 2.4
y= are to be applied:
top of formwork [m] y2 4.5 5.5 6.2 6.9 L/h ≤ 3: cp, End = 2.3* L/h = 5: cp, End = 2.9*
L/h ≥ 10: cp, End = 3.4* LE = longer end area (0.3 x h) Stacking Device Lifting Hook Lifting Gear Combi MX Lifting Gear MX
q(z=h) = qh [kN/m2] 0.50 0.50 0.58 0.58 0.58 0.61 0.64 0.66 0.69 0.71 MAXIMO MAXIMO 1.5 t Item no. 117321 Item no. 117322
60
Assumptions: – Service life factor κ = 0.6 *intermediate values are interpolated Item no. 115058 Item no. 115168
– Wind loads according to DIN EN 1991-1-4 – q(z) = peak velocity pressure
330
w = q(z) x cp x κ [kN/m2] – Inclination of the push-pull prop to the horizontal 60° Formwork ground plan
– Wind Zone 2, Terrain Category III – Values are characteristic values
270
240
ig h
ht
270
240
30
120
120
390
Guardrail Post
120
HSGP-2
120
1,00
Item no. 116292
450
90
m2 0.72 0.54 0.36 0.18 0.43 0.36 Guardrail Post Holder TRIO
240
Item no. 022640 022790 022810 022820 022800 022840 The max. width of influence = 1.35 m
120
TAE TAM 72
270
Foundation Strap
240
Concreting Platform 120 x 270 Scaffold Bracket TRG 100/112 Strip foundations with
TRA 270
Item no. 022950 Item no. 023590 Foundation Tie Clamp Item no. 023010 Stop Rail
Perforated Foundation Tie Item no. 023020
An individual platform unit is only 32 cm Top Tie Bracket AH Item no. 023630
high when folded. Each additional unit
adds only 17 cm in height. As a result,
60
m 2
2.43 1.62 0.81 1.62 1.94
equal to the loading height of a truck.
240
Foundation Tie
270
240
Clamp
17
Accessories: Perforated
32
PERI GmbH
Formwork Scaffolding Engineering
Rudolf-Diesel-Strasse 19
89264 Weissenhorn
Germany
Tel. +49 (0)7309.950 - 0
Fax +49 (0)7309.951- 0
info@peri.de
www.peri.de