Siemens Hipath Commands 230930 211346

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 73

Hipath 4500 System Commands Switching R&D, ITI LTD.

HIPATH 4500
SYSTEM COMMANDS

ASCON PHASE – III

INTEGRATED SWITCH

ITI LIMITED BANGALORE – 560 016

6/16/2023 1/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

CONTENTS

1. SLMA 24 SUBSCRIBERS CREATION 3


2. STMD2 SUBSCRIBERS CREATION 4
3. E&M TRUNK CREATION (DECADIC SIGNALING) 5
4. E&M TRUNK CREATION (MF SIGNALING) 8
5. E&M TRUNK CREATION (DTMF SIGNALING) 11
6. A/A TRUNK CREATION (DECADIC SIGNALING) 14
7. A/A TRUNK CREATION (MF SIGNALING) 17
8. STMA CREATION. 20
9. DIUN2 CREATION (CAS- DECADIC SIGNALING) 29
10. DIUN2 CREATION (CAS- MF SIGNALING) 32
11. E1-PRI CREATION 35
12. CREATION OF HOTLINE 36
13. CREATION OF OVERRIDE 39
14. CREATION OF CALL TRANSFER 39
15. CREATION OF CONFERENCE 39
16. CREATION OF CALL PICKUP 39
17. CREATION OF USER GROUP 39
18. CREATION OF ALTERNATE ROUTE 40
19. CREATION OF PIN 41
20. CREATION OF CALL FORWARDING 43
21. MALICIOUS CALL 44
22. CREATION OF SIUX CARD (MFC) 47
23. CALL DETAIL RE CORD 49
24. CREATION OF MULIPLE SUBSCRIBER NUMBER (MSN) 50
25. CARD RESET 50
26. DEVICE SWITCH OF SWITCHING UNIT 50
27. STATUS DISPLAY IN SWITCHING UNIT 50
28. UPDATING THE DATABASE IN THE SYSTEM 50

6/16/2023 2/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

1. SLMA 24 Subscribers creation.

To create subscribers the ADD-BCSU, ADD-WABE, ADD-SCSU commands to be given.

1. ADD-BCSU: (Configuration of Card Position)


MTYPE=PER,
LTG=1,
LTU=1,
SLOT=121,
PARTNO="Q2246-X",
FCTID=0,
LWVAR="0",
HWYBDL=A;

( ADD-BCSU:PER,1,1,121,"Q2246-X ",0,0,,,,,,A; )

2. ADD-WABE: (Configuration of Digit Analysis)


CD=2000,
DAR=STN,
CHECK=N;

(ADD-WABE: 2000,,, STN, N,,,,,,,,; )

3. ADD-SCSU: (Configuration of Subscriber)


STNO=2000,
PEN=1-1-121-0,
DVCFIG=ANATE,
DPLN=0,
ITR=0,
COS1=2,
COS2=2,
LCOSV1=1,
LCOSV2=1,
LCOSD1=1,
LCOSD2=1,
SPDC1=0,
COSX=0,
SPDI=0,
COFIDX=0,
DIAL=DP,
INS=YES,
SSTNO=NO,
HMUSIC=0,
CONN=DIR,
FLASH=YES,
DTMFBLK=NO;

( ADD-SCSU:2000,1-1-121-0,ANATE,0,0,2,2,1,1,1,1,0,,0,0,0,,,DP,,,,,YES,,NO,,,,0,DIR,YES,NO; )

6/16/2023 3/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

2. STMD2 Subscribers creation.

To create subscribers the ADD-BCSU, ADD-WABE, ADD-SBCSU commands to be given

1. ADD-BCSU:
MTYPE=PER,
LTG=1,
LTU=2,
SLOT=121,
PARTNO="Q2163-X100",
FCTID=1,
LWVAR="0",
HWYBDL=A;

(ADD-BCSU:PER,1,2,121,"Q2163-X100",1,0,,,,,,A; )

2.ADD-WABE:
CD=6000,
DAR=STN,
CHECK=N;

(ADD-WABE: 6000,,,STN,N,,,,,,,,; )

3. ADD-SBCSU: (Configuration of S0 bus)


STNO=6000,
OPT=FBUS,
CONN=DIR,
PEN=1-2-121-0,
DVCFIG=SET600,
COS1=1,
COS2=2,
LCOSV1=1,
LCOSV2=2,
LCOSD1=1,
LCOSD2=1,
DPLN=0,
ITR=0,
SSTNO=N,
COSX=0,
SPDI=0,
SPROT=SBDSS1,
INS=Y,
ALARMNO=0,
EXTBUS=Y,
RCBKB=N,
RCBKNA=N,
CBKBMAX=3,
HMUSIC=0;

(ADD-SBCSU:6000,FBUS,DIR,1-2-121-0,SET600,1,2,1,2,1,1,0,0,N,0,0,,,SBDSS1,,,,Y,0,,,,,Y,N,N,,3,0,; )
6/16/2023 4/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

3. E&M Trunk creation. (Decadic signaling)

To create subscribers the ADD-BCSU, ADD-BUEND, ADD-TACSU, ADD-RICHT, ADD-LDAT,


ADD-WABE, ADD-LDPLN commands to be given

1. ADD-BCSU:
MTYPE=PER,
LTG=1,
LTU=1,
SLOT=103,
PARTNO="Q2292-X100",
FCTID=0,
LWVAR="0",
HWYBDL=A;

( ADD-BCSU:PER,1,1,103,"Q2292-X100",0,0,,,,,,A; )

2. ADD-BUEND: (Configuration of Trunk Group)


TGRP=40,
NAME="TMEW2",
NO=1,
RSV=N,
TRACENO=0,
ACDTHRH=*,
PRIONO=2,
TDDRFLAG=ON,
GDTRRULE=0,
ACDPMGRP=0,
CHARCON=NEUTRAL;

( ADD-BUEND:40,"TMEW2 ",1,N,0,*,2,ON,0,0,NEUTRAL; )

3. ADD-TACSU: (Configuration of Analog Trunk Circuits)


PEN=1-1-103-0,
COTNO=10,
COPNO=10,
DPLN=0,
ITR=0,
COS=20,
LCOSV=1,
LCOSD=1,
TGRP=40,
COFIDX=0,
CCT="E&M",
DESTNO=0,
ALARMNO=0,
CARRIER=1,
ZONE=EMPTY,
LIN=0,
CIDDGTS=NONE,
6/16/2023 5/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

CBMATTR=NONE,
CLASSMRK=EC&G711&G729OPT,
DITIDX=0,
TRTBL=GDTR,
RULEIDX=0,
INS=Y,
DEVTYPE=TC,
DEV=EMCONT2,
MFCVAR=0,
SUPPRESS=0,
DGTCNT=0,
TESTNO=1,
CIRCIDX=17,
CDRINT=1,
CCTINFO=0,
DIALTYPE=DIP,
DIALVAR=0-0,
COEX=0;

( ADD-TACSU:1-1-103-0,,10,10,0,0,20,1,1,,40,0,"E&M
",0,,0,1,EMPTY,0,NONE,NONE,,EC&G711&G729OPT,"",0,GDTR,0,,Y,TC,EMCONT2,0,,0,0,1,17,1,
0,DIP-DIP,0-0,0; )

4. ADD-RICHT: (Configuration of Trunk Route)


MODE=LRTENEW,
LRTE=40,
LSVC=ALL,
NAME="E&M",
TGRP=40,
DNNO=1-1-30,
ROUTOPT=YES,
ROUTATT=NO,
EMCYRTT=NO,
PDNNO=0,
CHARCON=NEUTRAL,
CONFTONE=NO,
RERINGRP=NO;

( ADD-RICHT:LRTENEW,40,ALL,"E&M",40,1-1-
30,YES,,,,"",,,,,,NO,NO,"",0,NEUTRAL,NO,NO,NO; )

6/16/2023 6/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5. ADD-LDAT: (Administrating the Trunk Route)


LROUTE=40,
LSVC=ALL,
LVAL=1,
TGRP=40,
ODR=2,
LAUTH=1,
CARRIER=1,
ZONE=EMPTY,
LATTR=WCHREG,
VCCYC=4;

( ADD-LDAT:40,ALL,1,,40,2,1,,1,EMPTY,WCHREG,,4,,,,,,; )

6. ADD-WABE: (Configuration of Digit Analysis)


CD=40,
DAR=TIE,
CHECK=N;

(ADD-WABE: 40,,,TIE,N,,,,,,,,; )

7. ADD-LDPLN: (Administration of Dialing Plan)


LDP="40"-"W"-"XXXX",
LROUTE=40,
LAUTH=1,
PINDP=N;

(ADD-LDPLN:40-W-XXXX,,40,,1,,,,N; )

6/16/2023 7/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

4. E&M Trunk creation. (MF signaling)

To create subscribers the ADD-BCSU, ADD-BUEND, ADD-TACSU, ADD-RICHT, ADD-LDAT,


ADD-WABE, ADD-LDPLN commands to be given

1. ADD-BCSU:
MTYPE=PER,
LTG=1,
LTU=3,
SLOT=49,
PARTNO="Q2292-X100",
FCTID=0,
LWVAR="0",
HWYBDL=A;

( ADD-BCSU:PER,1,3,49,"Q2292-X100",0,0,,,,,,A; )

2. ADD-BUEND:
TGRP=42,
NAME="E&M_MF",
NO=2,
RSV=N,
TRACENO=0,
ACDTHRH=*,
PRIONO=2,
TDDRFLAG=ON,
GDTRRULE=0,
ACDPMGRP=0,
CHARCON=NEUTRAL;

( ADD-BUEND:42,"E&M_DTMF ",2,N,0,*,2,ON,0,0,NEUTRAL; )

3. ADD-TACSU:
PEN=1-3-49-0,
COTNO=11,
COPNO=11,
DPLN=0,
ITR=0,
COS=10,
LCOSV=1,
LCOSD=1,
TGRP=42,
COFIDX=0,
CCT="E&M MFC",
DESTNO=42,
ALARMNO=0,
CARRIER=1,
ZONE=EMPTY,
LIN=0,

6/16/2023 8/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

CIDDGTS=NONE,
CBMATTR=NONE,
CLASSMRK=EC&G711&G729OPT,
DITIDX=0,
TRTBL=GDTR,
RULEIDX=0,
INS=Y,
DEVTYPE=TC,
DEV=EMCONT2,
MFCVAR=1,
SUPPRESS=0,
DGTCNT=0,
TESTNO=1,
CIRCIDX=17,
CDRINT=1,
CCTINFO=0,
DIALTYPE=MFC,
DIALVAR=0-0,
COEX=0;

( ADD-TACSU:1-3-49-0,,11,11,0,0,10,1,1,,42,0,"E&M
DTMF",42,,0,1,EMPTY,0,NONE,NONE,,EC&G711&G729OPT,"
",0,GDTR,0,,Y,TC,EMCONT2,1,,0,0,1,17,1,0,MFC-MFC,0-0,0; )

4.ADD-RICHT:
MODE=LRTENEW,
LRTE=42,
LSVC=ALL,
NAME="E&M-MF",
TGRP=42,
DNNO=1-1-42,
ROUTATT=NO,
EMCYRTT=NO,
PDNNO=0,
CHARCON=NEUTRAL,
CONFTONE=NO,
RERINGRP=NO;

( ADD-RICHT:LRTENEW,42,ALL,"E&M-DTMF ",42,1-1-
42,,,,,"",,,,,,NO,NO,"",0,NEUTRAL,NO,NO,NO; )

6/16/2023 9/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5. ADD-LDAT:
LROUTE=42,
LSVC=ALL,
LVAL=1,
TGRP=42,
ODR=2,
LAUTH=1,
CARRIER=1,
ZONE=EMPTY,
LATTR=NONE,
DNNO=1-1-42;

( ADD-LDAT:42,ALL,1,,42,2,1,,1,EMPTY,NONE,1-1-42,4,,,,,,; )

6. ADD-WABE:
CD=42,
DAR=TIE,
CHECK=N;

(ADD-WABE: 42,,,TIE,N,,,,,,,,; )

7. ADD-LDPLN:
LDP="42"-"XXXX",
LROUTE=42,
LAUTH=1,
PINDP=N;

(ADD-LDPLN: 42-XXXX,,42,,1,,,,N; )

6/16/2023 10/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5. E&M Trunk creation. (DTMF signaling)

To create subscribers the ADD-BCSU, ADD-BUEND, ADD-TACSU, ADD-RICHT, ADD-LDAT,


ADD-WABE, ADD-LDPLN commands to be given

1. ADD-BCSU:
MTYPE=PER,
LTG=1,
LTU=3,
SLOT=61,
PARTNO="Q2292-X100",
FCTID=0,
LWVAR="0",
HWYBDL=A;

( ADD-BCSU:PER,1,3,61,"Q2292-X100",0,0,,,,,,A; )

2. ADD-BUEND:
TGRP=46,
NAME="TMEW2-DTMF",
NO=10,
RSV=N,
TRACENO=0,
ACDTHRH=*,
PRIONO=2,
TDDRFLAG=ON,
GDTRRULE=0,
ACDPMGRP=0,
CHARCON=NEUTRAL;

( ADD-BUEND:46,"TMEW2-DTMF ",10,N,0,*,2,ON,0,0,NEUTRAL; )

3. ADD-TACSU:
PEN=1-3-61-0,
COTNO=15,
COPNO=15,
DPLN=0,
ITR=0,
COS=10,
LCOSV=1,
LCOSD=1,
TGRP=46,
COFIDX=0,
CCT="DTMF",
DESTNO=0,
ALARMNO=0,
CARRIER=1,
ZONE=EMPTY,
LIN=0,
CIDDGTS=NONE,
6/16/2023 11/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

CBMATTR=NONE,
CLASSMRK=EC&G711&G729OPT,
DITIDX=0,
TRTBL=GDTR,
RULEIDX=0,
INS=Y,
DEVTYPE=TC,
DEV=EMCONT2,
MFCVAR=0,
SUPPRESS=0,
DGTCNT=0,
TESTNO=1,
CIRCIDX=17,
CDRINT=1,
CCTINFO=0,
DIALTYPE=DTMF,
DIALVAR=0-0,
COEX=0;

( ADD-TACSU:1-3-61-0,,15,15,0,0,10,1,1,,46,0,"DTMF
",0,,0,1,EMPTY,0,NONE,NONE,,EC&G711&G729OPT,"
",0,GDTR,0,,Y,TC,EMCONT2,0,,0,0,1,18,1,0,DTMF-DTMF,0-0,0; )

4.ADD-RICHT:
MODE=LRTENEW,
LRTE=46,
LSVC=VCE,
TGRP=46,
DNNO=1-1-46,
ROUTOPT=YES,
ROUTATT=NO,
EMCYRTT=NO,
PDNNO=0,
CONFTONE=NO,
RERINGRP=NO;

( ADD-RICHT:LRTENEW,46,VCE,"",46,1-1-46,,,,,"",,,,,,NO,NO,"",0,,NO,NO,NO; )

6/16/2023 12/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5. ADD-LDAT:
LROUTE=46,
LSVC=VCE,
LVAL=1,
TGRP=46,
ODR=2,
LAUTH=1,
CARRIER=1,
ZONE=EMPTY,
LATTR=NONE,
VCCYC=4;

( ADD-LDAT:46,VCE,1,,46,2,1,,1,EMPTY,NONE,,4,,,,,,; )

6. ADD-WABE:
CD=46,
DAR=TIE,
CHECK=N;

( ADD-WABE:46,,,TIE,N,,,,,,,,; )

7. ADD-LDPLN:
LDP="46"-"XXXX",
LROUTE=46,
LAUTH=1,
PINDP=N;

(ADD-LDPLN: 46-W-Z,,46,,1,,,,N; )

6/16/2023 13/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

6. A/A Trunk creation. (Decadic signaling)

To create subscribers the ADD-BCSU, ADD-BUEND , ADD-TACSU , ADD-RICHT, ADD-LDAT,


ADD-WABE, ADD-LDPLN commands to be given

1.ADD-BCSU:
MTYPE=PER,
LTG=1,
LTU=1,
SLOT=91,
PARTNO="Q2064-X100",
FCTID=0,
LWVAR="0",
HWYBDL=A;

( ADD-BCSU:PER,1,1,91,"Q2064-X100",0,0,,,,,,A; )

2.ADD-BUEND:
TGRP=30,
NAME="TMLR",
NO=4,
RSV=N,
TRACENO=0,
ACDTHRH=*,
PRIONO=2,
TDDRFLAG=ON,
GDTRRULE=0,
ACDPMGRP=0,
CHARCON=NEUTRAL;

( ADD-BUEND:30,"TMLR ",4,N,0,*,2,ON,0,0,NEUTRAL; )

3.ADD-TACSU:
PEN=1-1-91-0,
COTNO=10,
COPNO=10,
DPLN=0,
ITR=0,
COS=20,
LCOSV=1,
LCOSD=1,
TGRP=30,
COFIDX=0,
CCT="A/A",
DESTNO=0,
ALARMNO=0,
CARRIER=1,
ZONE=EMPTY,
LIN=0,
CIDDGTS=NONE,
6/16/2023 14/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

CBMATTR=NONE,
CLASSMRK=EC&G711&G729OPT,
DITIDX=0,
TRTBL=GDTR,
RULEIDX=0,
INS=Y,
DEVTYPE=TC,
DEV=TMLRUD,
MFCVAR=0,
SUPPRESS=0,
DGTCNT=0,
TESTNO=1,
CIRCIDX=0,
CDRINT=1,
CCTINFO=0,
DIALTYPE=DIP,
DIALVAR=0-0,
COEX=0;

( ADD-TACSU:1-1-91-0,,10,10,0,0,20,1,1,,30,0,"A/A
",0,,0,1,EMPTY,0,NONE,NONE,,EC&G711&G729OPT,"
",0,GDTR,0,,Y,TC,TMLRUD,0,,0,0,1,0,1,0,DIP-DIP,0-0,0; )

4.ADD-RICHT:
MODE=LRTENEW,
LRTE=30,
LSVC=ALL,
NAME="TMLR",
TGRP=30,
DNNO=1-1-20,
ROUTOPT=YES,
ROUTATT=NO,
EMCYRTT=NO,
PDNNO=0,
CHARCON=NEUTRAL,
CONFTONE=NO,
RERINGRP=NO;

( ADD-RICHT:LRTENEW,30,ALL,"TMLR ",30,1-1-
20,YES,,,,"",,,,,,NO,NO,"",0,NEUTRAL,NO,NO,NO; )

6/16/2023 15/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5.ADD-LDAT:
LROUTE=30,
LSVC=ALL,
LVAL=1,
TGRP=30,
ODR=2,
LAUTH=1,
CARRIER=1,
ZONE=EMPTY,
LATTR=WCHREG,
DNNO=4;

( ADD-LDAT:30,ALL,1,,30,2,1,,1,EMPTY,WCHREG,,4,,,,,,; )

6.ADD-WABE:
CD=30,
DAR=TIE,
CHECK=N;

( ADD-WABE:30,,,TIE,N,,,,,,,,; )

7.ADD-LDPLN:
LDP="30"-"W"-"Z",
LROUTE=30,
LAUTH=1,
PINDP=N;

( ADD-LDPLN:30-W-Z,,30,,1,,,,N; )

6/16/2023 16/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

7. A/A Trunk creation. (MF signaling)

To create subscribers the ADD-BCSU, ADD-BUEND , ADD-TACSU , ADD-RICHT, ADD-LDAT,


ADD-WABE, ADD-LDPLN commands to be given

1.ADD-BCSU:
MTYPE=PER,
LTG=1,
LTU=3,
SLOT=31,
PARTNO="Q2064-X100",
FCTID=0,
LWVAR="0",
HWYBDL=A;

( ADD-BCSU:PER,1,3,31,"Q2064-X100",0,0,,,,,,A; )

2.ADD-BUEND:
TGRP=32,
NAME="TMLR-MFC",
NO=1,
RSV=N,
TRACENO=0,
ACDTHRH=*,
PRIONO=2,
TDDRFLAG=ON,
GDTRRULE=0,
ACDPMGRP=0,
CHARCON=NEUTRAL;

( ADD-BUEND:32,"TMLR-MFC ",1,N,0,*,2,ON,0,0,NEUTRAL; )

3.ADD-TACSU:
PEN=1-3-31-0,
COTNO=11,
COPNO=11,
DPLN=0,
ITR=0,
COS=10,
LCOSV=1,
LCOSD=1,
TGRP=32,
COFIDX=0,
CCT="TMLR-MFC",
DESTNO=0,
ALARMNO=0,
CARRIER=1,
ZONE=EMPTY,
LIN=0,

6/16/2023 17/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

CIDDGTS=NONE,
CBMATTR=NONE,
CLASSMRK=EC&G711&G729OPT,
DITIDX=0,
TRTBL=GDTR,
RULEIDX=0,
INS=Y,
DEVTYPE=TC,
DEV=TMLRUD,
MFCVAR=1,
SUPPRESS=0,
DGTCNT=0,
TESTNO=1,
CIRCIDX=0,
CDRINT=1,
CCTINFO=0,
DIALTYPE=MFC,
DIALVAR=0-0;

( ADD-TACSU:1-3-31-0,,11,11,0,0,10,1,1,,32,0,"TMLR-MFC
",0,,0,1,EMPTY,0,NONE,NONE,,EC&G711&G729OPT,"
",0,GDTR,0,,Y,TC,TMLRUD,1,,0,0,1,0,1,0,MFC-MFC,0-0,0; )

4.ADD-RICHT:
MODE=LRTENEW,
LRTE=32,
LSVC=ALL,
NAME="TMLR-MFC",
TGRP=32,
DNNO=1-1-32,
ROUTATT=NO,
EMCYRTT=NO,
PDNNO=0,
CHARCON=NEUTRAL,
CONFTONE=NO,
RERINGRP=NO;

( ADD-RICHT:LRTENEW,32,ALL,"TMLR-MFC ",32,1-1-
32,,,,,"",,,,,,NO,NO,"",0,NEUTRAL,NO,NO,NO; )

6/16/2023 18/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5.ADD-LDAT:
LROUTE=32,
LSVC=ALL,
LVAL=1,
TGRP=32,
ODR=2,
LAUTH=1,
CARRIER=1,
ZONE=EMPTY,
LATTR=NONE,
VCCYC=4;

( ADD-LDAT:32,ALL,1,,32,2,1,,1,EMPTY,NONE,,4,,,,,,; )

6.ADD-WABE:
CD=32,
DAR=TIE,
CHECK=N;

( ADD-WABE:32,,,TIE,N,,,,,,,,; )

7.ADD-LDPLN:
LDP="32"-"W"-"Z",
LROUTE=32,
LAUTH=1,
PINDP=N;

( ADD-LDPLN:32-W-Z,,32,,1,,,,N; )

6/16/2023 19/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

8. STMA Creation. (Ist Card)

To create subscribers the ADD-BCSU, ADD-BDAT , ADD-BUEND, ADD-TDCSU , ADD-RICHT,


ADD-LDAT, ADD-WABE, ADD-LDPLN commands to be given

Ist Card:
1.ADD-BCSU:
MTYPE=PER,
LTG=1,
LTU=2,
SLOT=25,
PARTNO="Q2160-X",
FCTID=5,
LWVAR="0",
HWYBDL=A;

( ADD-BCSU:PER,1,2,25,"Q2160-X ",5,0,,,,,,A; )

2.ADD-BDAT: (Administration of Module Data)


LTG=1,
LTU=2,
SLOT=25,
TYPE=STMA,
OPMODE=NW20,
ATMADDR=920753201,
ATMNPI=NSAP,
L1MODE=SDH,
REASBUF=16,
ATMPROT=UNI40,
PATTERN=213,
SIGVPI=0,
=,
=,
=,
=,
=,
=,
=,
=,
VPCI0=0
VPCI1=1
VPCI2=2
VPCI3=3
VPCI4=4
VPCI5=5
VPCI6=6
VPCI7=7;

( ADD-BDAT:1,2,25,STMA,NW20,910153200,NSAP,SDH,16,UNI40,213,0,,,,,,,,,0,1,2,3,4,5,6,7; )

6/16/2023 20/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

3.ADD-BUEND:
TGRP=100,
NAME="STMA TEST",
NO=30,
RSV=N,
TRACENO=0,
ACDTHRH=*,
PRIONO=2,
TDDRFLAG=ON,
GDTRRULE=0,
ACDPMGRP=0,
CHARCON=NEUTRAL;

( ADD-BUEND:100,"STMA-TEST ",30,N,0,*,2,ON,0,0,NEUTRAL; )

4.ADD-TDCSU: (Configuration og Digital Trunks)


OPT=NEW,
PEN=1-02-025-1,
COTNO=1,
COPNO=1,
DPLN=0,
ITR=0,
COS=1,
LCOSV=1,
LCOSD=1,
CCT="STMA SVC",
=1
PROTVAR=ECMAV2,
SEGMENT=8,
=,
DEDSVC=NONE,
=,
=,
=,
TRTBL=GDTR,
SIDANI=N,
ATNTYP=TIE,
CBMATTR=NONE,
TCHARG=N,
SUPPRESS=0,
=,
=,
=,
=,
=,
=,
TRACOUNT=31,
SATCOUNT=MANY,
NNO=1-1-345,
ALARMNO=0,

6/16/2023 21/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

FIDX=1,
CARRIER=1,
ZONE=EMPTY,
COTX=1,
FWDX=1,
CHIMAP=N,
=,
=,
=,
=,
=,
UUSCCX=16,
UUSCCY=8,
FNIDX=1,
NWMUXTIM=10,
=,
CLASSMRK=EC&G711&G729OPT,
=,
TGRP=100,
SRCHMODE=ASC,
INS=Y,
DEV=ATMSVC,
BCHAN=1&&30,
BCNEG=N,
BCGR=1,
PERMACT1=Y,
PERMACT2=Y,
MASTER=N,
TEIVERIF=N,
AAL5TIM=65535,
ERRTIM=50,
FILLLEV=47,
ATMADDR=920753201,
ATMNPI=NSAP,
ADDREXT=45;

( ADD-TDCSU:NEW,1-02-025-1,1,1,0,0,1,1,1,"STMA-SVC
",1,ECMAV2,8,,NONE,,,,GDTR,N,TIE,NONE,N,0,,,,,,,31,MANY,1-1-
345,0,1,1,EMPTY,1,1,N,,,,,,16,8,1,10,,EC&G711&G729OPT,"",100,ASC,Y,ATMSVC,1&&30,N,1,Y,
Y,N,N,65535,50,47,920753201,NSAP,45; )

Note: This command must be used as many times as many circuits required. But maximum circuits are
0 to 127.

6/16/2023 22/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5.ADD-RICHT:
MODE=LRTENEW,
LRTE=100,
LSVC=ALL,
NAME="STMA SVC",
TGRP=100,
DNNO=1-1-345,
=YES
=,
=,
=,
=,
=,
=,
=,
DTMFCNV=FIX,
DTMFPULS=PP300,
DESTNO=1
=20,
=20,
ROUTATT=NO,
EMCYRTT=NO,
=,
PDNNO=10-10-502,
CHARCON=NEUTRAL,
=NO
CONFTONE=NO,
RERINGRP=NO;

( ADD-RICHT:LRTENEW,100,ALL,"STMA-SVC ",100,1-1-345,YES,,,,"",,,,20,20,NO,NO,"",10-
10-502,NEUTRAL,NO,NO,NO; )

5.ADD-LDAT:
LROUTE=100,
LSVC=ALL,
LVAL=1,
=,
TGRP=100,
ODR=1,
LAUTH=1,
=,
CARRIER=1,
ZONE=EMPTY,
LATTR=WCHREG,
DNNO=1-1-345,
VCCYC=4;

( ADD-LDAT:100,ALL,1,,100,1,1,,1,EMPTY,WCHREG,1-1-345,4,,,,,,; )

6/16/2023 23/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

6.ADD-WABE:
CD=53301,
DAR=TIE,
CHECK=N;

( ADD-WABE:53301,,,TIE,N,,,,,,,,; )

7.ADD-LDPLN:
LDP=53301-X,
LROUTE=100,
LAUTH=1,
PINDP=N;

( ADD-LDPLN:53301-X,,100,,1,,,,N; )

STMA Creation (2nd card) :

1.ADD-BCSU:
MTYPE=PER,
LTG=1,
LTU=3,
SLOT=79,
PARTNO="Q2160-X",
FCTID=5,
LWVAR="0",
HWYBDL=A;

( ADD-BCSU:PER,1,3,79,"Q2160-X ",5,0,,,,,,A; )

2.ADD-BDAT:
LTG=1,
LTU=3,
SLOT=79,
TYPE=STMA,
OPMODE=NW20,
ATMADDR=920753201,
ATMNPI=NSAP,
L1MODE=SDH,
REASBUF=16,
ATMPROT=UNI40,
PATTERN=213,
SIGVPI=0,
=,
=,
=,
=,
=,
=,

6/16/2023 24/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

=,
=,
VPCI0=0
VPCI1=1
VPCI2=2
VPCI3=3
VPCI4=4
VPCI5=5
VPCI6=6
VPCI7=7;

( ADD-BDAT:1,3,79,STMA,NW20,920753201,NSAP,SDH,16,UNI40,213,0,,,,,,,,,0,1,2,3,4,5,6,7; )

3.ADD-BUEND:
TGRP=101,
NAME="STMA TEST",
NO=30,
RSV=N,
TRACENO=0,
ACDTHRH=*,
PRIONO=2,
TDDRFLAG=ON,
GDTRRULE=0,
ACDPMGRP=0,
CHARCON=NEUTRAL;

( ADD-BUEND:101,"STMA-TEST ",30,N,0,*,2,ON,0,0,NEUTRAL; )

4.ADD-TDCSU:
OPT=NEW,
PEN=1-3-79-1,
COTNO=1,
COPNO=1,
DPLN=0,
ITR=0,
COS=1,
LCOSV=1,
LCOSD=1,
CCT="STMA SVC",
=1
PROTVAR=ECMAV2,
SEGMENT=8,
=,
DEDSVC=NONE,
=,
=,
=,
TRTBL=GDTR,
SIDANI=N,
ATNTYP=TIE,

6/16/2023 25/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

CBMATTR=NONE,
TCHARG=N,
SUPPRESS=0,
=,
=,
=,
=,
=,
=,
TRACOUNT=31,
SATCOUNT=MANY,
NNO=1-1-345,
ALARMNO=0,
FIDX=1,
CARRIER=1,
ZONE=EMPTY,
COTX=1,
FWDX=1,
CHIMAP=N,
=,
=,
=,
=,
=,
UUSCCX=16,
UUSCCY=8,
FNIDX=1,
NWMUXTIM=10,
=,
CLASSMRK=EC&G711&G729OPT,
=,
TGRP=101,
SRCHMODE=ASC,
INS=Y,
DEV=ATMSVC,
BCHAN=1&&30,
BCNEG=N,
BCGR=1,
PERMACT1=Y,
PERMACT2=Y,
MASTER=N,
TEIVERIF=N,
AAL5TIM=65535,
ERRTIM=50,
FILLLEV=47,
ATMADDR=910153200,
ATMNPI=NSAP,
ADDREXT=45;

6/16/2023 26/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

( ADD-TDCSU:NEW,1-03-079-1,1,1,0,0,1,1,1,"STMA-SVC
",1,ECMAV2,8,,NONE,,,,GDTR,N,TIE,NONE,N,0,,,,,,,31,MANY,1-1-
345,0,1,1,EMPTY,1,1,N,,,,,,16,8,1,10,,EC&G711&G729OPT,"",101,ASC,Y,ATMSVC,1&&30,N,1,Y,
Y,N,N,65535,50,47,910153200,NSAP,45; )

Note: This command must be used as many times as many circuits required. But maximum circuits are
0 to 127.

5.ADD-RICHT:
MODE=LRTENEW,
LRTE=101,
LSVC=ALL,
NAME="STMA SVC",
TGRP=101,
DNNO=1-1-341,
YES
=,
=,
=,
=,
=,
=,
=,
DTMFCNV=FIX,
DTMFPULS=PP300,
DESTNO=1
=20,
=20,
ROUTATT=NO,
EMCYRTT=NO,
=,
PDNNO=10-10-502,
CHARCON=NEUTRAL,
=NO
CONFTONE=NO,
RERINGRP=NO;

( ADD-RICHT:LRTENEW,101,ALL,"STMA-SVC ",101,1-1-341,YES,,,,"",,,,20,20,NO,NO,"",10-
10-502,NEUTRAL,NO,NO,NO; )

6/16/2023 27/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5.ADD-LDAT:
LROUTE=101,
LSVC=ALL,
LVAL=1,
=,
TGRP=101,
ODR=1,
LAUTH=1,
=,
CARRIER=1,
ZONE=EMPTY,
LATTR=WCHREG,
DNNO=1-1-341,
VCCYC=4;

( ADD-LDAT:101,ALL,1,,101,1,1,,1,EMPTY,WCHREG,1-1-341,4,,,,,,; )

6.ADD-WABE:
CD=53302,
DAR=TIE,
CHECK=N;

( ADD-WABE:53302,,,TIE,N,,,,,,,,; )

7.ADD-LDPLN:
LDP=53302-X,
LROUTE=101,
LAUTH=1,
PINDP=N;

( ADD-LDPLN:53302-X,,101,,1,,,,N; )

6/16/2023 28/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

9. DIUN2 Creation (CAS-Decadic signaling).

To create subscribers the ADD-BCSU, ADD-BUEND, ADD-TACSU, ADD-RICHT, ADD-LDAT,


ADD-WABE, ADD-LDPLN commands to be given

1. ADD-BCSU:
MTYPE=DIU,
LTG=1,
LTU=1,
SLOT=79,
PARTNO="Q2196-X",
LWVAR="0",
LWPAR1=1,
FIDX1=1,
LWPAR2=1,
FIDX2=1,
FCTID=2,
HWYBDL=A;

( ADD-BCSU:DIU,1,1,79,"Q2196-X ",0,1,1,1,1,2,,,,,A; )

2. ADD-BUEND:
TGRP=27,
NAME="E1",
NO=4,
RSV=N,
TRACENO=0,
ACDTHRH=*,
PRIONO=11,
TDDRFLAG=ON,
GDTRRULE=0,
ACDPMGRP=0,
CHARCON=NEUTRAL;

( ADD-BUEND:27,"E1 ",4,N,0,*,1,ON,0,0,NEUTRAL; )

3. ADD-TACSU:
PEN=1-1-79-3,
COTNO=20,
COPNO=20,
DPLN=0,
ITR=0,
COS=1,
LCOSV=1,
LCOSD=1,
TGRP=27,
COFIDX=0,
CCT="PCM",
DESTNO=0,

6/16/2023 29/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

ALARMNO=2,
CARRIER=1,
ZONE=EMPTY,
LIN=0,
CIDDGTS=NONE,
CBMATTR=NONE,
CLASSMRK=EC&G711&G729OPT,
DITIDX=0,
TRTBL=GDTR,
RULEIDX=0,
INS=Y,
DEVTYPE=TC,
DEV=DIUCQ421,
MFCVAR=0,
SUPPRESS=0,
DGTCNT=0,
TESTNO=1,
CIRCIDX=10,
CDRINT=1,
CCTINFO=0,
DIALTYPE=DIP,
DIALVAR=0-0,
COEX=0;

( ADD-TACSU:1-1-79-3,,20,20,0,0,1,1,1,,27,0,"PCM
",0,,2,1,EMPTY,0,NONE,NONE,,EC&G711&G729OPT,"
",0,GDTR,0,,Y,TC,DIUCQ421,0,,0,0,1,10,1,0,DIP-DIP,0-0,0; )

4.ADD-RICHT:
MODE=LRTENEW,
LRTE=27,
LSVC=ALL,
NAME="TEST",
TGRP=27,
DNNO=1-1-10,
ROUTOPT=YES,
PLB=NO,
FWDBL=NO,
ROUTATT=NO,
EMCYRTT=NO,
PDNNO=0,
CHARCON=NEUTRAL,
CONFTONE=NO,
RERINGRP=NO;

( ADD-RICHT:LRTENEW,27,ALL,"TEST ",27,1-1-
10,YES,,,,"",,,,,,NO,NO,"",0,NEUTRAL,NO,NO,NO; )

6/16/2023 30/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5. ADD-LDAT:
LROUTE=27,
LSVC=ALL,
LVAL=1,
TGRP=27,
ODR=2,
LAUTH=1,
CARRIER=1,
ZONE=EMPTY,
LATTR=WCHREG,
VCCYC=4;

( ADD-LDAT:27,ALL,1,,27,2,1,,1,EMPTY,WCHREG,,4,,,,,,; )

6. ADD-WABE:
CD=61,
DAR=TIE,
CHECK=N;

( ADD-WABE:61,,,TIE,N,,,,,,,,; )

7. ADD-LDPLN:
LDP="61"-"W"-"Z",
LROUTE=27,
LAUTH=1,
PINDP=N;

(ADD-LDPLN: 61-X,,27,,1,,,,N; )

6/16/2023 31/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

10. DIUN2 Creation (CAS- MF Signaling)

To create subscribers the ADD-BCSU, ADD-BUEND, ADD-TACSU, ADD-RICHT, ADD-LDAT,


ADD-WABE, ADD-LDPLN commands to be given

1. ADD-BCSU:
MTYPE=DIU,
LTG=1,
LTU=2,
SLOT=79,
PARTNO="Q2196-X",
LWVAR="0",
LWPAR1=1,
FIDX1=1,
LWPAR2=1,
FIDX2=1,
FCTID=2,
HWYBDL=A;

( ADD-BCSU:DIU,1,2,79,"Q2196-X ",0,1,1,1,1,2,,,,,A; )

2. ADD-BUEND:
TGRP=54,
NAME="E1 MFC JALIPA",
NO=4,
RSV=N,
TRACENO=0,
ACDTHRH=*,
PRIONO=1,
TDDRFLAG=ON,
GDTRRULE=0,
ACDPMGRP=0,
CHARCON=NEUTRAL;

( ADD-BUEND:54,"E1 MFC JALIPA ",4,N,0,*,1,ON,0,0,NEUTRAL; )

3.ADD-TACSU:
PEN=1-2-79-37,
COTNO=30,
COPNO=30,
DPLN=0,
ITR=0,
COS=30,
LCOSV=1,
LCOSD=1,
TGRP=54,
COFIDX=0,
CCT="ASCONMFC",
DESTNO=3,

6/16/2023 32/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

NNO=1-1-3,
ALARMNO=2,
CARRIER=1,
ZONE=EMPTY,
LIN=0,
CIDDGTS=NONE,
CBMATTR=NONE,
CLASSMRK=EC&G711&G729OPT,
DITIDX=0,
TRTBL=GDTR,
RULEIDX=0,
INS=Y,
DEVTYPE=TC,
DEV=DIUCQ421,
MFCVAR=2,
SUPPRESS=0,
DGTCNT=0,
TESTNO=1,
CIRCIDX=30,
CDRINT=1,
CCTINFO=0,
DIALTYPE=MFC,
DIALVAR=0-0,
COEX=0;

( ADD-TACSU:1-2-79-37,,30,30,0,0,30,1,1,,54,0,"ASCONMFC ",3,1-1-
3,2,1,EMPTY,0,NONE,NONE,,EC&G711&G729OPT,"
",0,GDTR,0,,Y,TC,DIUCQ421,2,,0,0,1,30,1,0,MFC-MFC,0-0,0; )

4.ADD-RICHT:
MODE=LRTENEW,
LRTE=54,
LSVC=ALL,
NAME="MFC JALIPA ",
TGRP=54,
DNNO=1-1-13,
ROUTATT=NO,
EMCYRTT=NO,
PDNNO=0,
CHARCON=NEUTRAL,
CONFTONE=NO,
RERINGRP=NO;

( ADD-RICHT:LRTENEW,54,ALL,"MFC JALIPA ",54,1-1-


13,,,,,"",,,,,,NO,NO,"",0,NEUTRAL,NO,NO,NO; )

6/16/2023 33/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5. ADD-LDAT:
LROUTE=54,
LSVC=ALL,
LVAL=1,
TGRP=54,
ODR=2,
LAUTH=1,
CARRIER=1,
ZONE=EMPTY,
LATTR=WCHREG,
VCCYC=4;

( ADD-LDAT:54,ALL,1,,54,2,1,,1,EMPTY,WCHREG,,4,,,,,,; )

6. ADD-WABE:
CD=54,
DAR=TIE,
CHECK=N;

( ADD-WABE:54,,,TIE,N,,,,,,,,; )

7. ADD-LDPLN:
LDP="54-X",
LROUTE=54,
LAUTH=1,
PINDP=N;

( ADD-LDPLN:54-X,,54,,1,,,,N; )

6/16/2023 34/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

11. E1-PRI Creation :

ADD-BCSU:DIU,1,3,25,"Q2196-X ",0,,,,,1,,,,,A;

MASTER

1. ADD-BUEND:66,"E1-PRI(MASTER) ",30,N,0,*,2,ON,0,0,NEUTRAL;

2. CHA-LWPAR:
DIUS2,1,COPPER,S2,ON,Y(master),16,0,D5,10,10,N,Y,DF,N,0,255,Y,N,INDEP,"";

3. ADD-TDCSU:NEW,1-03-025-0,35,31,0,0,31,1,1,"E1-
PRI",0,ECMAV2,8,,NONE,,,,GDTR,N,TIE,NONE,N,0,,,,,,,31,MANY,1-1-
341,0,1,1,EMPTY,35,1,N,,,,,,16,8,1,10,,EC&G711&G729OPT,"",66,CIR,Y,S2CONN,1&&30,N,1,1,0,
0,0,0,0;

4. ADD-RICHT:LRTENEW,66,ALL,"E1-PRI ",66,
1-1-341,YES,,,,"",,,,,,NO,NO,"",0,NEUTRAL,NO,NO,NO;

5. ADD-LDAT:66,ALL,1,,66,1,1,,1,EMPTY,WCHREG,1-1-341,4,,,,,,;

6. ADD-WABE:66,,,TIE,N,,,,,,,,;

7. ADD-LDPLN:66-X,,66,,1,,,,N;

SLAVE

1. ADD-BUEND:67,"E1-PRI(SLAVE) ",30,N,0,*,2,ON,0,0,NEUTRAL;

2. CHA-LWPAR: DIUS2,2,COPPER,S2,ON,N(slave),16,0,D5,10,10,N,N,DF,N,0,255,N,N,INDEP,"";

3. ADD-TDCSU:NEW,1-03-025-1,35,31,0,0,31,1,1,"E1-
PRI",0,ECMAV2,8,,NONE,,,,GDTR,N,TIE,NONE,N,0,,,,,,,31,MANY, 1-1-
345,0,1,1,EMPTY,35,1,N,,,,,,16,8,1,10,,EC&G711&G729OPT,"",67,CIR,Y,S2CONN,1&&30,N,1,2,0,
0,0,0,0;

4. ADD-RICHT:LRTENEW,67,ALL,"E1-PRI ",67,
1-1-345,YES,,,,"",,,,,,NO,NO,"",0,NEUTRAL,NO,NO,NO;

5. ADD-LDAT:67,ALL,1,,67,1,1,,1,EMPTY,WCHREG,1-1-345,4,,,,,,;

6. ADD-WABE:67,,,TIE,N,,,,,,,,;

7. ADD-LDPLN:67-X,,67,,1,,,,N;

6/16/2023 35/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

12. CREATION OF HOTLINE

i. Local subscribers

1. ADD-HOTLN
TYPE = HOTDEST
HTLNIDX = 1
DEST = 2003
(ADD-HOTLN: HOTDEST, 1, 2003 ;)

2. ADD-HOTLN
TYPE = HOTDEST
HTLNIDX = 2
DEST = 2002
(ADD-HOTLN: HOTDEST, 2, 2002 ;)

3. CHA-SDAT
STNO = 2002
TYPE = DATA1
NNO =
CDRACC =
PUBNUM =
TON =
NPI =
SRCGRP =
CLASSMRK =
HOTIDX = 1
SVCDOM =
DELSVCDM =
(CHA-SDAT: 2002,DATA1,,,,,,,,1,,;)

4. CHA-SDAT
STNO = 2003
TYPE = DATA1
NNO =
CDRACC =
PUBNUM =
TON =
NPI =
SRCGRP =
CLASSMRK =
HOTIDX = 2
SVCDOM =
DELSVCDM =
(CHA-SDAT: 2003,DATA1,,,,,,,,2,,;)

6/16/2023 36/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

5. CHA-SDAT
STNO = 2003
TYPE = ATTRIBUT
AATTR=HOT;

6. CHA-SDAT
STNO = 2002
TYPE = ATTRIBUT
AATTR=HOT;

ii. Trunk hotline (E1(CAS)

1. ADD-HOTLN
TYPE = HOTDEST
HTLNIDX = 1
DEST = 612003
(ADD-HOTLN:HOTDEST,1,612003;)

2. ADD-HOTLN
TYPE = HOTDEST
HTLNIDX = 2
DEST = 612002
(ADD-HOTLN:HOTDEST,2,612002;)

3. CHA-SDAT
STNO = 2002
TYPE = DATA1
NNO =
CDRACC =
PUBNUM =
TON =
NPI =
SRCGRP =
CLASSMRK =
HOTIDX = 1
SVCDOM =
DELSVCDM =
(CHA-SDAT:2002,DATA1,,,,,,,,1,,;)

4. CHA-SDAT
STNO = 2003
TYPE = DATA1
NNO =
CDRACC =
PUBNUM =
TON =
NPI =
SRCGRP =
CLASSMRK =
6/16/2023 37/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
HOTIDX = 2
SVCDOM =
DELSVCDM =
(CHA-SDAT:2002,DATA1,,,,,,,,2,,;)

iii. Trunk Hotline- (E1 (CAS) Two Hipaths)

1. ADD-HOTLN
TYPE = HOTDEST
HTLNIDX = 1
DEST = 612003
(ADD-HOTLN:HOTDEST,1,612003;)

2. ADD-HOTLN
TYPE = HOTDEST
HTLNIDX = 2
DEST = 622002
(ADD-HOTLN:HOTDEST,2,622002;)

3. CHA-SDAT
STNO = 2002
TYPE = DATA1
NNO =
CDRACC =
PUBNUM =
TON =
NPI =
SRCGRP =
CLASSMRK =
HOTIDX = 1
SVCDOM =
DELSVCDM =
(CHA-SDAT:2002,DATA1,,,,,,,,1,,;)

4. CHA-SDAT
STNO = 2003
TYPE = DATA1
NNO =
CDRACC =
PUBNUM =
TON =
NPI =
SRCGRP =
CLASSMRK =
HOTIDX =2
SVCDOM =
DELSVCDM =
(CHA-SDAT:2003,DATA1,,,,,,,,2,,;)

6/16/2023 38/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
13. CREATION OF OVERRIDE:

1. CHA-FEASU: A, OVR;
2. CHA-FEASU: A, FRKN;
3. CHA-SDAT: 2002, ATTRIBUT, KNOVR,,;
4. CHA-SDAT: 2003, ATTRIBUT, KNOVR,,;
5. ADD-WABE: 24,,, KNOVR,,,,,,,,,;
6. CHA-ZAND: ALLDATA,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, yes,,,,;(optional)

Note: 24 code to be created in WABE to access the facility. This facility is only for analog phones.

14. CREATION OF CALL TRANSFER:

1. CHA-FEASU: A, XFBACALL;
2. ADD-WABE: 8,,, TRNSKY,N,,,,,,,,;

Note: 8 code to be created in WABE to access the facility.

15. CREATION OF CONFERENCE:

1. CHA-FEASU: A, VARCONF;
2. ADD-WABE: 11,,, CONF,N,,,,,,,,;

Note: 11 code to be created in WABE to access the facility.

16. CREATION OF CALL PICKUP:

1. CHA-FEASU: A, PU;
2. ADD-WABE: 23,,, PU,,,,,,,,,;
3. ADD-AUN: 1,, 2000&&2023,,,,,,,,,,,;

Note: 23 code to be created in WABE to access the facility.

17. CREATION OF USER GROUP:

1. ADD-LRNGZ:01, 01, 04;


2. CHA-FEASU:A,SPDC;
3. ADD-SCSU:2000&&2023,1-1-121-
2,ANATE,0,0,2,2,1,1,1,1,1,,0,0,0,,,VAR,,,,,YES,,NO,,,,0,DIR,YES,NO;

4. ADD-ZRNGZ:1,01,6001,0," ";
5. ADD-ZRNGZ:1,02,2002,0," ";
6. ADD-ZRNGZ:1,03,2003,0," ";
7. ADD-ZRNGZ:1,04,2005,0," ";
8. ADD-WABE:25,,,SPDC1,N,,,,,,,,;

6/16/2023 39/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
18. CREATION OF ALTERNATE ROUTE
1. ADD-RICHT
MODE = LRTEEXT
LRTE = 27
LSVC =
TGRP = 64
ADD-RICHT:LRTEEXT,27,,64;

(ADD-RICHT:LRTENEW,27,ALL,"TEST",27,1-1-
10,YES,,,,"",,,,,,NO,NO,"",0,NEUTRAL,NO,NO,NO;
ADD-RICHT:LRTEEXT,27,ALL,64;
ADD-RICHT:LRTEEXT,27,ALL,53;)

2. ADD-LDAT
LROUTE = 27
LSVC =
M40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERS
LVAL =
LVALNEW =
TGRP = 64
ODR = 2
LAUTH = 1
LSCHED =
CARRIER =
ZONE =
LATTR = ALTTGR
DNNO =
VCCYC =
CBMATTR =
SCCID =
FACILITY =
SVCVCE =
SVCNVCE =
LDSRT =
ADD-LDAT:27,,,,64,1,1,,,,WCHREG&ALTTGR,,,,,,,,;

( ADD-LDAT:27,ALL,1,,27,2,1,,1,EMPTY,WCHREG,,4,,,,,,;
ADD-LDAT:27,ALL,1,,64,2,1,,1,EMPTY,ALTTGR&WCHREG,,4,,,,,,;
ADD-LDAT:27,ALL,1,,53,2,1,,1,EMPTY,ALTTGR&WCHREG,,4,,,,,,; )

6/16/2023 40/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
19. CREATION OF PIN (Personal Identification Number)

1. ADD-PERSI
TYPE = STN
STNO = 2003
NAME = PIN
ORG =
PINC =
COSXCD =
PIN1 = 1010
PIN2 =
PIN3 =
PIN4 =
PIN5 =
PPIN10 =
PIN11 =
PIN12 =
PIN13 =
PIN14 =
PIN15 =
PININDIV =
CHARCON =
ADD-PERSI:STN,2003,PIN,,,,1010,,,,,,,,,,,,;

(ADD-PERSI:STN,2003,"PIN*",,"1010","1010","1010","1010","1010","1010",,,,,,,,YES,; )

2. ADD-WABE
CD = 13
DPLN =
CPS =
DAR = APIN1
CHECK =
CDDP =
CD2 =
CPS2 =
CDDP2 =
DESTNO =
ARN =
CFREMVAR =
CFREMSE =
ADD-WABE:13,,,APIN1,,,,,,,,,;

(ADD-WABE:13,,,APIN1,N,,,,,,,,; )
Note: Access code 13 to activate the PIN faclity.

6/16/2023 41/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
3. ADD-WABE
CD = 14
DPLN =
CPS =
DAR = DPIN
CHECK =
CDDP =
CD2 =
CPS2 =
CDDP2 =
DESTNO =
ARN =
CFREMVAR =
CFREMSE =
ADD-WABE:14,,,DPIN,,,,,,,,,;

(ADD-WABE:14,,,DPIN,N,,,,,,,,; )
Note: Access code 14 to deactivate the PIN facility.

6/16/2023 42/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
20. CREATION OF CALL FORWARDING

ADD-WABE
CD = *10
DPLN =
CPS =
DAR = AFWDEXIN
CHECK =
CDDP =
CD2 =
CPS2 =
CDDP2 =
DESTNO =
ARN =
CFREMVAR =
CFREMSE =
ADD-WABE:*10,,,AFWDEXIN,,,,,,,,,;

( ADD-WABE:*10,,,AFWDEXIN,N,,,,,,,,;) (Activation)

ADD-WABE
CD = #10
DPLN =
CPS =
DAR = DFWDVCE
CHECK =
CDDP =
CD2 =
CPS2 =
CDDP2 =
DESTNO =
ARN =
CFREMVAR =
CFREMSE =
ADD-WABE:#10,,,DFWDVC,,,,,,,,,;

( ADD-WABE:#10,,,DFWDVCE,N,,,,,,,,; ) (Deactivation)

6/16/2023 43/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
21. MALICIOUS CALL TRACE:

Below information is provided by Siemens (Mr. Antony)

Port-8 is configured by default which is dongle port. Please do not use this port if the optical isolator is
not installed.

ADD-LCSM:A1,ASYNC,2,4800,7,SL1,INT,INT; ( PORT-9)
ADD-LCSM:A1,ASYNC,3,4800,7,SL1,INT,INT; ( PORT- 10)

TO CONFIGURE PORT-10 AS RMX PORT.


ADD-BCSM:A1,DPP,10,Y;

ADD-ATCSM:A1,CFIG,TYPE,PT88,0D0A,0C,0,0,0,0,0,0,62,80;
ADD-ATCSM:A1,CFIG,TYPE,QUOSC,0D0A,0,0,0,0,1B4730,1B4731,03,22,80;
ADD-ATCSM:A1,CFIG,TYPE,QUOPT,0D0A,0C,0,1B60,1B61,0,0,0,62,80;
ADD-ATCSM:A1,CFIG,TYPE,QUSCAPT,0D0A,0,0,0,0,0,0,03,22,80;
ADD-ATCSM:A1,CFIG,TYPE,PCOSC,0D0A,0,0,0,0,1B5B306D,1B5B386D,03,17,80;
ADD-ATCSM:A1,CFIG,TYPE,PCOPT,0D0A,0C,0,1B60,1B61,0,0,0,62,80;
ADD-ATCSM:A1,CFIG,TYPE,PCSCAPT,0D0A,0C,0,1B40,1B41,1B5B306D,1B5B386D,03,62,80;
ADD-ATCSM:A1,CFIG,TYPE,RSV1,0D0A,0C,1B5B2470,0,0,0,0,0,26,80;
ADD-ATCSM:A1,CFIG,TYPE,RSV2,0D0A,0,0,0,0,1B4730,1B4731,03,22,80;
ADD-ATCSM:A1,CFIG,TYPE,RSV3,0D0A,0,0,0,0,1B5B306D,1B5B386D,03,17,80;
ADD-ATCSM:A1,CFIG,DEV,2,ECHO&ARCVCO,80,F8,1,04,00,00&00,00,0,02,0D,0D,0D&0A,65535,
65535,65535,600,120,300,600,120,C2C1C4C3,C2C1C4C3;
ADD-
ATCSM:A1,CFIG,DEV,3,ECHO&ARCVCO,80,F8,1,04,00,00&00,00,0,02,0D,0D,0D&0A,65535,65535,
65535,600,120,300,600,120,C2C1C4C3,C2C1C4C3;
ADD-ATCSM:A1,ADD,TYPE,CON2,Y,PCOSC,2;
ADD-ATCSM:A1,ADD,TYPE,CON3,Y,PCOSC,3;
ADD-ATCSM:A1,ADD,LN,2,9,N;
ADD-ATCSM:A1,ADD,LN,3,10,N;

ACTIVATE THE PORT-9 & 10 AFTER PROGRAMMING.


ACT-LSSM:A1,9;
ACT-LSSM:A1,10;

CHA-COSSU:COS, 1, TRACE;
CHA-FEASU:A, TRACE

REG- ASSGN:SATIC; (ROUTE THE TRACE TO PORT-10 ie CO3 AND CONNECT UNIX CABLE
AND CONNECT IT TO SERIAL PORT OF THE PC)

Note :

1. Based upon information given by Siemens, We (ITI) configured Malicious call trace by
executing the following commands.
2. Port-8 (On HUBC card with Dongle) used for RS-232 communication.
3. Port-9 (CCDAX back panel) used for CDR.

6/16/2023 44/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
4. Port-10 (CCDAX back panel) used for Malicious call trace.
5. Port-8 & 9 RS232 cable to be used between PC com port and System port.
6. Port-10 Unix cable to be used between PC com port and System port.

CHANGE-ASSGN:SATIC,DPT1,CO3;

If "TRACE" is set, it will display all the established calls.


To trace only "Malicious calls",
1. Set MCIDM in COSSU, and
2. Set access code in WABE.

1. CHA-FEASU
TYPE = a
CM = trace & tracco
CHA-FEASU: A, TRACE&TRACCO;

(For Local calls COS should be set, and for Trunk calls COS and COT should be set)

To change the COS of specified COS value of the particular card.

2. CHA-COSSU
TYPE = COS
COS = 1
AVCE = MCIDM
AFAX =
ADTE =
DVCE =
DFAX =
DDTE =
COEX =
INFO =
CHA-COSSU:COS,1,MCIDM,,,,,,,;

3. CHA-COSSU
TYPE = COS
COS = 2
AVCE = MCIDM
AFAX =
ADTE =
DVCE =
DFAX =
DDTE =
COEX =
INFO =
CHA-COSSU:COS,2,MCIDM,,,,,,,;

6/16/2023 45/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
4. CHA-COT
COTNO = 30
COTTYPE = COTADD
PAR = TRAI
DEV =
INFO =
CHA-COT:30,COTADD,TRAI,,;

5. ADD-WABE
CD = 22
DPLN =
CPS =
DAR = TRACE
CHECK =
CDDP =
CD2 =
CPS2 =
CDDP2 =
DESTNO =
ARN =
CFREMVAR =
CFREMSE =
ADD-WABE:22,,,TRACE,,,,,,,,,;

To trace "Malicious Call" in MF-Junction, MFC variant has to be set for the particular MF junction.

6/16/2023 46/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
For MFC Signaling

22. CONFIGURATION OF SIUX CARD : For Forward & Backward signaling

This board has 8 MFCR2 sender and 8 MFCR2 receiver. This equipments are only usable in pairs. The
signaling systems begins by sending the forward signaling (6 Forward & 2 Backward)

1. ADD-BCSU
MTYPE=SIUP
LTG=1
LTU=3
SLOT=19
PARTNO=Q2187-X
MFCTYPE=R2B&R2B&R2F&R2F&R2F&R2F&R2F&R2F
LWVAR=0
FCTID=3;

(Functional ID =3,
Backward =4,
Forward=4
MFPB is to be given
MFPF is to be given

After configuring the SIUX card, Reset the card by deactivating & activating the card by using the AMO
commands.
2. DEA-BSSU (Deactivate the card)
3. ACT-BSSU (Activate the card)
4. DIS_SDSU (To verify the SIUX board)

MFC

MFCTA (MFC table should be loaded from MO disk to Hard disk)

ADD-MFCTA
COPY-MFCTA:27,1 (Indian) MF variant of 27 is copied to 1
COPY-MFCTA:25,1 (International) MF variant of 25 is copied to 1
After copying the required MFC variant, the variant has to be configured as per the required parameters.

By using the display command, display the MFC trunk card parameters and check the MFCVAR is
specified.
In COT, check that the MFC is included.

For E1-CAS on MF dialing


COPY-PTIME=49,30;

CHA-PTIME : REST,30,LONG,,0,,0;
CHA-PTIME : REST,30,PARA,,,,0,8,1,120,7,0;
CHA-PTIME : REST,30,SHORT,,,,100,,,,8;
P1=2 & P3=0;

6/16/2023 47/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
Display of MFC variant –1 for Auto-Auto is shown below :

DIS-MFCTA
MFCVAR = 1
TYPE = ?
TYPE : BRANCH PARAMETER
CHARACTERISTIC : OPTIONAL CONDITIONAL
POSS. VALUES : HD DIRECTORY OF ALL POSSIBLE INITIALIZATIONS
ALL OUTPUT ALL MFC INFORMATION
TBLF MFC CONVERSION TABLE, FORWARD SIGNALS
TBLB MFC CONVERSION TABLE, BACKWARD SIGNALS
MFCVAR MFC VARIANT TABLE
TYPE = tblf
OPT = fident
DIS-MFCTA:1,TBLF,FIDENT;
H500: AMO MFCTA STARTED

MFCVAR: 1 MFCVARI: 27 TYPE=TBLF OPT=FIDENT

ID : 0000000 CNT: 7

PABXID : 1495 PCNT: 4

POS1: 0 POS2: 0 POS3: 0 POS4: 0

ANBEG: 0 ANEND: 0 APOS: 0

BSDIRNO: 14953111 BSDIRCNT: 8

FILLCHAR: 0

With this MFC variant, the malicious call trace for A/A the originating number is displayed as 4952003.
495 is the PABXID and 2003 is the Subscriber number.

6/16/2023 48/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

23. CALL DATA RECORD (CDR):

ADD-FTBL:13,B,FORM,1,N," #@/#@/#@@@ #@:#@:#@ #@@@ #@@@@ #@:#@:#@ #@@@


#@@@";
ADD-FTBL:13,B,FORM,2,N,"@@@@@@@@@@@@@ #@ #@";
ADD-FTBL:13,B,CTRL,3,N,CR;
ADD-FTBL:13,B,CTRL,4,Y,LF;
ADD-FTBL:13,B,FIELD,1,STDAY,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,2,STMONTH,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,3,STYEAR,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,4,STHOUR,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,5,STMIN,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,6,STSEC,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,7,TKNOLIST,CHAR," ",R;
ADD-FTBL:13,B,FIELD,8,CHRGEE,CHAR," ",L;
ADD-FTBL:13,B,FIELD,9,CONHOUR,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,10,CONMIN,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,11,CONSEC,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,12,ROUTCN,CHAR," ",R;
ADD-FTBL:13,B,FIELD,13,DESTPTY,CHAR," ",L;
ADD-FTBL:13,B,FIELD,14,CONNTYPE,CHAR,"0",R;
ADD-FTBL:13,B,FIELD,15,SUPLSERV,CHAR,"0",R;

ADD-FEACG:CDRATND&CDRCDUMP&CDRCDIS&CDRSPR;

ADD-SELG:SELG,1,N,DEV2,NODEV,1,0;
CHANGE-SELG:SELT,1,1,FORM13,NOFORM,NOCALC,A22;
CHANGE-SELG:SELT,1,1,,,,,0&&999999;
CHANGE-SELG:SELT,1,1,,,,,,VOICE&DTE ;
CHANGE-SELG:SELT,1,1,,,,,,,0&&15;
CHANGE-SELG:SELT,1,1,,,,,,,,ALL,ALL,Y,N,N,N,N,N,N,N,N,N,N,N,N,N,N,N,N;
CHANGE-SELG:SELT,1,1,,,,,,,,,,,,,,,,,,,,,,,,,,,0,000000;
CHANGE-SELG:SELT,1,1,,,,,,,,,,,,,,,,,,,,,,,,,,,,,0&&999,0&&254,0&&30;
CHANGE-SELG:SELT,1,1,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,N,N,INTERN&INCO&OUTG ,0&&8,0&&9,ALL;

ADD-GEZU:TTY,DEV2,TTY,TERM2;

ACT- SELS: 1;

CHA-FEASU:A,CDRINH;

CHA-COSSU:COS,1,CDRINT&CDRC,,;
CHA-COSSU:COS,2,CDRINT&CDRC,,;

Note: 1. CDR is dumped to terminal 2


2. Malicious call dumped to Terminal 3

6/16/2023 49/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

24. CREATION OF MULIPLE SUBSCRIBER NUMBER (MSN):

ADD-SBCSU:7000,MSN,6000,,1,2,1,2,1,1,0,N,0,0,,,Y,N,N,3,;

ADD-WABE: 7000,,, STN,N,,,,,,,,;

25. CARD RESET:

ACTIVATE-BSSU (T0 activate the board in particular slot)

DEACTIVATE-BSSU (To deactivate the board in particular slot)

26. DEVICE SWITCH OF SWITCHING UNIT :

ACTIVATE-DSSU (To activate the B-channels in the PRI/STMA etc.,)

DEACTIVATE-DSSU (To deactivate the B-channels in the PRI/STMA etc.,)

27. STATUS DISPLAY IN SWITCHING UNIT :


DISPLAY-SDSU : Displays the status of modules, trunks and timeslots.

28. UPDATING THE DATABASE IN THE SYSTEM :

EXEC_UPDAT:BP,ALL;

6/16/2023 50/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

DIAL PLAN
Trunk
Grp.No. Name Device Type LDPLN PEN

1 LD CONNECTION
7 TESTE-DIUN2 S2CONN 92-X 1-1-49-0 (30 channels)
8 TESTE-DIUN2 S2CONN 93-X 1-1-49-1 (30 channels)
11 E1-CAS -
21 EM&MFC EMCONT2 21-XXXX 1-2-115-0&&1
25 PCM1 DIUCQ421 1-1-79-2
26 PCM2 -
27 E1-Decadic DIUCQ421 61-X 1-1-79-3&&6
28 E1-Decadic DIUCQ421 62-X 1-1-79-35&&38
30 TMLR-Decadic TMLRUD 30-W-Z 1-1-85-0, 1-1-91-0, 1-1-97-0,
1-1-109-0
31 TMLR-Decadic TMLRUD 31-XXXXT 1-1-85-1, 1-1-91-1, 1-1-97-1,
1-1-109-1
32 TMLR-MFC TMLRUD 32-W-Z 1-3-31-0
33 TMLR-MFC TMLRUD 33-W-Z 1-3-31-1
40 TMEW2-Decadic EMCONT2 40-W-XXXX 1-1-103-0
41 TMEW2-Decadic EMCONT2 41-X 1-1-103-1
42 E&M_DTMF EMCONT2 42-X 1-3-49-0&&1
46 TMEW2-DTMF EMCONT2 46-W-Z 1-3-61-0&&1
51 E1-MF DIUCQ421 51-W-Z 1-2-79-1&&4 (Not working)
52 E1-MF DIUCQ421 52-W-Z 1-2-79-33&&36 (Not working)
53 E1 MFC JALIPA DIUCQ421 55-X 1-2-79-5&&8
54 E1 MFC JALIPA DIUCQ421 54-X 1-2-79-37&&40
64 E1-PRI (MASTER) S2CONN 64-X 1-1-25-0 (30 channels)
65 E1-PRI (SLAVE) S2CONN 65-X 1-1-25-1 (30 channels)
66 E1-PRI (MASTER) S2CONN 66-X 1-3-25-0 (30 channels)
67 E1-PRI (SLAVE) S2CONN 67-X 1-3-25-1 (30 channels)
100 STMA-TEST ATM SVC 53301-X 1-2-25-1 (30 channels)
101 STMA-TEST ATM SVC 53302-X 1-3-79-1 (30 Channels)
102 STMA-TEST ATM SVC 53303-X 1-2-25-2 (30 channels)
103 STMA-TEST ATM SVC 53304-X 1-3-79-2 (30 Channels)

Two Alternate Routes are provided for E1-MFC TGR.27 (1-1-79-3&&6)


1. First Alternate Route is E1-PRI TGR.64 (1-1-25-0)
2. Second Alternate Route is E1-MFC TGR.53 (1-2-79-5&&8)

6/16/2023 51/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
COLOR CODE DETAILS
SLMA24 (24 Circuits)
Pair no Wire Color Circuit no
WHT-BLU
1 BLU-WHT 0
WHT-ORG
2 ORG-WHT 1
WHT-GRN
3 GRN-WHT 2
WHT-BRN
4 BRN-WHT 3
WHT-SLT
5 SLT-WHT 4
RED-BLU
6 BLU-RED 5
RED-ORG
7 ORG-RED 6
RED-GRN
8 GRN-RED 7
RED-BRN
9 BRN-RED 8
RED-SLT
10 SLT-RED 9
BLK-BLU
11 BLU-BLK 10
BLK-ORG
12 ORG-BLK 11
BLK-GRN
13 GRN-BLK 12
BLK-BRN
14 BRN-BLK 13
BLK-SLT
15 SLT-BLK 14
YEL-BLU
16 BLU-YEL 15
YEL-ORG
17 ORG-YEL 16
YEL-GRN
18 GRN-YEL 17
YEL-BRN
19 BRN-YEL 18
YEL-SLT
20 SLT-YEL 19
VIO-BLU
21 BLU-VIO 20
VIO-ORG
22 ORG-VIO 21
VIO-GRN
23 GRN-VIO 22
VIO-BRN
24 BRN-VIO 23
VIO-SLT
25 SLT-VIO 24 (Not used)

6/16/2023 52/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

STMD2 ( 8 Circuits)
Pair no Wire Color Circuit no
WHT-BLU
1 BLU-WHT 0 (Rx)
WHT-ORG
2 ORG-WHT 0 (Tx)
WHT-GRN
3 GRN-WHT 1 (Rx)
WHT-BRN
4 BRN-WHT 1 (Tx)
WHT-SLT
5 SLT-WHT 2 (Rx)
RED-BLU
6 BLU-RED 2 (Tx)
RED-ORG
7 ORG-RED 3 (Rx)
RED-GRN
8 GRN-RED 3 (Tx)
RED-BRN
9 BRN-RED 4 (Rx)
RED-SLT
10 SLT-RED 4 (Tx)
BLK-BLU
11 BLU-BLK 5 (Rx)
BLK-ORG
12 ORG-BLK 5 (Tx)
BLK-GRN
13 GRN-BLK 6 (Rx)
BLK-BRN
14 BRN-BLK 6 (Tx)
BLK-SLT
15 SLT-BLK 7 (Rx)
YEL-BLU
16 BLU-YEL 7 (Tx)
YEL-ORG
17 ORG-YEL Not Used
YEL-GRN
18 GRN-YEL Not Used
YEL-BRN
19 BRN-YEL Not Used
YEL-SLT
20 SLT-YEL Not Used
VIO-BLU
21 BLU-VIO Not Used
VIO-ORG
22 ORG-VIO Not Used
VIO-GRN
23 GRN-VIO Not Used
VIO-BRN
24 BRN-VIO Not Used
VIO-SLT
25 SLT-VIO Not Used

6/16/2023 53/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

TMLR2 ( 2 Circuits)
Pair no Wire Color Circuit no
WHT-BLU
1 BLU-WHT 0
WHT-ORG
2 ORG-WHT Not Used
WHT-GRN
3 GRN-WHT 1
WHT-BRN
4 BRN-WHT Not Used
WHT-SLT
5 SLT-WHT Not Used
RED-BLU
6 BLU-RED Not Used
RED-ORG
7 ORG-RED Not Used
RED-GRN
8 GRN-RED Not Used
RED-BRN
9 BRN-RED Not Used
RED-SLT
10 SLT-RED Not Used
BLK-BLU
11 BLU-BLK Not Used
BLK-ORG
12 ORG-BLK Not Used
BLK-GRN
13 GRN-BLK Not Used
BLK-BRN
14 BRN-BLK Not Used
BLK-SLT
15 SLT-BLK Not Used
YEL-BLU
16 BLU-YEL Not Used
YEL-ORG
17 ORG-YEL Not Used
YEL-GRN
18 GRN-YEL Not Used
YEL-BRN
19 BRN-YEL Not Used
YEL-SLT
20 SLT-YEL Not Used
VIO-BLU
21 BLU-VIO Not Used
VIO-ORG
22 ORG-VIO Not Used
VIO-GRN
23 GRN-VIO Not Used
VIO-BRN
24 BRN-VIO Not Used
VIO-SLT
25 SLT-VIO Not Used

6/16/2023 54/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

TMEW2 ( 4 Circuits)
Pair no Wire Color Circuit no
WHT-BLU
1 BLU-WHT 0 (Rx)
WHT-ORG
2 ORG-WHT 1 (Rx)
WHT-GRN
3 GRN-WHT 2 (Rx)
WHT-BRN
4 BRN-WHT 3 (Rx)
WHT-SLT
5 SLT-WHT 0 (Tx)
RED-BLU
6 BLU-RED 1 (Tx)
RED-ORG
7 ORG-RED 2 (Tx)
RED-GRN
8 GRN-RED 3 (Tx)
RED-BRN 0 (E)
9 BRN-RED 0 (M)
RED-SLT 1 (E)
10 SLT-RED 1 (M)
BLK-BLU 2 (E)
11 BLU-BLK 2 (M)
BLK-ORG 3 (M)
12 ORG-BLK 3 (M)
BLK-GRN
13 GRN-BLK Earth
BLK-BRN
14 BRN-BLK Earth
BLK-SLT
15 SLT-BLK Earth
YEL-BLU
16 BLU-YEL Earth
YEL-ORG
17 ORG-YEL Not Used
YEL-GRN
18 GRN-YEL Not Used
YEL-BRN
19 BRN-YEL Not Used
YEL-SLT
20 SLT-YEL Not Used
VIO-BLU
21 BLU-VIO Not Used
VIO-ORG
22 ORG-VIO Not Used
VIO-GRN
23 GRN-VIO Not Used
VIO-BRN
24 BRN-VIO Not Used
VIO-SLT
25 SLT-VIO Not Used

6/16/2023 55/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

DIUN2
Pair no Wire Colour Circuit no
WHT-BLU
1 BLU-WHT 0 (Tx)
WHT-ORG
2 ORG-WHT 0 (Rx)

RS 232 Cable Pin Configuration

Sl.No Description 9 Pin Connector 25 Pin connector


1 Carrier Detect 1 8
2 Rx Data 2 3
3 Tx Data 3 2
4 DTR 4 20
5 System GND 5 7
6 DSR 6 6
7 RTS 7 4
8 CTS 8 5
9 Ring Indication 9 22

Note:
1. The RS232 cable is connected between HUBC card ( Port 8 in Hipath ) with Dongle Key ( 25 Pin
side) to PC com port ( 9 Pin side) for Configuration with ComWin.

2. The Same RS232 Cable Can be used for CDR out put display on PC .The cable is connected
between HUBC card (Port 9 in Hicom i.e Back side of Control Rack) ( 25 Pin side) to PC com
port ( 9 Pin side) for CDR Output with ComWin.

UNIX Cable Pin Configuration

Sl.No Description 9 Pin Connector 25 Pin connector


1 Carrier Detect 1 -----
2 Rx Data 2 2
3 Tx Data 3 3
4 DTR 4 6
5 System GND 5 7
6 DSR 6 20
7 RTS 7 5
8 CTS 8 4
9 Ring Indication 9 22

Note:
1. The Unix cable is connected between HUBC card (Port 10 in Hicom i.e Back side of Control Rack)
( 25 Pin side) to PC com port ( 9 Pin side) for Malicious Call Trace with ComWin.

6/16/2023 56/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

PC Communication with Hipath 4500

1. RS232 communication:

This is required for programming the system using ComWin. The Procedure is listed below.
a. Run ComWin software in PC
b. Double click the connection Icon.
c. Select the COM in the selection menu
d. Select the RMX/COM menu and press <Enter>
e. Select the appropriate COM port
f. Line:COM2
g. Transfer Rate:4800
h. Parity:even
i. Word Length: 7
j. Stop Bit:1 and Press <Connect>
k. Now connection with PC is established

Note: After Establishing the communication with RS232 , assign the Settings for LAN connection by
enter the IP Address of the Hipath system & TCP/IP settings of the LCT

1. Using the Comwin Configure the LAN port of HUBC card , assign the IP address: 192.0.2.3.
2. Configure the TCP/IP settings of the PC (Local Craft Terminal), assign IP address 192.0.2.9
and assign the subnet mask 255.255.0.0.
3. Now we can logon to the system by entering valid user ID “root” & password as “hicom”.

2. LAN communication:
a. Run ComWin software in PC
b. Double click the connection Icon.
c. Select the Direct in the selection menu
d. Select the FAMOS menu and press < Enter>
e. Host Name: 192.0.2.3
f. Remote port: 102
g. SRC Name:FAMOS2
h. DST Name: CCMSCNFG and Press< Connect>
i. Now connection with PC is established

6/16/2023 57/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

NEW E1-PRI CREATION: - MADE BY: - NK BALWINDER SINGH


STEP NO-1

<ADD-BCSU
MTYPE = DIU
LTG = 1
LTU = 7
SLOT = 79
PARTNO = Q2196-X
LWVAR = 0
LWPAR1 =
FIDX1 =
LWPAR2 =
FIDX2 =
FCTID = 1 NOTE:- 1 IS FOR PRI
ACTFC =
STERM =
LTERM =
PTERM =
HWYBDL = A;
ADD-BCSU:DIU,1,7,79,Q2196-X,0,,,,,1,,,,,A;
H500: AMO BCSU STARTED
H06: PARAMETER LWVAR WILL BE IGNORED, SIMILAR MODULE TYPE ALREADY ASSIGNED.
VARIANT CAN BE CHANGED USING AMO ZAND.
H01: BD 1.7 . 79 ASSIGNED

AMO-BCSU -111 BOARD CONFIGURATION, SWITCHING UNIT


ADD COMPLETED;

STEP NO-2

ADD-BUEND

<ADD-BUEND
TGRP = 492
NAME = PRI-TEST
NO = 30
RSV = N
TRACENO = 0
ACDTHRH = *
PRIONO = 2
TDDRFLAG = ON
GDTRRULE = 0
ACDPMGRP = 0
CHARCON = NEUTRAL;
ADD-BUEND:492,PRI-TEST,30,N,0,*,2,ON,0,0,NEUTRAL;
H500: AMO BUEND STARTED
H01: ADD TGRP 492 COMPLETED
AMO-BUEND-111 TRUNK GROUP
ADD COMPLETED;

6/16/2023 58/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
STEP NO-3

ADD-TDCSU

OPT = NEW
PEN = 1-5-79-0
COTNO = 111
COPNO = 111
DPLN = 0
ITR = 0
COS = 111
LCOSV = 1
LCOSD = 1
CCT = PRI-TEST
DESTNO = 0
PROTVAR = ECMAV2
SEGMENT = 8
DEDSCC =
DEDSVC = NONE
FACILITY =
DITIDX =
SRTIDX =
TRTBL = GDTR
SIDANI = N
ATNTYP = TIE
CBMATTR = NONE
TCHARG = N
SUPPRESS = 0
DGTPR =
ISDNIP =
ISDNNP =
PNPL2P =
PNPL1P =
PNPAC =
TRACOUNT = 31
SATCOUNT = MANY
NNO = 1-1-179
ALARMNO = 0
FIDX = 1
CARRIER = 1
ZONE = EMPTY
COTX = 111
FWDX = 1
CHIMAP = N
INIGHT =
DOMTYPE =
DOMAINNO =
TPROFNO =
CCHDL =
UUSCCX = 16
UUSCCY = 8
FNIDX = 1
NWMUXTIM = 10
SRCGRP =
CLASSMRK = EC&G711&G729OPT

6/16/2023 59/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
TCCID =
TGRP = 492
SRCHMODE = CIR
INS = Y
DEV = S2CONN
BCHAN = 1&&30 NOTE:- Required Channel in one PRI.
BCNEG = N
BCGR = 1
LWPAR = 1 NOTE: - FIRST DIS-LWPAR THEN FILLING THIS OPTION AS PER REQUIREMENT FOR
. MASTER/SLAVE

LWPP = 0
LWLT = 0
LWPS = 0
LWR1 = 0
LWR2 = 0
SVCDOM = ;
ADD-TDCSU:NEW,1-5-79-0,111,111,0,0,111,1,1,PRI-TEST,0,ECMAV2,8,,NONE,,,,GDTR,
N,TIE,NONE,N,0,,,,,,,31,MANY,1-1-179,0,1,1,EMPTY,111,1,N,,,,,,16,8,1,10,,
EC&G711&G729OPT,,492,CIR,Y,S2CONN,1&&30,N,1,1,0,0,0,0,0,;
H500: AMO TDCSU STARTED
H04: AT PEN 1-05-079-0 THE FOLLOWING B-CHANNELS HAVE BEEN NEWLY
ASSIGNED TO BCGR 1:
1 && 30

H16: TRUNK AT PEN 1-05-079-0 ENTERED WITH PRI=0 IN THE REFERENCE CLOCK TABLE
H17: CHECK THE AMOUNT OF DEVICE MEMORIES IN LTG 1 FOR D-CHANNEL
CONNECTIONS, OTHERWISE INTERNAL BLOCKINGS MAY OCCUR !
AMOUNT = (AMOUNT OF S0 TRUNKS)*4 + (AMOUNT OF S2 B-CHANNELS)*2
(ALLOCATION WITH AMO DIMSU, PARAMETER DTITMD)
H02: TRUNK RELEASED FOR CALL PROCESSING

AMO-TDCSU-111 DIGITAL TRUNKS


ADD COMPLETED;

DIS-LWPAR

INFOPAT =
FORMAT =
DEV =S2CONN
ULE
TYPE = DIUS2
BLNO = ;
DIS-LWPAR:,,,DIUS2,;
H500: AMO LWPAR STARTED
-----------------------------------------------------------------------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB
BLOCK: - 0 FOR SLAVE PRI
+-----------------------------------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = N DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD =N PERMACT = Y FCBAB = DFH |
| CDG = N FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |

6/16/2023 60/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
| DEV = INDEP |
| INFO = |
+---- --------------------------------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB
BLOCK: - 1 FOR MASTER PRI | +--------
-----------------------------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = Y DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD =Y PERMACT = Y FCBAB = DFH |
| CDG = N FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |
| DEV = S2CONN |
| INFO = E1PRI |

STEP NO-4

<ADD-RICHT
MODE = LRTENEW
LRTE = 492
LSVC = ALL
NAME = PRI-TEST
TGRP = 492
DNNO = 1-1-179
ROUTOPT = YES
REROUT =
DTMFCNV =
DTMFDISP =
DTMFTEXT =
DTMFPULS =
PLB =
FWDBL =
DESTNO =
PIN =
ROUTATT = NO
EMCYRTT = NO
INFO =
PDNNO = 10-10-179
CHARCON = NEUTRAL
CONFTONE = NO
RERINGRP = NO
NOPRCFWD = NO
NITO = ;
ADD-RICHT:LRTENEW,492,ALL,PRI-TEST,492,1-1-179,YES,,,,,,,,,,NO,NO,,10-10-179,
NEUTRAL,NO,NO,NO,;
H500: AMO RICHT STARTED

AMO-RICHT-111 TRUNK ROUTING


ADD COMPLETED;

STEP-NO-5
ADD-LDAT

6/16/2023 61/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
LROUTE = 492
LSVC = ALL
LVAL = 1
TGRP = 492
ODR = 2 NOTE; - FIRST DIS-ODR THEN FILLING THIS OPTION AS PER REQUIREMENT
LAUTH = 1
LSCHED =
CARRIER = 1
ZONE = EMPTY
LATTR = WCHREG
DNNO = 1-1-179
VCCYC = 4
CBMATTR =
SCCID =
FACILITY =
SVCVCE =
SVCNVCE =
LDSRT =
ADD-LDAT:492,ALL,1,,492,2,1,,1,EMPTY,WCHREG,1-1-179,4,,,,,,;
H500: AMO LDAT STARTED
H11: THE PARAMETER ZONE MUST BE CHECKED WITH AMO TTBL
H02: LRTEL 1 WAS SET UP FOR LROUTE 492 LSVC ALL WITH LVAL 1

AMO-LDAT -111 LCR-DIRECTIONS


ADD COMPLETED;
DIS-LODR;

DIS-LODR;
H500: AMO LODR STARTED
+-------------------------------------------------------+
| ODR POSITION CMD PARAMETER
+--------+----------------------------------------------+
| 1 | 1 ECHOALL | NOTE: - THIS ODR USE Only FOR E1-CAS MFC Signaling Type .
| | 2 END |
+--------+----------------------------------------------+
| ODR POSITION CMD PARAMETER
+--------+----------------------------------------------+
| 2 | 1 ECHO 2 |
| | 2 END | NOTE: - THIS ODR USE FOR E1PRI, E1-CAS DTMF TYPE& AES LD ONLY.

+--------+----------------------------------------------+
| | * = READY FOR USE BY AMO LDAT
+--------+----------------------------------------------+
| ODR POSITION CMD PARAMETER
+--------+----------------------------------------------+
| 5 * | 1 PAUSE 1 SEC |
| | 2 OUTPULSE 5406 NOTE: - THIS ODR USE FOR AES 406 COM-
CENTER
| | 3 ECHO 2 |
| | 4 END |
| +----------------------------------------------+
+--------+----------------------------------------------+
| ODR POSITION CMD PARAMETER
+--------+----------------------------------------------+
| 6 * | 1 PAUSE 2 SEC | NOTE: - THIS ODR USE FOR AES E1-PRI

6/16/2023 62/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
| | 2 OUTPULSE |
| | 3 ECHO 2 |
| | 4 END |
| +----------------------------------------------+

STEP NO-6

ADD-WABE

CD = 30441;
DAR = TIE
CHECK = ;
ADD-WABE:30441,,,TIE,;
H500: AMO WABE STARTED

AMO-WABE -111 DIALLING PLANS, FEATURE ACCESS CODES


ADD COMPLETED;
STEP NO 7
ADD-LDPLN

LDP = 30441-X NOTE: - FOR AES Z LETTER IS USED ONLY.


DPLN =
LROUTE = 492
LAUTH = 1
SPC =
FDSFIELD =
SDSFIELD =
PINDP = N
ADD-LDPLN: 30441-X,, 492,,1,,,,N;
H500: AMO LDPLN STARTED
H07: LDP HAS BEEN ADDED

AMO-LDPLN-111 ADMINISTRATION LCR DIALPLAN


ADD COMPLETED;

FOR AES LD: - COT, COP & COS PARAMETER

COP –

LINE WITH END-OF-DIAL EOD


LINE WITH ANSWERING ANS
LINE WITH SUPERVISION AND RELEASE ACKNOWLEDGEMENT LSUP
BACKWARD RELEASE AFTER RELEASE RLSA
DIALTONE ON INCOMING SEIZURE DTN
MAKE/BREAK RATIO (60/40) BR64
CO TRUNK CIRCUIT WILL BE USED AS TIE TRUNK TIE
END-OF-DIALING ANALYSED (INTERWORKING WITH GTD) EODA
PREDIALING DELAY 2 (AMO DTIM2: PDLY2) PDP2
INTERDIGIT PAUSE 2 (AMO DTIM2: IDGT2) IDP2

CO TRUNK ACCESS:
TRUNK ACCESS TA

TOLL ACCESS:

6/16/2023 63/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
TRUNK ACCESS TA

COT –

RECALL IF USER HANGS UP IN CONSULTATION CALL RCL


TRUNK CALL TRANSFER XFER
ATTENDANT INTERCEPT WHEN VACANT IVAC
ATTENDANT INTERCEPT WHEN UNAUTHORIZED INAU
TRUNK SIGNALING ANSWER ANS
CHANGEOVER FROM HOLD TO RING TONE CHRT
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
INTER-SYSTEM TRANSIT TIES ITT
SUPRESSION OF RECALLS TO AC RCLS
SEND NO NODE NUMBER TO PARTNER LWNC
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
USE DEFAULT NODE NUMBER OF LINE DFNN
CONTROLLED TRUNK AND LINE SELECTION CTLS
INTERNAL DIAL TONE DTNI

COS –

| TA | NOCO | NOCO |
| TNOTCR | NOTIE | NOTIE |
| CDRC | | |
| VCE | | |
I TRACE | | |

FOR E1-PRI : - COT , COP & COS PARAMETER

COP -

DUALTONE MULTIPLEFREQUENCY DTMF


LINE WITH SUPERVISION AND RELEASE ACKNOWLEDGEMENT LSUP
BACKWARD RELEASE AFTER RELEASE RLSA
REGISTRATION OF LAYER 3 ADVISORIES L3AR
MAKE/BREAK RATIO FOR DTMF 1 (PULSE=80MS,PAUSE=80MS) DTM1

CO TRUNK ACCESS:
TRUNK ACCESS TA

TOLL ACCESS:
TRUNK ACCESS TA

COT-

RECALL IF USER HANGS UP IN CONSULTATION CALL RCL


TRUNK CALL TRANSFER XFER
TRUNK SIGNALING ANSWER ANS
CHANGEOVER FROM HOLD TO RING TONE CHRT
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
NETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBN
NETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFN
NETWORKWIDE CALL FORWARDING PERMITTED FWDN
NETWORKWIDE FORWARDING NO-ANSWER FNAN
REGENERATED CO DIALTONE ON OUTGOING SEIZURE COTN

6/16/2023 64/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
REGISTRATION OF IMPLAUSIBLE EVENTS IEVT
END-OF-DIAL FOR BLOCK IS SET BLOC
EMERGENCY OVERRIDE/DISCONNECT VIA S0/S2 LINE PROV
SEND NO NODE NUMBER TO PARTNER LWNC
ACTIVATE TRANSIT COUNTER ADMINISTRATION FOR S0/S2 LINE ATRS
CONNECTION TO ROUTE OPTIMIZATION NODE ROPT
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
TSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCS
USE DEFAULT NODE NUMBER OF LINE DFNN
NO TONE NTON

COS –

| TA | NOCO | NOCO |
| TNOTCR | NOTIE | NOTIE |
| CDRC | | |
| VCE | | |
| MSN | | |
| TTT | | |

E1-CAS: - FOR MF SIGNALLING TYPE PARAMETER

COT-
RECALL IF USER HANGS UP IN CONSULTATION CALL RCL
TRUNK CALL TRANSFER XFER
ATTENDANT INTERCEPT WHEN DIALING INCOMPLETE IIDL
ATTENDANT INTERCEPT WHEN VACANT IVAC
ATTENDANT INTERCEPT WHEN UNAUTHORIZED INAU
ATTENDANT INTERCEPT WHEN DO-NOT-DISTURB IS ACTIVATED IDND
TRUNK SIGNALING ANSWER ANS
LINE WITH MFC SIGNALING MFC
CHANGEOVER FROM HOLD TO RING TONE CHRT
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
NETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBN
SEND NO NODE NUMBER TO PARTNER LWNC
CALL INTERCEPT IF NO DIGITS DIALED INDG
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
USE DEFAULT NODE NUMBER OF LINE DFNN
NO TONE NTON

COP –

LINE WITH END-OF-DIAL EOD


LINE WITH ANSWERING ANS
LINE WITH SUPERVISION AND RELEASE ACKNOWLEDGEMENT LSUP
LINE WITH FORWARD RELEASE ACKNOWLEDGEMENT ACKF
BACKWARD RELEASE AFTER RELEASE RLSA
DIALTONE ON INCOMING SEIZURE DTN
MAKE/BREAK RATIO (60/40) BR64
TIME DEPENDENT EXCHANGE DIALTONE TDED
NOT 1A, I.E OUTGOING DIGITS NOT WITHHELD NO1A

6/16/2023 65/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
CO TRUNK ACCESS:
TRUNK ACCESS TA

TOLL ACCESS:
TRUNK ACCESS TA

COS –

| TA | NOCO | NOCO |
| TNOTCR | NOTIE | NOTIE |
| CDRINT | TTT I TTT I
| CDRC | | |
| VCE | | |
| TRACE | | |
| CTLS | | |
| TTT | | |

LD FOR TIDEX EXCH (DECADIC SIGNALLING) PARAMETERS

COT: -

RECALL IF USER HANGS UP IN CONSULTATION CALL RCL


TRUNK CALL TRANSFER XFER
TRUNK SIGNALING ANSWER ANS
CHANGEOVER FROM HOLD TO RING TONE CHRT
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
SEND NO NODE NUMBER TO PARTNER LWNC
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
USE DEFAULT NODE NUMBER OF LINE DFNN
EXTERNAL DIAL TONE DTNE

COP: -

LINE WITH END-OF-DIAL EOD


LINE WITH SUPERVISION AND RELEASE ACKNOWLEDGEMENT LSUP
BACKWARD RELEASE AFTER RELEASE RLSA
DIALTONE ON INCOMING SEIZURE DTN
MAKE/BREAK RATIO (60/40) BR64
CO TRUNK CIRCUIT WILL BE USED AS TIE TRUNK TIE
END-OF-DIALING ANALYSED (INTERWORKING WITH GTD) EODA
PREDIALING DELAY 2 (AMO DTIM2: PDLY2) PDP2
INTERDIGIT PAUSE 2 (AMO DTIM2: IDGT2) IDP2

CO TRUNK ACCESS:
TRUNK ACCESS TA

TOLL ACCESS:
TRUNK ACCESS TA

6/16/2023 66/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,

COS: -

| TA | NOCO | NOCO |
| TNOTCR | NOTIE | NOTIE |
| CDRC | | |
| VCE | | |
| MSN | | |
| TTT | | |

TO CREATE AES-LD PARAMETERS

ADD-BCSU:-

MTYPE = PER
LTG = 1
LTU = 3
SLOT = 109
PARTNO = Q2064-X100
FCTID = 0
LWVAR = 0
CIRCNT =
ACTFC =
STERM =
LTERM =
PTERM =
HWYBDL = A;
ADD-BCSU:PER,1,3,109,Q2064-X100,0,0,,,,,,A;
H500: AMO BCSU STARTED
H06: PARAMETER LWVAR WILL BE IGNORED, SIMILAR MODULE TYPE ALREADY ASSIGNED.
VARIANT CAN BE CHANGED USING AMO ZAND.
H01: BD 1.3 .109 ASSIGNED

AMO-BCSU -111 BOARD CONFIGURATION, SWITCHING UNIT


ADD COMPLETED;
DIS-BCSU:-

TYPE = TBL
LTG = 1
LTU = 3
SLOT = 109
DIS-BCSU:TBL,1,3,109;
H500: AMO BCSU STARTED

ADDRESS : LTG 1 LTU 3 SOURCE GROUP 1


-----+-----------+---------+---+---+-+------------+-----+--------+------------+
| ASSIGNED | MODULE |FCT|HWY| | INSERTED | | | MODULE |
PEN | MODULE | TYPE |ID |BDL| | MODULE |STATE| HW-INFO| STATUS |
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
109 | Q2064-X100 TMLR A | | Q2064-X100 | 1 | B008-D | READY |

AMO-BCSU -111 BOARD CONFIGURATION, SWITCHING UNIT


DISPLAY COMPLETED;

6/16/2023 67/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
ADD-BUEND :-

TGRP = 506
NAME = 10 CSR
NO = 02
RSV = N
TRACENO = 0
ACDTHRH = *
PRIONO = 2
TDDRFLAG = ON
GDTRRULE = 0
ACDPMGRP = 0
CHARCON = NEUTRAL
ADD-BUEND:506,10 CSR,02,N,0,*,2,ON,0,0,NEUTRAL;
H500: AMO BUEND STARTED
H01: ADD TGRP 506 COMPLETED

AMO-BUEND-111 TRUNK GROUP


ADD COMPLETED;

ADD-TACSU:-

PEN = 1-3-109-0
NO = 2 NOTE: - Required channels fill-up
COTNO = 222
COPNO = 222
DPLN = 0
ITR = 0
COS = 222
LCOSV = 1
LCOSD = 1
INIGHT =
TGRP = 506
COFIDX = 0
CCT = 10 CSR CCM
DESTNO = 0
NNO = 1-1-179
ALARMNO = 0
CARRIER = 1
ZONE = EMPTY
LIN = 0
CIDDGTS = NONE
CBMATTR = NONE
SRCGRP =
CLASSMRK = EC&G711*G729OPT
M33: VALUE TYPE DOES NOT CORRESPOND TO TYPE IN VALUE TABLE
CLASSMRK = EC&G711&G729OPT
TCCID =
DITIDX = 0
TRTBL = GDTR
RULEIDX = 0
ATNTYP =
INS = Y
DEVTYPE = TC
DEV = TMLRUD
MFCVAR = 0

6/16/2023 68/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
DGTPR =
SUPPRESS = 1 NOTE :- THIS IS IMPORTANT OPTION FOR AES LD
DGTCNT = 1 NOTE :- THIS IS IMPORTANT OPTION FOR AES LD
TESTNO = 1 NOTE :- THIS IS IMPORTANT OPTION FOR AES LD
CIRCIDX = 0
CDRINT = 1
CCTINFO = 0
DIALTYPE = DIP-DIP
DIALVAR = 0-0
COEX = 0
ADD-TACSU:1-3-109-0,2,222,222,0,0,222,1,1,,506,0,10 CSR CCM,0,1-1-179,0,1,
EMPTY,0,NONE,NONE,,EC&G711&G729OPT,,0,GDTR,0,,Y,TC,TMLRUD,0,,1,1,1,0,1,0,
DIP-DIP,0-0,0;
H500: AMO TACSU STARTED
H01: TRUNK 10 CSR CCM ASSIGNED AT PEN 1-3-109-0
H02: TRUNK RELEASED FOR CALL PROCESSING
H01: TRUNK 10 CSR CCM ASSIGNED AT PEN 1-3-115-1
H02: TRUNK RELEASED FOR CALL PROCESSING

AMO-TACSU-111 CONFIGURATION OF ANALOG TRUNK CIRCUITS IN THE SWU


ADD COMPLETED;

ADD-RICHT :-

MODE = LRTENEW
LRTE = 506
LSVC = ALL
NAME = 10 CSR CCM
TGRP = 506
DNNO = 1-1-179
ROUTOPT = YES
REROUT = YES
DTMFCNV = FIX
DTMFDISP = WITHOUT
DTMFTEXT =
DTMFPULS =
PLB = NO
FWDBL = NO
DESTNO =
PIN =
ROUTATT =
EMCYRTT = NO
INFO =
PDNNO = 10-10-179
CHARCON =
CONFTONE =
RERINGRP =
NOPRCFWD =
NITO = NO
H500: AMO RICHT STARTED

AMO-RICHT-111 TRUNK ROUTING


ADD COMPLETED;

6/16/2023 69/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
DIS-RICHT :-

MODE = LRTE
LRTE = 506
LSVC = ALL;
DIS-RICHT:LRTE,506,ALL;
H500: AMO RICHT STARTED
+------------------------------------------------------------------------------------------------------+
| LRTE = 506 NAME = 10CSRCCM (NEUTRAL) LSVC = ALL |
| DNNO =1 -1 -179 PDNNO =10-10 -179 PIN =N |
| ROUTOPT = YES REROUT = YES PLB = NO FWDBL = NO |
| DTMFCNV = FIX DTMFDSP = WITHOUT DTMFTEXT = |
| DTMFPULS = PP300 BUGS = LIN ROUTATT = NO MAINGRP = 93 |
| EMCYRTT = NO CONFTONE = NO RERINGRP = NO RTENO = 93 |
| INFO = |
| NOPRCFWD = NO |
| NITO = NO |
+-----------------------------------------------------------------------------------------------------+
| TGRP = 506 10 CSR (NEUTRAL) SUBGROUP = 82 |
+-----------------------------------------------------------------------------------------------------+

AMO-RICHT-111 TRUNK ROUTING


DISPLAY COMPLETED;

ADD-WABE :-

CD-80400
DAR-TIE
CHECK-N;
ADD- COMPLETED

DIS-LODR :-

ODR = 10;
DIS-LODR,10:;
H500: AMO LODR STARTED

---------------------------------------------------------------
- 10 * | 1 PAUSE 1 SEC |
| | 2 OUTPULSE 5400 | NOTE :- THIS ALL 4 STEP,s SAME SENIORITY NOT
| | 3 ECHO 2 | INTERCHANGE
| | 4 END |
| +----------------------------------------------------+
| | * = READY FOR USE BY AMO LDAT |
+--------+----------------------------------------------+
| ODR POSITION CMD PARAMETER |
+--------+----------------------------------------------+

AMO-LODR -111 ADMINISTRATION OF LCR OUTDIAL RULES


DISPLAY COMPLETED;

ADD-LDAT :-

LROUTE = 506
LSVC = ALL
M40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERS
LVAL = 1
TGRP = 506

6/16/2023 70/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
ODR = 10 NOTE :- THIS OPTION IS VERY IMPORTANT
LAUTH = 1
LSCHED =
CARRIER = 1
ZONE = EMPTY
LATTR = WCHREG
DNNO = 1-1-179
VCCYC =
CBMATTR =
SCCID =
FACILITY =
SVCVCE =
SVCNVCE =
LDSRT =
ADD-LDAT:506,ALL,1,,506,10,1,,1,EMPTY,WCHREG,1-1-179,,,,,,,;
H500: AMO LDAT STARTED
H11: THE PARAMETER ZONE MUST BE CHECKED WITH AMO TTBL
H02: LRTEL 1 WAS SET UP FOR LROUTE 506 LSVC ALL WITH LVAL 1

AMO-LDAT -111 LCR-DIRECTIONS


ADD COMPLETED;
ADD-LDPLN :-
LDP = 80400-Z
DPLN = 0
M40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERS
LROUTE = 506
LAUTH = 1
SPC =
FDSFIELD =
SDSFIELD =
PINDP = N
ADD-LDPLN:80400-Z,0,506,,1,,,,N;
H500: AMO LDPLN STARTED
H07: LDP HAS BEEN ADDED
FOR DPLN 0

AMO-LDPLN-111 ADMINISTRATION LCR DIALPLAN


ADD COMPLETED;

TO CREATE SL-200 OF HIPATH


<sta-uw7
IPADDR =
PORT =
STA-UW7:,;
H500: AMO UW7 STARTED
login: *engr
Password: *hic*300
Open UNIX 8.0.0
server
Copyright (c) 1976-2001 Caldera International, Inc. and its suppliers.
All Rights Reserved.

RESTRICTED RIGHTS LEGEND:

When licensed to a U.S., State, or Local Government, all Software


produced by Caldera International is commercial computer software as
defined in FAR 12.212, and has been developed exclusively at private
expense. All technical data, or Caldera International commercial
computer software/documentation is subject to the provisions of
FAR 12.211 - "Technical Data", and FAR 12.212 - "Computer Software"
respectively, or clauses providing Caldera International equivalent
protections in DFARS or other agency specific regulations.

6/16/2023 71/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
Manufacturer: Caldera International, Inc.,
240 West Center Street, Orem, UT 84057.

Last login: Thu Apr 9 12:18:43 2009 on pts001

You have mail


# *
CMDLINE = opt/pal/bin/lan
Found:

BoardNo: Description
1 AMD PCnet family mdi driver PCI (1,0,0x1022,0x2000,0x0002) ENABLED

Which board do want to work with? (1-1, q) *1


Working with board:
AMD PCnet family mdi driver PCI (1,0,0x1022,0x2000,0x0002)
Actual Configuration:
IP Netmask Broadcast MACaddress
139.18.154.57 255.255.255.248 139.18.154.63 08:00:06:83:12:29

1 Configure LAN Interface


2 Modify LAN Interface
3 Deconfigure
4 Enable
5 Disable
6 Get State
7 Get Statistics
8 Get Tranceiver-Type

q Main Menu

Please select: *3
Are you sure ? (y/n/q) *y
Deconfiguring Netcard...
LAN interface successfully deconfigured
Press Enter
*
CMDLINE = opt/pal/bin/lan
Found:

BoardNo: Description
1 AMD PCnet family mdi driver PCI (1,0,0x1022,0x2000,0x0002) UNCONFIGURED

Which board do want to work with? (1-1, q) *1


Working with board:
AMD PCnet family mdi driver PCI (1,0,0x1022,0x2000,0x0002)
NetCard is UNCONFIGURED !!!!

1 Configure LAN Interface


2 Modify LAN Interface
3 Deconfigure
4 Enable
5 Disable
6 Get State
7 Get Statistics
8 Get Tranceiver-Type

q Main Menu

Please select: *1
Please enter IPaddress: *139.18.154.57
Assume Netmask: 255.255.0.0
Assume Broadcast: 139.18.255.255
OK ? (y/n/q) *n

6/16/2023 72/73
Hipath 4500 System Commands Switching R&D, ITI LTD.,
Please enter Netmask: *255.255.255.248
Please enter Broadcast: *139.18.154.63
OK ? (y/n/q) *y
Select Tranceiver-Type:
1. TP

Please select: *
CMDLINE = o
Configuring LAN card
*
CMDLINE = opt/pal/bin/lan
LAN interface successfully configured
Press Enter

Working with board:


AMD PCnet family mdi driver PCI (1,0,0x1022,0x2000,0x0002)
Actual Configuration:
IP Netmask Broadcast MACaddress
139.18.154.57 255.255.255.248 139.18.154.63 08:00:06:83:12:29

1 Configure LAN Interface


2 Modify LAN Interface
3 Deconfigure
4 Enable
5 Disable
6 Get State
7 Get Statistics
8 Get Tranceiver-Type

q Main Menu

6/16/2023 73/73

You might also like