System Configuration Report

Creation Date: Thursday September 07 2023


Creation Time: 14:37:54 Eastern

Location and SIN


================
Site Name : test1_0709
DOT Number : 000000A
Milepost Number : 000.0

SIN : 7.620.100.100.16

MCF Version
============
MCF Name : gcp5k-02-3.mcf
MCF Revision : 023
MCFCRC : 0EA1F809

Minimum Program Steps


=================
No Changes to report, parameters are all default.
* Parameter is part of office configuration check number calculation

Check Numbers:
Office Configuration Check Number: 71187341
Config. Check Number: 1C64F545

Non Vital Configuration


-----------------------

Site Information
--------------------------------------------------
Site Name : test1_0709

SEAR Configuration
------------------

No Changes.

Template
=================

TEMPLATE: module configuration


Track 1 Slot = Track (OCCN)
Track 2/RIO 1 Slot = Track (OCCN)
Track 3 Slot = Track (OCCN)
Track 4 Slot = Not Used (OCCN)
Track 5/RIO 2 Slot = Not Used (OCCN)
Track 6/RIO 3 Slot = Not Used (OCCN)
SSCC 1 Slot = SSCC3i (OCCN)
SSCC 2 Slot = SSCC3i (OCCN)
SEAR Used = Yes (OCCN)
Chassis Type = Dual Six Track (OCCN)

TEMPLATE: preemption
Preempt Logic = No (OCCN)
Second Trn Logic Used = No (OCCN)

TEMPLATE: track 1-Bi, Island


Track 1 : GCP Frequency = Not Set (OCCN)
Track 1 : Approach Distance = 9999 ft (OCCN)
Track 1 : Prime Warning Time = 35 sec (OCCN)
Track 1 : Prime UAX = No (OCCN)
Track 1 : GCP Transmit Level = Medium (Field,TCN)
Track 1 : Isl Frequency = Not Set (OCCN)

TEMPLATE: track 2-Remote Prime


Track 2 : GCP Frequency = Not Set (OCCN)
Track 2 : Approach Distance = 9999 ft (OCCN)
Track 2 : Prime Warning Time = 35 sec (OCCN)
Track 2 : Prime Offset Distance = 99 ft (OCCN)
Track 2 : Prime UAX = No (OCCN)
Track 2 : GCP Transmit Level = Medium (Field,TCN)
Track 2 : Uni/Bi/Sim-Bidirnl = Unidirnl (OCCN)

TEMPLATE: track 2 Daxes


Track 2 : Dax A Used = No (OCCN)
Track 2 : Dax B Used = No (OCCN)
Track 2 : Dax C Used = No (OCCN)

TEMPLATE: track 3-Remote Prime


Track 3 : GCP Frequency = Not Set (OCCN)
Track 3 : Approach Distance = 9999 ft (OCCN)
Track 3 : Prime Warning Time = 35 sec (OCCN)
Track 3 : Prime Offset Distance = 99 ft (OCCN)
Track 3 : Prime UAX = No (OCCN)
Track 3 : GCP Transmit Level = Medium (Field,TCN)
Track 3 : Uni/Bi/Sim-Bidirnl = Unidirnl (OCCN)

TEMPLATE: track 3 Daxes


Track 3 : Dax A Used = No (OCCN)
Track 3 : Dax B Used = No (OCCN)
Track 3 : Dax C Used = No (OCCN)

TEMPLATE: track Anding


AND 1 XR Used = Yes (OCCN)
AND 2 Used = No (OCCN)
AND 3 Used = No (OCCN)
AND 4 Used = No (OCCN)

TEMPLATE: AND 1 XR
AND 1 XR Track 1 = Prime (OCCN)
AND 1 XR Track 2 = Prime (OCCN)
AND 1 XR Track 3 = Prime (OCCN)
AND 1 Enable Used = No (OCCN)

TEMPLATE: SSCC
Gates Used = Yes (OCCN)
SSCC1+2 GPs Coupled = Yes (OCCN)
SSCC-1 Number of GPs = 1 (OCCN)
SSCC-1 Number of GDs = 2 (OCCN)
SSCC-2 Number of GPs = 0 (OCCN)
SSCC-2 Number of GDs = 0 (OCCN)
SSCC 1 : SSCC-1 Lamp Neutral Test = Off (Field)
SSCC 2 : SSCC-2 Lamp Neutral Test = Off (Field)

TEMPLATE: OOS
OOS Control = Display (OCCN)
OOS Timeout = Yes (OCCN)
OOS Timeout = 1 hrs (Field)

TEMPLATE: OP assignment 1
OUT 1.1 = Not Used (OCCN)
OUT 1.2 = Not Used (OCCN)
OUT 2.1 = Not Used (OCCN)
OUT 2.2 = Not Used (OCCN)
OUT 3.1 = Not Used (OCCN)
OUT 3.2 = Not Used (OCCN)

TEMPLATE: IP assignment 1
IN 1.1 = Not Used (OCCN)
IN 1.2 = Not Used (OCCN)
IN 2.1 = Not Used (OCCN)
IN 2.2 = Not Used (OCCN)
IN 3.1 = Not Used (OCCN)
IN 3.2 = Not Used (OCCN)

TEMPLATE: IP assignment SSCC


IN 7.1 = Not Used (OCCN)
IN 7.2 = GD 1.2 (OCCN)
IN 7.3 = Not Used (OCCN)
IN 7.4 = GD 1.1 (OCCN)
IN 7.5 = GP 1.1 (OCCN)
IN 8.1 = Not Used (OCCN)
IN 8.2 = Not Used (OCCN)
IN 8.3 = Not Used (OCCN)
IN 8.4 = Not Used (OCCN)
IN 8.5 = Not Used (OCCN)

TEMPLATE: selection
Template = 2C:2 Bi, 4 Rem (OCCN)

Program
=================

(1.1) Set Template


Template = 2C:2 Bi, 4 Rem (OCCN)

(1.2) Module Selection


Track 1 Slot = Track (OCCN)
Track 2/RIO 1 Slot = Track (OCCN)
Track 3 Slot = Track (OCCN)
Track 4 Slot = Not Used (OCCN)
Track 5/RIO 2 Slot = Not Used (OCCN)
Track 6/RIO 3 Slot = Not Used (OCCN)
SSCC-1 Slot = SSCC3i (OCCN)
SSCC-2 Slot = SSCC3i (OCCN)
SEAR Used = Yes (OCCN)
Chassis Type = Dual Six Track (Field)

(1.3) Preemption
Preempt Logic = No (OCCN)
Second Trn Logic Used = No (OCCN)
(1.4) MS/Restart
MS/GCP Restart Used = No (OCCN)

(1.5) Vital Comms Links


Vital Comms link 1 Used = No (OCCN)
Vital Comms link 2 Used = No (OCCN)
Vital Comms link 3 Used = No (OCCN)
Vital Comms link 4 Used = No (OCCN)

(1.6) Out of Service


OOS Control = Display (OCCN)
OOS Timeout = Yes (OCCN)
OOS Timeout = 1 hrs (Field)

(2.1.1) Trk 1: GCP Frequency


Track 1 : MS/GCP Operation = Yes (OCCN)
Track 1 : GCP Freq Category = Standard (Field)
Track 1 : GCP Frequency = Not Set (OCCN,TCN)
Track 1 : GCP Transmit Level = Medium (Field,TCN)
Track 1 : Uni/Bi/Sim-Bidirnl = Bidirnl (OCCN,TCN)
Track 1 : Approach Distance = 9999 ft (OCCN,TCN)
Track 1 : Directionally Wired = No (OCCN)
Track 1 : Island Connection = Isl 1 (OCCN)
Track 1 : Computed Distance = 9999 ft (Field,TCN)
Track 1 : Linearization Steps = 100 (Field,TCN)

(2.1.2) Trk 1: Island Frequency


Track 1 : Island Used = Internal (OCCN)
Track 1 : Isl Frequency = Not Set (OCCN)
Track 1 : Pickup Delay (2s +) = 0 sec (OCCN)
Track 1 : Isl Enable IP Used = No (OCCN)
Track 1 : Island Distance = 120 ft (Field,TCN)

(2.1.3) Trk 1: Predictors


Track 1 : Prime Used = Yes (OCCN)
Track 1 : Dax A Used = No (OCCN)
Track 1 : Dax B Used = No (OCCN)
Track 1 : Dax C Used = No (OCCN)
Track 1 : Dax D Used = No (OCCN)
Track 1 : Dax E Used = No (OCCN)
Track 1 : Dax F Used = No (OCCN)
Track 1 : Dax G Used = No (OCCN)

(2.1.3.1) Trk 1 Predictor: Prime


Track 1 : Prime Used = Yes (OCCN)
Track 1 : Prime Warning Time = 35 sec (OCCN)
Track 1 : Prime Offset Distance = 0 ft (OCCN)
Track 1 : Switch MS EZ Level = 10 (OCCN)
Track 1 : Prime MS/GCP Mode = Pred (OCCN)
Track 1 : Prime Pickup Delay = 15 sec (OCCN)
Track 1 : Prime UAX = No (OCCN)

(2.1.4) Trk 1: Enhanced Detection


Track 1 : Inbound PS Sensitivity = High (Field)
Track 1 : Speed Limiting Used = Yes (Field)
Track 1 : Outbound False Act Lvl = Normal (Field)
Track 1 : Outbound PS Timer = 20 sec (Field)
Track 1 : Trailing Switch Logic = On (Field)
Track 1 : Post Joint Detn Time = 15 sec (OCCN)
Track 1 : Cancel Pickup Delay = This Isl (OCCN)
Track 1 : Adv Appr Predictn = No (OCCN)

(2.1.5) Trk 1: Positive Start, Low EZ


Track 1 : Positive Start = Off (OCCN)
Track 1 : Sudden Shnt Det Used = No (OCCN)
Track 1 : Low EZ Detection Used = No (OCCN)

(2.1.6) Trk 1: MS Control


Track 1 : MS/GCP Ctrl IP Used = No (OCCN)
Track 1 : MS Sensitivity Level = 0 (Field)
Track 1 : MS/GCP Restart EZ Level = 80 (Field)

(2.1.7) Trk 1: Wraps and Overrides


Track 1 : Wrap Used = No (OCCN)
Track 1 : All Predictors Override Used = No (OCCN)

(2.1.8) Trk 1: GCP Miscellaneous


Track 1 : Low EX Adjustment = 39 (Field)
Track 1 : False Act on Train Stop = No (Field)
Track 1 : EX Limiting Used = Yes (Field)
Track 1 : EZ Correction Used = Yes (Field)
Track 1 : Compensation Level = 1300 (Field,TCN)
Track 1 : Warn Time-Ballast Comp = High (Field,TCN)
Track 1 : Train Line Speed = 0 mph (OCCN)

(2.2.1) Trk 2: GCP Frequency


Track 2 : MS/GCP Operation = Yes (OCCN)
Track 2 : GCP Freq Category = Standard (Field)
Track 2 : GCP Frequency = Not Set (OCCN,TCN)
Track 2 : GCP Transmit Level = Medium (Field,TCN)
Track 2 : Uni/Bi/Sim-Bidirnl = Unidirnl (OCCN,TCN)
Track 2 : Approach Distance = 9999 ft (OCCN,TCN)
Track 2 : Directionally Wired = No (OCCN)
Track 2 : Island Connection = No Islands (OCCN)
Track 2 : Computed Distance = 9999 ft (Field,TCN)
Track 2 : Linearization Steps = 100 (Field,TCN)

(2.2.2) Trk 2: Island Frequency


Track 2 : Island Used = No (OCCN)
Track 2 : Island Distance = 0 ft (Field,TCN)

(2.2.3) Trk 2: Predictors


Track 2 : Prime Used = Yes (OCCN)
Track 2 : Dax A Used = No (OCCN)
Track 2 : Dax B Used = No (OCCN)
Track 2 : Dax C Used = No (OCCN)
Track 2 : Dax D Used = No (OCCN)
Track 2 : Dax E Used = No (OCCN)
Track 2 : Dax F Used = No (OCCN)
Track 2 : Dax G Used = No (OCCN)

(2.2.3.1) Trk 2 Predictor: Prime


Track 2 : Prime Used = Yes (OCCN)
Track 2 : Prime Warning Time = 35 sec (OCCN)
Track 2 : Prime Offset Distance = 99 ft (OCCN)
Track 2 : Switch MS EZ Level = 0 (OCCN)
Track 2 : Pickup Delay Mode = Auto (OCCN)
Track 2 : Prime MS/GCP Mode = Pred (OCCN)
Track 2 : Prime Pickup Delay = 15 sec (OCCN)
Track 2 : Prime UAX = No (OCCN)

(2.2.4) Trk 2: Enhanced Detection


Track 2 : Inbound PS Sensitivity = High (Field)
Track 2 : Speed Limiting Used = Yes (Field)
Track 2 : Outbound False Act Lvl = Normal (Field)
Track 2 : Outbound PS Timer = 20 sec (Field)
Track 2 : Trailing Switch Logic = On (Field)
Track 2 : Post Joint Detn Time = 15 sec (OCCN)
Track 2 : Cancel Pickup Delay = This Isl (OCCN)
Track 2 : Adv Appr Predictn = No (OCCN)

(2.2.5) Trk 2: Positive Start, Low EZ


Track 2 : Positive Start = Off (OCCN)
Track 2 : Sudden Shnt Det Used = No (OCCN)
Track 2 : Low EZ Detection Used = No (OCCN)

(2.2.6) Trk 2: MS Control


Track 2 : MS/GCP Ctrl IP Used = No (OCCN)
Track 2 : MS Sensitivity Level = 0 (Field)
Track 2 : MS/GCP Restart EZ Level = 80 (Field)

(2.2.7) Trk 2: Wraps and Overrides


Track 2 : Wrap Used = No (OCCN)
Track 2 : All Predictors Override Used = No (OCCN)

(2.2.8) Trk 2: GCP Miscellaneous


Track 2 : Low EX Adjustment = 39 (Field)
Track 2 : False Act on Train Stop = No (Field)
Track 2 : EX Limiting Used = Yes (Field)
Track 2 : EZ Correction Used = Yes (Field)
Track 2 : Compensation Level = 1300 (Field,TCN)
Track 2 : Warn Time-Ballast Comp = Low (Field,TCN)
Track 2 : Train Line Speed = 0 mph (OCCN)

(2.3.1) Trk 3: GCP Frequency


Track 3 : MS/GCP Operation = Yes (OCCN)
Track 3 : GCP Freq Category = Standard (Field)
Track 3 : GCP Frequency = Not Set (OCCN,TCN)
Track 3 : GCP Transmit Level = Medium (Field,TCN)
Track 3 : Uni/Bi/Sim-Bidirnl = Unidirnl (OCCN,TCN)
Track 3 : Approach Distance = 9999 ft (OCCN,TCN)
Track 3 : Directionally Wired = No (OCCN)
Track 3 : Island Connection = No Islands (OCCN)
Track 3 : Computed Distance = 9999 ft (Field,TCN)
Track 3 : Linearization Steps = 100 (Field,TCN)

(2.3.2) Trk 3: Island Frequency


Track 3 : Island Used = No (OCCN)
Track 3 : Island Distance = 0 ft (Field,TCN)

(2.3.3) Trk 3: Predictors


Track 3 : Prime Used = Yes (OCCN)
Track 3 : Dax A Used = No (OCCN)
Track 3 : Dax B Used = No (OCCN)
Track 3 : Dax C Used = No (OCCN)
Track 3 : Dax D Used = No (OCCN)
Track 3 : Dax E Used = No (OCCN)
Track 3 : Dax F Used = No (OCCN)
Track 3 : Dax G Used = No (OCCN)

(2.3.3.1) Trk 3 Predictor: Prime


Track 3 : Prime Used = Yes (OCCN)
Track 3 : Prime Warning Time = 35 sec (OCCN)
Track 3 : Prime Offset Distance = 99 ft (OCCN)
Track 3 : Switch MS EZ Level = 0 (OCCN)
Track 3 : Pickup Delay Mode = Auto (OCCN)
Track 3 : Prime MS/GCP Mode = Pred (OCCN)
Track 3 : Prime Pickup Delay = 15 sec (OCCN)
Track 3 : Prime UAX = No (OCCN)

(2.3.4) Trk 3: Enhanced Detection


Track 3 : Inbound PS Sensitivity = High (Field)
Track 3 : Speed Limiting Used = Yes (Field)
Track 3 : Outbound False Act Lvl = Normal (Field)
Track 3 : Outbound PS Timer = 20 sec (Field)
Track 3 : Trailing Switch Logic = On (Field)
Track 3 : Post Joint Detn Time = 15 sec (OCCN)
Track 3 : Cancel Pickup Delay = This Isl (OCCN)
Track 3 : Adv Appr Predictn = No (OCCN)

(2.3.5) Trk 3: Positive Start, Low EZ


Track 3 : Positive Start = Off (OCCN)
Track 3 : Sudden Shnt Det Used = No (OCCN)
Track 3 : Low EZ Detection Used = No (OCCN)

(2.3.6) Trk 3: MS Control


Track 3 : MS/GCP Ctrl IP Used = No (OCCN)
Track 3 : MS Sensitivity Level = 0 (Field)
Track 3 : MS/GCP Restart EZ Level = 80 (Field)

(2.3.7) Trk 3: Wraps and Overrides


Track 3 : Wrap Used = No (OCCN)
Track 3 : All Predictors Override Used = No (OCCN)

(2.3.8) Trk 3: GCP Miscellaneous


Track 3 : Low EX Adjustment = 39 (Field)
Track 3 : False Act on Train Stop = No (Field)
Track 3 : EX Limiting Used = Yes (Field)
Track 3 : EZ Correction Used = Yes (Field)
Track 3 : Compensation Level = 1300 (Field,TCN)
Track 3 : Warn Time-Ballast Comp = Low (Field,TCN)
Track 3 : Train Line Speed = 0 mph (OCCN)

(3.1) Logic: Track ANDing


AND 1 XR Used = Yes (OCCN)
AND 2 Used = No (OCCN)
AND 3 Used = No (OCCN)
AND 4 Used = No (OCCN)

(3.1.1) Logic: AND 1 XR


AND 1 XR Track 1 = Prime (OCCN)
AND 1 XR Track 2 = Prime (OCCN)
AND 1 XR Track 3 = Prime (OCCN)
AND 1 Wrap Used = No (OCCN)
AND 1 Enable Used = No (OCCN)
(3.2) Logic: AND Gates
AND 5 Used = No (OCCN)
AND 6 Used = No (OCCN)
AND 7 Used = No (OCCN)
AND 8 Used = No (OCCN)
AND 9 Used = No (OCCN)
AND 10 Used = No (OCCN)
AND 11 Used = No (OCCN)
AND 12 Used = No (OCCN)

(3.3) Logic: OR Gates


OR 1 Used = No (OCCN)
OR 2 Used = No (OCCN)
OR 3 Used = No (OCCN)
OR 4 Used = No (OCCN)

(3.4) Logic: Controls


Emergency Activate IP = No (OCCN)
Maint Call Rpt IP Used = No (OCCN)
Pass Thrus = No (OCCN)

(3.5.1) Internal I/O 1-4


Int.1 Sets = Not Used (OCCN)
Int.1 Set by = Not Used (OCCN)
Int.2 Sets = Not Used (OCCN)
Int.2 Set by = Not Used (OCCN)
Int.3 Sets = Not Used (OCCN)
Int.3 Set by = Not Used (OCCN)
Int.4 Sets = Not Used (OCCN)
Int.4 Set by = Not Used (OCCN)

(3.5.2) Internal I/O 5-8


Int.5 Sets = Not Used (OCCN)
Int.5 Set by = Not Used (OCCN)
Int.6 Sets = Not Used (OCCN)
Int.6 Set by = Not Used (OCCN)
Int.7 Sets = Not Used (OCCN)
Int.7 Set by = Not Used (OCCN)
Int.8 Sets = Not Used (OCCN)
Int.8 Set by = Not Used (OCCN)

(3.5.3) Internal I/O 9-12


Int.9 Sets = Not Used (OCCN)
Int.9 Set by = Not Used (OCCN)
Int.10 Sets = Not Used (OCCN)
Int.10 Set by = Not Used (OCCN)
Int.11 Sets = Not Used (OCCN)
Int.11 Set by = Not Used (OCCN)
Int.12 Sets = Not Used (OCCN)
Int.12 Set by = Not Used (OCCN)

(3.5.4) Internal I/O 13-16


Int.13 Sets = Not Used (OCCN)
Int.13 Set by = Not Used (OCCN)
Int.14 Sets = Not Used (OCCN)
Int.14 Set by = Not Used (OCCN)
Int.15 Sets = Not Used (OCCN)
Int.15 Set by = Not Used (OCCN)
Int.16 Sets = Not Used (OCCN)
Int.16 Set by = Not Used (OCCN)

(4.1) SSCC Configuration


Gates Used = Yes (OCCN)
SSCC1+2 GPs Coupled = Yes (OCCN)
Min Activation = 0 sec (OCCN)
Rmt Activation Cancel = 2 min (OCCN)
Bell On Gate Rising = No (OCCN)
Mute Bell On Gate Down = No (OCCN)
SSCCIV Controller Used = No (OCCN)

(4.3) SSCC 1 Configuration


SSCC-1 Activation = AND 1 XR (OCCN)
SSCC-1 Gate Delay = 4 sec (OCCN)
SSCC-1 Number of GPs = 1 (OCCN)
SSCC-1 Number of GDs = 2 (OCCN)

(4.3.1) SSCC 1 Extended Parameters


SSCC 1 : Flash Rate = 50 (OCCN)
SSCC 1 : Flash Sync = master (OCCN)
SSCC 1 : Invert Gate Output = No (OCCN)
SSCC 1 : Lamp Neutral Test = Off (Field)
SSCC 1 : Lamp 1 Voltage = 100 dV (Field)
SSCC 1 : Lamp 2 Voltage = 100 dV (Field)
Aux-1 Xng Ctrl Used = No (OCCN)

(4.4) SSCC 2 Configuration


SSCC-2 Activation = AND 1 XR (OCCN)
SSCC-2 Gate Delay = 4 sec (OCCN)
SSCC-2 Number of GPs = 0 (OCCN)
SSCC-2 Number of GDs = 0 (OCCN)

(4.4.1) SSCC 2 Extended Parameters


SSCC 2 : Flash Rate = 50 (OCCN)
SSCC 2 : Flash Sync = slave (OCCN)
SSCC 2 : Invert Gate Output = No (OCCN)
SSCC 2 : Lamp Neutral Test = Off (Field)
SSCC 2 : Lamp 1 Voltage = 100 dV (Field)
SSCC 2 : Lamp 2 Voltage = 100 dV (Field)
Aux-2 Xng Ctrl Used = No (OCCN)

(5.1.1) I/O: Output Slot 1-2


OUT 1.1 = Not Used (OCCN)
OUT 1.2 = Not Used (OCCN)
OUT 2.1 = Not Used (OCCN)
OUT 2.2 = Not Used (OCCN)

(5.1.2) I/O: Output Slot 3-4


OUT 3.1 = Not Used (OCCN)
OUT 3.2 = Not Used (OCCN)

(5.1.4) I/O: Output Slot SSCC


OUT GC 1 = Gate Output 1 (OCCN)
OUT GC 2 = Gate Output 2 (OCCN)

(5.2.1) I/O: Input Slot 1-2


IN 1.1 = Not Used (OCCN)
IN 1.2 = Not Used (OCCN)
IN 2.1 = Not Used (OCCN)
IN 2.2 = Not Used (OCCN)

(5.2.2) I/O: Input Slot 3-4


IN 3.1 = Not Used (OCCN)
IN 3.2 = Not Used (OCCN)

(5.2.4) I/O: Input Slot SSCC 1


IN 7.1 = Not Used (OCCN)
IN 7.2 = GD 1.2 (OCCN)
IN 7.3 = Not Used (OCCN)
IN 7.4 = GD 1.1 (OCCN)
IN 7.5 = GP 1.1 (OCCN)

(5.2.5) I/O: Input Slot SSCC 2


IN 8.1 = Not Used (OCCN)
IN 8.2 = Not Used (OCCN)
IN 8.3 = Not Used (OCCN)
IN 8.4 = Not Used (OCCN)
IN 8.5 = Not Used (OCCN)

Non Vital Configuration


=======================

Site Information
--------------------------------------------------
Site Name : test1_0709
DOT Number : 000000A
Mile Post : 000.0
Time Zone : Eastern (GMT-5:00)
ATCS - Railroad : 620
ATCS - Line : 100
ATCS - Group : 100
ATCS - Display Subnode : 1
ATCS - CPU Subnode : 16
ATCS - SEAR Subnode : 99
SEAR Temp. Format : Fahrenheit
SEAR Date Format : American (mm-dd-yyyy)
Units of Measure : Standard
EMP Address : gcp.100

Display Programming - Digi Intf Settings


--------------------------------------------------
Digitalization Interface Enabled : No
Encryption Enabled : Yes
Class D Connection : Connection 1
Encryption Password : Siemens1
Health Period : 1 Minutes
Alarm Retry Interval : 30 Seconds

Display Programming - Log Transfer Times


--------------------------------------------------
Transfer Time 1 (HH:MM) : 00:00
Transfer Time 2 (HH:MM) :
Transfer Time 3 (HH:MM) :
Transfer Time 4 (HH:MM) :

Display Programming - Class D Settings


--------------------------------------------------

Connection 1:
Application Gateway IP Address : 10.255.255.210
Application Gateway Port : 3001
Keep Alive Interval : 30000 ms
Keep Alive Ack Timeout : 30000 ms
NAK Retry Count : 3
Retransmit Delay : 0 ms
Connect Attempt Timeout : 30000 ms
Connect Attempt Delay : 60000 ms
Connect Attempt Retry Count : -1
Reconn. Attempt Retry Limit : -1
Data ACK Enable : Yes
Data ACK Timeout : 15000 ms

Connection 2:
Application Gateway IP Addr : 10.255.255.210
Application Gateway Port : 3001
Keep Alive Interval : 30000 ms
Keep Alive Ack Timeout : 30000 ms
NAK Retry Count : 3
Retransmit Delay : 0 ms
Connect Attempt Timeout : 30000 ms
Connect Attempt Delay : 60000 ms
Connect Attempt Retry Count : -1
Reconn. Attempt Retry Limit : -1
Data ACK Enable : Yes
Data ACK Timeout : 15000 ms

Display Programming - EMP Settings


--------------------------------------------------
Mind Connect Rail EMP Address : siemens.mcr.o.100
EMP TTL : 0
EMP QOS : 0
Message Authentication Key : Safetran1

Display Programming - Serial Ports


--------------------------------------------------
Serial Port 1:
Baud Rate : 9600
Data Bits : 8
Parity : None
Stop Bits : 1
Flow Ctrl : None
Path Type : None
Protocol : None

Display Programming - DNS Servers


--------------------------------------------------
Name Server 1 : 192.168.2.1
Name Server 2 : 192.168.3.1
Name Server 3 : 192.168.4.1

Display Programming - Ethernet Ports


--------------------------------------------------
Laptop Ethernet Port:
DHCP Configuration : Server
IP Address : 192.168.255.81
Network Mask : 255.255.255.0
Default Gateway :

Ethernet Port 1:
DHCP Configuration : Disabled
IP Address : 192.168.2.100
Network Mask : 255.255.255.0
Default Gateway :
Path Type : None
Protocol : None

Ethernet Port 2:
DHCP Configuration : Disabled
IP Address : 192.168.3.100
Network Mask : 255.255.255.0
Default Gateway :
Path Type : None
Protocol : None

Display Programming - Diagnostic Logging


--------------------------------------------------
Message Processing (Layer 7) : Disabled
Routing (Layer 3) : Disabled
Serial Port 1 RX/TX (Layer 2) : Disabled
EZ/EX Logging : Change
EZ/EX Point Change : 3
EZ/EX Logging Interval : 4 Seconds
EZ/EX Recording : Enabled
Ethernet Laptop Port RX/TX (Layer 2) : Disabled
Ethernet Port 1 RX/TX (Layer 2) : Disabled
Ethernet Port 2 RX/TX (Layer 2) : Disabled
Echelon RX/TX : Disabled
CPU RX/TX : Disabled
Digi Protocol Logging Enabled : Disabled

Display Programming - Log Verbosity Settings


--------------------------------------------------
Display Diagnostic Log Verbosity : Info
CP Log Verbosity : 1
VLP Log Verbosity : 1
Slot 2 Log Verbosity : 1
Slot 3 Log Verbosity : 1
Slot 4 Log Verbosity : 1
Slot 5 Log Verbosity : 1
Slot 6 Log Verbosity : 1
Slot 7 Log Verbosity : 1
SSCC3i-1 Log Verbosity : 1
SSCC3i-2 Log Verbosity : 1

Display Programming - Security


--------------------------------------------------
Maintainer Password : **********
Supervisor Password : **********
Security Enabled : None
Session Inactivity Timeout : 20 Minutes

Display Programming - Web Server Access


--------------------------------------------------
Browser Access : Non-Secure (http)
Display Programming - Configuration
--------------------------------------------------
Display Hibernation Time : 15 Minutes
Display Buzzer Enable : Yes

ATCS Route - Configuration


--------------------------------------------------
Route Table Entry Timeout : 400
ATCS IP FIELD UDP Port Number : 13000
ATCS IP FIELD Interface : Echelon

SEAR Configuration
==================

SEAR Application Program Settings: CDL Site Setup Results


-----------------------------------------------------------
CDL Does Not contain any questions.

-----------------------------------------------------------

SEAR Programming - IO Assignment


--------------------------------------------------

Digital Inputs:
--------------------
SEAR Digital Input Maint Call
Name : Maintenance Call
Tag : SP_MC
Algorithm : Discrete
Off State Name : On
On State Name : Off
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 1.1


Name : SP1_1
Tag : SP1_1
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 1.2


Name : SP1_2
Tag : SP1_2
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms
SEAR Digital Input IN 1.1
Name : SP1_3
Tag : SP1_3
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 1.2


Name : SP1_4
Tag : SP1_4
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 2.1


Name : SP2_1
Tag : SP2_1
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 2.2


Name : SP2_2
Tag : SP2_2
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 2.1


Name : SP2_3
Tag : SP2_3
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 2.2


Name : SP2_4
Tag : SP2_4
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input SP 2.1


Name : SP2_5
Tag : SP2_5
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK2 RCV


Name : SP2_6
Tag : SP2_6
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK2 CHK


Name : SP2_7
Tag : SP2_7
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK2 XMT


Name : SP2_8
Tag : SP2_8
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 3.1


Name : SP3_1
Tag : SP3_1
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 3.2


Name : SP3_2
Tag : SP3_2
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 3.1


Name : SP3_3
Tag : SP3_3
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 3.2


Name : SP3_4
Tag : SP3_4
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input SP 3.1


Name : SP3_5
Tag : SP3_5
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK3 RCV


Name : SP3_6
Tag : SP3_6
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms
SEAR Digital Input TRK3 CHK
Name : SP3_7
Tag : SP3_7
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK3 XMT


Name : SP3_8
Tag : SP3_8
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 4.1


Name : SP4_1
Tag : SP4_1
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 4.2


Name : SP4_2
Tag : SP4_2
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 4.1


Name : SP4_3
Tag : SP4_3
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 4.2


Name : SP4_4
Tag : SP4_4
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input SP 4.1


Name : SP4_5
Tag : SP4_5
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK4 RCV


Name : SP4_6
Tag : SP4_6
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK4 CHK


Name : SP4_7
Tag : SP4_7
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK4 XMT


Name : SP4_8
Tag : SP4_8
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 5.1


Name : SP5_1
Tag : SP5_1
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 5.2


Name : SP5_2
Tag : SP5_2
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 5.1


Name : SP5_3
Tag : SP5_3
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 5.2


Name : SP5_4
Tag : SP5_4
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input SP 5.1


Name : SP5_5
Tag : SP5_5
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK5 RCV


Name : SP5_6
Tag : SP5_6
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK5 CHK


Name : SP5_7
Tag : SP5_7
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK5 XMT


Name : SP5_8
Tag : SP5_8
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 6.1


Name : SP6_1
Tag : SP6_1
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input OUT 6.2


Name : SP6_2
Tag : SP6_2
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 6.1


Name : SP6_3
Tag : SP6_3
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 6.2


Name : SP6_4
Tag : SP6_4
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input SP 6.1


Name : SP6_5
Tag : SP6_5
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK6 RCV


Name : SP6_6
Tag : SP6_6
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK6 CHK


Name : SP6_7
Tag : SP6_7
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input TRK6 XMT


Name : SP6_8
Tag : SP6_8
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 7.1


Name : SSCC1 VI-1
Tag : CC1_1
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 7.2


Name : SSCC1 VI-2
Tag : CC1_2
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 7.3


Name : SSCC1 VI-3
Tag : CC1_3
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 7.4


Name : SSCC1 VI-4
Tag : CC1_4
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 7.5


Name : SSCC1 VI-5
Tag : CC1_5
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input 1GC


Name : SSCC1 Gate
Tag : CC1_G
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input 1BELL


Name : SSCC1 Bell
Tag : CC1_B
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 8.1


Name : SSCC2 VI-1
Tag : CC2_1
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 8.2


Name : SSCC2 VI-2
Tag : CC2_2
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 8.3


Name : SSCC2 VI-3
Tag : CC2_3
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 8.4


Name : SSCC2 VI-4
Tag : CC2_4
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input IN 8.5


Name : SSCC2 VI-5
Tag : CC2_5
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input 2GC


Name : SSCC2 Gate
Tag : CC2_G
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input 2BELL


Name : SSCC2 Bell
Tag : CC2_B
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input Main Power


Name : Main Power
Tag : B12_M
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input Stby Power


Name : Stby Power
Tag : B12_S
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

SEAR Digital Input DI1 (J3)


Name : Extern DI1
Tag : DI01
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms
SEAR Digital Input DI2 (J3)
Name : Extern DI2
Tag : DI02
Algorithm : Discrete
Off State Name : Off
On State Name : On
Toggling State Name : Toggling
Off Debounce : 100 ms
On Debounce : 100 ms
Toggle Period : 1000 ms

Analog Inputs:
--------------------
Supply Batt Monitor
Name : Supply Batt Monitor
Tag : VBN
Sample Period : 100 ms
Resolution : 0.5 V
Average Counts : 32

SSCC1 Batt Monitor


Name : SSCC 1 Batt Monitor
Tag : SSCC1
Sample Period : 100 ms
Resolution : 0.5 V
Average Counts : 32

SSCC2 Batt Monitor


Name : SSCC 2 Batt Monitor
Tag : SSCC2
Sample Period : 100 ms
Resolution : 0.5 V
Average Counts : 32

Temperature
Name : Temperature
Tag : Int. Temp
Sample Period : 100 ms
Resolution : 5 F
Average Counts : 32

TEMP (J3)
Name : External Temperature
Tag : Ext. Temp
Sample Period : 100 ms
Resolution : 5 F
Average Counts : 32

BATT MON (J3)


Name : Extern Batt Monitor
Tag : BATT MON
Sample Period : 100 ms
Resolution : 0.5 V
Average Counts : 32

Non-Vital Outputs:
--------------------
RTU 1 (AUX J1 Pin 11)
Name : Aux. Output 1
Tag : RTU1
Off State Name : Open
On State Name : Closed
Toggling State Name : Toggling
Toggle Period : 1 seconds
Duty Cycle : 50 Percent

RTU 2 (AUX J1 Pin 12)


Name : Aux. Output 2
Tag : RTU2
Off State Name : Open
On State Name : Closed
Toggling State Name : Toggling
Toggle Period : 1 seconds
Duty Cycle : 50 Percent

RTU 3 (AUX J1 Pin 13)


Name : Aux. Output 3
Tag : RTU3
Off State Name : Open
On State Name : Closed
Toggling State Name : Toggling
Toggle Period : 1 seconds
Duty Cycle : 50 Percent

RTU 4 (AUX J1 Pin 24)


Name : Aux. Output 4
Tag : RTU4
Off State Name : Open
On State Name : Closed
Toggling State Name : Toggling
Toggle Period : 1 seconds
Duty Cycle : 50 Percent

RTU 5 (AUX J1 Pin 23)


Name : Aux. Output 5
Tag : RTU5
Off State Name : Open
On State Name : Closed
Toggling State Name : Toggling
Toggle Period : 1 seconds
Duty Cycle : 50 Percent

RTU 6 (AUX J1 Pin 10)


Name : Aux. Output 6
Tag : RTU6
Off State Name : Open
On State Name : Closed
Toggling State Name : Toggling
Toggle Period : 1 seconds
Duty Cycle : 50 Percent

RLY 1 (J3)
Name : Relay Output 1
Tag : RLY1
Off State Name : Open
On State Name : Closed
Toggling State Name : Toggling
Toggle Period : 1 seconds
Duty Cycle : 50 Percent

RLY 2 (J3)
Name : Relay Output 2
Tag : RLY2
Off State Name : Open
On State Name : Closed
Toggling State Name : Toggling
Toggle Period : 1 seconds
Duty Cycle : 50 Percent

SEAR Programming - Echelon Modules


--------------------------------------------------
SEAR Module 16
Node Number : 16
Name : GCP4K
Type : GCP5000

SEAR Programming - Communication


--------------------------------------------------
Site Type : None

SEAR Programming - Serial Ports


--------------------------------------------------
SEAR Aux Port Settings:
Baud Rate : 9600
Data Bits : 8
Parity : None
Stop Bits : 1
Flow Ctrl : None

SEAR User Port Settings:


Baud Rate : 9600
Data Bits : 8
Parity : None
Stop Bits : 1
Flow Ctrl : None

Configuration Package File


==========================
Filename : CONFIG-000000A-2023Sep7.PAC
Path : C:\Program Files (x86)\Common Files\Siemens\WebUI\
oce_configuration\admin\test1_0709\
Date/Time : 07/09/2023 14:38:01
OCE Version : 2.10.2