Caja de Montaje BB-R Kidde 75-000000-006

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Effective: June 2007

Alarm Signals
TM
R

Installation Data
Protection Systems
A UTC Fire & Security Company
F-75-008.A
Note: All mounting plates and backboxes must be ordered separately. Select largest backbox shown in mounting
options where possible to provide additional room for easy installation.

(A) DBB BACKBOX (B) ISP SURFACE EXTENDER


Standard deep steel backbox provided with knockouts for interior sur- Use indoors.
face mounting, concealed conduit mounting or semi-flush applications.
It is painted to match the signal.
51/4 sq.

3 45/64 4 5/32
29/32
3 45/64

25/32
4 5/32

MAXIMUM NUMBER OF CONDUCTORS

AWG #18 AWG #16 AWG #14 AWG #12

8 8 8 8

(C) BB BACKBOX (D) SBB BACKBOX


Standard steel backbox with knockouts for interior surface mounting, For surface mounting.
concealed conduit mounting or semi-flush applications.

MAXIMUM NUMBER OF CONDUCTORS


MAXIMUM NUMBER OF CONDUCTORS
AWG #18 AWG #16 AWG #14 AWG #12
AWG #18 AWG #16 AWG #14 AWG #12
4 4 4 4
8 8 8 8

(E) WBB WEATHER RESISTANT BACKBOX (F) SFP SEMI-FLUSH PLATE


Sturdy die cast housing, threaded conduit hole and knockout for out- Stamped aluminum surface wall plate which mounts behind the basic
unit and serves to cover recessed backboxes in semi-flush mounting
door applications.
applications.

MAXIMUM NUMBER OF CONDUCTORS

AWG #18 AWG #16 AWG #14 AWG #12

4 4 4 4
(G) AP ADAPTER PLATE (H) IOB BACKBOX
Stamped aluminum adapter plate designed for applications where semi- For surface mounting.
flush installation cannot be used. The plate can be mounted to standard
octagon or round backboxes, single or double gang boxes or plastic
rings. The backbox and basic unit are then fastened to the plate. This
type mounting is referred to as a concealed conduit installation.

6
5/16
3 3/8

6
#8-32
3 3/8
TAP MAXIMUM NUMBER OF CONDUCTORS
(4)
HOLES AWG #18 AWG #16 AWG #14 AWG #12

8 8 8 8

(I) 4” SQUARE, DEEP, FLUSH (BO) (J) FSB1 FLUSH STROBE BACKBOX AND RP RETROFIT PLATE
Special steel backbox with knockouts. FSB1 Flush Strobe box to be
used with RP.

MAXIMUM NUMBER OF CONDUCTORS

AWG #18 AWG #16 AWG #14 AWG #12

8 8 8 8

(K) DOUBLE-GANG, FLUSH (BO) (L) 4” SQUARE, DEEP W/EXTENSION RING, FLUSH (BO)

2-1/8” Deep 1-1/2” Deep


2-1/8”DEEP

MAXIMUM NUMBER OF CONDUCTORS


DEPTH
AWG #18 AWG #16 AWG #14 AWG #12
MAXIMUM NUMBER OF CONDUCTORS
2-1/8" 8 8 8 8
AWG #18 AWG #16 AWG #14 AWG #12
1-1/2" 8 8 8 4
4 4 4 4

-2-
(M) SHBB SURFACE BACKBOX (N) SBL-2 SURFACE BACKBOX

1-11/16”
11/16”
1.562 REF 6-7/64”

KNOCKOUTS 3-3/8”
FOR 1/2”
CONDUIT 10-15/16”
(EACH SIDE)

3-3/8”

(O) SINGLE GANG, FLUSH (BO) (P) 4” SQUARE, FLUSH (BO)

2” Deep

MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS

AWG #18 AWG #16 AWG #14 AWG #12 AWG #18 AWG #16 AWG #14 AWG #12

4 4 4 4 4 4 4 4

(R) WPSBB-R
(Q) DOUBLE-GANG, SURFACE (BO)
For surface mounting.
For surface mounting.

1-11/16”
4-3/4” 5-21/32”
1-3/4” 3-3/8”
TOP

4-3/4”
2-19/32”

5-3/16”

MAXIMUM NUMBER OF CONDUCTORS


MAXIMUM NUMBER OF CONDUCTORS
AWG #18 AWG #16 AWG #14 AWG #12
AWG #18 AWG #16 AWG #14 AWG #12
8 8 8 8
4 4 4 4

-3-
ORDERING INFORMATION

Model
Part Number Application Description Designation
Number

IOB-R 75-000000-001 MT, MT-WP, RSSWP Indoor/Outdoor Surface Backbox H

ISP-R 75-000000-002 ET, ET70, MT Indoor Surface Plate B


Retrofit Plate (for use with installed
RP-R 75-000000-003 RSS, RSSP, 43T, MB, E70, ET70, MT, NS J
FSB1Box)
SBB-R 75-000000-004 RSS, RSSP, 43T, MB, E70, E90, ET70, MT, NS Surface Backbox D

SFP-R 75-000000-005 RSS, RSSP, 43T, MB, E70, ET70, MT NS Semi-Flush Plate F

BB-R 75-000000-006 RSS, RSSP, 43T, MB, NS Standard Indoor Backbox C

AP-R 75-000000-007 43T, MB Concealed Conduit Plate G

WBB-R 75-000000-008 43T, MB, RSSWP, MTWP, MT12/24 Weatherproof Backbox E

DBB-R 75-000000-009 RSS, RSSP, 43T, MB, MT, NS Deep Indoor Backbox A

SBL2-R 75-000000-012 RSS, RSSP, 43T, MB Surface Backbox N

SHBB-R 75-000000-013 RSS, RSSP, 43T, MB, NS Surface Backbox M

WPSBB 75-000000-014 RSSWP Weatherproof Backbox R

Fenwal is a registered trademark of Kidde-Fenwal, Inc.


TM
R

This literature is provided for informational purposes only. KIDDE-FENWAL, INC.


assumes no responsibility for the product’s suitability for a particular application. The
product must be properly applied to work correctly. Protection Systems
If you need more information on this product, or if you have a particular problem or ques-
tion, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000.
A UTC Fire & Security Company
400 Main Street
Ashland, MA 01721
Ph: 508.881.2000
F-75-008.A Rev AB © 2007 Kidde-Fenwal Inc. Printed in USA Fax: 508.881.8920
www.fenwalfire.com

You might also like