Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6

REV DESCRIPTION DATE/BY


XMD076 TYPICAL WIRING REFERENCE DIAGRAM
THIS DRAWING IS NOT AN ACTUAL AIRCRAFT INSTALLATION
"WEATHER DATA ON/OFF" A CHANGED ANT OUT NOTE 10/26/04 JDH
AND IS TO BE USED AS REFERENCE ONLY. ACTUAL AIRCRAFT
INSTALLATION CONFIGURATIONS ARE TBD BY INSTALLER.

14-28VDC BUS 5
XMD RECEIVER, RS232 TYPE 8 1
P/N: XMD076-01 6
D MAIN INTERFACE (J1 DB37P) DB37S 4 D
POWER INPUT 19
POWER POWER ENABLE 18
POWER GND 37 POWER GND BUS

NOTES: UNLESS OTHERWISE SPECIFIED

RS232 TX 22 1. ALL EQUIPMENT AND WIRING TO BE INSTALLED PER A/C


WEATHER DATA OUTPUT RS232 RX 4 MANUFACTURER AND FEDERAL AVIATION REQUIREMENTS,
BAUD = 115.2K RS232 GND 23 AS REQUIRED.
PARITY = NONE RX INTERCONNECT TO
DATA BITS = 8 TX MFD RS232 COM PORT 2. ALL WIRE PER M22579/16-22 AND CABLE PER M27500
STOP BITS = 1 7 RTN REFER TO MFD INSTALLATION 22TE3T14 OR AS REQUIRED BY AIRCRAFT REQUIREMENTS.
DOCUMENTATION FOR CONNECT
7
RF COAXIAL CABLE SHALL BE RG400 OR RG142.
C 3 MAXIMIUM ALLOWED CABLE LENGTH SHALL C
NOTE: MAX LENGTH 50 FEET BE 40 FEET, INCLUDING ANTENNA TO RECEIVER
AND RECEIVER TO RECEIVER RUNS.

4 RECOMMENDED MATING CONNECTORS AND ARE


INCLUDED IN INSTALLATION KIT.
(SMA PLUG, STRAIGHT) TYCO/AMP P/N 225532-3
(SMA PLUG, R/A) TYCO/AMP P/N 225609-3
(DB37S) M24308/2-4F

OTHER CONNECTORS USED ARE BE TBD


BY INSTALLER.
POWER BUS VOLTAGE SHALL NOT EXCEED
5 RTCA/DO160D CATEGORY B AND Z.

ALL WIRE, CABLE AND EQUIPMENT SHOWN FOR


6 REFERENCE ONLY. TO BE SUPPLIED BY INSTALLER/USER.
B B

7 MOUNTING STRUCTURE SHALL PROVIDE CHASSIS


GROUND CONNECTION TO AIRFRAME GROUND. CABLE
SHIELDS TO BE TERMINATED TO CONNECTOR BACKSHELL.

ENERGIZE (APPLY 14-28VDC/30mA) POWER ENABLE


8 FOR UNIT OPERATION. USE SWITCH AS SHOWN OR
XMR ACTIVE ANTENNA MODULE OR JUMPER DIRECT TO POWER WIRE.
P/N: XMRANT-XX
4
ANTENNA IN (SMA JACK)
OUT
3
ANTENNA OUT (SMA JACK)
OPTIONAL 4
ANTENNA DAISY-CHAIN
OUTPUT TO NEXT RECEIVER
7 SMA PLUG TO ANT.
VERIFY TERMINATOR IS INSTALLED DRAWN: DATE:
A IF NOT USED (INSTALLED AT FACTORY) HEADS U P TECHNOLOGIES A
(HEADS UP P/N CON428) JOHN HEADER 05/26/04 2033 Chennault Dr. Suite 100
CHECKED: DATE: Carrollton, Texas 75006-5097
MICHELLE WOOTTON 05/27/04 DESCRIPTION:
ENGINEER: DATE: WIRING REFERENCE DIAGRAM
JOHN HEADER 05/26/04 XMD WEATHER DATA, RS232 TYPE
APPROVED: DATE: SIZE DRAWING NUMBER
B XMD076-3A
N/A
RELEASED: DATE: SHEET REV FILE ..\install\xmd\
N/A 1 OF 1 A xmd076-3A.asc
1 2 3 4 5 6