520AID01 data sheet 1KGT 150 866 Aquisition mode Integrated AMI, MFI - PDP parameters
threshold su-
pervision
Operation Aquisition mode:
– Integrated threshold supervision
The 520AID01 module records up to 6 analog measured values. – absolute threshold supervision
– periodic update
The module is available in two versions (rubrics): – Integrated threshold + periodic update
– R0001: Current measurement version
– R0002: Voltage measurement version
For additional information on these configuration parameters in
RTUtil500 refer to RTU500 series function description - part 5:
SCADA functions .
Processing functions
Scan cycle and line frequency interferance suppression
The module 520AID01 is able to process the following types of
signals:
Beside the information about the configured measuring range
– Analog measured values (AMI)
the information about the line frequency is required for the A/D-
– Measured floating point information (MFI)
conversion. The scan cycle time is determined by the AC line
frequency:
The micro-controller on the module processes all time critical
tasks of the parameterized processing functions. Moreover it
carries out the interactive communication with the RTU I/O bus. Frequency Conversion time per Scan cycle time
All configuration data and processing parameters are loaded by channel (same for all chan-
60 Hz 50 ms 400 ms
The analog input unit can execute the following processing
50 Hz 60 ms 480 ms
functions on the measured values:
– Scan cycle and line frequency interference suppression 16.7 Hz 200 ms 1600 ms
Parameter name Default Parameter location Parameter name Default Parameter location
Zero range ±0.25 % AMI, MFI – PDP parameters Line frequency 50 Hz AMI, MFI – PDP parameters
Following measurement ranges can be configured for The module is connected to the RTU I/O bus via the connectors
520AID01 R0002: X1 and X2.
– ± 1 V DC
– ± 10 V DC ADVICE
Figure 3: 520AID01
R0002 Front plate
Figure 4: 520AID01 R0002 Label
6 5
1
3
4
2
ERR
Resistor network
Protection
ADC
A
Micro -
controller
- I06
X3-12
...
Multiplexer
RTU I/O bus
RAM
Input circuit
+ I03
Signal- X3-5
conditioning - I03
X3-6
Flash
+ I02
X3-3
Signal-
conditioning - I02
X3-4
D
IOC
+ I01
Signal- X3-1
conditioning - I01
X3-2
68128 Mannheim, Germany poses and shall in no respect be binding. The Brochure does not claim to be ex-
haustive. Technical data in the Information are only approximate figures. We re-
www.abb.com/substationautomation serve the right at any time to make technical changes or modify the contents of
this document without prior notice. The user shall be solely responsible for the
use of any application example or information described within this document.
The described examples and solutions are examples only and do not represent
any comprehensive or complete solution. The user shall determine at its sole
discretion, or as the case may be, customize, program or add value to the ABB
products including software by creating solutions for the end customer and to
assess whether and to what extent the products are suitable and need to be ad-
justed or customized.
ABB AG reserves all rights in particular copyrights and other intellectual property
rights. Any reproduction, disclosure to third parties or utilization of its contents -
in whole or in part - is not permitted without the prior written consent of ABB AG.