Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Field Density Test (ASTM D-6938)

CUSTOMER NAME International Union Cont Est REPORT NO. 26388


PROJECT NAME SGCP-IUC RFI NO. 43615
PROJECT LOCATION MLV3
CUSTOMER ADDRESS P.O Box 6196, AL AHSA 31982, SAUDI ARABIA
MATERIAL DESCRIPTION Select Fill JOB/ CONT # 10-01996-0006
TESTED BY Jehangir Hasan DATE OF TEST September 14, 2023
EQUIPMENT SERIAL # 68088 EQUIPMENT MAKE Troxler
CALIBRATION DATE September 20, 2022 EQUIPMENT MODEL 3440 Plus
CALIBRATION DUE DATE September 20, 2023 DATE REPORTED September 18, 2023
SAMPLE REFERENCE NO. 25317
Lab. Maximum Dry Density 1970 kg/m3 Optimum Moisture Content 7.7 % Spec. Requirement (Compaction) 95 %

FIELD
DEPTH MOISTURE DRY DENSITY WET DENSITY COMPACTION
TEST # LATITUDE LONGITUDE CONTENT

mm % Kg/m3 Kg/m3 %
1 +24 1 10.20 +49 9 3.78 200 7.0 1904 2037 96.6
2 +24 1 10.62 +49 9 3.12 200 8.0 1968 2125 99.9
3 +24 1 11.22 +49 9 2.64 200 6.7 1876 2002 95.2
4 +24 1 12.24 +49 9 1.44 200 9.4 1939 2121 98.4
5 +24 1 12.12 +49 9 0.97 200 5.3 1972 2077 100.1
6 +24 1 11.82 +49 9 0.72 200 4.7 1939 2030 98.4
7 +24 1 10.62 +49 8 59.28 200 5.4 1925 2029 97.7
8 +24 1 10.26 +49 8 58.97 200 8.5 1895 2056 96.2
9 +24 1 10.20 +49 8 58.74 200 5.1 1892 1988 96.0
10 +24 1 10.14 +49 8 58.92 200 8.3 1926 2086 97.8
11 +24 1 9.30 +49 8 58.97 200 8.3 1912 2071 97.1
12 +24 1 9.12 +49 8 59.22 200 8.0 1819 1965 92.3
13 +24 1 9.00 +49 8 59.28 200 5.3 1878 1978 95.3
14 +24 1 8.82 +49 8 59.46 200 6.4 1926 2049 97.8
15 +24 1 7.98 +49 9 0.42 200 7.1 1945 2083 98.7
16 +24 1 7.74 +49 9 1.03 200 6.9 1960 2095 99.5
17 +24 1 9.12 +49 9 2.70 200 8.6 1927 2093 97.8
18 +24 1 9.06 +49 9 3.00 200 4.7 1889 1978 95.9

Reviewed and Verified By:


Muhammad Ismail (Lab. Supervisor)
CTTA # 1238

This is a computer-generated document. No signature is required


Disclaimer: 1.The test values represent the quality and quantity of specimens taken in compliance with above mentioned ASTM standards and tested in laboratory only.
2.Without RICI written consents, regeneration of this report is not acceptable.
3.This certificate remains the property of RICI and shall be returned immediately upon request.
Form # Revision No. Page Issue date
FDT-01 02 1 of 1 July 21, 2022

‫ﺷﺮﻛﺔ آر أي ﺳﻲ أي اﻟﻣﺣدودة‬
RICI Company Ltd.
‫ ﺗﻘﺎطﻊ اﻟﮫﻔوف‬،‫ طﺮﻳق اﻷﺣﺳﺎء‬- ‫اﻟﺧﺑﺮ‬
Khobar - Al Hassa Highway, Hafoof Junction
٣١٩٥٢ ‫ اﻷﺣﺳﺎء‬- ‫ اﻟﻣﻧطﻘﺔ اﻟﺷﺮﻗﻴﺔ‬- ‫اﻟوزﻳﺔ‬
Al Waziyah - Eastern Province - Al-Hassa 31952
‫ﻋﻧوان اﻟﻣﻛﺘب اﻟﺮﺋﻴﺳﻲ‬
CR: 2050241249 | T: +966 138590481 | F: +966 138590486
+ ١٣٨٥٩٠٤٨١ :‫ | ھﺎﺗف‬٢٠٥٠٢٤١٢٤٩ :‫ اﻟﺳﺟل‬١٣٨٥٩٠٤٨٦ :‫ ﻓﺎﻛس‬+ ٩٦٦ ٩٦٦
Email: info@ricionline.com | Website: www.ricionline.com
www.ricionline.com: ‫ اﻟﻣوﻗﻊ اﻻﻟﻛﺘﺮوﻧﻲ‬info@ricionline.com : ‫اﻟﺑﺮﻳد اﻻﻟﻛﺘﺮوﻧﻲ‬