Line Sizing Manager 2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

1

Case Name: Line Rating.hsc


2
PT Mucoindo Cipta Engineering
3 Unit Set: WNTS-Pemping Field1
Jakarta, Indonesia
4
Date/Time: Wed Sep 27 13:57:02 2023
5
6
7 Line Sizing Manager: Line Sizing Manager-CASE-2
8
9
10
SIZING
11 Pipe Tag/Name Line Sizing-2
12 Calculation Type Rating
13 Stream Name CASE-2 @Main
14 FlowMargin (%) 10.00 *
15 Material Carbon Steel
16 Schedule 40
17 Nominal Diameter 12 inch
18 Inner Diameter (in) 11.94
19 Wall Thickness (in) 0.4060
20 Roughness (in) 2.000e-004 *
21 Force Single Phase Off
22 Sizing Criteria Criteria-1
23 Pressure Gradient(psi/100_ft) 7.987e-002
24 Velocity Gradient (ft/s) 12.80
25 Rho V^2 (lb/ft-s2) 750.1
26 Flow Regime Vapour Only
27 Criteria Met? Met
28 Pipe Length (m) 5000 *
29 Fitting Equivalent Length (m) 0.0000
30 Use Detailed Fittings Off
31 Total Pressure Drop (psi) 13.10
32
33
SETTINGS
34 Flow Correlation: Beggs and Brill (1979)
35
36
Criteria
37 Criteria Name Pressure Gradient(psi/100_ft) Velocity (ft/s) Rho V^2 (lb/ft-s2) Description
38 Criteria-1 1.200 * 60.00 * 10000. * A new criteria
39
40
DETAILS
41 Pipe Tag/Name Line Sizing-2
42 Pressure Gradient Rating
43 Stream Name CASE-2 @Main
44 Upstream Unit Operation Name
45 Upstream Unit Operation Type
46 Downstream Unit Operation Name
47 Downstream Unit Operation Type
48 Vapor Mass Flow Rate (lb/hr) 1.490e+005
49 Vapor Molecular Weight 18.10
50 Vapor Mass Density (lb/ft3) 4.576
51 Vapor Viscosity (cP) 1.403e-002
52 Vapor Cp/Cv 1.639
53 Vapor Z Factor 0.8174
54 Liquid Mass Flow Rate (lb/hr) ---
55 Liquid Molecular Weight 18.10
56 Liquid Mass Density (lb/ft3) ---
57 Liquid Viscosity (cP) ---
58 Flow Margin (%) 10.00 *
59 Pipe Material Carbon Steel
60 Schedule 40
61 Pipe Nominal Diameter 12 inch
62 Pipe Inside Diameter (in) 11.94
63 Pipe Wall Thickness (in) 0.4060
64 Pipe Roughness (in) 2.000e-004 *
65 Force Single Phase Off
66 Sizing Criteria Criteria-1
67 Pressure Gradient (psi/100_ft) 7.987e-002
68 Criteria Pressure Gradient (psi/100_ft) 1.200
69 Aspen Technology Inc. Aspen HYSYS Version 11 Page 1 of 2
Licensed to: Company Name Not Available * Specified by user.
1
Case Name: Line Rating.hsc
2
PT Mucoindo Cipta Engineering
3 Unit Set: WNTS-Pemping Field1
Jakarta, Indonesia
4
Date/Time: Wed Sep 27 13:57:02 2023
5
6
7 Line Sizing Manager: Line Sizing Manager-CASE-2 (continued)
8
9
10
DETAILS
11 Velocity (ft/s) 12.80
12 Criteria Velocity (ft/s) 60.00
13 Rho V^2 (lb/ft-s2) 750.1
14 Criteria Rho V^2 (lb/ft-s2) 10000.
15 Flow Regime Vapour Only
16 Criteria Met or Failed? Met
17 Pipe Length (m) 5000 *
18 Fitting Equivalent Length (m) 0.0000
19 Use Detailed Fittings No
20 Total Pressure Drop (psi) 13.10
21
22
Detailed Fittings
23 Line Sizing-2 Additional Equivalent Length 0.0000 m *
24 Fitting Type VH Factor FT Factor Quantity Source
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69 Aspen Technology Inc. Aspen HYSYS Version 11 Page 2 of 2
Licensed to: Company Name Not Available * Specified by user.