LINEA DE AIRE ACONDICIONADO LG INVERTER R410A

TECHO 380V - 60K - FRIO-CALOR / CEILING SUSPEND HEAT PUMP

Model Name AV-W60LM2S0


Indoor Unit AVNW60LM2S0
Outdoor Unit AVUW60LM2S0

Indoor unit AVNW60LM2S0

Power Supply V ,Ø, Hz 220-240 / 1 / 50-60

Casing Color - Morning Fog


WxHxD mm 1,600 × 235 × 690
Dimensions Body
WxHxD inch 63-1/4 × 9-1/4 × 27-5/32
Net Weight Body kg (lbs) 35 (77.2)
Row x Column x Fins per inch - (3 x 18 x 18) x 1
Heat Exchanger
Face Area m 2 (ft2) 0.46(4.95)
Type - CFF
Fan H/M/L m 3/min 30/ 25 / 20
Air Flow Rate
H/M/L ft3/min 1,059 / 882.5 / 706
Type - BLDC
Fan Motor Power Input W x No. 145.7 x 1
Running Current A 0.47
Output W x No. 125
Dehumidification Rate ℓ/h (pts/h) 6.5(13.8)
Sound Pressure Level Cooling H/M/L dB(A) 50 / 46 / 42
Liquid mm(inch) Ø 9.52 (3/8)
Piping
Gas mm(inch) Ø 15.88 (5/8)
Connections
Drain (O.D. / I.D.) mm Ø 21.5/ Ø 16.0
- Fuse
Safety Devices Overheart protection/ Overcurrent
-
protection
Power and Communication Cable (included Earth) No. x mm 2 (AWG) 4C x 0.75 (18)

Outdoor unit AVUW60LM2S0


Rated kW 16.1
Cooling
Rated Btu/h 55,000
Capacity
Rated kW 17
Heating
Rated Btu/h 58,000
Cooling Rated kW 5.28
Power Input
Heating Rated kW 5.00
Cooling Rated A 8.4
Running Current
Heating Rated A 7.4
Power Supply V , Ø , Hz 380-415 ,3 ,50-60
Cooling Max. A -
Starting Current
Heating Max. A -
Wiring Connections Power Supply Cable (included Earth) No. x mm² (AWG) 5C x 2.5 (14)
Casing Color - Warm Gray
WxHxD mm 950 × 1,380 × 330
Dimensions
WxHxD inch 37-13/32 × 54-11/32 × 13
Net Weight kg (lbs) 90.0 (198.4)
Type - Twin Rotary
Model Model x No. QPT442MAB x 1
Compressor
Motor type - BLDC
Motor Output W x No. 4,000 x 1
Type - R410A
Precharged Amount g (oz) 3,400 (119.9)
Refrigerant Chargeless-Pipe Length m (ft) 7.5 (24.6)
Additional Charging Volume g/m (oz/ft) 40 (0.43)
Control - Electronic Expansion Valve
Type - FVC68D
Refrigerant Oil
Charged volume cc x No. 1,300 x 1
#1_(Row x Column x Fins per inch) x No. - (2 x 32 x 14) x 2
Heat Exchanger
#2_(Row x Column x Fins per inch) x No. - -
Type - Propeller
Fan
Air Flow Rate m 3/min x No. 55 x 2
Type BLDC
Fan Motor
Output W x No. 124.6 x 2
Cooling Rated dB(A) 60
Sound Pressure Level
Heating Rated dB(A) 63
Sound Power Level Max. dB(A) -
Liquid Outer Dia. mm(inch) Ø 9.52 (3/8)
Piping Connections
Gas Outer Dia. mm(inch) Ø 15.88 (5/8)
Piping Length Max. m (ft) 75 (246.1)
Maximum Height Difference Outdoor Unit ~ Indoor Unit Max. m (ft) 30 (98.4)
Operation Range Cooling Min. ~ Max. ℃ DB (℉ DB) -10 (14.0) ~ 48 (118.4)
(Outdoor Temperature) Heating Min. ~ Max. ℃ WB (℉ WB) -10 (14.0) ~ 18 (64.4)

Note :
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 27°C(80.6°F) DB / 19°C(66.2°F) WB
Outdoor 35°C(95°F) DB / 24°C(75.2°F) WB
- Heating Temperature : Indoor 20°C(68°F) DB / 15°C(59°F) WB
Outdoor 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Piping Length : Interconnected Pipe Length = 5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national code.
3. Due to our policy of innovation some specifications may be changed without notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during opration.