Download as pdf
Download as pdf
You are on page 1of 4
§ yanall Gus poll jlion 6S yy *& Standard Arabia Inspection Co Ltd. TESTING AND CAI ON UO aRe 71 cd Ad 08 TI (CH No MSSINLE, COC Na THD ewtodordrioc + 966-3752 680 [+ 96619967 02 CALIBRATION CERTIFICATE CERTIFICATE NO: 23-2268-4236 Hever et CLIENT EXPERTISE CONTRACTING CO. LTD DATE 27 April 2023 “ADDRESS: : Jubail, KSA ‘WORK ORDER NO. 23-2268 [ CALIBRATED ITEM. RELAY TEST SYSTEM INSTRUMENT IDENTIFICATION MANUFACTURER MEGGER MODEL / SERIAL NO. FREIA546/201608070001 RANGE Various RESOLUTION Various SPECIFICATION LIMIT As Per Manufacturer's Specification CALIBRATION DETAILS CALIBRATION DATE 27 April 2023, CALIBRATION DUE DATE 26 April 2024 CALIBRATION LOCATION SAICT&C, Al Jubail CALIBRATED BY AL STANDARD ARABIA INSPECTION CO, LTD, Testing and Calibration Division certify that the above product meets measurement specifications and has been calibrated using standards traceable to international standards. The policies and procedures used at the calibration facility are based on ISO/IEC 17025:2017. This certificate shall not be reproduced other than in full except with prior written permission of the Calibration facility. REVIEWED BY a ‘Suresh Kumar Supervisor ‘Quality Manager The copyright ofthis documents owned by Standard Arabia spection company Li 1 may not he reproduced excep in ful wth prior written approval rm the compar. arenes Isue os 1 iesue date: 4 Api 2029 eyo :1 Revdate:8 uy, 2022 & 8 STANDARD jan CALIBRATION RESULTS Page 2 04 CERTIFICATE NO: 23-2268-4236 CALIBRATION PROCEDURE =: SATC-CM-11 CALIBRATION REFERENCE © User Manual CALIBRATION DATA ‘AC CURRENT LINE 1 Nominal Value | Measured Value Error Parameter hae) AMS ‘Trial 1 (AAC) | Trial2 (AAC) | Trial3 (AAC) | Mean (AAC) | (4) 1.00 1.0167 1.0168 1.0167 10167 | 1.670 niasies 3.00 3.0053, 3.0054 3.0052 3.0053 | 0.180 5.00 5.0046 5.0045, 5.0043 5.0080 | 0.080 35.00 15.000 15,000 15.000 15.000 | 0.000 ‘AC CURRENT -LINE 2 Nominal Value ~ Measured Value Error pararoaber es ANG | Trial 1 (AAC) | Trial2 (aac) ‘Trial 3 (AAC) | Mean (AAC) 6) F 1.00 = 0.9987 0.9987, 0.9987 0.9987 0.1300 BYyisiees 3.00 3.0054 3.0084 | 3.0054 3.0054 | 0.180 5.00 5.0016 5.0016 5.0016 5.0016 | 0,032 15.00 15.000 | 15.000 15.000 15.000 0.000 3. ACCURRENT-LINE3 Nominal Value Measured Value Error Paraimetet ABP ARC Trial 1 (AAC) | Trial2 (AAC) | Trial3(AAC) | Mean (aac) (4) 1.00 1.0012 1.0012 1.0012 10012 | 1.001 3.00 3.0030 3.0030, 3.0030 3.0030 | 0.100 Oo AAG 5.00 5.0012 5.0012, 5.0012 5.0012 0.024 15.00 15,000 15,000 15,000. 15.000 0.000 The copyright ofthis documents ewe by Standard Avaba Inspection company tt may not be reproduced except in ful ith rir written approval from the company iarercas Issue: ssue date: 2 Apr 2019, Revo 20 STANDARD jes CALIBRATION RESULTS Page sod CERTIFICATE NO: 23-2268.4236 AC VOLTAGE -LINE 4 if Nominal Value Measured Value Error Parameter AAC NDE Trial 1 (AAC) | Trial 2 (AAC) | Trial3 (AAC) | Mean (aac) | (%) 1.00 10167 1.0168 i017 | 1.0167 | 1.670 10.00 10.0053 | 10.0054 10.0052 | 10.0053 | _0,053 pean 150.00 150.954 | 150954 | 150.954 | 150.954 | 0.636 250.00 250.956 | 250956 | 250956 | 250.956 | 0.382 AC VOLTAGE -LINE 2 "| Nominal Value Measured Value Error PATaMataL Ane, vac Trial 1 (AAC) | Trial 2 (AAC) | Trial3 (AAC) | Mean (AAC) (%) “100 1.0037 1.0037 10037 1.0037 | 1.370 10.00 10.0044, 10.0044, 10.0044 | 10.0044 0.044 PEAS 150.00 150.954 | 150.954 | 150954 | 150.954 | 0.636 iy 250.00 250.956 | 250.956 | 250.956 0.956 | 0.382 5. AC VOLTAGE -LINE 3 ‘Nominal Value Measured Value Error Foramener ASG vac Trial 1 (AAC) | Trial2 (AAC) | Trial3(AAC) | Mean (aac) | (%4) 1.00 10124 a0124 10124 aoiza | 1.240 10.00 10.0044 | 10.0044 10.004 10.0044 | 0.044 pee 150.00 150.954 150.954 150.954 150.954 | 0.636 250.00 250.956 | 250.956 | 250.956 250.956 | 0.382 The copyright ofthis document is owned by Standard Arabia Inspection company Lt. may nat be reproduced except i fal with prior written approval rom the company. saTCRCIS Issue No! 1 tssue dae: 1 Apr 2019 Revo. :0 > vo. STANDARD joys CALIBRATION RESULTS Page 4of4 CERTIFICATE NO: 23-2268-4236 DETAILS OF REFERENCE DEVICE DEVICE DETAILS : True Rms Multimeter, Calibration Box -2 IDENTIFICATION NO. 83-286, 83-485 CERTIFICATE TRACEABILITY + The instrument was calibrated using master equipment traceable to National / International Standards. CALIBRATION EXPIRY DATE +: 20 July 2024, 10 Novernber 2024 The copii ofthis documents owned by Standard Arabia inspection company dit may not he reproduce except nul with pir tan approval inthe company Sarercas Issue Mo: sue date: 4 Api, 2039 Revo 20

You might also like