Download as pdf
Download as pdf
You are on page 1of 2
(CHAPTER-1 : WIRING 1104 6sq.mmSimarked,FRLS PVC insulated, metre 106.1. 32.00 3393.60 single core copper conductor cable '=50.5x2 =101.0+5.05 (Wastage @ 5%)=106.05 m 1204 40 mm dia. ISI marked, steel conduit metre 52.50 135.00 7087.50 = 50.0 + 2.5 (Wastage @ 5%) = 52.5m 41209 40 mm inspectiony solid bends each 4.00 32.40 129.60 1214 40mm sockets each 15.00 9.00 135.00 1221. 40 mm iron staples/ saddles/ screws each 85.00 4.10 348.50 2857 PVC fastener 40mm long each 85.00 0.30 25.50 2935 Cement, paint, sand etc. LS. 1.00 5.00 5.00 Total cost of materials, 30001.60 Cartage @ 1% of At 300.02 LABOUR 1001 Wireman day 4.00 673.00 2692.00 1010 Mason, Grade 2 day 0.75 612.00 459.00 1006 Painter day 0.01 612.00 3.06 1007 Khallasi day 4.75 553.00 2626.75 TOTAL 36082.43 ‘Add 12% GST (MF = 0.1405) 5069.58 TOTAL 41152.01 OVERHEADS & PROFIT @ 15 % 6172.80 TOTAL 47324.81 Rate per meter 946.50 Say 946.00 1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm. 1.8.1 FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S, box and earthing the point with 1.5 sq.mm, FRLS PVC insulated copper conductor single core cable etc as required. GroupA COST FOR 1 POINT IcD Description Unit Qty No Rate Amount (Rs.) 1101 MATERIALS 1.5. sq. mm ISI marked, FRLS PVC insulated, metre 7.88 single core copper conductor cable = 2X3+1X1.5 = 7.5 + 0.38 (wastage @ 5%) =7.88m 9.00 70.92 DELHIANALYSIS OF RATES (E&M) 2018 19 (CHAPTER-1 : WIRING 1224 20mmdia. ISI marked, PVC conduit metre 263 10.44 © -27.46 = 2.5 + 0.13 (wastage @ 5%) = 2.63m 1229 20mm PVC bends each 1.00 4,71 4m 1234 20mm PVC couplers each 0.00 3.00 0.00 1218 20 mmiron staples/ saddles/ screws each 4.00 1.50 6.00 2851 Al. Alloy/ cadmium plated iron screws, 20 mm each 8.00 0.50 4.00 2920 Washers each 4.00 0.00 0.00 1306. 75mm X75 mm X 50 mm MS box each 1.00 19.00 19.00 1322 3mm thick phenolic laminated sheet sqem 72.00 0.10 7.20 1239 20mm PVC junction box, one way each 1.00 10.00 10.00 1431 S.P.5/6 amps, one way switch, piano type ISI marked each 1.00 10.00 ~—10.00 2857 PVC fastener 40mm long each 4.00 0.30 1.20 2935 Cement, paint, sand ete. LS. 1.00 5.00 5.00 Total cost of materials, 165.49 Cartage @ 1% of A1 1.65 LABOUR 1001 Wireman day 0.20 673.00 134.60 1010 Mason, Grade 2 day 010 612.00 61.20 1007 Khallasi day 0.30 553.00 165.90 TOTAL 528.84 ‘Add 12% GST (MF = 0.1405) 74,30 TOTAL 603.15 OVERHEADS & PROFIT @ 15 % 90.47 TOTAL 693.62 Rate per point 693.62 Say 694.00 18.2 Group B COST FOR 1 POINT ICD Description Unit Qty_-Rate. Amount No (Rs.) MATERIALS 1101 1.5sq.mmISImarked,FRLSPVC insulated, metre 1050 9.00 94.50 single core copper conductor cable = 2xd+1x2 = 10 + 0.5 (wastage @ 5%) =10.5m 1224 20mmdia. ISI marked, PVC conduit metre 3.68 «10.44 38.42. = 3.5 + 0.18 (wastage @ 5%) = 3.68m 20 DELHI ANALYSIS OF RATES (E&M) 2018

You might also like