RFLAB2

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 8

R=10

Vout
L
R L1
R1 L=12.6 uH
R
R=1000 Ohm R=
R2
C C R=50 Ohm
C1 C2
C=1.05 nF C=4.24 nF
AC
V_AC AC
SRC1 AC1
Vac=polar(1,0) V Start=0 MHz
Freq=1.5 MHz Stop=3 MHz
Meas
Eqn MeasEqn Step=6.25 kHz
Meas1
Pload=(Vout*Vout)/50

0.00025

0.00020
mag(Pload)

0.00015

0.00010

0.00005

0.00000
0.0 0.5 1.0 1.5 2.0 2.5 3.0

freq, MHz
R=20
Vout
L
R L1
R1 L=17.3 uH
R
R=1000 Ohm R=
R2
C C R=50 Ohm
C1 C2
C=0.74 nF C=2.5 nF
AC
V_AC AC
SRC1 AC1
Vac=polar(1,0) V Start=0 MHz
Freq=1.5 MHz Stop=3 MHz
Meas
Eqn MeasEqn Step=6.25 kHz
Meas1
Pload=(Vout*Vout)/50

0.00025

0.00020
mag(Pload)

0.00015

0.00010

0.00005

0.00000
0.0 0.5 1.0 1.5 2.0 2.5 3.0

freq, MHz

R=30
Vout
L
R L1
R1 L=20.3 uH
R
R=1000 Ohm R=
R2
C C R=50 Ohm
C1 C2
C=0.59 nF C=1.73 nF
AC
V_AC AC
SRC1 AC1
Vac=polar(1,0) V Start=0 MHz
Freq=1.5 MHz Stop=3 MHz
Meas
Eqn MeasEqn Step=6.25 kHz
Meas1
Pload=(Vout*Vout)/50

0.00025

0.00020
mag(Pload)

0.00015

0.00010

0.00005

0.00000
0.0 0.5 1.0 1.5 2.0 2.5 3.0

freq, MHz

R=40
Vout
L
R L1
R1 L=22.9141 uH
R
R=1000 Ohm R=
R2
C C R=50 Ohm
C1 C2
C=0.5198 nF C=1.06103 nF
AC
V_AC AC
SRC1 AC1
Vac=polar(1,0) V Start=0 MHz
Freq=1.5 MHz Stop=3 MHz
Meas
Eqn MeasEqn Step=6.25 kHz
Meas1
Pload=(Vout*Vout)/50

0.00025

0.00020
mag(Pload)

0.00015

0.00010

0.00005

0.00000
0.0 0.5 1.0 1.5 2.0 2.5 3.0

freq, MHz

COMBINED
0.00025

0.00020
mag(RFPRELAB2..Pload)
mag(PRELABT3..Pload)
mag(PRELABT2..Pload)

mag(Pload)

0.00015

0.00010

0.00005

0.00000
0.0 0.5 1.0 1.5 2.0 2.5 3.0

freq, MHz

Post lab

R=100

Vout
L
R L1
R1 L=46 uH
R
R=1000 Ohm R=
R2
C C R=50 Ohm
C1 C2
C=0.318 nF C=3.18 nF
AC
V_AC AC
SRC1 AC1
Vac=polar(1,0) V Start=0 MHz
Freq=1.5 MHz Stop=3 MHz
Meas
Eqn MeasEqn Step=6.25 kHz
Meas1
Pload=(Vout*Vout)/50
0.00012

0.00010

0.00008
mag(Pload)

0.00006

0.00004

0.00002

0.00000
0.0 0.5 1.0 1.5 2.0 2.5 3.0

freq, MHz

R=500

Vout
L
R L1
R1 L=68.9 uH
R
R=1000 Ohm R=
R2
C C R=50 Ohm
C1 C2
C=0.106 nF C=0.63 nF
AC
V_AC AC
SRC1 AC1
Vac=polar(1,0) V Start=0 MHz
Freq=1.5 MHz Stop=3 MHz
Meas
Eqn MeasEqn Step=6.25 kHz
Meas1
Pload=(Vout*Vout)/50
0.00008

0.00007

0.00006

0.00005
mag(Pload)

0.00004

0.00003

0.00002

0.00001

0.00000
0.0 0.5 1.0 1.5 2.0 2.5 3.0

freq, MHz

Vout
L
R L1
R1 L=139.1 uH
R
R=1000 Ohm R=
R2
C C R=50 Ohm
C1 C2
C=0.053 nF C=0.33 nF
AC
V_AC AC
SRC1 AC1
Vac=polar(1,0) V Start=0 MHz
Freq=1.5 MHz Stop=3 MHz
Meas
Eqn MeasEqn Step=6.25 kHz
Meas1
Pload=(Vout*Vout)/50
0.00005

0.00004
mag(Pload)

0.00003

0.00002

0.00001

0.00000
0.0 0.5 1.0 1.5 2.0 2.5 3.0

freq, MHz

Combined circuit

0.00025

0.00020
mag(postlab2t3..Pload)
mag(postlab2t2..Pload)
mag(postlab2t1..Pload)
mag(Pload)

0.00015

0.00010

0.00005

0.00000
0.0 0.5 1.0 1.5 2.0 2.5 3.0

freq, MHz

You might also like