Sr. Question Answer A AnswerB Answer C Answer D Answer Ans


No. E wer
1. The configuration software for woodward Governor is Wonderware Toolbox GAP software Procon None C
2. Number of inputs that can be connected to a thermocouple 4 8 10 12 6 E
TRIO is
3. The operating system of APC DEC Alpha machine is Open VMS UNIX WINDOWS 95 WINDOWS NT DOS A
4. The purpose of IP21 of cracker is to Supply data to Maintain history Supply data to All the above None D
APC optimizer
5. The function of CCC’s performance controller is to Control speed Control surge Control flow Suction pressure None D
control
6. Total no of sub systems in the cracker DCS system is 30 32 29 28 31 A
7. Number of nodes in the Modbus plus network of the ESD 4 10 12 8 6 E
PLC in cracker is
8. In woodward Governor all field inputs are directly Kernel A, Kernel B Kernel A & Kernel Kernel B & Kernel A & TRIOs B
connected to & Kernel C C Kernel C Kernel B
9. Number of APC controllers in cracker is 28 32 36 25 24 28
10. What is the model No of PSA PLC 984-785 Quantum 984-685 984-885 None C
11. Basic purpose of woodward system is to control Flow thr' Suction pressure Turbine speed Plant load None C
compressor
12. All computers of hazira are connected thr' Local area network DCN Network Modbus Satellite None A
Network
13. How many CPUs Woodward 509 governor has? 1 2 3 4 5 C
14. What sensor is used in viscosity analyzer? FID Vibrating fork DP sensor Thermocouple RTD C
15. System Fault Detection in Hydra Step is done in I/p Board Display Board O/p Board Relay Board None A
16. Draft in the furnace can be controlled by O 2 Content of fuel Damper operation Fuel gas flow Cot Temp None B
gas
17. The extreme position of MOV is sensed by Capacitance switch LVDT RVDT Reed Switch IR Switch D
18. Drum level Feed forward control element is BFW Steam Flow Steam pressure Drum level None of B
these
19. Deareator is meant for Conductivity pH control Oxygen Control Drum Level Drum C
control control Pressure
20. In Hart Type Transmitter the Zero Signal Represented by 100 Hz 120 Hz 2200 Hz 2400 Hz 1MHz C
21. Nucleonic Level transmitter Density compensation is done Temperature signl By externally Done by Not required None D
by directly to Nuc through DCS transmitter
Transmitter software look up
table
Page 1 of 3
Question Bank
Sr. Question Answer A AnswerB Answer C Answer D Answer Ans
No. E wer
22. For uncompensated pH transmitter pH shall ------ as temp Increase Decrease Does not Depend on None A
increases Change service
23. Frequency of light rays In IR Detector system is 9.8 nm 4.3 nm 6.2n 7.1nm 8.4nm B

24. Measuring sensor for fisher make displacer transmitter is LVDT Potentiometer Capacitance Hall effect None D
based on
25. Radiation pyromenter cyclops 339 used in cracker can 30 to 1200 °C 200 to 1250 °C 450 to 1300 °C 500 to 1500 °C None C
measure temperature range
26. LI 2013-2 Nuclonic level transmitter has two sources Process fluid Process fluid Vessel dia. is Vessel height is None A
bacause density is high density is low small small
27. Radar type level Tx LT 2018 used in cracker works on the FMCW AM signal Single Low frequency None A
principle of frequency
28. In DMCPLUS Controller , DMC Stands for Dynamic Matrix Digital Matrix Device Matrix Distributed None A
Control Control Control Matrix Cotrol
29. The present Engineering Station version is 1.1 1.7/2 2.6/0 2.7/4 None D
30. The Subnet Mask for Plant TCP/IP Network is 255.255.0.0 255.255.255.0 255.0.0.0 100.0.0.0 None B
31. In LoopFCM, FCM Stands for Future Class Fine Class Module Function Class Function None C
Module Module Controller
Module
32. What is the Suitable Sensor MOC for H2 service Gold plated SS Gold plated Hast Tantalum Monel Stellite A
transmitters
33. The default UPDATE rate for DCS Graphics is 1 Second 0.1 Second 4 Second 6 Second None C
34. The minimum Trend rate for DCS Loop is 0 Second 12 Second 3 Second 6 Second None D
35. The Modicon 785 CPU requests for Scan to I/O DROP at 0.5 ms 1.0 ms 1.5 ms 2 ms 3 ms B
interval of
36. Thermowell MOC Installed in Furnace COT's Solid Stellited SS 316 SS316 + Stellite SS 316 L None A
37. The o/p of displacer type level Transmitter in case of Density Depend 0% 50 % Bad o/p 100 % B
punctured displacer is
38. The no of Analog I/P and Analog O/P Channels for Analog 4/4 2 /4 6 /2 2 /5 4 /2 E
TRIO is
39. CGC does not trip on Bearing Temp Suction Drum Axial Vib Radial Vib None A
Level
40. The no of SC Controller systems in cracker is 09 08 10 12 None C
41. The GCS term in APC Controller stand for Graphical Control Graphical Graphical Close Graphical Core None A
Page 2 of 3
Question Bank
Sr. Question Answer A AnswerB Answer C Answer D Answer Ans
No. E wer
System Communication System System
System
42. Smart Barrier Model used in Analog input to DCS in MTL3021 MTL 4041B MTL 787 + MTL 4041A None B
43. Moisture analyzers used in cracker works on principle of IR Capacitance Paramagnetic Vibrating None B
44. O2 Analyzer used in Flare works on principle Paramagnetic IR Electronic Cell Zirconia None A
45. DMCPLus Controller writes set point to DCS at interval of 1 Sec 2 Sec 1 Min 2 Min None D
46. IN Analyzer Management System (H&B) , HCI-H Stands Hiway Host Computer Host Host Control None B
for Communication Interface - Hiway Communication Interface -
Interface - Hiway Interface- Hiway Hiway
47. MTL Koyo PLC in cracker is used for ESD System CPU interface to PSA Area Interface CCC None D
DCS System to DCS
48. Bridge Multiplexer in PLC System is used for converting Modbus Plus to Modbus Binary to RS232 to RS422/485 to None A
Modbus Binary Modbus Plus RS422/422 RS232
49. Which detector is not used in Cracker Gas Chromatographs TCD FID LVFD FPD ECD E
50. Which Carrier Gas is used in Cracker Gas Chromatorgrahs Argon Neon Oxygen Nitrogen None D