Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ECO HYMONT™ RELAXED HEIGHT™ 1.

6 GPF
ELONGATED FLUSHOMETER TOILET SYSTEM
MANUAL FLUSH VALVE
BARRIER FREE
❍ 3H701-16S100 1.6 gpf 16-3/4" Top Spud Bowl and
Manual Flush Valve

BOWL:
• Floor mount elongated flushometer valve toilet
• Vitreous china
• High Efficiency, Low Consumption. Operates in the
range of 1.1 gpf to 1.6 gpf (4.2 Lpf to 6.0 Lpf)
• Elongated bowl
• Fully glazed 2" trapway
• 10" or 12" rough-in
• 16-3/4" rim height for accessible applications
• Powerful direct-fed siphon jet action
• 1-1/2" top spud
• 2 bolt caps included
• Less toilet seat
• Model 3H701

MANUAL FLUSH VALVE:


• Self-cleaning brass piston with integral wiper
spring prevents clogging and reduces
maintenance SEE REVERSE FOR ROUGHING-IN DIMENSIONS
• Piston operation delivers superior flush accuracy
and repeatability Operating Pressure:
• Piston valve remains closed and does not need Recommended: 25 psi (flowing)-80 psi (static)
to be reset after loss of water pressure
• Non-hold open handle Flow Requirement:
• Positive seal ensures leak-free performance 25 gpm (94.6 L/min)
• No external volume adjustment
• Durable chrome-plated cast brass construction Nominal Fixture Dimensions:
is ideal for commercial applications 713 x 381 x 425mm (28-1/16" x 15" x 16-3/4")
• Chloramine-resistant EPDM seals
• Adjustable tailpiece for rough-in flexibility Fixture Compliance Certifications -
• Can be installed left or right hand Meets or Exceeds the Following Specifications:
• ASME A112.19.2-2008 / CSA B45.1-08 for
• Model 6727.161
Vitreous China Fixtures
Includes:
Valve Listings:
• 1" I.P.S. angle stop with back-flow prevention and
vandal-resistant cap • ASSE 1037
• 1" Sweat solder kit including cover tube and wall flange • ANSI/ASME A112.19.2
• ADA Compliant
• High back pressure vacuum breaker with down tube
• Spud coupling & flange for 1-1/2" top spud

To Be Specified:
❍ Color: ❍ White
❍ Seat:
❍ Crane 8080 Lift 'n' Clean™ elongated, heavy
duty plastic, closed front toilet seat with cover.
Seat can be removed quickly for easy cleaning.

3
© 2012 AS America Inc. 4/12
ECO HYMONT™ RELAXED HEIGHT™ 1.6 GPF
ELONGATED FLUSHOMETER TOILET SYSTEM
MANUAL FLUSH VALVE
BARRIER FREE

FINISHED WALL

18-1/2"
(470mm)

15"
(381mm)

14"
(356mm)

4-1/4" to 5-1/4"
3-1/2"-5-1/2" (108-133mm)
(89-140mm)

SUPPLY
DN 25mm
(1" I.P.S.)
-C-L-
28-1/16"-30-1/16" *CRITICAL 11-1/2"
(713mm-746mm) LEVEL (295mm)
6"
(152mm)
30-1/4" (Min.)
(768mm)

16-3/4" 28-1/4"
(425mm) (720mm)

10"-12"
(254mm-305mm) C/L OF FINISHED FLOOR
OUTLET
24-1/16"
(612mm) *VARIABLE-CHECK WITH MANUFACTURER OF
FLUSH VALVE FOR PROPER ROUGH-IN DIMENSIONS.

NOTES:
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM
BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY
DIMENSIONS SHOWN FOR SUPPLY ROUGHING.
THIS TOILET DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION
OF 254MM (10") AND A MAXIMUM DIMENSION OF 305MM (12") FROM
FINISHED WALL TO C/L OF OUTLET.
FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE
ORDERED SEPARATELY. FLUSHOMETER VALVE REQUIREMENTS FOR
12" (305MM) ROUGH-IN: SWEAT EXTENSION NIPPLE IS REQUIRED.
REFER TO VALVE MANUFACTURER AND LOCAL CODES.

IMPORTANT: Dimensions of fixtures are nominal and may vary within


the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.

MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES


AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES - CHECK LOCAL CODES.

4
© 2012 AS America Inc. 4/12