FAQ - Causes of Electrical Cable Failure - Eland Cables
FAQ - Causes of Electrical Cable Failure - Eland Cables
Menu
Ageing:
The service life of a cable can be signi cantly reduced if it has been expected to operate outside of the optimal
operating conditions it was designed for. The ageing process usually results in embrittlement, cracking and eventual
failure of the insulating and sheathing materials, exposing the conductor and risking a potential short circuit, a likely
cause of electrical re.
Application:
If cable selected is not appropriate for the application it is more likely to fail in service. For example, a cable which is
not robust enough for the environment, either mechanically tough enough to wear and abrasion or chemically
resistant to the ambient conditions, is more likely to fail than one whose construction is suitable for the installation
environment.
Mechanical failure:
If the cable is damaged either during installation or in subsequent use, the integrity of the cable will be a ected and
reduce its service life and suitability.
There are several reasons why the sheathing material may degrade, including excessive heat or cold, chemicals,
weather conditions, and abrasion of the sheath. All of these factors can ultimately cause electrical failure as the
insulated cores are no longer protected by the sheathing as originally designed.
Moisture ingress can cause signi cant problems including short circuit and corrosion of the copper conductors.
Heating of cable:
Excessive heating of the cable will cause degradation of the insulation and sheathing material and premature failure.
The heat may come from an external source or may be generated by the resistance to current ow in the conductor -
a particular problem if the cable is overloaded and/or underrated for the application.
Electrical Overloading:
Electrical overloading normally occurs when the cable is underrated for the application or when too much load is
being placed on the cable. In domestic applications this is often a result of plugging too many appliances into the one
socket and overloading the wiring to that individual socket, extension adaptor or gang socket.
Rodent attack:
Rodents frequently attack the outer layers of cables. This damage can be extensive, signi cantly reducing the
sheathing or insulation properties of the cable, another likely source of electrical res.
UV exposure:
UV exposure can have a signi cant in uence on electrical cable insulation and sheathing. Cables likely to be exposed
to UV light should either be designed with UV resistant materials with a suitable carbon black content, or protected
from exposure with a protective covering such as installing inside cable conduit so not in direct sunlight. UV exposure
frequently causes cracking of the insulation and therefore potential short circuit failures.
(/contact/contact-us)
Call Sales on
+44 (0)20 7241 8787
Technical Hotline
+44 (0)20 7241 8500
(https://www.elandcables.com/fastquote/add-products)
https://www.elandcables.com/the-cable-lab/faqs/faq-what-are-the-main-causes-of-electrical-cable-failure 2/4
2/22/2019 FAQ: Causes of electrical cable failure | Eland Cables
(https://www.elandcables.com/the-cable-lab/customised-cable-solutions)
https://www.elandcables.com/the-cable-lab/faqs/faq-what-are-the-main-causes-of-electrical-cable-failure 3/4
2/22/2019 FAQ: Causes of electrical cable failure | Eland Cables
CONTACT US
CLICK TO EMAIL US
(MAILTO:SALES@ELANDCABLES.COM)
We will reply within 3 hours
CALL SALES ON
+44 (0)20 7241 8787 (tel:+44 (0)20
7241 8787)
FOLLOW US
(https://www.linkedin.com/company/eland-
cables)
(https://twitter.com/eland_cables?
lang=en)
(https://www.instagram.com/eland_cables/)
https://www.elandcables.com/the-cable-lab/faqs/faq-what-are-the-main-causes-of-electrical-cable-failure 4/4