Advanced Technical Information

CAY, PNM
1701 8700
Binder – 8 – Air Conditioning
8
PHEV AC Shut Off Valves Diagnosis

Vehicle Type: Cayenne S E-Hybrid, Panamera S E-Hybrid

Model Year: 2015 - 2017

Information: Diagnosis information for the air conditioning chiller and evaporator shut off valves.

Symptom: No cooling in the passenger compartment.


NOTE: A low state of charge of the High Voltage Battery can cause the AC to be deactivated until the
state of charge increases to an adequate level. Customers who do not plug their vehicle in on a regu-
lar basis may have this issue.

There are two shut off valves in the refrigeration circuit.


1. The chiller shut off valve is normally open and requires 12V be applied to it from the AC control unit
to close it. This would stop cooling of the high voltage battery.
a. Power and ground from the AC CU can be checked at the connector of the valve.
2. The evaporator shut off valve is normally closed and requires 12V to be applied to it, via a relay, in
order for the valve to open and provide cooling to the passenger compartment.
a. The evaporator shut off valve can be diagnosed easily by removing the relay and jump-
ing the load contacts of the relay to see if power makes it to the valve. Power at the
valve opens it and the evaporator gets cold with normal AC operation.
b. The relay winding circuit can be tested for power and ground from the AC CU.

Refer to the diagrams on the following pages.

February 20, 2017


©2017 Porsche Cars North America, Inc.
AfterSales Page 1 of 4
8 8700
CAY, PNM
1701
Advanced Technical Information

AC Control Unit
Actuates the Evaporator shut off valve via a relay.
The valve is closed without 12V from the relay.

High
Pressure Evaporator Shut Off Valve Relay
Sensor High Pressure
service port
Evaporator
High Pressure
Shut off
service port
Valve

Compressor T T
Chiller X X Evaporator
V V

Internal Heat Exchanger

AC Control Unit Low Pressure


Directly applies power and ground for the chiller shut off valve. Service Port
Valve is open without 12V applied from AC CU.

February 20, 2017


AfterSales
©2017 Porsche Cars North America, Inc.
Page 2 of 4
Advanced Technical Information
CAY, PNM
1701 8700 8

E4 A6
AC Control Unit

February 20, 2017


©2017 Porsche Cars North America, Inc.
AfterSales Page 3 of 4
8 8700
CAY, PNM
1701
Advanced Technical Information

The Evaporator Shut Off Valve Relay is in the location shown below in position 6.

Dealership
Distribution Service Manager ________ Shop Foreman ________ Service Technician ________ ________ ________ ________
Routing Asst. Manager ________ Warranty Admin. ________ Service Technician ________ ________ ________ ________

Dr. Ing. h.c. F. Porsche AG is the owner of numerous trademarks, both registered and unregistered, including without limitation the Porsche Crest®, Porsche®, Boxster®, Carrera®, Cayenne®, Cayman®,
Macan®, Panamera®, Speedster®, Spyder®, Tiptronic®, VarioCam®, PCM®, PDK®, 911®, RS®, 4S®, 718®, 918 Spyder®, FOUR UNCOMPROMISED®, and the model numbers and distinctive shapes of
the Porsche automobiles such as, the federally registered 911 and Boxster automobiles. The third party trademarks contained herein are the properties of their respective owners. Porsche Cars North America,
Inc. believes the specifications to be correct at the time of printing. However, specifications, standard equipment and options are subject to change without notice. Some options may be unavailable when a car
is built. Some vehicles may be shown with non-U.S. equipment. Please ask your authorized Porsche dealer for advice concerning the current availability of options and verify the optional equipment that you
ordered. Porsche recommends seat belt usage and observance of traffic laws at all times.

February 20, 2017


AfterSales
©2017 Porsche Cars North America, Inc.
Page 4 of 4