ARCHITECT

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 4

1. Based on Rule 8 of NBC, under Table 8.G.

1 wide, what will be the maximum BHL number of


Easement Along Bodies/Way by Location, what shall be observed
is the minimum width of easement required for regardless of use or occupancy, lot size, lot
agricultural areas? dimensions, lot frontage and like
a. 3m wide considerations?
b. 10m wide a. 2 storeys
c. 20m wide b. 2.5 storeys
d. 40m wide c. 3 storeys
d. 9 storeys
2. Based on Rule 8 of NBC, under Maximum
Configuration of Basement 6. What is the Minimum Required Parking Slot for a
Levels, what is the minimum RROW width that MOTEL?
services the lot on which the a. 1 car slot for every unit
basement can be constructed? b. 1 car slot for every 20 beds
a. 8m wide c. 1 car slot for every 5 rooms
b. 10m wide d. 1 car slot for every 2 units
c. 20m wide
d. 24m wide 7. Multi-floor parking garages may serve the 20%
parking requirements of
3. For a R-3 use or occupancy with a firewall on the building/structure within ____________,
two (2) sides, a firewall can provided at
be erected on a maximum of ___ of the total least 80% of the parking requirements are
length of each side property line; provided that complied with and integrated in
all firewall construction shall not exceed ___ of the building design.
the total perimeter of the R-3 property. a. 250m. radius
a. 90%, 100% b. 300m radius
b. 85%, 50% c. 200m radius
c. 90%, 50% d. 100m radius
d. 85%, 65%
8. Based on SECTION 708. Minimum Requirements
for Group A Dwellings of
4. What is the maximum height to be allowed for Rule 7 NBC, Footings shall be of sufficient size
buildings/structures based and strength to support the
on their proposed use or occupancy? load of the dwelling and shall be at least
a. Building Height Limitation _________ thick and _________
b. Building Height Limit below the surface of the ground.
c. Building Height Restriction a. 250mm, 600mm
d. Allowable Maximum Volume of Building b. 300mm, 600mm
c. 200mm, 700mm
d. 150mm, 650mm

5. If only one (1) RROW services a lot and such is


only 6.00 to 7.00 meters 9. Based on SECTION 708. Minimum Requirements
for Group A Dwellings of
Rule 7 NBC, All electrical installations shall 12. Identify the illustration:
conform to the requirements of
the:
a. Philippine Electrical Engineer
b. Professional Electrical Engineer
c. Philippine Electrical Code
d. Philippine Electric Code

10. Based on SECTION 708. Minimum Requirements


for Group A Dwellings
of Rule 7 NBC, Mechanical systems and/or
equipment installations shall be
subject to the requirements of the:
a. Philippine Mechanical Engineer
b. Professional Mechanical Engineer
c. Philippine Mechanical Engineer Code
a. Inside Lot
d. Philippine Mechanical Engineering Code
b. Corner Through Lot
c. Interior Lot
11. Identify the illustration:
d. Through Lot

13. The size of an average automobile (car) parking


slot must be computed
at ________ for perpendicular or diagonal
parking.
a. 3m x 5m
b. 2.15m x 6m
c. 2.50m x 5m
d. 2.10m x 5m

14. It refers to the portion of the RROW reckoned


from the natural grade
a. Rotunda line up to the finished surface of the
b. Turn Court roadway/carriageway and/ or the
c. Cul-de-sac sidewalk/arcade.
d. Road Right of Way a. RROW ABOVE GRADE
b. RROW AT GRADE
c. RROW BELOW GRADE
d. Road Right of Way
Questions: b. Storage 1
c. Lobby
1. What is the lot dimension of the project? d. Business Center
a. 24 x 99 m
b. 53 x 105 m 7. Given that the slab at second floor is 0.12
c. 48 x 99 m meters thick, how many kilograms of steel
d. 24 x 91 m reinforcing bars needed if it requires 15kgs
of reinforcing bars per cubic meter of
2. If the building of this compound is defined concrete?
as rectangle, what will be the building Exclude the area of stairwell of 3m x 6m.
dimension a. 756 kgs
of the project? b. 723.6 kgs
a. 24 x 99 m c. 6,300 kgs
b. 53 x 105 m d. 6,030 kgs
c. 48 x 99 m
d. 24 x 91 m 8. What is the Total Gross Floor Area of the
project?
3. What is the range of Percentage of Site a. 2,484 sqm
Occupancy of the project? b. 6,679 sq.m
a. 50% c. 2,064 sq
b. 40% d. 1,796 sq.m
c. 37%
d. 35% 9. What is the declared zoning classification of
the site?
4. What is the range of the number of tiles to a. SPE
be used in the Engineering Department b. UTS
office c. GI
using 600mm x 1200mm ceiling tiles? d. Division C
a. 233 pcs
b. 235 pcs 10. Base on National Structural Code of the
c. 58 pcs Philippines 2015, Section 303 Foundation
d. 250 pcs Investigation, how many boreholes are
required to be performed and evaluated for
5. What is the percentage of USA in relation the
with the lot? project?
a. 20% a. 2 boreholes
b. 30% c. 3 boreholes
c. 15% b. 4 boreholes
d. 25% d. 1 borehole only

6. What is the area/room aligned in ground


floor with the purchasing department
office?
a. Storage 2

You might also like