011 Kienke
011 Kienke
Site Information Tower Information Sub-contractor (SBC) Information Tower plate PHOTO
Subcontractor
IHS Site ID 011 Tower height (m) 54 m GRATO TELECOM
(SBC) name
Type of tower SBC Supervisor
KIENKE SS BIENVENUE MAYO MAYO
Site name (SS/RTP/RTT/Guyed/GRD/Monopole) name
Tower configuration (Angular, Tubular, SBC Supervisor
SUD ANGULAR 695 08 82 53
Region Hybrid) contact details
KRIBI 4 Date of inspection 6/14/2023
City No. of tower legs (1/2/3/4)
Site Latitude (in 2° 51' 21.4158" CARTEL Arrival time on site 14h54
degrees) Tower Manufacturer
Site Longitude 9° 58' 19.617" Departure time of
16h54
(in degrees) Tower design capacity (m2) site
Site Latitude (in 2.855949
decimal) Building height (m) [In case of Roof top]
Ticket Access (IHS NOC)
Site Longitude 9.972116 Number
(in decimal) Tower Installation date
1 SITE DATA Length (m) Width (m) Remarks PHOTO (if Not OK)
2 CIVIL WORKS VERIFICATION ON ALL TOWER TYPES OK / Not OK Remarks PHOTO (if Not OK)
2.1 Check site general condition (standing water, drainage, trees, etc) NOT OK STANDING WATER
2.2 Check for any foundation settlement / movements of tower & guy OK
Check the grout condition between the base plate and reinforced concrete
2.4 OK
column
Visual check of the tower / guy tower / anchor block foundation for cracks,
2.5 OK
honeycomb or abnormal changes
Visual check of the equipment concrete slab for cracks, honeycomb or
2.6 OK
abnormal changes
Visual check of the Genset and fuel tank concrete slab for cracks,
2.7 OK
honeycomb or abnormal changes
Check whether the anchor slabs rest on the supporting walls or vertical
2.8 /
columns (pillars) of a Roof-top site
Visual check of all the anchor concrete slabs for cracks, honeycomb or
2.9 /
abnormal changes for a Roof-top site
Condition of the building / roof slab on which the Roof-top tower / Roof-top
2.10 /
guyed tower / Roof-top pole is erected
ALL TOWERS (Monopoles, Self-support & Roof tops)
3 OK / Not OK Remarks PHOTO (if Not OK)
VERIFICATION POINTS
3.2 Check for any missing, loose, rusted or damaged members on the tower OK
3.3 Check for any visible cracks in welded connections (Flange & base plate) OK
Check for draining holes on pipe leg members and ensure that they are not
3.4 OK
blocked by clearing the blockages
4.1 Visual check of the working / rest platform for rust, fixation OK
5 GUYED TOWERS - GREENFIELD OR ROOFTOP OK / Not OK Remarks PHOTO (if Not OK)
Check visually the status of all the guyed wires for corrosion, breaks, nicks
5.1
and kinks
5.2
Check whether the wire tightening system is properly greased
5.3
Check for loose / missing guy wire clips & fasteners
5.4 Check and note guyed wire tension and sag before & after maintenance
5.5 Check the condition of fixation between the anchor & guy wire
Check the positioning of the wire rope clips on each guyed mast wire (as CORRECT WAY
5.10
shown in picture at the end ==>>)
INCORRECT WAY
Check visually wire thimble for rust, wear, bending, distortion and fractures,
5.11
safety screw, and its correct installation
5.12 Check the connection of the wire cables to earth at anchor points
6.1 Check antenna supports for rust, missing bolts & nuts, deformation OK
Check the grounding of the tower for rust, bad connection, missing bolts &
7.3 OK
nuts, protection by denzo or paste
Check installtion and state of the franklin lighning rod at the top of the
7.4 OK
tower or pole
Check the tightening of the brass bolts of the lightening protection
7.5 OK
electrodes
Check installation and connection of lightining cable or tape between the
7.6 OK
lightning rod and the earthing pit
All grounding above mentioned are not painted and are protected by Denzo NO DENZO / PASTE, BASE PLATE NOT
7.12 NOT OK
or paste GROUNDING
8 AIRCRAFT WARNING LIGHTS & CONTROL SYSTEMS OK / Not OK Remarks PHOTO (if Not OK)
8.4 Check the functionality of controllers, flashers, alarms and photo control OK
Check that the conduit, junction boxes & fasteners are weather tight and
8.7 OK
secure
Verify bulb condition - Change all the bulbs at the same time immediately
8.8 NOT OK 03 FLORESCENT LIGHT 1m HS
before the rated service hours is achieved
8.9 Check the condition & fidelity of the power supply systems OK
9 OUTDOOR AND ROOFTOP CANOPIES OK / Not OK Remarks PHOTO (if Not OK)
9.1 Check canopy ground fixation for rust, missing bolts, paint, etc. /
9.3 Check lighting and service power outlets for cracks & good condition NOT OK 01 PROJECTOR HS
11.1 Check the condition of the tower paint NOT OK TOWER NEED PAINDING
12.7 01 PROJECTOR HS
2 CIVIL WORKS VERIFICATION ON ALL TOWER TYPES. OK / Not OK Remarks PHOTO (if Not OK)
2.1 Check site general condition (standing water, drainage, trees, etc)
2.2 Check for any foundation settlement / movements of tower & guy
5 GUYED MAST VERIFICATION GREENFIELD OR ROOFTOP OK / Not OK Remarks PHOTO (if Not OK)
Check visually the status of all the guyed wires for corrosion, breaks,
5.1
nicks and kinks
5.2
Check whether the wire tightening system is properly greased
5.3
Check for loose / missing guy wire clips & fasteners
5.4 Check and note guyed wire tension and sag before & after maintenance
5.5 Check the condition of fixation between the anchor & guy wire
5.6 Visual check of the status of Preforms on all guyed wires
Visual check of anchor screw shakle for rust, wear, bending, distortion
5.7
and fractures and make sure it is well greased
Check the spacing between the guy wire clips (usually to be 6-7 times
5.8
the wire diameter) and the number of guy wire clips (indicate them)
Check visually wire rope clips for rust, wear, bending, distortion and
5.9
fractures, safety screw
CORRECT WAY
Check the positioning of the wire rope clips on each guyed mast wire
5.10
(as shown in picture at the end ==>>)
INCORRECT WAY
Check visually wire thimble for rust, wear, bending, distortion and
5.11
fractures, safety screw, and its correct installation
5.12 Check the connection of the wire cables to earth at anchor points
6.1 Check antenna supports for rust, missing bolts & nuts, deformation
Check the grounding of the tower for rust, bad connection, missing bolts
7.3
& nuts, protection by denzo or paste
Check installtion and state of the franklin lighning rod at the top of the
7.4
tower or pole
Check the tightening of the brass bolts of the lightening protection
7.5
electrodes
Check installation and connection of lightining cable or tape between
7.6
the lightning rod and the earthing pit
7.7 Check ground connection of the ladder to the grounding of the tower
8 AIRCRAFT WARNING LIGHTS & CONTROL SYSTEMS OK / Not OK Remarks PHOTO (if Not OK)
8.4 Check the functionality of controllers, flashers, alarms and photo control
8.9 Check the condition & fidelity of the power supply systems
9 OUTDOOR AND ROOFTOP CANOPIES OK / Not OK Remarks PHOTO (if Not OK)
9.1 Check canopy ground fixation for rust, missing bolts, paint, etc.
9.3 Check lighting and service power outlets for cracks & good condition
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8
GUYED TOWERS -TENSIONS BEFORE & AFTER MAINTENANCE
BC AD AB AC
1 06 GSM
2 04 MW
3
4
5
6
7
8
9
10
11
12
13
14
BILL OF QUANTITY - REFURBISHMENT
Supply Cost
1 Description Item Unit QTY. Service cost (UNIT)
(UNIT)
Supply Cost
2 Others Description Unit QTY. Service cost (UNIT)
(UNIT)
2.1
TOTAL
Total Cost
(UNIT)
Total Cost
(UNIT)
Sl. No SURVEY PICTURES
cable thimble
Turnbuckle
Thimble
Cosse-coeur
Guy wire rope
clip
SECURING TURNBUCKLES ON
ANCHOR WIRES