OPERATION MANUAL
Bagging PAC
2019/07
Rev 1.07
1
ID551 Bagging PAC
Contents
CHAPTER 1.0 INTRODUCTION ............................................................................................................. 3
CHAPTER 2.0 KEYPAD AND MENU ............................................................................................................. 4
2.1 KEYPAD ....................................................................................................................................................... 4
2.2 MENU & SETUP ......................................................................................................................................... 4
2.2.1 [1 ] Calibration Block .............................................................................................................. 4
2.2.2 [2 ] Scale Application Block .................................................................................................... 5
2.2.3 [3 ] Target Controller Block ..................................................................................................... 6
2.2.4 [4 ] Input Assignment .............................................................................................................. 9
2.2.5 [5 ] Output Assignment .......................................................................................................... 15
2.2.6 [6 ] Communication Block .................................................................................................... 21
2.2.11[11 ] Maintenance Block ......................................................................................................... 21
CHAPTER 3.0 SERIAL PORT APPLICATION – MODBUS-RTU ............................................................ 22
CHAPTER 5.0 PRESET POINT APPLICATION .................................................................................. 25
5.1 PRESET POINT FEATURE .............................................................................................................................. 25
CHAPTER 6.0 HARDWARE ................................................................................................................... 26
6.1 I/F & HOUSING .......................................................................................................................................... 26
6.2 I/O APPLICATION ....................................................................................................................................... 27
6.3 DIP SWITCH & LEDS................................................................................................................................. 27
2
ID551 Bagging PAC
Operating Environment
Operating Temperature: -100C400C
Humidity: 10%95% non-condensing
3
ID551 Bagging PAC
2.1 Keypad
Key Description
〖ZERO〗, in home page, Zero Scale if gross weight in Zero range.
In setup mode, as ESC Key or Exit Key
〖TARE〗。In home page, Tare scale and save the current weight as tare
weight. In setup mode, increse cycly.
〖Clear〗。In net mode, clear tare and go back to gross weight mode.
In setup mode, Move to right cycly.
[1.2 ] Capacity
4
ID551 Bagging PAC
[1.3 ] Calibration Mode
0 - 2-pint calibration,[1.4 ] (zero point adjustment) and [1.6 ] (End
point Calibration)
1 - without big test weight calibration [1.4 ] (zero point adjustment), and
[1.7 ] (CalFree block )
Calibration steps:
[ CAL-0] [ 10] [ 9] …[ 0] [ SAVE?]
10、9… 2、1: Calibration in progress 100 – In dynamic
255 – Calibration failure 0 – Calibration complete
0 – Calibration complete
Calibration steps:
[ CAL-2] Input testing weight [ 3000] [ Ld-SP2] Add testing weight
[2.1 ] Filter
0 – Low 1 – Middle 2 – High
5
ID551 Bagging PAC
8
ID551 Bagging PAC
[4.1 ] IN1
Start/ Stop
When input 24VDC and keep IN1 on, indicator work in auto bagging mode
If IN1 OFF, indicator complete the current bagging and then work in stop mode
[4.2 ] IN2
Stop and last bag command
OFF-> ON , this rising edge inform indicator process the last bag function, stop
filling and then total weight and then complete this bag.
In general IN1 OFF first and then keep IN2 ON some time
[4.3 ] IN3
Enable or disable empty, before start empty, checking IN3 first, it is necessary to
make sure IN3 off and then start empty.
ON - Disable empty(weight out)
OFF – Enable empty
[4.4 ] IN4
OFF ON : start empty
[4.5 ] IN5
Clamp bag switch input
[4.6 ] IN6
OFF ON : Clear Alarm
[4.7 ] IN7
ON - Manual JOG,
Only work when [3.17 ] out of tolerance alarm is enabled and weight is under lower
tolerance.
[4.8 ] IN8
Force SP1, SP2, SP3 ON
9
ID551 Bagging PAC
[4.1 ] IN1
Start/ Stop
When input 24VDC and keep IN1 on, indicator work in auto bagging mode
If IN1 OFF, indicator complete the current bagging and then work in stop mode
[4.2 ] IN2
Stop and last bag command
OFF-> ON , this rising edge inform indicator process the last bag function, stop
filling and then total weight and then complete this bag.
In general IN1 OFF first and then keep IN2 ON some time
[4.3 ] IN3
Enable or disable empty, before start empty, checking IN3 first, it is necessary to
make sure IN3 off and then start empty.
ON - Disable empty(weight out)
OFF – Enable empty
[4.4 ] IN4
OFF ON : start empty
[4.5 ] IN5
Clamp bag switch input
[4.6 ] IN6
OFF ON : Clear Alarm
[4.7 ] IN7
ON - Manual JOG,
Only work when [3.17 ] out of tolerance alarm is enabled and weight is under lower
tolerance.
[4.8 ] IN8
Force SP1, SP2, SP3 ON
10
ID551 Bagging PAC
[4.1 ] IN1
Start/ Stop
When input 24VDC and keep IN1 on, indicator work in auto bagging mode
If IN1 OFF, indicator complete the current bagging and then work in stop mode
[4.2 ] IN2
Stop and last bag command
OFF-> ON , this rising edge inform indicator process the last bag function, stop
filling and then total weight and then complete this bag.
In general IN1 OFF first and then keep IN2 ON some time
[4.3 ] IN3
Enable or disable empty, before start empty, checking IN3 first, it is necessary to
make sure IN3 off and then start empty.
ON - Disable empty(weight out)
OFF – Enable empty
[4.4 ] IN4
OFF ON : start empty
[4.5 ] IN5
Reserve
[4.6 ] IN6
OFF ON : Clear Alarm
[4.7 ] IN7
ON - Manual JOG,
Only work when [3.17 ] out of tolerance alarm is enabled and weight is under lower
tolerance.
[4.8 ] IN8
Force SP1, SP2, SP3 ON
11
ID551 Bagging PAC
[4.2 ] IN2
Stop and last bag command
OFF-> ON , this rising edge inform indicator process the last bag function, stop
filling and then total weight and then complete this bag.
In general IN1 OFF first and then keep IN2 ON some time
[4.3 ] IN3
Enable or disable empty, before start empty, checking IN3 first, it is necessary to
make sure IN3 off and then start empty.
ON - Disable empty(weight out)
OFF – Enable empty
[4.4 ] IN4
OFF ON : start empty
[4.5 ] IN5
Reserve
[4.6 ] IN6
OFF ON : Clear Alarm
[4.7 ] IN7
ON - Manual JOG,
Only work when [3.17 ] out of tolerance alarm is enabled and weight is under lower
tolerance.
[4.8 ] IN8
Force SP1, SP2, SP3 ON
12
ID551 Bagging PAC
[4.2 ] IN2
Reserve
[4.3 ] IN3
Stop feeding
ON--forces the current feed process to stop, closing all outputs
[4.4 ] IN4
Reserve
[4.5 ] IN5
Clamp bag switch input
[4.6 ] IN6
OFF ON : Clear Alarm
[4.7 ] IN7
Manual clearance
ON - forces O1,O2,O3,O4 ON
[4.8 ] IN8
No push bag input
13
ID551 Bagging PAC
[4.2 ] IN2
Reserve
[4.3 ] IN3
Stop feeding
ON--forces the current feed process to stop, closing all outputs
[4.4 ] IN4
Reserve
[4.5 ] IN5
Clamp bag switch input
[4.6 ] IN6
OFF ON : Clear Alarm
[4.7 ] IN7
Manual clearance
ON - forces O1,O2,O3,O4 ON
[4.8 ] IN8
No push bag input
14
ID551 Bagging PAC
[5.1 ] O1
SP1 – Fast feed output
[5.2 ] O2
SP2 – Middle feed output
[5.3 ] O3
SP3 - Fine feed output
[5.4 ] O4
Empty output
[5.5 ] O5
Clamp bag output
[5.6 ] O6
light - Running
Flash – weight-in completed, and wait to empty
[5.7 ] O7
Out of tolerance alarm output
[5.8 ] O8
Error alarm output. (such as: return zero error, Out tolerance
Waiting for confirmation, No Empty Enable IN)
[5.9 ] O9
Flapping output, flapping bag after feeding (only allow flapping
function can have output)
15
ID551 Bagging PAC
[5.1 ] O1
SP1 – Fast feed output
[5.2 ] O2
SP2 – Middle feed output
[5.3 ] O3
SP3 - Fine feed output
[5.4 ] O4
Empty output
[5.5 ] O5
Clamp bag output
[5.6 ] O6
light - Running
Flash – weight-in completed, and wait to empty
[5.7 ] O7
Out of tolerance alarm output
[5.8 ] O8
Error alarm output. (such as: return zero error, Out tolerance
Waiting for confirmation, No Empty Enable IN)
[5.9 ] O9
Flapping output, flapping bag after feeding (only allow flapping
function can have output)
16
ID551 Bagging PAC
[5.2 ] O2
SP2 – Middle feed output
[5.3 ] O3
SP3 - Fine feed output
[5.4 ] O4
Empty output
[5.5 ] O5
On--feed complete
[5.6 ] O6
light - Running
Flash – weight-in completed, and wait to empty
[5.7 ] O7
Out of tolerance alarm output
[5.8 ] O8
Error alarm output. (such as: return zero error, Out tolerance
Waiting for confirmation, No Empty Enable IN)
[5.9 ] O9
Flapping output, flapping bag after feeding (only allow flapping
function can have output)
17
ID551 Bagging PAC
[5.2 ] O2
SP2 – Middle feed output
[5.3 ] O3
SP3 - Fine feed output
[5.4 ] O4
Empty output
[5.5 ] O5
Reserve
[5.6 ] O6
light - Running
Flash – weight-in completed, and wait to empty
[5.7 ] O7
Out of tolerance alarm output
[5.8 ] O8
Error alarm output. (such as: return zero error, Out tolerance
Waiting for confirmation, No Empty Enable IN)
[5.9 ] O9
Flapping output, flapping bag after feeding (only allow flapping
function can have output)
18
ID551 Bagging PAC
[5.2 ] O2
SP3 - Fine feed output
[5.3 ] O3
Gas Pluse1
[5.4 ] O4
Gas Pluse2
[5.5 ] O5
Clamp bag output
[5.6 ] O6
light - Running
Flash – weight-in completed, and wait to empty
[5.7 ] O7
Push bag output
[5.8 ] O8
Release bag output
[5.9 ] O9
Flapping output, flapping bag after feeding (only allow flapping
function can have output)
19
ID551 Bagging PAC
[5.2 ] O2
Fast Feed Pluse2
[5.3 ] O3
Gas Pluse1
[5.4 ] O4
Gas Pluse2
[5.5 ] O5
Clamp bag output
[5.6 ] O6
light - Running
Flash – weight-in completed, and wait to empty
[5.7 ] O7
Push bag output
[5.8 ] O8
Release bag output
[5.9 ] O9
Flapping output, flapping bag after feeding (only allow flapping
function can have output)
20
ID551 Bagging PAC
Input range is 1 ~ 99
MODBUS-RTU : 1 ~ 99
[6.2 ] Serial Port Baud Rate
0 – 1200,8,1,N 1 – 2400,8,1,N
2 – 4800,8,1,N 3 – 9600,8,1,N
4 – 19200,8,1,N 5 – 38400,8,1,N
6 – 57600,8,1,N
21
ID551 Bagging PAC
MODBUS-RTU
24
ID551 Bagging PAC
Zero Tol
Start Value
Time
Start Feed(IN)
Fast Feed(Out)
Fine Feed(Out)
Tolerance
Monitoring(Out)
Start(Out)
25
ID551 Bagging PAC
26
ID551 Bagging PAC
SW Status Description
SW-2 ON 1. Auto Zero is always disabled
2. Calibration mode is always 2-point mode
27