1. When skinning a small wire, the insulation should be “pencil down” rather than cut square to

d. Decrease danger of nicking the wire

2. What type of hand tools commonly used in boring of ½ diameter hole in a panel board?

c. Knockout puncher and adjustable wrench

3. The technical term for the type THW wires should mostly is industrial wiring is

b. Moisture and heat resistant thermoplastic

4. What do you call a fitting resembling a pipe with a removable cover across access to electric
conduit?

b. Condulet

5. An electrician should always have his tools in conditions, the most important reason is

d. Defective tools can cause accidents or damage to equipment

6. Why is it necessary to use torque wrench in tightening bolted joints of Copper bus bars inside
bus ducts and bus ways?

c. To make sure the joints are well tightened

7. What will you do if the load schedule reflects a 20AT/2.0 sq. mm. Lighting branch circuit of
which circuit breakers over rated?

d. Change rating to 15AT to confirm with PEC requirement

8. Which of the following is an output device?

d. Magnetic Lock

9. Before adding to or altering an installation, you must ensure that

c. Safety precaution are followed

10. The selection requirements for Breaker are

c. Kilo Ampere Interrupting Capacity, Ampere Trip And Ampere Frame

11. Part of the auxiliary system that set the motion-trigger action individually for each camera

d. Motion detection

12. The material used in long length bus bar joints to give allowance for thermal expansion is

c. Flexible braided copper plates


13. It is a condition of operation of equipment excess of normal, full load rating, or of a conductor in
excess of rated ampacity that when it persists for a sufficient length of time would cause
damage or dangerous overheating.

b. Overload

14. An output device in CCTV

c. Monitor

15. An input device/s in Fire Detection Alarm System

a. Heat, smoke detector and MCP

16. It is an over current protective device which opens (breaks) when there is an overcurrent in the
circuit.

b. Fuse

17. Classification of wire with high-heat resistant

c. THHN

18. An Output Device in FDAS

c. Alarm Bell

19. A Charging system producing 14.5 Volts with a current flow of 43.5 Amps, what is the circuit
resistance?

a. 0.33 amps

20. An outlet that supplies power for lamp and other plug-in devices

a. Receptacles

21. Type of switch used to control a single bulb in two locations.

c. SPDT

22. Type of switch used to control a single bulb in a single location.

a. SPST

23. A unit of measurement which describes the amount of electric current passing a certain point at
a particular time.

d. Ampere

24. The unit of measurement use to express resistance.

a. Ohm

25. A unit of measurement of electrical pressure or voltage.


d. Volt

26. An instrument specially designed for measuring voltage.

c. Voltmeter

27. An electrical device used to record the amount of electrical energy consumed by an appliance or
electrical system in a particular period of time.

a. Electric Meter

28. Classification of wire with high-heat resistant is

c. THHN

29. Standard size of wire used for service entrance is

a. #8 AWG wire

30. Is a circuit conductor that carries current in normal operation, which is connected to ground (or
earth).

c. Neutral