Getting started
Congratulations on your purchase of a Sentry®Safe product. SentrySafe is the world’s leader in
2 Gain entry with the basic electronic lock
fire/water-resistant and security storage. This guide describes how to easily set up your safe.
1-English
2 Gain entry with basic electronic lock cont. 3 Gain entry with advanced electronic lock cont.
Signals Green LED only: Icon identification 3. Enter a 4 to 8 digit code and press the Prog/
Your electronic-lock safe communicates by means 1. Comes ON after you enter a valid code and (Error) indicates one of the following: Enter key to finish programming the code into
of several audio/visual signals. remains lit during the 4-second period in which 1. You have pressed Program key out of sequence. the unit.
Red (Error) LED + three beeps indicates the safe can be opened. 2. You have entered an invalid code. To delete:
one of the following: 2. Comes ON in the Programming mode and 3. You have let 5 seconds or more elapse between 1. Press the Prog/Enter key, then enter the 5-digit
1. You have pressed Program key out of sequence. remains lit until you have finished entering key presses. factory code and then press the Prog/Enter key.
2. You have entered an invalid code or user pin. a 5-digit code. 2. A boxed lighted * icon ( ) indicates there is a
4. You have pressed a key while in delay mode.
3. You have let 5 seconds or more elapse between Yellow LED only: code programmed and can be deleted.
1. Comes ON when the batteries need to be (Program) Lights after pressing the Program
key presses. key and stays lit while programming a manager or 3. Press 0, 0, 0, 0, then the Prog/Enter key to
replaced. delete the manager code. (0, 0, 0, 0, Prog/
4. Lights after three consecutive invalid codes are user code.
Enter).
input (2-minute delay mode).
(Delay Mode) Lights after three consecutive NOTE: To return to the beginning when
invalid codes are input and stays lit during the programming a manager or user code, wait 5
2-minute delay mode. seconds and the lock will time-out. You may then
start over.
3 Gain entry with advanced electronic lock Access codes
There are 3 possible ways to unlock and access
the safe: Programming user code
To unlock safe: NOTE: Six (6) user codes are allowed.
Enter the 5-digit factory code, a pre-programmed NOTE: Maintain a record of the factory code, user,
manager code, or a pre-programmed user code and manager codes, and store them in a secure To add:
(programming instructions to follow), then press location other than in this safe. 1. Press the Prog/Enter key 2 times, enter the
the Prog/Enter key. When the unlocked padlock manager code and then press the Prog/Enter
1. Factory code key.
icon ( ) appears, you have four seconds to turn
(Found on the first page of this guide) You can
the handle down to open. 2. Use the << or >> to scroll between the lighted
always open the safe by entering the pre-set 5-digit
To lock safe: factory code. This code cannot be deleted. boxes. An empty box icon ( ) means it is
Close the door and return the handle to the available for a code entry; a boxed lighted *
horizontal position. For greatest security, depress 2. Manager code icon ( ) means it is being used.
Opening your safe for the first time (keep the key lock (if equipped) with your finger. If you prefer to employ your own code, you can
door open during setup): program the safe to open to a 4-8 digit manager 3. Enter a 4 to 8 digit code in the selected position
1. Remove and discard the screw (if equipped) at code of your choice. and press the Prog/Enter key to finish.
NOTE: If your unit is equipped with a water-
the base of the lock case. resistant gasket. Additional pressure to the left To delete:
3. User code
2. Turn the electronic lock case to the corner of the door may be required before the If you wish to give someone else temporary access 1. Press the Prog/Enter key 2 times, enter the
2 right (clockwise), from 12 o’clock to handle can be returned to the horizontal position. to the safe, you can program a 4-8 digit user code manager code and then press the Prog/Enter
2 o’clock, and remove. that can later be erased. key.
• Insert 4 new AA batteries (not Battery replacement 2. Use the << or >> to scroll to the boxed lighted
The battery icon ( ) will light when the NOTE: Remember, once you have decided on your
1 included) to power this lock. access codes, open the unit first then test it with * icon ( ) to be removed.
batteries need to be replaced. No codes are erased
• Replace the electronic lock case and the door open. All zeros is an invalid code. 3. Press 0, 0, 0, 0, then the Prog/Enter key to
when old batteries are removed for replacement.
turn to the left (to 12 o’clock) to reassemble. delete the selected user. (0, 0, 0, 0, Prog/Enter).
See “Opening your safe for the first time”. Programming the manager code
3. Turn the key (if your safe is equipped with a key NOTE: One (1) manager code is allowed.
lock) to the right so that the lock cylinder pops NOTE: If your safe does not appear to be working, NOTE: To turn the beeper on or off, press the 0
out. please check batteries before calling Sentry To add: key and then the Prog/Enter key. (0, Prog/Enter).
Customer Care. 1. Press the Prog/Enter key , then enter the 5-digit
4. Enter the factory code (printed on the first page
of this guide), then press the Prog/Enter key. factory code and then press the Prog/Enter key .
When the unlocked padlock icon ( ) appears, 2. An empty lit box icon ( ) means no manager
you have four seconds to turn the handle down code is programmed. A boxed lighted * icon
to open. Try this several times before proceeding ( ) means a manager code is programmed.
to the next step.
2-English
4 Floor Mount (optional) Sentry Safe First-Class Customer Care
®
XY1234
number can be found near the door hinge as
Masonry anchoring: the back or sides. Bolting/unbolting of the unit is shown or at the beginning of this guide.
3⁄8"(9.50 mm) drill bit at the consumers expense and discretion. Sentry
Group is not responsible for any costs incurred if
Instructions: the unit is to be replaced.
1. Tip the safe onto its right side. (Door Troubleshooting Delay mode
• If electronics are not functioning, replace Enters a two-minute delay mode after an invalid
hinges horizontal with the floor.) code has been entered three consecutive times.
batteries first (behind electronic lock case)
C 2. Unlock the safe and open the door. In this mode, the lock can not be activated and
as described in step one of this guide.
3. Look on the bottom of the safe for two any key entry will generate an ERROR signal.
• If electronics are functioning and you cannot get
indentations on the feet in opposite into safe:
corners. Using the 7⁄16" (11.0 mm) bit,
drill a hole through each indentation - Pull handle up
perpendicular to the bottom of the safe - Follow instructions for opening your lock type.
(Fig. B). Do not drill from any location
D inside the safe. • You must use both the key (if equipped) and the
4. Close the door and tip the safe upright. electronic code to open the safe if the key lock
Place it where desired and reopen the cylinder is pushed in.
door.
5. Use a screw or drill bit to mark the floor
through both holes. (Fig. C) Registration: To be eligible for warranty coverage, the original purchaser must register
E
6. Move the safe aside to clear both marked the product online at www.sentrysafe.com or complete and return to Sentry Group
spots for drilling. the enclosed registration card.
7. Drill into the floor:
A. For wood: Using the wood drill bit,
drill a hole 2-1⁄2" (64 mm) deep in each accumulate inside your safe. Please open measure which the UL classification
your unit periodically to avoid moisture performance standard indicated guarantees.
marked spot. (Fig. D) accumulation. Therefore, DO NOT store pearls in your
B. For masonry: Using the masonry bit, SentrySafe product.
F If you choose to store delicate items such
drill a hole 2-1⁄2" (64 mm) deep in each as jewelry with working parts, watches,
marked spot. (Fig. D) Install a masonry stamps, or photos in your safe, we WARNING
anchor in each hole. recommend putting them in an air-tight No computer disks, audio-visual
container, prior to placing them in the safe media or photo negatives.
WARNING for storage. This product is not intended to protect
8. Replace the safe in the desired position, DO NOT store delicate computer floppy or diskettes, cartridges
with the holes in the safe aligned with items directly in your safe. NOTE: Sentry Group will not be responsible and tapes, audio or video cassettes or
SentrySafe products which offer fire for any damage or loss of items placed in photo negatives. For fire-resistant storage
protection have a proprietary insulation that the unit due to moisture. of these materials, ask your retailer for
has a high moisture content. In addition the SentrySafe Fire-Safe Media storage
the SentrySafe advanced safes close airtight products.
to offer water resistance, which may also WARNING
cause moisture to accumulate inside your DO NOT store pearls
safe. The desiccant packet included in your in this safe unit.
safe during shipment, should be left in your In the event of a fire, potential damage to
safe. DO NOT DISCARD IT. It is intended delicate pearls occurs at temperatures much
to help absorb moisture which may lower than the 350°F interior performance
3-English
Rigorous testing ensures this product meets our specifications
1-Hour
Models Subjected to Subjected After being 1-hour
temperatures up to 1700°F to flash fire in a heated to 1550°F fire protection
(927°C) for duration of 2000°F (1093°C) (843°C) the of CD’s, DVD’s,
1-hour, the safe interior furnace for 30 safe is dropped memory sticks,
will remain below 350°F minutes, the unit 15 feet onto and USB drives
(177°C). This enables your will not explode or rubble, then up to 1700°F
safe to withstand even high rupture. cooled, inverted (927°C).
temperature exposure, as the and reheated to
hottest part of a fire moves 1550°F (843°C)
through a building. for 30 minutes.
1-hour
2.0 Subjected to Subjected After 1-hour
Cu. Ft. temperatures up to 1700°F to flash fire in a being heated to fire protection
Models (927°C) for duration of 2000°F (1093°C) 1550°F (843°C) of CD’s, DVD’s,
1-hour, the safe interior furnace for 30 the safe is memory sticks,
will remain below 350°F minutes, the unit dropped 30 feet and USB drives
(177°C). This enables your will not explode or onto rubble, then up to 1700°F
safe to withstand even high rupture. cooled, inverted (927°C).
temperature exposure, as the and reheated to
hottest part of a fire moves 1550°F (843°C)
through a building. for 30 minutes.
2-Hour
Models Subjected to Subjected After 2-hour
temperatures up to 1850°F to flash fire in a being heated to fire protection
(1010°C) for duration of 2000°F (1093°C) 1638°F (892°C), of CD’s, DVD’s,
2-hours, the safe interior furnace for 30 the safe is memory sticks,
will remain below 350°F minutes, the unit dropped 30 feet and USB drives
(177°C). This enables your will not explode or onto rubble, then up to 1850°F
safe to withstand even high rupture. cooled, inverted (1010°C).
temperature exposure, as the and reheated to
hottest part of a fire moves 1638°F (892°C)
through a building. for 45 minutes.
NOTE: For the gasket to work effectively, the safe door must be closed with the handle fully horizontal.
When you move the handle, the compression of the gasket will require slightly more force than you
would use with a safe that does not have a gasket.