Professional Documents
Culture Documents
Guidelines Check List LOAD LINE RA1156
Guidelines Check List LOAD LINE RA1156
1156(32)
Annex
No. Report No. Page No. Total Pages
checking that, as far as its strength is concerned, the ship has been constructed in accordance with the
(LI) 1.1.2.1
approved plans (LLC 66/88 reg.1);
(LI) 1.1.2.2 confirming that the deck line and load line mark are properly positioned (LLC 66/88 regs.4 to 9);
(LI) 1.1.2.3 witnessing the inclining experiment or lightweight survey (LLC 66/88/03 reg.10);
(LI) 1.1.2.4 examining the superstructure end bulkheads and the openings therein (LLC 66/88 regs.11 and 12);
examining the means of securing the weathertightness of cargo hatchways, other hatchways and other
(LI) 1.1.2.5
openings on the freeboard and superstructure decks (LLC 66/88 regs.13 to 18);
examining the ventilators and air pipes, including their coamings and closing appliances (LLC 66/88 regs.19
(LI) 1.1.2.6
and 20);
examining the watertight integrity of the closures to any openings in the ship's side below the freeboard deck
(LI) 1.1.2.7
(LLC 66/88 reg.21);
(LI) 1.1.2.8 examining the scuppers, inlets and discharges (LLC 66/88/03 reg.22);
(LI) 1.1.2.9 examining the garbage chutes (LLC 66/88/03, reg. 22-1);
(LI)
examining the spurling pipes and cable lockers (LLC 66/88/03, reg. 22-2);
1.1.2.10
(LI)
examining the side scuttles and deadlights (LLC 66/88 reg.23);
1.1.2.11
(LI) examining the bulwarks including the provision of freeing ports, special attention being given to any freeing
1.1.2.12 ports fitted with shutters (LLC 66/88/03 regs.24 and 25);
(LI) examining the guardrails, gangways, walkways and other means provided for the protection of the crew and
1.1.2.13 means for safe passage of the crew (LLC 66/88/03 regs.25 and 25-1);
(LI) examining the special requirements for ships permitted to sail with type "A" or type "B-minus" freeboards (LLC
1.1.2.14 66/88/03 regs.26 and 27); and
* CONDITIONS
– WR : without remark, i.e. at the surveyor’s satisfaction
– SR : see remarks (work, repair, inventory, made) : enter remarks overleaf with item number
– NA : not applicable
(LI)
checking, when applicable, the fittings and appliances for timber deck cargoes (LLC 66/88 regs.42 to 45).
1.1.2.15
(LI) 1.1.3.1 checking that the loading and ballasting information has been supplied to the master (LLC 66/88 reg.10).
REMARKS:
* CONDITIONS
– WR : without remark, i.e. at the surveyor’s satisfaction
– SR : see remarks (work, repair, inventory, made) : enter remarks overleaf with item number
– NA : not applicable