REMOTE POWER PANEL

WAVESTAR RPP SERIES

For More Information


Use your QR Reader
®
CHOICES TO MAXIMIZE
YOUR SYSTEM

Win the Race for Space & Power The drive for Simplified Expansion with Customized Options
more power in less space at the server cabinet • Reduces the length of cable runs between
level continues. PDI’s RPP complements this your PDU and the individual loads
change by offering the most options available • Optimizes usable floor space
in this free-standing 2' x 2' distribution or • Simplifies server consolidation plans
server-sized enclosures. PDI has the most • Meets the growth demands of dual cord
comprehensive line up of RPPs in the data equipment
center business. Although your PDUs may • Retrofits to any existing distribution system
still be able to handle the power demands of • Minimizes your investment risk today
your growing facility, they may not have room by allowing for incremental expansion of
for expansion. PDI’s Remote Power Panel your future facility
(RPP) helps you win “the race for space and • Unobstructed wiring access for ease of
power” by providing the added pole “space” installation
in a variety of “power” set ups to meet your
distribution needs in a small footprint. Flexible Packaging Designed in an aesthetically
pleasing cabinet to match the high-tech look
Our RPPs allow you to effectively use all of of today’s computer centers, the RPP’s flexible
your existing capacity before investing in configuration options allow it to grow with your
additional distribution. The RPP can pack in facility. The RPP can function as a stand alone
dual feeds, up to 168 breakers, and Branch device or as part of an extensive distribution
Circuit Monitoring with local monitoring in system. You can choose a single input device or
the 2' x 2' floor tile. The RPP is fed by any dual power feeds to satisfy system redundancy
standard subfeed circuit breaker of a PDU and maintenance requirements. All RPP designs
or 208V distribution board. PDI also offers can be packaged to allow for system expansion
the choice of Mission Critical Dual Source without interruption to your loads. Each unit
RPP – 225 or 400 amp modular rack mount can be equipped with any custom monitoring
unit to fit any 19" cabinet, the server line package you require for your system.
rack RPP in either 208V or new 480 V, and
the server line RPP from 15-150 kVA with a Assured Performance PDI’s complete line of
custom transformer. PowerPak technology has long delivered superior
performance and protection for your computer
Intelligent Monitoring Add a WaveStar monitor
® systems and equipment. With the options now
to see down to the branch circuit level on all available for PDI RPP's, you can match your
panel boards and increase your . The 15-300 kVA PowerPak and 225-750 kVA
system increases the visibility of the PowerHub™ power distribution units with the
actual loads on the raised floor which gives the best solution for your data center. The expanded
data center manager a better decision-making RPP line allows for flexible expansion of your
tool that covers system-wide performance, computer room and reflects PDI’s many years
individual output breakers power levels, and of experience in the power quality and
branch circuit monitoring (current and voltage). distribution industry.
(Power Distribution Intelligence Quotient)
gives you the ability to make better decisions PDI Service and Support After your equipment
based upon real time reporting of load / has been installed, call on the PDI service
capacity data. By adding the WaveStar® monitor team for 24/7 support. Our industry best
to your RPP, you can view linked devices and sales and service team will stay with you
keep better control of the data center floor loads. from the design of your system through the
life of your data center.
1 RPP 2 RPP 3 RPP 4 RPP 5 RPP/PDU
225 & 400 AMP SYSTEM MISSION CRITICAL MODULAR RACK MOUNT SERVERLINE PROFILE WITH TRANSFORMER, 15-150 KVA
225 & 400 AMP SYSTEM 225 & 400 AMP SYSTEM 225 & 400 AMP SYSTEM 225 & 400 AMP SYSTEM

2X2 2X2 MODULAR SYSTEM CABINET DEPTH RPP/PDU


FITS YOUR DATA CENTER WITH KIRK KEY
TM
FOR SERVER-RPP ALIGNS WITH YOUR TWO FUNCTIONS IN
INTERLOCKS “PLUG AND PLAY” SERVER SYSTEM ONE CABINET

1 RPP 2 RPP MISSION CRITICAL


PowerPak RPP Series standard features Mission Critical RPP standard features
• 2' x 2' footprint cabinet • 2' x 2' footprint cabinet
• Freestanding enclosure • Enhanced RPP security
• Removable top, side and rear panels • Designed to provide an alternate
• Full front inner hinged panelboard cover feed to loads
• 208/120 vAC - 60 Hz or 50 Hz available • MLO (main lugs only)
• 3 pole, 225A, 240V plug-in molded case panelboards
main input switch • 400 amp system also available
• Panelboard vision panels • (2) 225A Square D mission critical
• 400 amp system also available circuit breakers
• Square D or GE 42 pole distribution • Kirk™ key interlocks
panelboard • Solenoid key release
• Listed to UL standards • Sync check relay
• Oversized neutral for non-linear loads • Can be switched between two
• Single point grounding sources in a make-before-break
• Configurable for top or bottom entry configuration without
• Compression connections on all interrupting the load
panelboards • Isolated ground and equipment
• Hinged side and rear panels ground
• Flush-mounted door handle with integral • Switching neutral contactor for
keyed locks separately derived loads
• Increased wiring space • Neutral is rated at 400A with an
• “Door-in-door” handle on dead front option for 800A
CUSTOM SELECT YOUR NEXT RPP SYSTEM
3 RPP MODULAR RACK MOUNT SYSTEM Intelligent Monitors with
USES ANY 19" CABINETS THAT YOU ALREADY HAVE IN YOUR DATA CENTER AND provide real time load management data
YOU CAN INSTALL THIS MODULAR Section A resulting in better data center
capacity utilization
SYSTEM YOURSELF!
• System Level Monitoring
(per input feed)
• Output Circuit Breaker Monitoring
Protect Your Computers The Flexible Modular Design • Branch Circuit Monitoring –
data center has moved from Three basic modules: Current and Voltage available
a static environment to a • Input switch/BCMS-ready
highly dynamic one. 42-pole panelboard
Distribution panels on main • BCMS with built-in local
Output Circuit Monitoring
• Monitors individual output circuit
PDUs are at capacity and display
breakers power levels (optional)
running out of breaker space • WaveStar® system with five-
• Greatly improves reliability by
is common. IT professionals do receptacle module(s)
not have the time to wait for a Section B alerting operators before main cir-
cuit breakers exceed the trip level
certified electrician to install, MRD Distribution System: Section A
test and start new PDUs or • 3-phase 225A main input
add distribution to the row breaker with integrated CT
of racks. PDI’s Modular Rack Section C strips for branch circuit
Distribution solves these monitoring
problems while meeting the • Full front inner hinged front
growing demands of dynamic cover, steel housing with
data centers and IT profes- cable pass-throughs and
sionals. Installation can be “knock-outs”
performed by a customer,
electrical contractor or a PDI BCMS Module: Section B WaveStar Monitor
®

factory trained service techni- • Complete branch circuit


• Graphics display which captures
cian. It is truly your choice. monitoring with data
PDU and BCMS functions for
acquisition board and local
precise load management
Modular Rack Distribution WaveStar® display
features unobstructed wiring • Ribbon cable
Control your power destiny – put
access for ease of installation interconnection kit included
this in yourself!
and “plug-and-play” receptacle
modules for use with flex-
server Receptacle Module: Section C
ible overhead power WHIPs. server • 5-receptacle module
Each module is designed to server configuration (3U)
be installed in a standard server • L5-20 & 30
19" wide rack/enclosure. server • L6-20 & 30
• L21-20 & 30

Whips
• Fully terminated SO cable
whips available in 10', 15',
20', and 25' lengths

front back
POWER DISTRIBUTION UNIT: WAVESTAR RPP SERIES
®

4 RPP SERVERLINE PROFILE 5 RPP/PDU WITH TRANSFORMER, 15-150 KVA


225 AMP/400 AMP AT 208V OR NEW 480V SYSTEM
PowerPak RPP Series standard features Rack Distribution System standard features
• Front only or front and rear in-line • Input 480 vAC
dual 42 pole panelboards with bolt • Output 208/120 vAC
on circuit breakers • Main input breaker
• Single or dual feed via easy to access • Two (2) Square D panelboards
copper bus bar inputs (column-width style)
• 225 A main circuit breaker per • 225A secondary main circuit
panelboard or per 2 panelboards breakers rated 22 kAIC
• 400 amp system also available • Listed to UL standards
• Hinged dead front doors with 1/4 • Six (6) compensation taps
turn captive hardware and quick (4FCBN, 2FCAN)
removal clip • k20 copper, 150°C Class H
• Lockable main door with easy view insulation transformer
of all circuits (acrylic or solid finish) • Hinged panelboard covers with
• Branch circuit monitoring available slide lock access
• Large system status display • Remote communication
• Top or bottom entry, ultra spacious interface in modbus RTU
conduit access area with 1/4 turn protocol
captive hardware • Advanced door catch assures
• Easy access solid copper 200% rated positive closure
bus bar neutral terminal block • Door locks
• Standard ground bus and optional • 200% neutral
isolated ground bus • BCMS
• Solid copper input bus bars • WaveStar® monitoring package including BCMS in single
• WaveStar® monitoring package including BCMS monitor available
in single monitor available • 15 - 150 kVA custom transformer enclosed in server line
cabinet

* NEW - INDUSTRY FIRST - 480 V SYSTEM AVAILABLE *

= Power Distribution Intelligence Quotient


Your Smart Monitoring Solution

Power Distribution, Inc. | 4200 Oakleys Court | Richmond, VA 23223


800.225.4838 | 804.737.1703 fax | web site: www.pdicorp.com

©2013 PDI