Technical Data - Fan Model AP0714AA10/27

Location: Designation:

Performance - Required Actual


Air Flow : 10002 cfm Air Flow: 10149 cfm
Static Pressure : 1.00 in WG Static Pressure: 1.03 in WG
Selection Pressure: 1.00 in WG Total Pressure: 1.38 in WG
Installation Type: TYPE D
Air Density: 1.204 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0714AA10/27 (AP0714AA10B030)
Description: AP Series In-Line Direct Drive
Diameter: 710 mm Hub: 150 mm
Impeller Type: Axial Pitch: 27°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz
Power, Abs: 2.40 kW Form: B
Input Power: 2.74 kW Peak: 2.42 kW
Efficiency Total: 68.6%
Fan Weight: 86.0 kg Static: 51.1%

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D100L
Motor Power: 3.00kW
FLC/Start: 6.20A / 35.96A
Motor Speed: 4 pole
Motor Efficiency: 87.8%

Energy Efficiency, NCC/BCA Vol. 1, Section J compliant


+ 2006 - 2009, 2013 - 2016, 2019

Energy Efficiency, H1/VM3 2021 compliant


+ H1/VM3 2021

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 88 78 83 84 85 82 78 67 92 68
Outlet (dB): 90 80 83 83 86 84 81 77 94 70
Breakout (dB): 86 71 69 65 63 57 48 44 86 48
Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.
Fan Breakout Sound Power Levels exclude the breakout from any attached ductwork or flexible connections and are calculated from the Inlet and
Outlet Sound Power Levels, considering the Sound Reduction Index of the Fan Casing.

As part of our continuous improvement processes, Fantech reserves the right to Printed 10/13/2023 11:12:51 AM
make changes in design or specification to products without notice.
Represented by:
PT. Multitek Indopanca
Wisma Bisnis Indonesia
14th Floor #1411
Jl. Let. Jend. S. Parman Kav. 12
Jakarta 11480
Telephone: +62 (021) 5366 1985
Facsimile: +62 (021) 5366 1986
Version 5.7.12 Copyright © 2010-23 Elta Group

Drawing for Fan Model AP0714AA10/27

Location: Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 10/13/2023 11:12:51 AM
make changes in design or specification to products without notice.
HPA SERIES
Plate Mounted Fan
HPA SERIES
All impeller blades are pressed steel sickle bladed type with
the exception of HPA 250mm and 300mm models which
are conventional pressed steel blades, all providing excellent
performance characteristics and low noise levels. Impellers are
epoxy painted colour RAL 9005 black and are welded to the
motor rotor.

Motor
Type - external rotor motors.
Electricity supply - 230V, single phase, 50Hz or 400V, three-
phase, 50Hz.
Bearings - sealed for life, ball.
Description See page O-2/3 for details on these motors.
The plate mounted HPA Series are designed around an advanced,
Internal Thermal Protection
high performing impeller. Suitable for a wide range of air supply
and discharge applications. The HPA axial fans offer a wide Model 200 to 710 single phase - Integral thermal overload
operating angle making them suitable for mounting in any position protection.
enabling greater flexibility for site installations. Available in 9 Model 200 to 710 three phase - Integral thermal overload
standard sizes from 250mm to 710mm, either single or three protection.
phase.
Testing
Typical Applications Airflow to ISO 5801:1997
Suitable for a wide range of air supply applications in the building Noise to BS848 Part 2:1985
services sector such as warehousing, restaurants, sports halls,
industrial units, schools and kitchen extract to agricultural markets.

Features
Suggested Specification
• Finished in a tough epoxy paint to protect against corrosion. The HPA plate mounted fan shall be of the HPA Series by Elta
Fans. It shall have a one piece bell mouth inlet and mounting
• Highly efficient external rotor motors.
plate manufactured in powder coated steel. It shall include a
• Very efficient for moving high volumes of air at relatively low finger protection guard to IS013582 for mounting the fan onto
pressures. Can achieve air volume flow rates of up to 4.0 m³/ the inlet ring. Guards are to be electroplated prior to painting and
sec and static pressures of up to 300Pa. finished in an epoxy polyester paint RAL 9005 Black.
• Bell mouth inlet reduces resistance to create a smoother The fan must be built with external rotor motors with sealed
airflow. for life, maintenance free, ball bearings enabling the fan to be
• The HPA is fully speed-controllable allowing levels of ventilation mounted at any angle. Motors are to be IP44 with Class F
to be adjusted according to requirements and eliminating insulation, suitable for ambient operating temperatures of up to
wasted energy expenditure. +55° C and 95% humidity. All motors are pre-wired to an IP54
• Motors and impellers are balanced to Grade G6.3.
terminal box, incorporate built in thermal overload protection and
are suitable for speed control. Motors and impellers are balanced
• Motor mounting brackets are constructed within welded wire to Grade G6.3. All performance shall be based upon tests to
framework which acts as a finger guard. ISO 5801:1997 for airflow and to BS848 Part 2:1985 for noise.
• The mounting brackets are electroplated prior to black epoxy All performance and sound data to be based on Form A Plate
powder coating to provide added protection. Mounted test arrangement.
• Suitable for operating temperatures of up to +55°C and up to
95% humidity.
• Condensation drainage holes are built into the motors as How To Order
standard. These remove the build up of condensation within
the motor when operating in humid surroundings or from HPA / - A
considerable changes in temperature. HPA - HPA Series
• Motors have sealed for life bearings designed to operate at
200 to 710 - Fan size
any angle.
• Built-in integral thermal overload protection which prevents the 2, 4 or 6 - Number of poles
motor from overheating.
1 or 3 - Electrical phase
• Rated IP44 which means they are highly resistant to dust and
water ingress.
• IP54 terminal box and motor side guard.
• Motors have Class F insulation. Comes a 12 month warranty
as standard.

Construction
Bell mouth inlet and mounting plate manufactured in powder
coated steel. Finished in a tough epoxy paint to protect against
corrosion. Mounting brackets are electroplated prior to black
epoxy powder coating. Guards are electroplated prior to painting
and finished in a tough epoxy polyester paint RAL 9005 Black.

© Elta Fans Asia 2018


HPA SERIES
Technical Data
Model Fan Avg. 220-240V/1Ph/50Hz App.
Number Speed, dB(A) FLC SC Wt.
HPA... rev/sec @ 3m Watts Amps Amps kg
200/2-1A 38 41 55 0.26 0.80 2.5
250/2-1A 40 51 80 0.40 1.20 3.0
315/2-1A 38 51 145 0.66 2.00 3.3
250/4-1A 23 46 50 0.23 0.70 3.0
315/4-1A 22 49 75 0.35 1.10 3.3
350/4-1A 23 53 140 0.65 2.00 4.9
400/4-1A 23 59 180 0.82 2.5 7.2
450/4-1A 22 59 250 1.20 3.6 7.2
500/4-1A 21 63 420 1.95 5.9 9.5
560/4-1A 21 66 550 2.55 7.7 10.5
400/6-1A 15 49 110 0.50 1.50 7.2
450/6-1A 15 51 150 0.70 2.10 7.2
500/6-1A 15 59 230 1.15 3.50 9.5
560/6-1A 15 61 330 1.70 5.10 10.5
630/6-1A 15 66 520 2.50 7.50 15.0
500/4-3A 21 63 450 0.90 2.70 9.5
560/4-3A 21 75 600 1.20 3.60 10.5
630/4-3A 22 69 800 1.60 4.80 15.0
500/6-3A 15 59 230 0.55 1.7 9.5
560/6-3A 15 61 330 0.90 2.7 10.5
630/6-3A 15 66 550 1.60 4.8 15.0
710/6-3A 15 71 900 1.90 5.7 25.0

Dimensions

E

AØ BØ CØ

G H
4 Holes 10Ø F

Model
Number Dimensions, mm
HPA... AØ BØ CØ DØ E F G H
200/*-**A 200 210 215 312 260 52 60 15
250/*-**A 250 260 265 370 320 90 60 15
315/*-**A 315 325 360 430 380 90 60 15
350/*-**A 350 360 395 485 435 90 60 15
400/*-**A 400 410 450 540 490 110 60 15
450/*-**A 450 460 500 575 535 110 60 15
500/*-**A 500 510 560 655 615 115 60 15
560/*-**A 560 575 625 725 670 115 60 15
630/*-**A 630 645 705 805 750 125 60 20
710/*-**A 710 725 765 850 810 130 135 27
* Add 2, 4 or 6 for number of poles
** Add 1 or 3 for electrical phase
© Elta Fans Asia 2018
HPA SERIES
200 2 Pole 175 6 Pole

175 150

150
125

HP 00/6 A450 A40


HP

HP

HP
125

A5
A20

A6
A5
100

60

30
0/2

HP

/6-

/
100

6-
A3 A

1A
1A
-1A

-1
15 75

HP
75 /2-
HP 1A
A2 50
50

HP

/6 0/6
50 /2

-1
-1

A
A 25
25

-1A
0 0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.00 0.50 1.00 1.50 2.00 2.50 3.00

175 4 Pole 300 4 Pole


275
150 250

HP
225
HP

125

A6
A3
HP

200

30
50

/4
A31

/4

-3
100 A 175
-1

A
HPA

5/4-

150
1A
250

75 125
HP
/4-1

A5

100
60

50
HP
A

75
/4-
A5

3A
00

25 50
/4-

25
3A

0 0
0.00 0.20 0.40 0.60 0.80 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50

150 4 Pole 200 6 Pole

175
125
HP HPA

HP
A4

150 A7
50

1A 10
/4

100 /6
-3
-

125 A
40

HP
HPA
HP
HP
0/4

A6
A5

A50

30
560

75 100
-1

/6
0/4
A

0/6

-3
/6-3
HP
-

A
-3A
1A

75
A5

50
A
60

50
/4-
1A

25
25

0 0