Professional Documents
Culture Documents
ch30 Answers Asal Chem WB
ch30 Answers Asal Chem WB
ch30 Answers Asal Chem WB
Exam-style questions and sample answers have been written by the authors. In examinations, the way marks are awarded
may be different.
Workbook answers
Chapter 30
Exercise 30.1
a i Type of chromatography Stationary phase Mobile phase
paper chromatography water absorbed onto organic liquid or mixture of
cellulose solvents, sometimes aqueous
gas-liquid liquid (long-chain alkane) gas such as N2, H2 or He
chromatography (GLC) absorbed on support
thin layer silica / aluminium support organic solvent
chromatography (TLC)
high-performance liquid non-volatile liquid polar liquid, e.g. methanol
chromatography (HPLC) absorbed on support
distance
ii TLC can be used to separate different c i Rf (0.42) = = 30 × 0.42 = 12.6 cm
types of plant pigments (colourings). 30 cm
A mixture of plant pigments is placed ii By comparing with known Rf when run
on the solid stationary phase of the TLC under identical conditions / by running
sheet. A solvent such as heptane is used suspected compound at the same time to
as the mobile phase. As the solvent runs see if they finish at the same level.
up the sheet, the pigments separate. This iii Takes shorter time to run / can use smaller
is because pigments with more polar samples.
molecules have a greater attraction for
the polar solid used as a stationary d All the components in the mixture must be
phase. The more polar the molecules are, completely separated. Detector must respond
the slower they travel up the sheet. This equally to the different components.
allows separation from molecules that e Approximate % = 22%
are less polar and dissolve more easily in
heptane.
Exercise 30.2
b The mixture to be separated is injected into
the carrier gas and the time noted. The a A. When placed in a strong magnetic field …
gas flows through a long tube containing E. 1
H nuclei behave like tiny magnets and
a long-chain hydrocarbon supported on line …
silica (stationary phase). As the gas moves
through the tube, components, which are H. … themselves up with or against the field.
less soluble in the stationary phase, move D. When the correct frequency of radiation
further, while those that are more soluble is absorbed, the nuclei …
are in equilibrium with the stationary phase
for longer. The compounds leave the tube B. … ‘flip’ from being lined up with the
at different times. The time taken between magnetic field (lower energy) to …
injection and detection is called the retention
time. G. … being lined up against the magnetic
field (higher energy).
CH3 group attached to carbonyl group at δ = b The absorption frequencies overlap, so you
2.3 (3 H attached) cannot be sure which group is responsible.
CH3 group at δ = about 1.4 (3 H attached) d i The deuterium atoms do not absorb in the
same region as protons.
−O─CH2─R group at δ = about 4.0 (2 H
attached) ii Compare the non-deuterated spectrum
with the deuterated one.
e i −CH3 splits into three because there are
two 1H atoms on the −CH2− group next to If some of the original peaks disappear, they
it. were the −OH or −NH− groups present
in the sample.
−CH2− peak splits into four because there
are three 1H atoms on the −CH3 group e i 2 C atoms in 2 −CH3 groups attached
next to it. to −CH2−
−OH group is not split because of 1H 1 C atom in −CH2− group attached to −CH3
exchange with other alcohol or water
molecules.
They are the same height because there is 1 of Allow solvent to run up the stationary phase
each type of carbon. until solvent has nearly reached the top [1]
There is 1 CH3 and one −CH2 − attached to an Visualise spot with locating agent or
OH group. ultraviolet light [1]
(allow: 90–99 for theobromine and 194 Stationary phase is a long-chain hydrocarbon
to 202 for caffeine) [1] supported on silica (in long tube). [1]
% caffeine = 198 / (94.5 + 198) = 67% [1] Idea of equilibrium between the ‘solutes’ in
the stationary and mobile phases. [1]
[Total: 15]
Components which are less soluble in the
Question 3 stationary phase move further (or reverse
argument). [1]
a Shift at 10 = aromatic aldehyde CHO
connected to benzene ring [1] The time taken between injection and
detection / retention time is measured. [1]
Shift just before 8 = 3 H attached to C6H5 [1]
Retention time values compared with
Shift at just before 8 = possibly OH attached retention times of
to benzene ring [1]
known substances under identical
Shift at 4 = 3 H attached to CH3O− group [1] conditions. [1]
b The mixture is injected into a carrier gas [Total: 10]
which is the mobile phase. [1]