Professional Documents
Culture Documents
Astm D4491
Astm D4491
Astm D4491
for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D4491/D4491M − 17
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
D4491/D4491M − 17
versus time in the falling head test. The constant head test is the be taken when attempting to apply the results of these test
referee method for this standard. methods to the field performance of a geotextile.
NOTE 1—Data has shown agreement between the falling and constant 5.2 Since there are geotextiles of various thicknesses in use,
head methods of determining permittivity of geotextiles.4 Selection of the evaluation in terms of their Darcy coefficient of permeabilities
test method, that is, constant or falling head, is left to the technician
can be misleading. In many instances, it is more significant to
performing the test.
evaluate the quantity of water that would pass through a
4.1.2 Method B – Falling Head Test—A column of water is geotextile under a given head over a particular cross-sectional
allowed to flow through the geotextile and readings of head area; this is expressed as permittivity.
changes versus time are taken. The flow rate of water through
the geotextile must be slow enough to obtain accurate readings. 5.3 If the permeability of an individual geotextile is of
4.1.3 Method C – Air Flow Test—A geotextile specimen is importance, a nominal coefficient of permeability, as related to
subjected to increasing air flow while the flow rate and geotechnical engineering, may be computed. By multiplying
differential pressure are measured. Two flow rate data points permittivity times the nominal thickness of the geotextile, as
are obtained at pressures of 250 and 500 Pascals, which are determined by Test Method D5199, the nominal coefficient of
used to determine the Characteristic Flow Equation of the permeability is obtained.
specimen. The water permittivity at 50-mm water head is then NOTE 2—The nominal thickness is used as it is difficult to evaluate the
calculated using the conversion algorithm described in this pressure on the geotextile during the test, thereby making it difficult to
standard. determine the thickness of the fabric under these test conditions.
2
D4491/D4491M − 17
6.4.2.2 The tail (downstream) pressure sensor must be 6.4.3.1 Specimen holder for the test specimens that fully
installed 25 mm or more from the geotextile test specimen, and confines the perimeter of the specimen to prevent any lateral
within the 25-mm diameter section. pressure losses.
6.4.3 Closed Specimen Holder:
3
D4491/D4491M − 17
6.4.3.2 The specimen flow area shall be 25- to 50-mm oxygen content down to a maximum of six parts per million.
diameter. Smaller diameter devices are not acceptable. The dissolved oxygen content may be determined by either
6.4.3.3 The filter holder should be checked for leaks by commercially available chemical kits or by a dissolved oxygen
placing an impermeable membrane in the holder and increasing meter.
the pressure to the maximum capacity of the pressure sensor NOTE 4—The de-airing system may be either a commercially available
and holding it for a period of one minute. The flow rate system or one consisting of a vacuum pump capable of removing a
measured during this period must be zero indicating a leak-free minimum of 150 L/min of air in connection with a non-collapsible storage
seal. tank with a large enough storage capacity for the test series, or at least one
6.4.4 Metal Punch, used to cut a suitable size geotextile specimen at a time.
from the test sheet to fit the test specimen holder. 8.2 Allow the de-aired water to stand in a closed storage
6.4.5 Flow Rate Measurement Sensors—The apparatus tank under a slight vacuum until room temperature is attained.
should be equipped with a digital flow meter to measure the 8.3 The test water must be maintained at the standard
flow rates at the two desired pressures. The flow meter must atmosphere for geosynthetic testing which is 21 6 2 °C.
have an accuracy of at least 60.5 lpm or 1.0 % of the measured
value, whichever is larger. 9. Specimen Preparation
6.4.6 Flow Section—The geometry of the air flow apparatus 9.1 To obtain a representative value of permittivity, take
at the section where the test specimen is located shall have a four specimens from each full width laboratory sample as
uniform pipe diameter equal to the flow area, both upstream described below.
and downstream of the test specimen, for a minimum distance 9.2 Referring to Fig. 2, select four specimens, A, B, C, and
of two diameters. D, as follows:
7. Sampling 9.2.1 Select four specimens equally spaced across the width
of the sample. For woven geotextiles, take the test specimens
7.1 Lot Sample—As a lot sample for acceptance testing, take along a diagonal line extending from the lower left-hand corner
at random the number of rolls of geotextile directed in an to the upper right-hand corner of the laboratory sample. None
applicable material specification or other agreement between of the test specimens shall be closer to the corner of the
the purchaser and the supplier. Consider rolls of geotextile to laboratory sample than 200 mm [8 in.].
be the primary sampling units. If the specification requires 9.2.2 For the Method C air flow tests, take ten test speci-
sampling during manufacture, select the rolls for the lot sample mens equally spaced across the width of the sample. For woven
at uniformly spaced time intervals throughout the production geotextiles, take the ten test specimens equally spaced along a
period. diagonal line extending from the lower left hand corner to the
NOTE 3—An adequate specification or other agreement between the upper right hand corner of the laboratory sample. None of the
purchaser and the supplier requires taking into account the variability specimens shall be closer to the edge of the laboratory sample
between rolls of geotextile and between specimens from a swatch from a than 200 mm [8 in.].
roll of geotextile so as to provide a sampling plan with a meaningful
producer’s risk, consumer’s risk, acceptable quality level, and limiting 9.2.2.1 Five test specimens may be obtained in lieu of ten if
quality level. the air flow device has a flow area of 50-mm diameter,
7.2 Laboratory Sample—Take for the laboratory sample a provided the test result complies with the Method A result in
full roll width sample extending a minimum of 1 m along the accordance with 16.7.
selvage from each sample roll such that the requirements of 9.2.3 Cut specimens shall fit the testing apparatus, for
Section 9 can be met. Take a sample that will exclude material example, 73 mm [2.87 in.] in diameter for the device illustrated
from the outer wrap of the roll or the inner wrap around the in Fig. 1.
core unless the sample is taken at the production site, at which NOTE 5—If the illustrated device is used for the water flow tests, the
point inner and outer wrap material may be used. specimens are attached to the specimen ring by contact cement.
9.3 Condition the water flow test specimens by soaking in a
8. Test Water Preparation – Water Flow Tests closed container of de-aired water, at room conditions, for a
8.1 To provide reproducible test results, the test water used minimum period of 2 h. The minimum specimen diameter is to
for the water flow tests shall be de-aired to bring the dissolved be 50 mm [2 in.].
4
D4491/D4491M − 17
10. Operator Process Control holding the head at 50 mm [2 in.]. Make at least five readings
10.1 Water Flow Apparatus: per specimen and determine an average value of permittivity
10.1.1 Prepare four specimens of a No. 200 standard U.S. for the specimen.
mesh sieve to fit the test apparatus. NOTE 7—The quantity of flow may be measured in millilitres and then
10.1.2 Following Section 11 or Section 13, depending on converted to cubic millimetres for the computation of permittivity
the method to be used for the geotextile specimens, perform (1 mL = 1000 mm3).
testing on each mesh specimen. 11.7 After the first specimen has been tested under a 50-mm
10.1.3 Based on an interlaboratory test, involving seven [2-in.] head, using the same specimen, start with a 10-mm
laboratories, the permittivity of No. 200 standard U.S. mesh [3⁄8-in.] head and repeat the procedure. Increase the head by
sieve material has been determined to be 5.00 s−1, with a 5 mm [3⁄16 in.] after every five readings. Increase the head until
standard deviation of 0.65. a 75-mm [3-in.] head is reached. Use this data to determine the
10.1.3.1 New operator process control shall be performed region of laminar flow. Plot volumetric flow rate, v (where v
until it is demonstrated that the operator is proficient in test equals Q/At, values defined in 12.1), versus head. The quantity
performance as demonstrated by obtaining the value of per- of flow (Q) should be corrected to 20 °C [68 °F]. The initial
mittivity stated in 10.1.3, plus or minus two standard devia- straight line portion of the plot defines the region of laminar
tions. flow. If the 50-mm [2-in.] head is outside the region of laminar
10.1.3.2 Following initial proficiency testing, the operator flow, repeat the test procedure using the head of water in the
shall perform process control testing on a semi-annual basis. mid-region of laminar flow.
10.2 Air Flow Apparatus: 11.7.1 Compare the data from 11.7 with the apparatus
10.2.1 Using a reference orifice plate that has been cali- calibration curve referred to in 6.2. The apparatus calibration
brated for flow rate and pressure over the range that the flow plot of volumetric flow rate versus head should plot well above
meter is used for the testing, perform the dry air flow test at the the same plot for the geotextile specimen (see Fig. 3). If the
ramp rate used for the permittivity testing. specimen curve intersects the calibration curve, the apparatus
10.2.2 The resulting flow rate versus pressure curve should is controlling the flow through the geotextile rather than the
not deviate from the reference disc plot by more than 0.50 % at structure of the geotextile itself. In such an instance, modify the
any point along the plots where flow rate values are obtained apparatus by enlarging the discharge pipe so that the device
for this test method. does not control the flow.
10.2.3 New operator process control tests shall be per-
formed on an annual basis. 11.8 Repeat 11.1 – 11.6 with the remaining specimens.
METHOD A – CONSTANT HEAD TEST 12. Calculation – Constant Head Water Flow Test
11. Procedure A – Constant Head Water Flow Test 12.1 Calculate the permittivity, ψ, as follows:
ψ 5 QRt /hAt (1)
11.1 Assemble the apparatus with the specimen in place.
11.2 Open the bleed valve and backfill the system through
the standpipe or discharge pipe, with de-aired water. Backfill-
ing in this manner forces any trapped air out of the system and
the geotextile.
NOTE 6—For the water flow apparatus shown in Fig. 1, the water should
be at the bottom level of the specimen at the time of specimen installation.
11.3 Close the bleed valve once water flows from it.
Continue to fill the apparatus with de-aired water until the
water level reaches the overflow.
11.4 With water flowing into the system through the water
inlet, adjust the discharge pipe along with the rate of water
flowing into the apparatus to obtain a 50-mm [2-in.] head of
water on the geotextile. This is the head (h) under which the
test will be performed initially.
11.5 Submerge a tube attached to a source of vacuum to just
above (10 mm [0.5 in.]) the surface of the geotextile, moving
the tube gently over the surface while applying a slight vacuum
in order to remove any trapped air that may be in or on the
specimen. If necessary, readjust the head to 50 mm [2 in.] after
removing the vacuum.
11.6 Record the values of time (t), quantity of flow (Q) as
collected from the discharge pipe, and water temperature (T), FIG. 3 Calibration Curve
5
D4491/D4491M − 17
TABLE 1 Viscosity of Water Versus Temperature where:
Temperature, °C Viscosity (×10–3 kg/s · m) Correction Factor, Rt A A = πD2/4—cross-sectional test area of specimen, mm2,
19 1.027 1.025 a = πd 2 /4—cross-sectional area of standpipe above
20 1.002 1.000
21 0.978 0.976
specimen,
22 0.954 0.952 t = time for head to drop from h0 to h1, s,
23 0.932 0.931 h0 = initial head (80 mm),
A
Alternatively, the correction factor, Rt, can be calculated with: R t 51.4751 h1 = final head (20 mm), and
20.0237*T, where T is in degrees centigrade. Rt = temperature correction factor determined from Eq 2.
14.2 Repeat the calculations for the five sets of data per
specimen.
14.3 Determine the average permittivity for the individual
where: specimens tested.
ψ = permittivity, s−1,
Q = quantity of flow, mm3, METHOD C – AIR FLOW TEST
h = head of water on the specimen, mm,
A = cross-sectional area of test area of specimen, mm2, 15. Procedure – Air Flow Test
t = time for flow (Q), s, and
Rt = temperature correction factor determined using Eq 2. 15.1 After air drying the test specimens, place the first test
specimen in the specimen holder and place the specimen holder
R t 5 u t /u20c (2) in the air flow apparatus.
where: 15.2 Slowly increase the air pressure to a minimum of
ut = water viscosity at test temperature, millipoises, as 500 Pascals pressure while obtaining the flow rate values at
determined from Table 1, and 250 and 500 Pascals pressure.
u20c = water viscosity at 20 °C, mP. 15.2.1 Use a maximum pressure ramp rate of 1 Pascal per
12.2 Calculate the permittivity for the five sets of readings second. Faster ramp rates may be used on a product-by-product
per specimen at the 50 mm [2 in.] head. basis provided the results are not influenced by more than
0.5 %.
12.3 Determine the average permittivity for the individual
specimen tests. 15.3 Remove the test specimen from the filter holder, and
repeat the procedure on the remaining specimens.
METHOD B – FALLING HEAD TEST
16. Calculations – Air Flow Test
13. Procedure – Falling Head Water Flow Test 16.1 Calculate the flow velocity in m/s at 250 and 500 Pas-
13.1 Proceed as in 11.1 through 11.5. (Warning—The cals pressure. The flow velocity equals the flow rate in m3/s
falling head procedure should not be performed for geotextiles divided by the measured opening area in units of m2.
with a permittivity greater than 0.05 sec–1, unless the system is 16.2 Use the two velocity and pressure values, P250, V250
equipped with an automated data acquisition system that would and P500, V500, to calculate the two coefficients of the pressure
measure elapsed time for the drop in head from 80 to 20 mm versus velocity relationship for the air flow test:
on the manometer.) P 5 C 2A V 2 1C 1A V (4)
13.2 For the water flow apparatus shown in Fig. 1, adjust the
where:
discharge pipe so that its outlet is slightly above the level of the
specimen. P = pressure, Pascals (N/m),
V = flow velocity, m/s,
13.3 By increasing the flow from the water supply, adjust C2A = second order air flow coefficient, and
the water level to 150 mm [6 in.]. Once the water is at this C1A = first order air flow coefficient.
level, shut off the water supply and allow the water level to fall
16.2.1 Calculate the coefficients C1 and C2:
to 80 mm [3.2 in.]. At this point, start the stop watch and
determine the time for the water level to fall to the 20-mm C 2 5 $ ~ P 500 ⁄ V 5002 ! 2 ~ P 250 ⁄ ~ V 250 V 500!! % ⁄ ~ 1 2 V 250 ⁄ V 500! (5)
[4⁄5-in.] level. Record the inside diameter (d) of the upper unit, C 1 5 P 250⁄V 250 2 V 250C 2 (6)
the diameter (D) of the exposed portion of the specimen, and 16.3 Convert the coefficients of the air equation to the
the water temperature (T). Make at least five readings per corresponding water flow equation constants as follows:
specimen. All measurements in 13.3 are in relation to the outlet
water. C 2W 5 C 2A *833 (7)
where:
14. Calculation – Falling Head Water Flow Test C2W = second order water flow coefficient,
14.1 Calculate the permittivity, ψ, as follows: C1W = first order air flow coefficient,
ψ 5 @ ~ a/At! 1n ~ h 0 /h 1 ! # R t (3)
C2A = second order air flow coefficient,
6
D4491/D4491M − 17
7
D4491/D4491M − 17
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222
Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http://www.copyright.com/