IP ­ Ingress Protection Ratings


IP ­ Ingress Protection rating is used to specify the environmental protection ­ electrical enclosure ­ of electrical equipment
Sponsored Links

Ingress Protection (IP) ratings are developed by the European Committee for Electro Technical Standardization (CENELEC) (NEMA IEC 60529 Degrees of Protection Provided by Enclosures ­ IP Code), specifying the environmental
protection the enclosure provides.

The IP rating normally has two (or three) numbers:

1. Protection from solid objects or materials


2. Protection from liquids (water)
3. Protection against mechanical impacts (commonly omitted, the third number is not a part of IEC 60529)

Example ­ IP Rating
With the IP rating IP 54, 5 describes the level of protection from solid objects and 4 describes the level of protection from liquids.

An "X" can used for one of the digits if there is only one class of protection, i.e. IPX1 which addresses protection against vertically falling drops of water e.g. condensation..

IP First number ­ Protection against solid objects

0 No special protection
1 Protected against solid objects over 50 mm, e.g. accidental touch by persons hands.
2 Protected against solid objects over 12 mm, e.g. persons fingers.
3 Protected against solid objects over 2.5 mm (tools and wires).
4 Protected against solid objects over 1 mm (tools, wires, and small wires).
5 Protected against dust limited ingress (no harmful deposit).
6 Totally protected against dust.

IP Second number ­ Protection against liquids

0 No protection.
1 Protection against vertically falling drops of water e.g. condensation.
2 Protection against direct sprays of water up to 15o from the vertical.
3 Protected against direct sprays of water up to 60o from the vertical.
4 Protection against water sprayed from all directions ­ limited ingress permitted.
5 Protected against low pressure jets of water from all directions ­ limited ingress.
6 Protected against temporary flooding of water, e.g. for use on ship decks ­ limited ingress permitted.
7 Protected against the effect of immersion between 15 cm and 1 m.
8 Protects against long periods of immersion under pressure.

IP Third number ­ Protection against mechanical impacts (commonly omitted, the third number is not a part of IEC 60529)

0 No protection.
Protects against impact of 0.225 joule
1
(e.g. 150 g weight falling from 15 cm height).
Protected against impact of 0.375 joule
2
(e.g. 250 g weight falling from 15 cm height).
Protected against impact of 0.5 joule
3
(e.g. 250 g weight falling from 20 cm height).
Protected against impact of 2.0 joule
4
(e.g. 500 g weight falling from 40 cm height).
Protected against impact of 6.0 joule
5
(e.g. 1.5 kg weight falling from 40 cm height).
Protected against impact of 20.0 joule
6
(e.g. 5 kg weight falling from 40 cm height).

In order to comply with the stringent requirements for CE Marking machine makers today fits their machines with parts certified according EU (European Union) and international standards.

Example ­ IP 22
An electrical socket rated IP22 is protected against

solid objects over 12 mm ­ ex. insertion of fingers


direct sprays of water up to 15o from the vertical ­ ex. damage or unsafety due to vertically or nearly vertically dripping water
Sponsored Links

Related Topics
Electrical ­ Amps and electrical wiring, AWG ­ wire gauge, electrical formulas, motors and units
Documentation ­ Documentation of process control systems ­ Block Flow Diagrams (BFD), Process Flow Diagrams (PFD), Piping and Instrumentation Diagrams (P&ID) and more
Process Control ­ Instrumentation and process control systems ­ engineering and documentation
Temperature Measurement ­ Measurement of temperature ­ probes, sensors and transmitters
Risk, Reliability and Safety ­ Risk, Reliability and Safety in Process Control Systems

Related Documents
NEMA Enclosure Standards of Electrical Motors ­ The NEMA enclosure standards of electrical motors
CE Marking ­ The European Machine Directive
Converting from NEMA to IEC Enclosure Classifications ­ Converting from NEMA enclosure classifications to IEC enclosure classifications

Tag Search
en: ip ratings protection

http://www.engineeringtoolbox.com/ip­ingress­protection­d_452.html 1/4

You might also like