System Configuration Report


==================================================================

Creation Date: Sunday July 02 2023


Creation Time: 01:09:29 Eastern

Location and SIN


================
Site Name : --- Site Name not se
DOT Number : 000000A
Milepost Number : --- 0.0 ---

SIN : 7.620.100.100.16

==================================================================
-- VERSION REPORT
==================================================================

MCF Version
============
MCF Name : gcp3k-01-9
MCF Revision : 019
MCFCRC : DEA1C941

Software Information
=================

Slot1 : VLP2
MEF VERSION : UnKnown
MEF ID Number : UnKnown
MEF CRC : 0x0000
BOOTCODE ID Number : UnKnown
BOOTCODE CRC : 0x0000

Non-Vital Software Versions


------------------------------
Component : MEF
ID : 9VC93-A01
Revision : M
Version : 1.3
Build # : 8
Build Date : Jun 06 2022 15:06 EDT
Load Date : 06-06-2022

Component : UBOOT
ID : 9VD65A01
Revision : A
Build # : -
Build Date : Oct 1 2018 - 14:07:50

Component : Linux Kernel


ID : 9VC87A01
Revision : B
Version : 2.6.24
Build # : -
Build Date : Thu Feb 16 16:43:35 PST 2017
Component : DTB
ID : 9VC89A01
Revision : B
Build # : -
Build Date : -

Component : FPGA
ID : 9VD90_A01
Revision : C
Version :
Build # : -
Build Date : 2020-Jan-16 13:42

==================================================================
-- CONFIGURATION REPORT
==================================================================

Program
=================
--------------------------------------------------
Site Configuration
--------------------------------------------------
Site Name : --- Site Name not se
DOT Number : 000000A
Mile Post : --- 0.0 ---
Time Zone : Eastern (GMT-5:00)
ATCS - Railroad : 620
ATCS - Line : 100
ATCS - Group : 100
ATCS - Display Subnode : 1
ATCS - CPU Subnode : 16
ATCS - SEAR Subnode : 99
Units of Measure : Standard
EMP Address : gcp.100

--------------------------------------------------
GCP Programming
--------------------------------------------------

General Configuration
Number of Tracks = 2 (OCCN)
RIO Module Used = Yes (OCCN)
Number of DAXes = None (OCCN)
Adv Preempt Timer = 0 sec (OCCN)
OOS Control = Display (OCCN)
OOS Timeout = 1 hrs (Field)
External Evt Recorder = No (OCCN)

Trk 1: GCP Basic


Track 1 : GCP Frequency = Not Set (OCCN,TCN)
Track 1 : Unidirnl/Bidirnl = Bidirnl (OCCN,TCN)
Track 1 : GCP XMIT Level = Medium (Field,TCN)
Track 1 : Prediction/MS Mode = Pred (OCCN)
Track 1 : Approach Distance = 9999 ft (OCCN,TCN)
Track 1 : Island Used = Internal (OCCN)
Track 1 : Island Distance = 120 ft (Field,TCN)
Track 1 : Isl Frequency = Not Set (OCCN)
Track 1 : Isl Pickup Delay (2s +) = 0 sec (OCCN)

Trk 1: GCP Prime


Track 1 : Prime Warning Time = 25 sec (OCCN)
Track 1 : Prime Prediction Offset = 0 ft (OCCN)
Track 1 : Prime Pickup Delay = 15 sec (OCCN)
Track 1 : UAX Pickup Delay = 0 sec (OCCN)

Trk 1: GCP Advanced


Track 1 : Enhanced Detection = On (High) (OCCN*)
Track 1 : Speed Limiting Used = Yes (Field)
Track 1 : Station Stop Timer = 20 sec (Field)
Track 1 : Trailing Switch Logic = On (Field)
Track 1 : Low EZ Detection (EZ=70) = Off (OCCN)
Track 1 : Positive Start EZ Level = 0 (OCCN*)
Track 1 : Sudden Shnt Detn Level = 0 (OCCN*)

Trk 2: GCP Basic


Track 2 : GCP Frequency = Not Set (OCCN,TCN)
Track 2 : Unidirnl/Bidirnl = Bidirnl (OCCN,TCN)
Track 2 : GCP XMIT Level = Medium (Field,TCN)
Track 2 : Prediction/MS Mode = Pred (OCCN)
Track 2 : Approach Distance = 9999 ft (OCCN,TCN)
Track 2 : Island Used = Internal (OCCN)
Track 2 : Island Distance = 120 ft (Field,TCN)
Track 2 : Isl Frequency = Not Set (OCCN)
Track 2 : Isl Pickup Delay (2s +) = 0 sec (OCCN)

Trk 2: GCP Prime


Track 2 : Prime Warning Time = 25 sec (OCCN)
Track 2 : Prime Prediction Offset = 0 ft (OCCN)
Track 2 : Prime Pickup Delay = 15 sec (OCCN)
Track 2 : UAX Pickup Delay = 0 sec (OCCN)

Trk 2: GCP Advanced


Track 2 : Enhanced Detection = On (High) (OCCN*)
Track 2 : Speed Limiting Used = Yes (Field)
Track 2 : Station Stop Timer = 20 sec (Field)
Track 2 : Trailing Switch Logic = On (Field)
Track 2 : Low EZ Detection (EZ=70) = Off (OCCN)
Track 2 : Positive Start EZ Level = 0 (OCCN*)
Track 2 : Sudden Shnt Detn Level = 0 (OCCN*)

Trk 1: MS Control/Transfer
Track 1 : MS Sensitivity Level = Normal (Field)
Track 1 : Switch MS EZ Level = 10 (OCCN)
Track 1 : Xfer Delay MS to GCP = 0 min (OCCN)

Trk 2: MS Control/Transfer
Track 2 : MS Sensitivity Level = Normal (Field)
Track 2 : Switch MS EZ Level = 10 (OCCN)
Track 2 : Xfer Delay MS to GCP = 0 min (OCCN)

Track Maintenance
Track 1 : T1 Low EX Adjustment = 0 (Field)
Track 2 : T2 Low EX Adjustment = 0 (Field)
Track 1 : T1 Compensation Value = 1300 (Field,TCN)
Track 2 : T2 Compensation Value = 1300 (Field,TCN)
Calibration Parameters
Track 1 : Computed Distance = 9999 ft (Field,TCN)
Track 1 : Linearization Steps = 100 (Field,TCN)
Track 2 : Computed Distance = 9999 ft (Field,TCN)
Track 2 : Linearization Steps = 100 (Field,TCN)

Display Settings
=======================
DHCP Configuration : Disabled
IP Address :
Security Enabled : None
Session Inactivity Timeout : 20 Minutes

Display Programming - Digi Intf Settings


--------------------------------------------------
Digitalization Interface Enabled : No
Encryption Enabled : Yes
Class D Connection : Connection 1
Encryption Password : Siemens1
Health Period : 1 Minutes
Alarm Retry Interval : 30 Seconds

Display Programming - Log Transfer Times


--------------------------------------------------
Transfer Time 1 (HH:MM) : 00:00
Transfer Time 2 (HH:MM) :
Transfer Time 3 (HH:MM) :
Transfer Time 4 (HH:MM) :

Display Programming - Class D Settings


--------------------------------------------------

Connection 1:
Application Gateway IP Address : 10.255.255.210
Application Gateway Port : 3001
Keep Alive Interval : 30000 ms
Keep Alive Ack Timeout : 30000 ms
NAK Retry Count : 3 ms
Retransmit Delay : 0 ms
Connect Attempt Timeout : 30000 ms
Connect Attempt Delay : 60000 ms
Connect Attempt Retry Count : -1 ms
Reconn. Attempt Retry Limit : -1 ms
Data ACK Enable : Yes
Data ACK Timeout : 15000 ms

Connection 2:
Application Gateway IP Addr : 10.255.255.210
Application Gateway Port : 3001
Keep Alive Interval : 30000 ms
Keep Alive Ack Timeout : 30000 ms
NAK Retry Count : 3 ms
Retransmit Delay : 0 ms
Connect Attempt Timeout : 30000 ms
Connect Attempt Delay : 60000 ms
Connect Attempt Retry Count : -1 ms
Reconn. Attempt Retry Limit : -1 ms
Data ACK Enable : Yes
Data ACK Timeout : 15000 ms

Display Programming - EMP Settings


--------------------------------------------------
Mind Connect Rail EMP Address : siemens.mcr.o.100
EMP TTL : 0
EMP QOS : 0
Message Authentication Key : Safetran1

Track Monitoring - Configuration


--------------------------------------------------
Track 1 : Disabled
Track 2 : Disabled
Pre-Trigger Samples : 60
Post-Trigger Samples : 60
Max Storage (MBytes) : 64
Interval : 30 Minutes
Duration : 10 Seconds

==================================================================
Minimum Program Steps
==================================================================

Vital Configuration Changes


---------------------------
No Changes to report, parameters are all default
* Parameter is part of office configuration check number calculation

Check Numbers:
Office Check Number: 25BCE025
Config. Check Number: 1094DE9A

TCN :
Main (powered) Standby(unpowered)
Field Check Number(FCN): 0 0
TCN Track 1: 0 0
TCN Track 2: 0 0

Non-Vital Configuration Changes


-------------------------------

Display Settings:
DHCP Configuration : Disabled
IP Address :

Track Monitoring - Configuration


--------------------------------------------------
Duration : 10 Seconds

=======================
Admin Only Settings
=======================

Display Programming - Digi Intf Settings


--------------------------------------------------
Digitalization Interface Enabled : No
Encryption Enabled : Yes
Class D Connection : Connection 1
Encryption Password : Siemens1
Health Period : 1 Minutes
Alarm Retry Interval : 30 Seconds

Display Programming - Log Transfer Times


--------------------------------------------------
Transfer Time 1 (HH:MM) : 00:00
Transfer Time 2 (HH:MM) :
Transfer Time 3 (HH:MM) :
Transfer Time 4 (HH:MM) :

Display Programming - Class D Settings


--------------------------------------------------

Connection 1:
Application Gateway IP Address : 10.255.255.210
Application Gateway Port : 3001
Keep Alive Interval : 30000 ms
Keep Alive Ack Timeout : 30000 ms
NAK Retry Count : 3 ms
Retransmit Delay : 0 ms
Connect Attempt Timeout : 30000 ms
Connect Attempt Delay : 60000 ms
Connect Attempt Retry Count : -1 ms
Reconn. Attempt Retry Limit : -1 ms
Data ACK Enable : Yes
Data ACK Timeout : 15000 ms

Connection 2:
Application Gateway IP Addr : 10.255.255.210
Application Gateway Port : 3001
Keep Alive Interval : 30000 ms
Keep Alive Ack Timeout : 30000 ms
NAK Retry Count : 3 ms
Retransmit Delay : 0 ms
Connect Attempt Timeout : 30000 ms
Connect Attempt Delay : 60000 ms
Connect Attempt Retry Count : -1 ms
Reconn. Attempt Retry Limit : -1 ms
Data ACK Enable : Yes
Data ACK Timeout : 15000 ms

Display Programming - EMP Settings


--------------------------------------------------
Mind Connect Rail EMP Address : siemens.mcr.o.100
EMP TTL : 0
EMP QOS : 0
Message Authentication Key : Safetran1

CP Programming - Ethernet Ports


--------------------------------------------------
Laptop Ethernet Port:
DHCP Configuration : Disabled
IP Address :
Network Mask :
Default Gateway :
Ethernet Port 3:
DHCP Configuration : Disabled
IP Address : 192.168.2.100
Network Mask : 255.255.255.0
Default Gateway :
Path Type : None
Protocol : None

CP Programming - Diagnostic Logging


--------------------------------------------------
Message Processing (Layer 7) : Disabled
Routing (Layer 3) : Disabled
Serial Port 1 RX/TX (Layer 2) : Disabled
EZ/EX Logging : Change
EZ/EX Point Change : 3
EZ/EX Logging Interval : 4 Seconds
EZ/EX Recording : Enabled
Ethernet Laptop Port RX/TX (Layer 2) : Disabled
Ethernet Port 1 RX/TX (Layer 2) : Disabled
Ethernet Port 2 RX/TX (Layer 2) : Disabled
Echelon RX/TX : Disabled
CPU RX/TX : Disabled
Digi Protocol Logging Enabled : Disabled

CP Programming - Log Verbosity Settings


--------------------------------------------------
CP Diagnostic Log Verbosity : Info
VLP Log Verbosity : 1
Slot 2 Log Verbosity : 1
Slot 3 Log Verbosity : 1
Slot 4 Log Verbosity : 1

DTC Interface - Configuration


--------------------------------------------------
IP Address : 192.100.100.1
Port Number : 11000
Secondary Address Enabled : Disabled

ATCS Route - Configuration


--------------------------------------------------
Route Table Entry Timeout : 400
ATCS IP FIELD UDP Port Number : 13000
ATCS IP FIELD Interface : Echelon

Track Monitoring - Configuration


--------------------------------------------------
Track 1 : Disabled
Track 2 : Disabled
Pre-Trigger Samples : 60
Post-Trigger Samples : 60
Max Storage (MBytes) : 64
Interval : 30 Minutes
Duration : 10 Seconds

CP Programming - Security
--------------------------------------------------
Security Enabled : None
Session Inactivity Timeout : 20 Minutes
CP Programming - Web Server Access
--------------------------------------------------
Browser Access : Secure (https)