Professional Documents
Culture Documents
DM 1
DM 1
As per DM rules, the average compressive stress under working loads shall not exceed ________
of the design cube strength of pile concrete at 28 days.
a) 50%
b) 35%
c) 25% answer
d) 10%
Q2. Mechanical splice (min. 50d) may be used after demonstrating to the site engineer that the
splice can develop ______ of the specified yield strength of the bar.
a) 50%
b) 100%
c) 125%. Answer
d) 150%
Ans= C
Q4. In strap beam in footings, the maximum reinforcement should be in the___________ of beam.
a) bottom
b) sides
c) Top. Answer
d) same top and bottom
Q5. Piles are used in deep foundation primarily to transfer loads from
Ans. Super structure through weak strata or water onto stronger and stiffer soil or rock.
Q6. In offshore projects, piles can be driven down to a maximum of ______ meter.
a) 90
b) 100
c) 30
d) 150. Answer
a) stem
b) shear key
c) toe
Q8. The maximum deflection for contiliver beam under uniformly distributed load is
a) PL3/48EI
b) PL³/ 3El
c) WL2/2
d) wL4/8Ei. Answer
Q9. As per DM requirements the modification factor for Post tensioing slab is
a) 0.35
b) 0.7
c) 0.25
d) 0.5 Answer
a) 30°
b) 40°. Answer
c) 45°
d) 25°
Q11. As per DIN 1048 standards, water penetration at 28 days test should not acceed max of
a) 5mm
b) 10mm. Answer
c) 15mm
d) 7mm
Q12. As per ASTM C1202 the rapid chloride penetration at 28 days test for RC piles should not
acceed maximum of
a) 1000 Coulombs
b) 1500 Coulombs
c) 700 Coulombs
a) 57000/fc' N/mm²
c) 5000√fc' N/mm²
d) None
Q14. As per ACI 318-14 the maximum allowable elongation in post tensioing tendons is
a) 5%
b) 3%
c) 10%
d) 7%. Answer
Q15. Why vibrators are not used in piles concrete?
Q16. If d is depth of pt slab than maximum spacing for pt tendons as per ACI 318-05 is
a) 5d or 5ft
b) 10d or 5ft
c) 8d or 5ft. Answer
d) 7d or 7ft
Q17. Which test is required for piles during construction? a) dynamic test
b) integrity test
Q18. The minimum diameter of spiral shear links used for piles steel as per DM rules is a) 8mm
b) 10mm. Answer
c) 12mm
d) 6mm
Q19. The maximum acceptable settlement for the piles under working load is
a) 8mm. Answer
b) 10mm
c) 12mm
d) 4mm
Q20. The area of main reinforcement bars for piles shall not be less than % of sectional area.
a) 2
b) 3
c) 1 Answer
d) 0.8