Download as pdf or txt
Download as pdf or txt
You are on page 1of 139

Final Drawing

Kongsberg Maritime
GYRO System

DSME 2258/2259

Copy number:_____
Unregistered copies will not be updated. July 2009
DSME 2258/2259 GYRO SYSTEM INDEX
Part nr. Doc nr. Title

1 Scope of supply
Main Part List
Spare Part List

2 System drawings
Radar System

3 Manual
Heading Reference System
1001316C NAVIGAT X MK I
1001294A Switch-over unit for Gyro system
1001295A Steering Repeater 360°/10°, with Dimmer, flush mounted
1001308A Bearing Repeater 360° Compass Card, in Bracket or Stand
1001357B Universal Digital Repeater, flush mounted
1001417B Rate of Trun Indicator, 90deg./min, 144ⅹ144, flush mounted
1001359C Universal Digital Repeater, bulkhead/desk mounted
1001419B Course and Rudder Angle Recorder, NAVIPRINT
1001359C Universal Digital Repeater,Bulkhead
173528B Universal Digital Repeater, operation manual
SCOPE OF SUPPLY
1.Project No : DSME 2258/2259
2.System name : Navigation

Item Supply Sub


Description of Product/Type Part no Remark
NO Qty Maker

Gyro Compass system

1 Gyrocompass Navigat X MK1 2 KM/Decca

2 Gyrosphere for NAVIGATE X, 74571 2 KM/Decca

3 Installation kit NAVIGATE X Gyro, 74696 2 KM/Decca

4 Gyro container in transport box. Type: 22 4181 2 KM/Decca

5 Gyro control & display unit gyro NAVITWIN IV 1 KM/Decca

6 Gyro switch over unitType: 74742 1 KM/Decca

7 Steering Repeater 1 KM/Decca

8 Bearing Repeater Compass for wings 2 KM/Decca

9 Prismatic Azimuth Device 1 KM/Decca

10 Universal Digital Repeater,Console Mounting 2 KM/Decca

11 Dimmer for universal digital repeaterPanel mounted. 1 KM/Decca

12 Universal Digital Repeater,Bulkhead type 2 KM/Decca

13 Rate of turn indicator +/-90 deg. IP67 144 X 144mm 1 KM/Decca

14 Dimmer for Rate of trun indicator 1 KM/Decca

15 Course Recoder Printer 1 KM/Decca

1 of 1
SPARE PART LIST
1.Project No : DSME 2258/2259

2.System name : Navigation

Item Supply
Description of Product/Type Part no Unit Remark
NO Qty

1 Fuse glas 0.5A /T 5x20 3700015 4,00 stk


2 Fuse glas 3,15A/F 250V 5X20mm 3700388 2,00 stk
3 LIGHT BULB Use instead:703252 3700743 1,00 stk
4 Fuse link 3,15A slow, MA00007245 703330 10,00 Stk
5 Belt drive (40W), MA00008979 703306 1,00 Stk
6 Fuse ceramic 16A slow, 2162342 703337 10,00 Stk
7 Fuse link 3,15A slow, MA00007245 703330 10,00 Stk
8 Fuse Ceramic 5x20 0.5A 250V T U0215005 44489565 10,00 Stk
9 Fuse Ceramic 5x20 2,0A 250V T 43505833 10,00 Stk
10 Fuse Ceramic 5x20 6,3A 250V T 43522218 10,00 Stk
11 Fuse glas 0.5A /T 5x20 3700015 2,00 stk
12 Fuse glas 3,15A/F 250V 5X20mm 3700388 2,00 stk
13 Fuse Ceramic 5x20 6,3A 250V T 43522218 2,00 Stk
14 Power, 100-240VAC/5A,24VDC/10A, *507 47749445 1,00 Stk
15 RIO400 Fan kit 600686 1,00 Stk
16 *3A, FN2080-3-07 3600228 1,00 pcs
17 Fuse switch 2 X 5 Amp 3700655 2,00 pcs
18 Fuse ceramic 5A slow, 2180413 703332 10,00 Stk
19 BATTERY 3V LITHIUM CR2032 3800159 1,00 pcs
20 Power, 100-240VAC/5A,24VDC/10A, *507 47749445 1,00 Stk
21 Fuse Ceramic 5x20 0.5A 250V T U0215005 44489565 10,00 Stk
22 Fuse Ceramic 5x20 2,0A 250V T 43505833 10,00 Stk
23 Fuse Ceramic 5x20 6,3A 250V T 43522218 10,00 Stk
24 GPS antenna GPS4, A101-01 602975 1,00 Stk
25 DGPS antenna, MX521 727010 702250 1,00 Stk
26 Spare part kit NAVIPOL, 73303 702530 1,00 Stk
27 Bearing & HM PCB, T65801805 703303 1,00 Stk
28 Circulator 30Kw, S-band, T91005223 703323 1,00 Stk
29 Limiter 30Kw, S-band, T91005224 703321 1,00 Stk
30 Magnetron 30Kw, S-band,T91005225, MG5223 703322 1,00 Stk
31 Limiter 25Kw (active) X-band, T91005226 703315 1,00 Stk
32 Magnetron 25Kw, X-band 703316 1,00 Stk
33 Transceiver interface PCB TICS, NA1077 6200421 1,00 Stk
34 Heading Wheel FOP 603550 1,00 Stk
35 NA1149 RIC 2 6200455 1,00 pcs
36 TBSS - Termination Serial line switch 37960309 1,00 Stk
37 BUZZER 90dB WHITE BS24-R1 3700688 1,00 pcs
38 Power MW DR-120-24 C5A Output 702978 1,00 Stk
39 Hard Disc Drive 80GB SATA-3G 302265 1,00 pcs
40 Panel Input 603524 1,00 pcs
41 Installationkit NAVIGATE X gyro, 4696 4401491 1,00 stk
42 Circulator, X-band, T91005227 703317 1,00 Stk
43 Magnetron 10Kw X-Band, T91003582,MG5241 703328 1,00 Stk
44 TBSL RS422 ISOLATED ADAPTER 37767563 1,00 pcs
45 SPBUS-TERM 600198 1,00 Stk
46 Speed log digital indicator IR30 702190 1,00 Stk
47 DIMMER FOR REPEATER IR300/301 4604210 1,00 stk
48 Depth indicator digital, IR301 EN301K 4604209 1,00 stk
49 Relay, 12V DC coil, RS32/3313940602 3600156 1,00 pcs
50 DIMMER 24V DC 4602426 1,00 stk
51 Universal digital repeater 311800 1,00 pcs
52 Timer reset push button 3500938 1,00 pcs
53 FAN 12V PAPST 512F 3600331 1,00 stk
54 Single ph. bridge recti. SB251 2 701683 1,00 Stk
55 R/I Converter, Stork-Kwant 51002997 701365 1,00 Stk
56 Iso.Amplifier MCR-C-UI-UI-DCI-SOKS 701567 1,00 Stk
57 Relay Finder 5534 9 024 0040 *235 47715156 1,00 Stk
58 Rele Omron G2R-1-SNI 1pol - 24VDC *774 47745807 1,00 Stk
59 FUSE MCB 2-pole 6A C-kar.(CBI :QFB28206) 701857 1,00 Stk
60 Filter Schaffner FN 2080-6-06 6A *176 47746748 1,00 Stk
Installation Manual

Installation Manual
Master Gyrocompass,
NAVIGAT X Mk1
Kongsberg Part no.:
NAVIGAT X Mk1: 703492

This manual describes the installation of the Master


Gyrocompasses, NAVIGAT X Mk1 supplied by C. Plath.

1001316/C 1
Master Gyrocompasses, NAVIGAT X Mk1

Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A 22.03.04 SEM 31.03.04 OMH 05.05.04 TH
B 01.04.05 SEM 14.04.05 OMH 15.04.05 TH
C 21.10.05 SEM 24.10.05 OMH 25.10.05 TH

The original signatures are recorded on the company’s logistic data system.

Document history
Rev. A First version.
Rev. B New P/N for equipment on page 1, which implies a new Kongsberg drawing number
1010204, sh.1 and 2.
Rev. C Reference to Set-up procedure has bee removed in section 3.3.1 Gyrocompass
Housing, step 2.

Table of contents

1 INTRODUCTION ................................................................................................... 3

2 SPECIFICATIONS ................................................................................................. 4
2.1 Master Gyrocompasses ...................................................................................... 4

3 INSTALLATION .................................................................................................... 6
3.1 General information ........................................................................................... 6
3.2 Handling............................................................................................................. 6
3.3 Mechanical installation ...................................................................................... 7
3.3.1 Gyrocompass Housing................................................................................ 7
3.3.2 Gyrosphere.................................................................................................. 7
3.4 Electrical installation.......................................................................................... 8
3.4.1 The Connection Diagram............................................................................ 8
3.4.2 Connecting the Ship’s Cables ..................................................................... 8

4 INSTALLATION DRAWINGS ............................................................................. 9

2 1001316/C
Installation Manual

1 INTRODUCTION
This document describes the installation of the Master
Gyrocompass, NAVIGAT X Mk1.
The Master Gyrocompasses are a microprocessor controlled
gyrocompass system with integrated automatic north speed error
correction.
KM P/N: 703492 for the NAVIGAT X Mk1: contains the
following parts:
− Gyrocompass NAVIGAT X MK1, HSC, Type: 74807
− 1 Gyro container in transport box, Type: 22418
− 1 Gyrosphere in transport box, Type: 74571
− 1 Installation Kit. Type 74696
− 2 Manuals on CD-Rom. Type: 56800

WARNING The Gyrocompass contains mercury. Spilt mercury will


evaporate and give off poisonous fumes.

WARNING The equipment includes high voltage (115/230V) which means


that the possibility for getting an electrical shock is present.

Note Unless stated otherwise, all equipment referred to within this


document are to be supplied by yard/customer.

Note The guidelines for installation presented here must be regarded as


a base for detailed plans prepared by the installation shipyard.
These plans must include drawings, instructions and procedures
specific to the ship in which the equipment is to be installed. These
drawings must be approved by the local maritime classification
society.

Note Unless stated otherwise, all installation work described in this


document is to be performed by yard/customer personnel.
It is the responsibility of the yard/customer to assure that their
installation personnel are sufficiently qualified, and that proper
caution is taken to avoid injuries or damage to life, health,
environment, equipment and property.

Kongsberg Maritime AS accepts no responsibility for any damage


or injury to the system, ship or personnel caused by drawings,
instructions or procedures not prepared by Kongsberg Maritime.

1001316/C 3
Master Gyrocompasses, NAVIGAT X Mk1

2 SPECIFICATIONS

2.1 Master Gyrocompasses


For dimensions and data, refer to Kongsberg drawing number
1010204.

Electrical specifications
Voltage input:.....................115/230 VAC +10% (normal supply)
........................................24VDC (18 – 36V) (emergency supply)
Power consumption:
- Start up:.............................................. 80W (DC), 125VA (AC)
- Operation: ............................................ 45W (DC), 75VA (AC)
Batteries: ...............................................................................None

Data Outputs
Repeater outputs........................................................................ 12
• Gyrocompass heading
• Magnetic compass heading
• Rate of turn
• Heading reference status
• Supply power 24 VDC, max. 7 W each
Data outputs NMEA.................................................................... 2
• Gyrocompass heading
• Magnetic compass heading
• Rate of turn
• Position
• Speed
• Heading reference status
Data outputs RS 422 ................................................................... 3
• Gyrocompass heading
• Magnetic compass heading
• Rate of turn
• Position

4 1001316/C
Installation Manual

• Speed
• Heading reference status
Data output RS 422 FAST .......................................................... 1
• Gyrocompass heading
• Magnetic compass heading
• Rate of turn
Data output RS 422 SUPERFAST.............................................. 1
• Gyrocompass heading
• Magnetic compass heading
• Rate of turn
• Heading reference status
6 step/°-outputs ........................................................................... 2
• Act. Heading; 24 VDC, max. 18 W
• (12 –70 VDC with ext. power supply)
Analogue rate of turn output ....................................................... 1
• ±0.1-999.9 mV/°/min, setable; max. 10V, 10mA
Voyage data printer output.......................................................... 1
• Act. heading
• Rudder angles
• Date
• Time
• Heading reference
• Steering mode
• Speed
• Position

Alarm and Status Outputs


Pwr. failure / general device error alarm.... Potential-free contact;
max. 30W, 1A; 125 V
AC power supply ....................................... Potential-free contact;
max. 30W, 1A; 125 V
Heading ref. status (G1/G2/Mag)............... Potential-free contact;
max. 30W, 1A; 125 V

1001316/C 5
Master Gyrocompasses, NAVIGAT X Mk1

Heading difference alarm........................... Potential-free contact;


max. 30W, 1A; 125 V
Max Rate of Turn (ROT) alarm ................. Potential-free contact;
max. 30W, 1A; 125 V
Watch alarm trigger output ........................ Potential-free contact;
max. 30W, 1A; 125 V

Environmental specification
Enclosure material: ............................... Polyurethane Hard Foam
Enclosure protection: ............................................................IP 23
EMC:............................................................................ IEC 60945
Operating Temperature: ........................................... -10 to +55°C
Operating Humidity: .................................................... IEC 60945
Storage Temperature: .....-25 to +70°C (without supporting fluid)
Storage Humidity: ........................................................ IEC 60945

3 INSTALLATION

3.1 General information


This chapter presents the procedures and drawings for installation
of the Master Gyrocompasses.
The Gyrocompass System comprises a compass housing complete
with base plate assembly, master board and control and display
unit, a gyrosphere container, a gyrosphere and an installation and
replacement kit.

3.2 Handling
The Gyrocompasses are contained in a shockproof box, which is
packed in a Transport container.
This Transport container is completely suitable for transport by air,
sea, rail and road.
Caution The Gyrosphere is always to be transported in its original
Transport container. Do not throw or drop the transport
container. The container is to be transported in an upright
position only.

6 1001316/C
Installation Manual

Until installation, the shockproof box containing the gyrosphere is


to be stored in its original Transport container and is to be carried
by hand directly to the place of installation.
Caution The shockproof box containing the gyrosphere is only to be
transported by hand, and is to be handled by extreme care.

3.3 Mechanical installation


3.3.1 Gyrocompass Housing
1 Attach the Compass housing is to a level surface e.g. a floor
or console by means of six M10 bolts or welding studs (to be
supplied by yard/customer). It is essential that the installation
place has even ground. At the place of location of the
compass, proper ventilation must be ensured and sufficient
space provided for the housing to be opened and maintenance
work to be carried out. The amount of space required, the
attachment points and the position of the cable inlets are
shown in the dimension drawing attached in section 4 of this
document.
Be aware of magnetic clearance minimum distances listed on
the Kongsberg drawing number 1010204 page 2.
2 Install the gyrocompass housing in the horizontal plane,
preferably in line with the vessel’s longitudinal axis. It may
however be installed at any angle with respect to the vessel’s
longitudinal axis.
Alignment error (i.e. the angle between the compass’ and the
vessel’s longitudinal axis) is corrected electronically by setting the
alignment error correction value in the service set-up.
3
Note If the Gyrocompass is mounted with an offset from
the Vessel’s longitude axis, this angle should be
given Kongsberg Maritime before commissioning.
There are no specific prescriptions to the foundation stiffness,
but it has to be a fixed, even ground like vessel’s deck.
4 Prepare a welded grounding bolt on the side of the
Gyrocompass.

3.3.2 Gyrosphere
Gyrosphere installation is only to be carried out by personnel
especially authorised by the manufacturer. This procedure is
therefore not a part of this manual.

1001316/C 7
Master Gyrocompasses, NAVIGAT X Mk1

3.4 Electrical installation


3.4.1 The Connection Diagram
For electrical installation of the equipment, refer to the Cable List
and Cable Details documents for the actual project.
Cable termination and earthing details is described in the Earthing,
Screening and Power Supply Principles document (Kongsberg
document number 848-161012).

3.4.2 Connecting the Ship’s Cables


All ship’s cables are connected at the Terminal board of the Master
gyro. For Master gyro terminal board-layout, refer to Figure 1.
1 Insert the ship’s cables through the inlets at the sides of the
Compass housing.
2 Remove the outer cable covers, draw back the cable shields
and fasten the cables with clamps or cable bands to the
threaded studs. For details refer to Kongsberg drawing
number 1010204.
3 Remove the terminal strips from their sockets and connect the
individual wires. After wiring, fasten the terminal strips to the
sockets with their securing screws.
4 Keep all wires, running inside the housing, as short as
possible. Avoid leading the wires from one side of the
housing to the other.
5 Connect the Gyrocompass to the ships ground by clamping a
braided copper wire to one of the threaded studs at the cage
inlets. Connect this braided copper wire to the welded
grounding bolt on the side of the Gyrocompass.

8 1001316/C
Installation Manual

4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:

Title Fig./Dwg. No. Rev. Sheets


Bridgeline, C.Plath Gyrocompass Navigat X Mk1, 1010204 A 1_2
Mech. Det. Dwg
Bridgeline, C.Plath Gyrocompass Navigat X Mk1, 1010204 A 2_2
Mech. Det. Dwg
Master gyro, Terminal board-layout Figure 1 - -

1001316/C 9
Master Gyrocompasses, NAVIGAT X Mk1

10 1001316/C
Installation Manual

1001316/C 11
Master Gyrocompasses, NAVIGAT X Mk1

Figure 1 Master gyro, Terminal board-layout

12 1001316/C
Installation Manual

Installation Manual
Switch-over unit for
Gyro system
Kongsberg Part no.:
Switch-over unit: 701935

This manual describes the installation of the Switch-over unit


supplied by C. Plath.

1001294/A 1
Switch-over unit

Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A 22.03.04 SEM 31.03.04 OMH 19.08.04 TH

The original signatures are recorded on the company’s logistic data system.

Document history
Rev. A First version.

Table of contents

1 INTRODUCTION ................................................................................................... 3

2 SPECIFICATIONS ................................................................................................. 4
2.1 Switch-over unit ................................................................................................. 4

3 INSTALLATION .................................................................................................... 4
3.1 Handling............................................................................................................. 4
3.2 Mechanical installation ...................................................................................... 4
3.3 Electrical installation.......................................................................................... 5

4 INSTALLATION DRAWINGS ............................................................................. 5

2 1001294/A
Installation Manual

1 INTRODUCTION
This document describes the installation of the Switch-over unit.
The Switch-over unit is supplied as a standalone unit and is an
optional accessory to the Navigat X Mk1 and Navigat SR 2100
Gyro compass system. The Switch-over unit connects the in- and
outputs of the currently selected heading reference to the peripheral
equipment, such as heading repeaters, autopilots radars etc.
Note The Switch-over unit will be hardwired to operate in one particular
operating mode. Always consult the installation specific connection
diagrams and documentation to determine how the unit is operated
in a given installation.

Note The guidelines for installation presented here must be regarded as


a base for detailed plans prepared by the installation shipyard.
These plans must include drawings, instructions and procedures
specific to the ship in which the equipment is to be installed. These
drawings must be approved by the local maritime classification
society.

Note Unless stated otherwise, all installation work described in this


document is to be performed by yard/customer personnel.
It is the responsibility of the yard/customer to assure that their
installation personnel are sufficiently qualified, and that proper
caution is taken to avoid injuries or damage to life, health,
environment, equipment and property.

Kongsberg Maritime AS accepts no responsibility for any damage


or injury to the system, ship or personnel caused by drawings,
instructions or procedures not prepared by Kongsberg Maritime.

1001294/A 3
Switch-over unit

2 SPECIFICATIONS

2.1 Switch-over unit


For dimensions and data, Refer to Kongsberg drawing number
507943.

Electrical specifications
Input voltage: ................................................................... 24 VDC
Backup voltage:................................................................ 24 VDC

Environmental specification
Enclosure protection: ............................................................IP 23
Operating Temperature: .........................................-10° to +55 °C
Operating Humidity: ........................................................ IEC 945
Storage Temperature:.............................................-25° to +70 °C
Storage Humidity: ............................................................ IEC 945

3 INSTALLATION
This chapter presents the procedures for installation of the Switch-
over unit.

3.1 Handling
Care should be taken when unpacking and handling the equipment.
A visual inspection should be made to check that the equipment has
not been damaged during shipment and that all components and
parts are present according to the packing list.
The equipment can be lifted by hand.
The equipment contains delicate electronic components – handle
accordingly.

3.2 Mechanical installation


Throughout installation of the Switch-over unit, refer to attached
Kongsberg drawing 507943.
For mechanical installation of the Switch-over unit, proceed as
follows:

4 1001294/A
Installation Manual

1 Decide the location of the Switch-over unit.


2 Prepare mounting arrangement for the Switch-over unit in the
bulkhead according to the installation drawing, 507943.
3 Place the Switch-over unit in its position.
4 Use bolts, washers and nuts and fasten the Switch-over unit
to the bulkhead.
5 Prepare a welded grounding bolt on the side/underneath the
Switch-over unit.

3.3 Electrical installation


For electrical installation of the Switch-over unit, refer to the Cable
List and Cable Details documents for the actual project.
Cable termination and earthing details is described in the Earthing,
Screening and Power Supply Principles document (Kongsberg
document number 848-161012).
For electrical installation of the Switch-over unit, proceed as
follows:
1 Terminate cable screen, refer to Kongsberg drawing 507943.
2 Connect peripheral equipment according to Figure 1, Figure 2
and Figure 3, and the Cable List and Cable Details.
3 Connect the Switch-over unit to the ships ground by
clamping a braided copper wire to one of the threaded studs
at the cage inlets. Connect this braided copper wire to the
welded grounding bolt on the side/underneath the Switch-
over unit.

4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:

Title Fig./Dwg. No. Rev. Sheets


Outline dimension, Switch-over unit 4932/74742, 507943 A 1
Bridgeline
Terminal connections Figure 1 - -
Connection diagram Figure 2 - -
Connection diagram (continued) Figure 3 - -

1001294/A 5
Switch-over unit

6 1001294/A
Installation Manual

Figure 1 Terminal connections

1001294/A 7
Switch-over unit

Figure 2 Connection diagram

8 1001294/A
Installation Manual

Figure 3 Connection diagram (continued)

1001294/A 9
Installation Manual

Installation Manual
Steering Repeater 360°/10°,
with Dimmer, flush mounted
Kongsberg Part no.:
Steering Repeater: 701415

This manual describes the installation of the Steering Repeater


360°/10°, with Dimmer, flush mounted supplied by C. Plath.

1001295/A 1
Steering Repeater 360°/10°, with Dimmer, flush mounted

Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A 18.03.04 SEM 31.03.04 OMH 19.08.04 TH

The original signatures are recorded on the company’s logistic data system.

Document history
Rev. A First version.

Table of contents

1 INTRODUCTION ................................................................................................... 3

2 SPECIFICATIONS ................................................................................................. 4
2.1 Steering Repeater ............................................................................................... 4

3 INSTALLATION .................................................................................................... 4
3.1 Handling............................................................................................................. 4
3.2 Mechanical installation ...................................................................................... 5
3.3 Electrical installation.......................................................................................... 5

4 INSTALLATION DRAWINGS ............................................................................. 5

2 1001295/A
Installation Manual

1 INTRODUCTION
This document describes the installation of the Steering Repeater
360°/10°, with Dimmer, flush mounted to be used with C. Plath
Gyro system.

Note The guidelines for installation presented here must be regarded as


a base for detailed plans prepared by the installation shipyard.
These plans must include drawings, instructions and procedures
specific to the ship in which the equipment is to be installed. These
drawings must be approved by the local maritime classification
society.

Note Unless stated otherwise, all installation work described in this


document is to be performed by yard/customer personnel.
It is the responsibility of the yard/customer to assure that their
installation personnel are sufficiently qualified, and that proper
caution is taken to avoid injuries or damage to life, health,
environment, equipment and property.

Kongsberg Maritime AS accepts no responsibility for any damage


or injury to the system, ship or personnel caused by drawings,
instructions or procedures not prepared by Kongsberg Maritime.

1001295/A 3
Steering Repeater 360°/10°, with Dimmer, flush mounted

2 SPECIFICATIONS

2.1 Steering Repeater


For dimensions and data, refer to Kongsberg drawing number
507944.

Electrical specifications
Input voltage: .................................................................... 24VDC
Minimum magnetic clearance to:..................................................
- Standard magnetic compass:............................................. 0,70m
- Steering magnetic compass: ............................................. 0,45m
Minimum magnetic clearance (reduced) to: .................................
- Standard magnetic compass:............................................. 0,45m
- Steering magnetic compass: ............................................. 0,30m

Environmental specification
Protection (front):..................................................................IP 66
Operating Temperature: .........................................-15° to +55 °C
Operating Humidity: ........................................................ IEC 945
Storage Temperature:.............................................-40° to +80 °C
Storage Humidity: ............................................................ IEC 945

3 INSTALLATION
This chapter presents the procedures for installation of the Steering
Repeater 360°/10°, with Dimmer, flush mounted.

3.1 Handling
Care should be taken when unpacking and handling the equipment.
A visual inspection should be made to check that the equipment has
not been damaged during shipment and that all components and
parts are present according to the packing list.
The equipment can be lifted by hand.
The equipment contains delicate electronic components – handle
accordingly.

4 1001295/A
Installation Manual

3.2 Mechanical installation


Throughout installation of the Steering Repeater, refer to attached
Kongsberg drawing 507944.
For mechanical installation of the Steering Repeater, proceed as
follows:
1 Decide the location of the Steering Repeater.
Note Be aware of magnetic clearance minimum distances
listed in section Specifications.
2 Cut hole for installation of the Steering Repeater in the
console according to the installation drawing, 507944.
3 Drill holes (4 off) for the mounting bolts in the console
according to the installation drawing.
4 Attach adhesive seal on the Steering Repeater according to
the installation drawing.
5 Place the Steering Repeater in its position.
6 Fasten the Steering Repeater to the console by the 4 off
mounting bolts, and use washers and nuts.

3.3 Electrical installation


For electrical installation of the Steering Repeater, refer to drawing
SC40771 as well as the Cable List and Cable Details documents
for the actual project.
Cable termination and earthing details is described in the Earthing,
Screening and Power Supply Principles document (Kongsberg
document number 848-161012).

4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:

Title Fig./Dwg. No. Rev. Sheets


Mech. Det. Dwg, 192x192, Type 4881-AA/74486, C.Plath 507944 A 1
Steering Repeater
Bridgeline Steering Repeater C.Plath, Connection diagram SC40771 E 1

1001295/A 5
Steering Repeater 360°/10°, with Dimmer, flush mounted

6 1001295/A
Installation Manual

1001295/A 7
Installation Manual

Installation Manual
Bearing Repeater 360° Compass
Card, in Bracket or Stand
Kongsberg Part no.:
Bearing Repeater, 360° Compass Card, 700215
Bracket for Bearing Repeater: 701929
with Connection box and Dimmer
Azimuth Device: 700217
Cover Plate for Bearing Repeater: 701930
Stand for Bearing Repeater: 700237
with Connection box and Dimmer
Plastic Cover for Stand: 2603752
This manual describes the installation of the Bearing Repeater
Compass Card, 360º Card in Bracket or Stand supplied by C.
Plath.

Bracket for Stand for


Bearing Repeater Bearing Repeater Azimuth Device Bearing Repeater

1001308/A 1
Bearing Repeater 360° Compass Card, in Bracket or Stand

Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A 26.03.04 SEM 06.09.04 OMH 08.10.04 TH

The original signatures are recorded on the company’s logistic data system.

Document history
Rev. A First version.

Table of contents

1 INTRODUCTION ................................................................................................... 3

2 SPECIFICATIONS ................................................................................................. 4
2.1 Bearing Repeater, 360° Compass Card.............................................................. 4
2.2 Bracket for Bearing Repeater............................................................................. 5
2.3 Azimuth Device ................................................................................................. 5
2.4 Stand for Bearing Repeater ................................................................................ 5

3 INSTALLATION .................................................................................................... 6
3.1 Handling............................................................................................................. 6
3.2 Mechanical installation ...................................................................................... 6
3.2.1 Bearing Repeater into Bracket.................................................................... 6
3.2.2 Bearing Repeater Stand .............................................................................. 6
3.2.3 Bearing Repeater into Stand ....................................................................... 7
3.3 Electrical installation.......................................................................................... 7
3.3.1 Bearing Repeater in Bracket ....................................................................... 7
3.3.2 Bearing Repeater in Stand .......................................................................... 8

4 INSTALLATION DRAWINGS ............................................................................. 8

2 1001308/A
Installation Manual

1 INTRODUCTION
This document describes the installation of the Bearing Repeater.
The Bearing Repeater may be mounted on the wall/bulkhead using
a dedicated Bracket or in a dedicated Stand.
The guidelines for installation presented here must be regarded as a
base for detailed plans prepared by the installation shipyard. These
plans must include drawings, instructions and procedures specific
to the ship in which the equipment is to be installed. These
drawings must be approved by the local maritime classification
society.
Note Unless stated otherwise, all installation work described in this
document is to be performed by yard/customer personnel.
It is the responsibility of the yard/customer to assure that their
installation personnel are sufficiently qualified, and that proper
caution is taken to avoid injuries or damage to life, health,
environment, equipment and property.

Kongsberg Maritime AS accepts no responsibility for any damage


or injury to the system, ship or personnel caused by drawings,
instructions or procedures not prepared by Kongsberg Maritime.

1001308/A 3
Bearing Repeater 360° Compass Card, in Bracket or Stand

2 SPECIFICATIONS

2.1 Bearing Repeater, 360° Compass Card


For dimensions and data, refer to drawing number SC41214.

Mechanical specifications
Weight:................................................................................ 5.5 kg
Compass card diameter: ...................................360°card: 172 mm
Length of connection cable:.................................... Approx. 1.2m

Electrical specifications
Input voltage: ................................................................... 24 VDC
Batteries: ...............................................................................None
Maximum current consumption:...................................... 570 mA
Illumination:.....................................Red, 16 or 4 LEDs, 24 VDC
Bearing repeaters: ............................................. 360° illumination
Illumination “sync.” switch: .......................Red, 1 LED, 24 VDC
Drive: ..........................................Step motor 18 VDC to 36 VDC
.......................................................... 300 microsteps / 1° azimuth
Minimum magnetic clearance to:..................................................
- Standard magnetic compass:............................................. 0,70m
- Steering magnetic compass: ............................................. 0,45m
Minimum magnetic clearance (reduced) to: .................................
- Standard magnetic compass:............................................. 0,45m
- Steering magnetic compass: ............................................. 0,30m

Environmental specification
Enclosure protection: ............................................................IP 64
Humidity: ................................... Damp heat cycle, IEC 945/4.4.3
Vibration: ...................................... 5Hz to 50Hz to IEC 945/4.4.7
Immunity to conducted audio: ..... 50Hz to 10kHz to IEC 945/A3

4 1001308/A
Installation Manual

Frequencies: ..............................10kHz to 50MHz to IEC 945/A5


- Immunity to conducted audio frequencies is not specified for DC
appliances
- Test with power supply/rectifier and capacitor to IEC 945/A7
Conducted interference: .........10kHz to 30MHz to IEC 945/4.5.3
Radiated interference: ............30MHz to 300Hz to IEC 945/4.5.4
Acoustic noise:...... IEC 945/4.5.7 ≤65 dB(a) at a distance of 1 m
Magnetic clearance: ............................................................. 1.2 m
Operating Temperature: ..........................................-15° to +55°C
Storage Temperature:..............................................-25° to +70°C
Humidity: ..................................................................... IEC 60945

2.2 Bracket for Bearing Repeater


The Bracket includes a Connection box with a Dimmer.
For dimensions and data, refer to drawing number 507985 and
4884-0112-01.

2.3 Azimuth Device


For dimensions and weight, refer to Figure 1 Azimuth Device,
PV23, dimensions.

2.4 Stand for Bearing Repeater


The Stand includes a Connection box with a Dimmer.
For dimensions and data, refer to drawing number 4622-0112-02.

Electrical specifications
Input voltage: ................................................................... 24 VDC
Batteries: ...............................................................................None

Environmental specification
Enclosure protection: ............................................................IP 64
Operating Temperature: .........................................-10° to +55 °C
Operating Humidity: ........................................................ IEC 945
Storage Temperature:.............................................-25° to +70 °C
Storage Humidity: ............................................................ IEC 945

1001308/A 5
Bearing Repeater 360° Compass Card, in Bracket or Stand

3 INSTALLATION
This chapter describes the installation of the Bearing Repeater
using either a Bracket or a Stand.

3.1 Handling
Care should be taken when unpacking and handling the equipment.
A visual inspection should be made to check that the equipment has
not been damaged during shipment and that all components and
parts are present according to the packing list.
The equipment can be lifted by hand.
The equipment contains delicate electronic components – handle
accordingly.

3.2 Mechanical installation


3.2.1 Bearing Repeater into Bracket
Throughout installation of the Bearing Repeater into Bracket, refer
to attached drawings SC41214, 507985 and 4884-0112-01.
For mechanical installation of the Bearing Repeater into Bracket,
proceed as follows:
1 Decide the location of the Bracket.
Note Be aware of magnetic clearance minimum distances
refer to Electrical specifications in Bearing
Repeater section.
2 Drill holes for the Bracket in the bulkhead/wall according to
the installation drawing, refer to drawing 41203.
3 Place the Bracket in its position.
4 Use bolts, washers and nuts and fasten the Bracket to the
bulkhead/wall.
5 Place the Bearing Repeater in its position in the Bracket, refer
to drawings SC41214 and 507985.
6 Fit the Bearing Repeater into the mountings on the Bracket.
7 Electrical connection is performed according to section 3.3.1
Bearing Repeater in Bracket.

3.2.2 Bearing Repeater Stand


Throughout installation of the Bearing Repeater Stand, refer to
attached drawings 4622-0112-02 and 4884-0112-01.

6 1001308/A
Installation Manual

For mechanical installation of the Bearing Repeater Stand, proceed


as follows:
1 Decide the location of the Stand, i.e. where the cable from the
gyrocompass shall enter through the deck and into the centre
hole of the Stand.
Note Be aware of magnetic clearance minimum distances
refer to Electrical specifications section of the
Bearing Repeater, 360° Compass Card.
2 Place the Stand in its position and mark the position of the
holes in its bottom flange. Note that it shall be mounted in
along ship direction, with its Dimmer/Connection Box
pointing straight backwards, refer to drawing 4622-0112-02.
3 Remove the Stand and drill 22 mm holes in the deck at the
marked positions, refer to drawing 4622-0112-02.
4 Place the Stand in its position above the center hole.
5 Use bolts, washers and nuts and fasten the Stand to the deck.

3.2.3 Bearing Repeater into Stand


Throughout installation of the Bearing Repeater into Stand, refer to
drawings 4622-0112-02 and 4884-0112-01.
For mechanical installation of the Bearing Repeater into Stand,
proceed as follows:
1 Fit the Bearing Repeater into the mountings on the Stand.
2 Electrical connection is performed according to section 3.3.2
Bearing Repeater in Stand.

3.3 Electrical installation


For electrical installation of the Bearing Repeater, refer to the
Cable List and Cable Details documents for the actual project.
Cable termination and earthing details is described in the Earthing,
Screening and Power Supply Principles document (Kongsberg
document number 848-161012).

3.3.1 Bearing Repeater in Bracket


For electrical installation of the Bearing Repeater, in Bracket,
proceed as follows:
1 Enter the cable into the Connection Box on the Bracket; refer
to drawings 4881-0115-03 and 4884-0115-01.
2 Terminate the cable conductors according to project specific
cable details or to drawing 4881-0115-03.

1001308/A 7
Bearing Repeater 360° Compass Card, in Bracket or Stand

3 Seal the cable glands with self vulcanizing tape.

3.3.2 Bearing Repeater in Stand


For electrical installation of the Bearing Repeater, in Stand,
proceed as follows:
1 If applicable, pull the cable from the Switch-over unit
through the deck and through the centre hole of the Stand.
2 Enter the cable into the Connection Box of the Stand; refer to
drawings 4881-0115-03 and 4884-0115-01.
3 Terminate the cable conductors according to project specific
cable details or drawing 4881-0115-03.
4 Seal the cable glands with self vulcanizing tape.

4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:

Title Fig./Dwg. No. Rev. Sheets


C.Plath Bearing Repeater, IP66 ø225, Type 4881, Mech. SC41214 A 1
Det. Dwg.
Mechanical drawing. w/conn. box, type 4890/74520, 507985 A 1
C.Plath bearing rep.bracket
Azimuth Device, PV23, dimensions Figure 1 - -
Connection Box for Bearing Repeater 4884-0112-01 AA 1
Bearing Repeater Stand with Terminal Box 4622-0112-02 AA 1
Bearing Repeater, wiring 4881-0115-03 AD 1
Connection Box Bearing Repeater, wiring 4884-0115-01 AA 1

8 1001308/A
Installation Manual

1001308/A 9
Bearing Repeater 360° Compass Card, in Bracket or Stand

10 1001308/A
Installation Manual

Figure 1 Azimuth Device, PV23, dimensions

1001308/A 11
Bearing Repeater 360° Compass Card, in Bracket or Stand

12 1001308/A
Installation Manual

1001308/A 13
Bearing Repeater 360° Compass Card, in Bracket or Stand

14 1001308/A
Installation Manual

1001308/A 15
Installation Manual

Installation Manual
Universal Digital Repeater, flush
mounted
Kongsberg Part no.:
Universal Digital Repeater, flush mounted: 301250
Remote Dimmer (option): 4602435

This manual describes the installation of the Universal Digital


Repeater, flush mounted, supplied by C. Plath.

1001357/B 1
Universal Digital Repeater, flush mounted

Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A 22.03.04 SEM 31.03.04 OMH 19.08.04 TH
B 10.02.06 SEM 13.02.06 KEL 15.02.06 AAR

The original signatures are recorded on the company’s logistic data system.

Document history
Rev. A First version.
Rev. B Part number for Universal Digital Repeater changed from 700756 to 301250, and
Kongsberg dwg 507945 changed with C.Plath dwg 4891-0112-01.

Table of contents

1 INTRODUCTION ................................................................................................... 3

2 SPECIFICATIONS ................................................................................................. 4
2.1 Universal Digital Repeater, flush mounted........................................................ 4

3 INSTALLATION .................................................................................................... 5
3.1 Handling............................................................................................................. 5
3.2 Mechanical and electrical installation................................................................ 5
3.2.1 Universal Digital Repeater, flush mounted................................................. 5

4 INSTALLATION DRAWINGS ............................................................................. 6

2 1001357/B
Installation Manual

1 INTRODUCTION
This document describes the installation of the Universal Digital
Repeater, flush mounted.
The Universal Digital Repeater receives information from a serial
interface which is displayed in the form of a digital display. The
information displayed may be: heading, course to steer, speed, turn
rate, rudder angle and depth.
The Universal Digital Repeater may also convert information
received into a different protocol and send it to other used
appliances through a serial interface.

Note The guidelines for installation presented here must be regarded as


a base for detailed plans prepared by the installation shipyard.
These plans must include drawings, instructions and procedures
specific to the ship in which the equipment is to be installed. These
drawings must be approved by the local maritime classification
society.

Note Unless stated otherwise, all installation work described in this


document is to be performed by yard/customer personnel.
It is the responsibility of the yard/customer to assure that their
installation personnel are sufficiently qualified, and that proper
caution is taken to avoid injuries or damage to life, health,
environment, equipment and property.

Kongsberg Maritime AS accepts no responsibility for any damage


or injury to the system, ship or personnel caused by drawings,
instructions or procedures not prepared by Kongsberg Maritime.

1001357/B 3
Universal Digital Repeater, flush mounted

2 SPECIFICATIONS

2.1 Universal Digital Repeater, flush mounted


Refer to Kongsberg drawing 4891-0112-01 for dimensions and
specification.

Mechanical specifications
...........................................................Supplied with a 2.5 m cable

Electrical specifications
Power requirements: ...................................................18-36 VDC
Power consumption:................................................................7 W
Display: .....................................................two rows of dot matrix
........................................................... Upper: 4 units of 7 x 5 dots
........................................................... Lower: 5 units of 5 x 7 dots
Magnetic clearance: .............................................................. 0.3m
Signal input: ....................................................... one RS422 input
Protocols NMEA-0183: ................................................................
Heading gyro, heading magnetic, roll, pitch, rate of turn, X-rate, Y-
rate, water speed, ground speed, traverse water speed, traverse
ground speed, total/daily miles, wind speed, wind angle, rudder
angle, depth, air temperature, water temperature, time.................
Status input:.......opto-coupler. Rating 24V / 10mA, freeze mode,
............................................................180° heading change mode
Signal output: ..................................................................... RS422
Protocols VDR: .......specified for C.Plath Voyage Data Recorder
Status output:......................... Open collector, rating 50V/500mA
Status change according to speed input (threshold can be set in the
setup menu

Environmental specification
Enclosure protection: ................................................. IP65 (front)
.....................................................................................IP23 (back)
Vibration: ...................................... 5Hz to 50Hz to IEC945 / 16.5
Temperature Range: ................................................-25° to +70°C

4 1001357/B
Installation Manual

3 INSTALLATION
This chapter presents the procedures for installation of the
Universal Digital Repeater, flush mounted.

3.1 Handling
Care should be taken when unpacking and handling the equipment.
A visual inspection should be made to check that the equipment has
not been damaged during shipment and that all components and
parts are present according to the packing list.
The equipment can be lifted by hand.
The equipment contains delicate electronic components – handle
accordingly.

3.2 Mechanical and electrical installation


For electrical installation of the Universal Digital Repeater, flush
mounted, refer to the Cable List and Cable Details documents for
the actual project.
Cable termination and earthing details is described in the Earthing,
Screening and Power Supply Principles document (Kongsberg
document number 848-161012).

3.2.1 Universal Digital Repeater, flush mounted


For mounting of the Repeater, refer to Kongsberg drawing 4891-
0112-01.
1 When fitted, remove the retaining screws (1) and clamps (2)
from the housing of the Repeater.

2 Make a panel cut-out, refer to Kongsberg drawing 4891-


0112-01.
3 Fit the Repeater in the cut-out and lay the cable to the
terminal strip.

1001357/B 5
Universal Digital Repeater, flush mounted

4 Attach the retainer clamps (2) to the housing of the Repeater


and tighten the retaining screws (1) to secure the Repeater in
the console.
5 Connect the cable to the terminal strip designated for this
purpose according to the interconnection diagram, refer to
drawing 507631.
6 If the Remote Dimmer is to be installed (option), carry out
the following:
a At location from where the dimming is to be performed,
make holes and install according to drawing SC 41217.
b Connect the electrical leads according to drawings 507631
and SC41809.
7 The system is not to be energized at this point. A setup
procedure will be carried out at a later point.

4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:

Title Fig./Dwg. No. Rev. Sheets


Universal Digital Repeater, Watertight IP65 4891-0112-01 C 1 of 2
Digital Repeater C.Plath, Connection Diagram 507631 - -
Bridgeline Dimmer Digital Indicator C.Plath, Connection SC41809 C 1 of 1
Diagram

6 1001357/B
Installation Manual

1001357/B 7
Universal Digital Repeater, flush mounted

8 1001357/B
Installation Manual

1001357/B 9
Installation Manual

Installation Manual
Rate of Turn Indicator,
90deg./min, 144x144,
flush mounted
Kongsberg Part no.:
Rate of Turn Indicator: 309031
Dimmer (option): 4602426

This manual describes the installation of the Rate of Turn


Indicator, 90deg./min, 144x144, flush mounted (Supplier
stock no. 60369) supplied by C. Plath.

1001417/B 1
Rate of Turn Indicator, 90deg./min, 144x144, flush mounted

Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A 26.03.04 SEM 31.03.04 OMH 05.05.04 TH
B 18.01.07 SEM 19.01.07 TH 20.01.07 TH
The original signatures are recorded on the company’s logistic data system.

Document history
Rev. A First version.
Rev. B New PN for Rate of Turn Indicator, deleted drawing numbers 507744 and SC42074,
added figures 1 and 2.

Table of contents

1 INTRODUCTION ................................................................................................... 3

2 SPECIFICATIONS ................................................................................................. 3
2.1 ROT 90deg./min, flush mounted........................................................................ 3
2.2 Dimmer .............................................................................................................. 4

3 INSTALLATION .................................................................................................... 4
3.1 Handling............................................................................................................. 4
3.2 Mechanical installation ...................................................................................... 4
3.3 Electrical installation.......................................................................................... 5

4 INSTALLATION DRAWINGS ............................................................................. 5

2 1001417/B
Installation Manual

1 INTRODUCTION
This document describes the installation of the Rate of Turn (ROT)
Indicator, 90deg/ min, 144x144, flush mounted to be used with C.
Plath Gyro system, and the dimmer (option).
Note The guidelines for installation presented here must be regarded as
a base for detailed plans prepared by the installation shipyard.
These plans must include drawings, instructions and procedures
specific to the ship in which the equipment is to be installed. These
drawings must be approved by the local maritime classification
society.

Note Unless stated otherwise, all installation work described in this


document is to be performed by yard/customer personnel.
It is the responsibility of the yard/customer to assure that their
installation personnel are sufficiently qualified, and that proper
caution is taken to avoid injuries or damage to life, health,
environment, equipment and property.
Kongsberg Maritime AS accepts no responsibility for any damage
or injury to the system, ship or personnel caused by drawings,
instructions or procedures not prepared by Kongsberg Maritime.

2 SPECIFICATIONS
2.1 ROT 90deg./min, flush mounted
Supplier stock no:................................................................ 60369

Mechanical specifications
For dimensions and data, refer to Figure 1 Rate of Turn Indicator
(Supplier stock no. 60369), dimensions.

Electrical specifications
For electrical specifications, refer to Figure 1 Rate of Turn
Indicator (Supplier stock no. 60369), dimensions.

Environmental specification
Protection (front):..................................................................IP 56
Operating Temperature: .........................................-25° to +60 °C
Operating Humidity: ........................................................ IEC 945
Storage Temperature:.............................................-25° to +65 °C
Storage Humidity: ............................................................IEC 945

1001417/B 3
Rate of Turn Indicator, 90deg./min, 144x144, flush mounted

2.2 Dimmer

Mechanical specifications
For dimensions and data, refer to drawing number SC41207.

Electrical specifications
For electrical specifications, refer to drawing number SC41207.

3 INSTALLATION
This chapter presents the procedures for installation of the Rate of
Turn Indicator, 90deg/ min, 144x144, flush mounted

3.1 Handling
Care should be taken when unpacking and handling the equipment.
A visual inspection should be made to check that the equipment has
not been damaged during shipment and that all components and
parts are present according to the packing list.
The equipment can be lifted by hand.
The equipment contains delicate electronic components – handle
accordingly.

3.2 Mechanical installation


Throughout installation of the ROT, refer to attached drawing
Figure 1 and SC 41207.
For mechanical installation of the ROT proceed as follows:
1 Decide the location of the ROT.
Note Be aware of the magnetic clearance minimum
distance of 1 meter.
2 Cut a hole in the console according to the installation
drawing, Figure 1.
3 Place the ROT in its position.
4 Use applicable bolts, washers and nuts and fasten the ROT to
the console.
5 If the Remote Dimmer is to be installed (option), carry out
the installation according to SC41207.

4 1001417/B
Installation Manual

3.3 Electrical installation


Cable termination and earthing details is described in the Earthing,
Screening and Power Supply Principles document (Kongsberg
document number 161012).
For electrical installation of the ROT, proceed as follows:
1 Fit and connect all cables according to the information
supplied in the cable list. Refer also to drawings Figure 1 and
Figure 2.
2 If the Remote Dimmer is to be installed (option), carry out
the connection according to drawings SC41207 and Figure 2.
For additional electrical installation of the ROT, refer to the Cable
List and Cable Details documents for the actual project.

4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:

Title Fig./Dwg. No. Rev. Sheets


Rate of Turn Indicator (Supplier stock no. 60369), dimensions Figure 1 - 1
C.Plath Dimmer 24V 20W Type 4896, Watertight, Mech. Det. SC41207 B 1
Dwg
Rate of Turn Indicator with Dimming), connection diagram Figure 2 - 1

1001417/B 5
Rate of Turn Indicator, 90deg./min, 144x144, flush mounted

Figure 1 Rate of Turn Indicator (Supplier stock no. 60369), dimensions

6 1001417/B
Installation Manual

1001417/B 7
Rate of Turn Indicator, 90deg./min, 144x144, flush mounted

Figure 2 Rate of Turn Indicator with Dimming), connection diagram

8 1001417/B
Installation Manual

Installation Manual
Course and Rudder Angle
Recorder, NAVIPRINT
Kongsberg Part no.:
Course and Rudder Angle Recorder, NAVIPRINT:
703555

This manual describes the installation of the Course and


Rudder Angle Recorder, NAVIPRINT supplied by C. Plath.

1001419/B 1
Course and Rudder angle Recorder, NAVIPRINT

Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A 26.03.04 SEM 29.03.04 OMH 05.05.04 TH
B 28.01.05 SEM 31.01.05 OMH 04.02.05 TH

The original signatures are recorded on the company’s logistic data system.

Document history
Rev. A First version.
Rev. B Part no. has changed from 4601734 to 703555 because the supplier has changed its
Type no. from 77489 to 74490. This means also 4 new drawings in Installation
section.

Table of contents

1 INTRODUCTION ................................................................................................... 3

2 SPECIFICATIONS ................................................................................................. 4
2.1 Course and Rudder Angle Recorder, NAVIPRINT........................................... 4
2.2 Terminal Board .................................................................................................. 5

3 INSTALLATION .................................................................................................... 5
3.1 Handling............................................................................................................. 5
3.2 Mechanical and electrical installation................................................................ 5
3.2.1 Course and Rudder Angle Recorder, NAVIPRINT.................................... 6
3.2.2 Terminal Board ........................................................................................... 6

4 INSTALLATION DRAWINGS ............................................................................. 6

2 1001419/B
Installation Manual

1 INTRODUCTION
This document describes the installation of the Course and Rudder
Angle Recorder, NAVIPRINT.
The Course and Rudder Angle Recorder, NAVIPRINT supplies the
user with printed recordings of the vessel’s heading and rudder
angle, and may also print a selection of additional data.

WARNING The equipment includes high voltage (115/230V) which means


that the possibility for getting an electrical shock is present.

Note The guidelines for installation presented here must be regarded as


a base for detailed plans prepared by the installation shipyard.
These plans must include drawings, instructions and procedures
specific to the ship in which the equipment is to be installed. These
drawings must be approved by the local maritime classification
society.

Note Unless stated otherwise, all installation work described in this


document is to be performed by yard/customer personnel.
It is the responsibility of the yard/customer to assure that their
installation personnel are sufficiently qualified, and that proper
caution is taken to avoid injuries or damage to life, health,
environment, equipment and property.

Kongsberg Maritime AS accepts no responsibility for any damage


or injury to the system, ship or personnel caused by drawings,
instructions or procedures not prepared by Kongsberg Maritime.

1001419/B 3
Course and Rudder angle Recorder, NAVIPRINT

2 SPECIFICATIONS

2.1 Course and Rudder Angle Recorder, NAVIPRINT


For specifications, refer to Kongsberg drawing 508272.

Mechanical specifications
Voltage supply cable:........................................................... 2.3 m
Terminal board cable: ............................................................. 3 m

Electrical specifications
Input voltage: ................................................................. 230 VAC
Power consumption:...................................................max. 70 VA
Batteries: ...............................................................................None
Interface: ............................................................................ RS422
Paper feed speeds:........................................60, 150 or 600 mm/h
Heading recording range:........±30° or ±180° (same paper width)
Rudder angle recording range:..........................±9°, ±45° or ±70°
Status line comprising the following (for Navigat X Mk1):.........
- DATE 16.01.04:.....................................................DD.MM.YY
- LAT: 53:35:05N: ........................................................... latitude
- LON: 167:43:29E: .............. longitude (only from an automatic
...........................................................……input. e.g. GPS)
- ST.M.A: ......................... steering mode (M=Manual, A= Auto)
- DIFF.AL: 20: .......alarm threshold between two headings (20°)
- M.VAR: 10.0: .................................. magnetic variation (10.0°)
- SPD: 18.7:.................................. ship’s speed in knots (18.7 kt)
- G1: 120.8: ................................... heading from gyro 1 (120.8°)
- G2: 120.8: ................................... heading from gyro 2 (120.8°)
- MAG: 119.7:............ heading from magnetic compass (119.7°)
- SRC: G1:............... heading source (Magnetic, Gyro 1, Gyro 2)
- COR: +2.8:........................ north speed error correction (+2.8°)
- TIME 11:25: ............................................ over the time column
Type approval: ................................................. BSH/40/31G/1/94

4 1001419/B
Installation Manual

Environmental specification
Operating Temperature: ............................................ 5° to +35 °C
Storage Temperature:.............................................-30° to +60 °C
Humidity: ............................................................ 30% to 60% RH

2.2 Terminal Board


For specifications, refer to Kongsberg drawing 508273.

Electrical specifications
Supplies data signals to the Course and Rudder Angle Recorder.
Cable connector: ........................................................25 pin Dsub
Batteries: ...............................................................................None

3 INSTALLATION
This chapter presents the procedures for installation of the Course
and Rudder Angle Recorder, Naviprint.

3.1 Handling
Care should be taken when unpacking and handling the equipment.
A visual inspection should be made to check that the equipment has
not been damaged during shipment and that all components and
parts are present according to the packing list.
If applicable, equipment can be lifted by hand.
The equipment contains delicate electronic components – handle
accordingly.

3.2 Mechanical and electrical installation


For electrical installation of the equipment, refer to the Cable List
and Cable Details documents for the actual project.
Cable termination and earthing details is described in the Earthing,
Screening and Power Supply Principles document (Kongsberg
document number 848-161012).

1001419/B 5
Course and Rudder angle Recorder, NAVIPRINT

3.2.1 Course and Rudder Angle Recorder, NAVIPRINT


The Course and Rudder angle Recorder may be installed in two
ways, either wall mounted or desk mounted. For either method,
refer to Kongsberg drawing 508274.
For electrical installation of the recorder, refer to Kongsberg
drawings 508272 and 508275.

3.2.2 Terminal Board


The terminal board is to be installed at a suitable location inside the
bridge console or other cabinet.
For installation, refer to Kongsberg drawings 508272, 508273 and
to 508275.

4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:

Title Fig./Dwg. No. Rev. Sheets


C.Plath Voyage Data Recorder, Type 4895, Mech. Det. 508272 A 1 of 1
Dwg, Std. dwg
C.Plath Voyage Data Recorder, Type 4895, Mech. Det. 508273 A 1 of 1
Dwg, Std. dwg
C.Plath Voyage Data Recorder, Type 4895, Mech. Det. 508274 A 1 of 1
Dwg, Std. dwg
Bridgeline course & rudder angle printer, C.Plath, 508275 A 1 of 1
connection diagram

6 1001419/B
Installation Manual

1001419/B 7
Course and Rudder angle Recorder, NAVIPRINT

8 1001419/B
Installation Manual

1001419/B 9
Course and Rudder angle Recorder, NAVIPRINT

10 1001419/B
Installation Manual

Installation Manual
Universal Digital Repeater,
bulkhead/desk mounted
Kongsberg Part no.:
Universal Digital Repeater, bulkhead/desk mounted:
301251
Remote Dimmer (option): 4602435

This manual describes the installation of the Universal Digital


Repeater, bulkhead/desk mounted, supplied by C. Plath.

1001359/C 1
Universal Digital Repeater, bulkhead/desk mounted

Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A 26.03.04 SEM 31.03.04 OMH 19.08.04 TH
B 17.03.05 SEM 18.03.04 OMH 18.03.05 TH
C 10.02.06 SEM 13.02.06 KEL 15.02.06 AAR

The original signatures are recorded on the company’s logistic data system.

Document history
Rev. A First version.
Rev. B The drawing 507942 has been updated with Kongsberg drawing number 1004986.
Rev. C Part number for Universal Digital Repeater changed from 700213 to 301251, and
Kongsberg dwg 1004986 changed with C.Plath dwg 4891-0112-02.

Table of contents

1 INTRODUCTION ................................................................................................... 3

2 SPECIFICATIONS ................................................................................................. 4
2.1 Universal Digital Repeater, bulkhead/desk mounted......................................... 4

3 INSTALLATION .................................................................................................... 5
3.1 Handling............................................................................................................. 5
3.2 Mechanical and electrical installation................................................................ 5
3.2.1 Universal Digital Repeater, bulkhead/desk mounted ................................. 5

4 INSTALLATION DRAWINGS ............................................................................. 6

2 1001359/C
Installation Manual

1 INTRODUCTION
This document describes the installation of the Universal Digital
Repeater, bulkhead/desk mounted. The housing is water tight.
The Universal Digital Repeater receives information from a serial
interface which is displayed in the form of a digital display. The
information displayed may be: heading, course to steer, speed, turn
rate, rudder angle and depth.
The Universal Digital Repeater may also convert information
received into a different protocol and send it to other used
appliances through a serial interface.

Note The guidelines for installation presented here must be regarded as


a base for detailed plans prepared by the installation shipyard.
These plans must include drawings, instructions and procedures
specific to the ship in which the equipment is to be installed. These
drawings must be approved by the local maritime classification
society.

Note Unless stated otherwise, all installation work described in this


document is to be performed by yard/customer personnel.
It is the responsibility of the yard/customer to assure that their
installation personnel are sufficiently qualified, and that proper
caution is taken to avoid injuries or damage to life, health,
environment, equipment and property.

Kongsberg Maritime AS accepts no responsibility for any damage


or injury to the system, ship or personnel caused by drawings,
instructions or procedures not prepared by Kongsberg Maritime.

1001359/C 3
Universal Digital Repeater, bulkhead/desk mounted

2 SPECIFICATIONS
2.1 Universal Digital Repeater, bulkhead/desk
mounted
Refer to Kongsberg drawing number 4891-0112-02 for dimensions
and specification of the water tight housing with bracket
attachment.

Mechanical specifications
...........................................................Supplied with a 2.5 m cable

Electrical specifications
Power requirement: .....................................................18-36 VDC
Power consumption:................................................................7 W
Display: .....................................................two rows of dot matrix
........................................................... Upper: 4 units of 7 x 5 dots
........................................................... Lower: 5 units of 5 x 7 dots
Magnetic clearance: .............................................................. 0.3m
Signal input: .................................................................one RS422
Signal output: ...............................................................one RS422
Protocols NMEA-0183: ................................................................
Heading gyro, heading magnetic, roll, pitch, rate of turn, X-rate, Y-
rate, water speed, ground speed, traverse water speed, traverse
ground speed, total/daily miles, wind speed, wind angle, rudder
angle, depth, air temperature, water temperature, time.................
Status input:.......opto-coupler. Rating 24V / 10mA, freeze mode,
............................................................180° heading change mode
Protocols VDR: .......specified for C.Plath Voyage Data Recorder
Status output:......................... Open collector, rating 50V/500mA
Status change according to speed input (threshold can be set in the
setup menu.

Environmental specification
Enclosure protection: ................................................. IP65 (front)
.....................................................................................IP23 (back)
Vibration: ...................................... 5Hz to 50Hz to IEC945 / 16.5
Temperature range: .................................................-25° to +70°C

4 1001359/C
Installation Manual

3 INSTALLATION
This chapter presents the procedures for installation of the
Universal Digital Repeater, bulkhead mounted.

3.1 Handling
Care should be taken when unpacking and handling the equipment.
A visual inspection should be made to check that the equipment has
not been damaged during shipment and that all components and
parts are present according to the packing list.
The equipment can be lifted by hand.
The equipment contains delicate electronic components – handle
accordingly.

3.2 Mechanical and electrical installation


For electrical installation of the Universal Digital Repeater,
bulkhead/desk mounted, refer to the Cable List and Cable Details
documents for the actual project.
Cable termination and earthing details is described in the Earthing,
Screening and Power Supply Principles document (Kongsberg
document number 848-161012).

3.2.1 Universal Digital Repeater, bulkhead/desk mounted


For installation of the Repeater, refer to Kongsberg drawing
number 4891-0112-02.
Note The Repeater is assembled at delivery from supplier.
1 Connect the cable to the terminal strip designated for this
purpose according to the interconnection diagram, refer to
drawing 507631.
2 If the Remote Dimmer is to be installed (option), carry out
the following:
a At location from where the dimming is to be performed,
make holes and install according to Kongsberg drawing
number 4891-0112-02.
b Connect the electrical leads according to drawings 507631
and SC41809.
3 The system is not to be energized at this point. A setup
procedure will be carried out at a later point.

1001359/C 5
Universal Digital Repeater, bulkhead/desk mounted

4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:

Title Fig./Dwg. No. Rev. Sheets


Universal Digital Repeater , watertight IP65 4891-0112-02 0A 1 of 2
BridgeLine Digital Repeater C.Plath, Connection 507631 A 1 of 1
Diagram
Bridgeline Dimmer Digital Indicator C.Plath, Connection SC41809 C 1
Diagram

6 1001359/C
Installation Manual

1001359/C 7
Universal Digital Repeater, bulkhead/desk mounted

8 1001359/C
Installation Manual

1001359/C 9
Kongsberg Maritime
C.Plath Universal Digital
Repeater, Operator, Technical,
Installation and Service Manual

Supplier: C.Plath
Reference: 056296 01 Oct 97
Version: B

173528/B