Iii 1 83 244

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

HSBCT

Code Interpretations

Choose the scope of the list of Code Interpretations you wish to see:

Status: Currently Valid


Status Description:

Interpretation: III-1-83-244
Subject: Section III, Division 1, NB-2360 Calibration of Instruments and
Equipment (1983 Edition With Winter 1983 Addenda)
Date Issued: July 25, 1984
File Number: NI84-031
Related Documents:

Question: Is recalibration of Charpy impact testing equipment required when parts of the
equipment are changed?

Reply: Yes.

The above interpretation was transcribed by HSB Code Services from the official publications [ASME published
volumes, National Board, Eurodyne]. Although every effort was made to accurately reproduce this interpretation, use of
this information should be for research only. It is strongly recommended that the official published document be used
for Code business.

User Profile | Terms of Use | Privacy

Copyright 2002. All Rights Reserved.


HSB Global Standards

http://www.hsbglobalstandards.com/hsbct/public.nsf2005/11/21 20:57:01