Professional Documents
Culture Documents
Nihon Spindle KX SERIES
Nihon Spindle KX SERIES
KX Series
KX Series
Heavy Duty • Higher Capacity • Space Saving
01
NIHON SPINDLE COOLING TOWERS
KX Series
Heavy Duty
The KX Series towers are specially designed for high performance
and large capacity projects. The internal structures have been sized
up significantly in order to ensure better solidity and rigidity.
Higher Capacity
The KX Series can deliver up to 750TR per cell which is 3 times more
than our standard models. Such high capacity towers are suitable
for very demanding projects such as district cooling, power stations,
industrial plants etc.
Space Saving
The footprint per TR is very much smaller compared to standard
models. These towers are purpose-built to achieve high thermal
performance while maintaining minimum footprint.
02 03
NIHON SPINDLE COOLING TOWERS
KX Series
Our Successful History Uncompromising Quality Material Hot Water Distribution System
Performance Our crossflow design uses hot water basin as the distribution system which
eliminate the use of nozzle spray heads. This will lower the first cost in the
pumping system and operating cost in the long run due to lower energy
consumption.
In order to maintain the highest standards of quality, our products undergo strict Manufacturing Control, Engineering
annual testing according to world-renowned CTI standards. A test facility was Design, Quality Control and R&D led
designed and built at our manufacturing plant in Penang, Malaysia, in accordance by qualified Japanese team from
to the specifications by a qualified and certified CTI tester. This unique CTI test Nihon Spindle Manufacturing Co.,
facility has a combined floor space of 15,000 sq ft and is capable of up to 1,000 Ltd., Osaka Japan.
tonnes heat rejection testing. Testing is accomplished to great accuracy by 4
massive diesel-boilers and numerous sensors embedded around the vicinity of
the test platform. In addition, our plant also includes a Static Fan Balancing and
Dynamic Fan Testing facility.
CTI certification offers assurances in performance and reliability to the end user.
Performance capacity is the contributing factor to a successful certification.
04 05
NIHON SPINDLE COOLING TOWERS
KX Series
CTA-KX3-N Energy Saving Low Noise Design
Specifications
Specifications Performance Performance
& Design & Design Overall Dimensions
Overall Dimensions Fan Assembly Fan Assembly Common PipingCommon
Details Piping Details Weight Weight
Cold Water
ColdOverflow(mmxq'ty)
In In
100 100 100.4
100 98.6
100 97.5
100.4 98.6
97 97.5
97 95
97 97 95 Fan Fan Motor Motor
Internal
Internal
Evaporation Loss %
Evaporation Loss %
Hot Water
Basin Capacity (Litres)
Basin
Overall
Operating
Operating Weight(kg)
Temperature
Temperature
Overflow(mmxq'ty)
Fan
Water Outlet(mmxq'ty)
Manual Make-Up
Manual Make-Up
Drift Loss %
Drift Loss %
Width(W) (mm)
Width(W)
Length(L)
Length(L)
Drain(mmxq'ty)
Drain(mmxq'ty)
No. Of Cells
No. Of Cells
Dry
Dry Weight(kg)
Auto Make-Up
Auto
Inlet(mmxq'ty)
Inlet(mmxq'ty)
Inlet(mmxq'ty)
Inlet(mmxq'ty)
Mounting Location
Mounting Location
HeadMake-Up
Head Loss(m)
Rated Output (kw)
Rated
Fan Speed (rpm)
Height(h)
Diameter (mm)
Diameter (mm)
Of Cooling Tower
Of Cooling
Power
Power Supply
Drive System
Drive System
Height(H)
Weight(kg)
Outlet(mmxq'ty)
Inlet(mmxq'ty)
In In
Loss(m)
37.8 37.8 37.8
38 37.8
37 36.4
38 36.137 36.1
36.4 36.1
35 36.1 35
Output (kw)
Weight(kg)
Type
Type
Type
Type
(mm)(mm)
Supply
(mm)
Out ° C Out
32.2 ° C 32.2
32.2 33 32.2
32 30.8
33 30.632 30.6
30.8 29.5
30.6 30.6 29.5
(Litres)
(mm)
Tower
WB WB28.3 27.8 28.3
28 27.8
27 27.2
28 27.827 27.2
27.2 27.2
27.8 27.2 27.2
cell)
3 3
MODEL MODEL Circulating
HRT HRT Circulating
Water Flowrate
Water
(mFlowrate
/hr) (m /hr)
300 190.5 203.9
CTA-300KX3-N CTA-300KX3-N 300 246.0
190.5 234.0
203.9 169.2
246.0 146.8
234.0 163.8
169.2 124.9
146.8 163.8 124.9 3730 2400 5395
3730 4266
2400 704
5395 4266 2000704 4782000 1749 478 1749 5.5 X 1 190x2 250x1
5.5 X 1 80x1
190x2 80x1
250x1 40x1
80x1 40x1
80x1 40x1
0 2400
40x1 5050
0 2400 5050
CTA-350KX3-N CTA-350KX3-N
350 222.3 237.9
350 287.0
222.3 273.0
237.9 197.4
287.0 171.3
273.0 191.0
197.4 145.7
171.3 191.0 145.7 4285 2800 5395
4285 4512
2800 950
5395 4512 2200950 3952200 2040 395 2040 7.5 X 1 240x2 250x1
7.5 X 1 80x1
240x2 80x1
250x1 40x1
80x1 40x1
80x1 40x1
0 2640
40x1 5670
0 2640 5670
380V 50Hz
Outside Air-Stream
Outside Air-Stream
900 571.5 611.8
CTA-900KX3-N CTA-900KX3-N 900 737.9
571.5 702.0
611.8 507.5
737.9 440.5
702.0 491.3
507.5 374.6
440.5 491.3 374.6 10190 6295 10190
5770 4557
6295 995
5770 4557 2500995 3252500 5246 325 5246 11 X 2 240x4 250x2
11 X 2 80x2
240x4 80x2
250x2 40x2
80x2 40x2
80x2 40x2
0 5890
40x2 12880
0 5890 12880
Axial Flow
Axial Flow
And Pulley
1000 635.0 679.8
CTA-1000KX3-NCTA-1000KX3-N 1000 819.9
635.0 780.0
679.8 563.9
819.9 489.4
780.0 545.9
563.9 416.2
489.4 545.9 416.22 11535 70952 5770
11535 4557
7095 995
5770 4557 2500995 3312500 5830 331 5830 11 X 2 240x4 300x2
11 X 2 80x2
240x4 80x2
300x2 40x2
80x2 40x2
80x2 40x2
0 6550
40x2 14490
0 6550 14490
4 4
or 3Phase
1200 762.0 815.7
CTA-1200KX3-NCTA-1200KX3-N 1200 983.9
762.0 936.0
815.7 676.7
983.9 587.3
936.0 655.0
676.7 499.5
587.3 655.0 499.5 14100 7895 14100
6145 4732
7895 1170
6145 4732 28001170 3142800 6996 314 6996 15 X 2 240x4 300x2
15 X 2 80x2
240x4 80x2
300x2 50x2
80x2 50x2
80x2 50x2
0 7880
50x2 17310
0 7880 17310
Drive460V 60Hz
1350 857.3 917.7
CTA-1350KX3-NCTA-1350KX3-N 1350 1106.9
857.3 1053.0
917.7 761.2
1106.9 660.8
1053.0 736.9
761.2 561.9
660.8 736.9 561.9 15200 9390 15200
5770 4557
9390 995
5770 4557 2500995 3252500 7869 325 7869 11 X 3 240x6 300x3
11 X 3 80x3
240x6 80x3
300x3 40x3
80x3 40x3
80x3 40x3
0 8660
40x3 19140
0 8660 19140
CTA-2400KX3-NCTA-2400KX3-N
2400 1524.0 1631.4
2400 1967.8
1524.0 1872.0
1631.41353.3
1967.81174.7
1872.01310.1 1174.7 1310.1 999.04
1353.3 999.0 28035 4
15685 28035
6145 15685
4732 1170
6145 4732 28001170 3142800 13992 314 13992 15 X 4 240x8 300x4
15 X 4 80x4
240x8 80x4
300x4 50x4
80x4 50x4
80x4 50x4
0 15090
50x4 33930
0 15090 33930
CTA-2600KX3-NCTA-2600KX3-N
2600 1651.0 1767.4
2600 2131.7
1651.0 2028.0
1767.41466.1
2131.71272.6
2028.01419.2
1466.1 1082.2
1272.6 1419.2 1082.2 30580 17285 30580
6145 17285
4732 1170
6145 4732 28001170 3672800 15156 367 15156 15 X 4 240x8 300x4
15 X 4 80x4
240x8 80x4
300x4 50x4
80x4 50x4
80x4 50x4
0 16090
50x4 36400
0 16090 36400
HRT, nominal heat rejection ton is based on flowrate of 13L/min (0.78m³/hr) at 37°C inlet temperature,
32°C outlet temperature & 27°C wet bulb temperature condition.
Robust bottom structure support using I-beams. KX3-N & KX3E-N design offer great savings in space by limiting Intermediate HDG Steel infill supports in KX series. Gear reducer as an optional item to belt drive system.
the footprint of the tower.
06 07
NIHON SPINDLE COOLING TOWERS
KX Series
CTA-KX3E-N Space Saving Low Noise Design
Specifications
Specifications PerformancePerformance
& Design & Design Overall Dimensions
Overall Dimensions Fan Assembly Fan Assembly Common PipingCommon
Details Piping Details Weight Weight
Cold Water
Internal
Evaporation Loss %
Evaporation Loss %
Basin Capacity (Litres)
Basin
Operating
Operating Weight(kg)
Temperature
Temperature
Overflow(mmxq'ty)
Overflow(mmxq'ty)
Manual Make-Up
Manual Make-Up
No. Of Cells
No. Of Cells
Drift Loss %
Drift Loss %
Auto
Auto Make-Up
Width(W) (mm)
Length(L)
Width(W)
Length(L) (mm)
Dry Weight(kg)
Dry Weight(kg)
Inlet(mmxq'ty)
Inlet(mmxq'ty)
Drain(mmxq'ty)
Drain(mmxq'ty)
Inlet(mmxq'ty)
Inlet(mmxq'ty)
Mounting Location
Mounting Location
Fan Speed (rpm)
Rated
Head Loss(m)
Head Loss(m)
Capacity(mm)
WB WB
Diameter (mm)
Diameter (mm)
83 82 82.4
83 80.6
82 82.4
81 80.6
82 81
81 81
82 81 81
Power
Power Supply
Drive System
Drive System
Of Cooling
Height(H)
Make-Up
Outlet(mmxq'ty)
Type
Type
In In
37.8 37.8 38
37.8 37
37.8 36.4
38 36.137 36.1
36.4 36.1
35 36.1 35
Output (kw)
Weight(kg)
Type
Type
Supply
(mm)(mm)
Out ° C Out
32.2 ° C 33
32.2 32.2 32
32.2 30.8
33 30.632 30.6
30.8 29.5
30.6 30.6 29.5
(Litres)
WB WB
Tower
28.3 27.8 28
28.3 27
27.8 27.2
28 27.827 27.2
27.2 27.2
27.8 27.2 27.2
cell)
3
MODEL MODEL Circulating
HRT HRT Water
Circulating
Flowrate
Water(m Flowrate
/hr) (m 3/hr)
350 222.3 237.9
CTA-350KX3E-N CTA-350KX3E-N 350 287.0
222.3 273.0
237.9 197.4
287.0 171.3
273.0 191.0
197.4 145.7
171.3 191.0 145.7 3730 2400 5395
3730 4266
2400 704
5395 4266 2000704 4432000 2040 443 2040 11 X 1 190x2 250x1
11 X 1 80x1
190x2 80x1
250x1 40x1
80x1 40x1
80x1 040x1 247040x1 51200 2470 5120
Outside Air-Stream
Outside Air-Stream
V-Belt And Pulley Drive
V-Belt
1100 698.5 747.7
CTA-1100KX3E-NCTA-1100KX3E-N 1100 901.9
698.5 858.0
747.7 620.3
901.9 538.4
858.0 600.4
620.3 457.9
538.4 600.4 457.9 10190 6295 5770
10190 4557
6295 995
5770 4557 2500995 3242500 6412 324 6412 15 X 2 240x4 250x2
15 X 2 80x2
240x4 80x2
250x2 40x2
80x2 40x2
80x2 040x2 597040x2 129600 5970 12960
50Hz
Axial Flow
Axial Flow
Andor
1200 762.0 815.7
CTA-1200KX3E-NCTA-1200KX3E-N 1200 983.9
762.0 936.0
815.7 676.7
983.9 587.3
936.0 655.0
676.7 499.5
587.3 2
655.0 499.5 11535 70952 5770
11535 4557
7095 995
5770 4557 2500995 3732500 6996 373 6996 18.5 X 2 240x4 300x2
18.5 X 2 80x2
240x4 80x2
300x2 40x2
80x2 40x2
80x2 040x2 663040x2 145700 6630 14570
4 4
1400 889.0 951.7
CTA-1400KX3E-NCTA-1400KX3E-N 1400 1147.9
889.0 1092.0
951.7 789.4
1147.9 685.2
1092.0 764.2
789.4 582.7
685.2 764.2 582.7
Pulley
14100 7895 6145
14100 4732
7895 1170
6145 4732 28001170 3332800 8160 333 8160 22 X 2 240x4 300x2
22 X 2 80x2
240x4 80x2
300x2 50x2
80x2 50x2
80x2 050x2 798050x2 174100 7980 17410
3Phase
1500 952.5 1019.6
CTA-1500KX3E-NCTA-1500KX3E-N 1500 1229.9
952.5 1170.0
1019.6 845.8
1229.9 734.2
1170.0 818.8
845.8 624.4
734.2 818.8 624.4 15375 8695 6145
15375 4732
8695 1170
6145 4732 28001170 3512800 8744 351 8744 22 X 2 240x4 300x2
22 X 2 80x2
240x4 80x2
300x2 50x2
80x2 50x2
80x2 050x2 847050x2 187200 8470 18720
Drive
1650 1047.8 1121.6
CTA-1650KX3E-NCTA-1650KX3E-N 1650 1352.8
1047.81287.0
1121.6 930.4
1352.8 807.6
1287.0 900.7
930.4 686.8
807.6 900.7 686.8 15200 9390 5770
15200 4557
9390 995
5770 4557 2500995 3242500 9618 324 9618 15 X 3 240x6 300x3
15 X 3 80x3
240x6 80x3
300x3 40x3
80x3 40x3
80x3 040x3 878040x3 192600 8780 19260
460V 60Hz
1800 1143.0 1223.6
CTA-1800KX3E-NCTA-1800KX3E-N 1800 1475.8
1143.01404.0
1223.61015.0
1475.8 881.0
1404.0 982.5
1015.0 749.2
881.0 982.5 749.2 17225 10590 5770
17225 4557
10590 995
5770 4557 2500995 3732500 10494 373 10494 18.5 X 3 240x6 300x3
18.5 X 3 80x3
240x6 80x3
300x3 40x3
80x3 40x3
80x3 040x3 975040x3 216600 9750 21660
㻖 㻖
2100 1333.5 1427.5
CTA-2100KX3E-NCTA-2100KX3E-N 2100 1721.8
1333.51638.0
1427.51184.1
1721.81027.8
1638.0 1146.3
1184.1 874.1
1027.8 1146.3 874.1 21070 11790 6145
21070 4732
11790 1170
6145 4732 28001170 3332800 12240 333 12240 22 X 3 240x6 300x3
22 X 3 80x3
240x6 80x3
300x3 50x3
80x3 50x3
80x3 050x3 11670
50x3 258200 11670 25820
HRT, nominal heat rejection ton is based on flowrate of 13L/min (0.78m³/hr) at 37°C inlet temperature,
32°C outlet temperature & 27°C wet bulb temperature condition.
Trained staff conducting stringent quality control Production floor space: 60,000 sq. ft. Automated Vacumn Forming Machine to produce high efficiency infills. Highly skilled assembly workers.
on every product.
08 09
NIHON SPINDLE COOLING TOWERS
KX Series
KX3-N Sound Data KX3-N Sound Data
Measuring 1 2 3 4 5 Measuring 1 2 3 4 5
MODEL MODEL
Direction 2m 5m 10m 20m 45° Upper 1.5m Direction 2m 5m 10m 20m 45° Upper 1.5m
W 69.5 65.5 60 52.5 W 76.5 71.5 67 59.5
CTA-300KX3-N 74 CTA-1200KX3-N 81
L 66.5 62.5 57 49.5 L 73.5 69.5 64 56.5
W 70.5 66.5 61 53.5 W 77 72 67.5 60
CTA-350KX3-N 75 CTA-1300KX3-N 81
L 67.5 63.5 58 50.5 L 74 70 64.5 57
W 72 68 62.5 55 W 77 72 67 60
CTA-450KX3-N 76.5 CTA-1350KX3-N 80.5
L 69 65 59.5 52 L 74 70 64.5 57
W 72 68 62.5 55 W 77 72 67 60
CTA-500KX3-N 76.5 CTA-1500KX3-N 80.5
L 69 65 59.5 52 L 74 70 64.5 57
W 73.5 69.5 64 56.5 W 78.5 73.5 68.5 61.5
CTA-600KX3-N 78 CTA-1800KX3-N 82
L 70.5 66.5 61 53.5 L 75.5 71.5 66 58.5
W 74 70 64.5 57 W 79 74 69 62
CTA-650KX3-N 78.5 CTA-1950KX3-N 82.5
L 71 67 61.5 54 L 76 72 66.5 59
W 73.5 68.5 64 56.5 W 78 73 68 61
CTA-700KX3-N 78 CTA-2000KX3-N 80.5
L 70.5 66.5 61 53.5 L 75 71 65.5 58
W 75 70 65.5 58 W 79.5 74.5 69.5 62.5
CTA-900KX3-N 79.5 CTA-2400KX3-N 82
L 72 68 62.5 55 L 76.5 72.5 67 59.5
W 75 70 65.5 58 W 80 75 70 63
CTA-1000KX3-N 79.5 CTA-2600KX3-N 82.5
L 72 68 62.5 55 L 77 73 67.5 60
* All units are measured in dB. ±3dB tolerance is applicable in comparison with standard levels. * All units are measured in dB. ±3dB tolerance is applicable in comparison with standard levels.
1. The noise levels are measured in conformity with JIS B8609 (Performance test for forced draft cooling towers) 1. The noise levels are measured in conformity with JIS B8609 (Performance test for forced draft cooling towers)
2. Noise levels are based on normal operating conditions, other factors are excluded. 2. Noise levels are based on normal operating conditions, other factors are excluded.
3. Noise levels are measured based on A scale. 3. Noise levels are measured based on A scale.
010 011
NIHON SPINDLE COOLING TOWERS
KX Series
KX3E-N Sound Data KX3E-N Sound Data
Measuring 1 2 3 4 5 Measuring 1 2 3 4 5
MODEL MODEL
Direction 2m 5m 10m 20m 45° Upper 1.5m Direction 2m 5m 10m 20m 45° Upper 1.5m
W 70.5 66.5 61 53.5 W 79.5 74.5 70 62.5
CTA-350KX3E-N 75 CTA-1400KX3E-N 84
L 67.5 63.5 58 50.5 L 76.5 72.5 67 59.5
W 73.5 69.5 64 57.5 W 79 74 69.5 62
CTA-450KX3E-N 78 CTA-1500KX3E-N 83
L 70.5 66.5 61 53.5 L 76 72 66.5 59
W 75 71 65.5 58 W 80 75 70 63
CTA-550KX3E-N 79.5 CTA-1650KX3E-N 83.5
L 72 68 62.5 55 L 77 73 67.5 60
W 77 73 67.5 60 W 82 77 72 65
CTA-600KX3E-N 81.5 CTA-1800KX3E-N 85.5
L 74 70 64.5 57 L 79 75 69.5 62
W 76.5 72.5 67 59.5 W 81.5 76.5 71.5 64.5
CTA-700KX3E-N 81 CTA-2100KX3E-N 85
L 73.5 69.5 64 56.5 L 78.5 74.5 69 61.5
W 76 72 66.5 59 W 81 76 71 64
CTA-750KX3E-N 80.5 CTA-2250KX3E-N 84.5
L 73 69 63.5 56 L 78 74 68.5 61
W 76.5 71.5 67 59.5 W 83 78 73 66
CTA-900KX3E-N 81 CTA-2400KX3E-N 85.5
L 73.5 69.5 64 56.5 L 80 76 70.5 63
W 78 73 68.5 61 W 82.5 77.5 72.5 65.5
CTA-1100KX3E-N 82.5 CTA-2800KX3E-N 85
L 75 71 65.5 58 L 79.5 75.5 70 62.5
W 80 75 70.5 63 W 82 77 72 65
CTA-1200KX3E-N 84.5 CTA-3000KX3E-N 84.5
L 77 73 67.5 60 L 79 75 69.5 62
* All units are measured in dB. ±3dB tolerance is applicable in comparison with standard levels. * All units are measured in dB. ±3dB tolerance is applicable in comparison with standard levels.
1. The noise levels are measured in conformity with JIS B8609 (Performance test for forced draft cooling towers) 1. The noise levels are measured in conformity with JIS B8609 (Performance test for forced draft cooling towers)
2. Noise levels are based on normal operating conditions, other factors are excluded. 2. Noise levels are based on normal operating conditions, other factors are excluded.
3. Noise levels are measured based on A scale. 3. Noise levels are measured based on A scale.
012 013
NIHON SPINDLE COOLING TOWERS
KX Series
Materials of Construction Options (KX3-N, KX3E-N) Optional Accessories
Area Part
Standard Wetted Parts SS All SS Vibration Isolators Aluminium Alloy Blade Gear Reducer
Construction Construction Construction
Bottom Basin Frame HDG Steel HDG Steel Stainless Steel
Upper Structural Frame HDG Steel Stainless Steel Stainless Steel
Ladder HDG Steel HDG Steel Stainless Steel
Tower Structure
Bolt & Nut Stainless Steel Stainless Steel Stainless Steel
Infill Support HDG Steel Stainless Steel Stainless Steel
Fan Guard HDG Steel Stainless Steel Stainless Steel
Mounted at the feet of the cooling tower, Aluminium alloy blades are available as an As an alternative to wedge belt drive
Outlet Sump HDG Steel Stainless Steel Stainless Steel
vibration isolators provide an effective way optional item to our standard FRP blades. system, gear reducer option is available.
Basin Cold Water Basin FRP of isolating any vibration from the tower to These blades are recommended for use in The motor is located outside the air steam.
Hot Water Basin HDG Steel Stainless Steel Stainless Steel the concrete floors. highly corrosive enviroments.
Casing FRP Single-spring and double-spring design
Access Door FRP are generally sufficient to meet the
Perimeter requirements of the range of Nihon
Internal Partition w/door FRP
Structure Spindle cooling towers. Selection of the
Louver PVC right sizes depending on rated load and
Fan Stack FRP rated deflection.
Fan FRP
Vibration Switch Handrail & Caged Ladder Epoxy Fusion Coating
Fan Belt Wedge Belt
Fan Assembly Motor Aluminum/Cast Iron
Pulley Cover FRP
Fan Holder HDG Steel Stainless Steel Stainless Steel
Legend
1 Belt Protection Cover Vibration switch is mounted on the cooling Handrail and caged ladder can be supplied Wherever extra corrosion protection is
2 Fan Guard tower fan deck where if there is any as an optional item for added safety when needed over the standard hot dipped
3 Fan Belt excessive vibration, it will cut off power the fan deck is relatively high above galvanized steel parts, epoxy fusion coating
4 Motor supply to fan motor. ground. is available as option.
5 Fan Blade
6 Fan Stack Extended Discharge Additional Drift Hot Water Basin Cover
7 Hot Water Inlet Hole
Hood (Angle/ Straight) Eliminators
8 Hot Water Distribution Basin
9 Over Flow Pipe
10 Casing
11 Fill
12 Louvers
16 Basin Frame Wherever the discharge of air is necessary Additional drift eliminators can be supplied The hot water basin cover is available as an
17 Basin Internal Walkway to be diverted towards a certain direction, when very low drift loss is to be achieved. added protection to the hot water basin
18 Ladder FRP extended discharge hood can be easily Additional drift eliminators can further from gathering dirt, foreign particles and
19 Outlet Sump installed onto the standard fan cylinder. reduce drift loss to as low as 0.002% of the objects that can clog the basin.
20 Strainer circulating water flowrate.
014 015
NIHON SPINDLE COOLING TOWERS
KX Series
Water Treatment & Filtration Water Treatment & Filtration
other impurities build up in recirculating Chlorides as NaCI 750 ppm max 1500 ppm max
water may be defined as the cycles of Sulphates 500 ppm max 750 ppm max
concentration which is the ratio of dissolved
Drift Loss
Silica as SiO2 150 ppm 150 ppm
There is the undesired loss which can be controlled through drift eliminators but not totally
Water Treatment eliminated. Drift loss occurs due to the carry-over of tiny water droplets together with the
air discharge.
In addition to blowdown which serves as a mean to control scale build-up and corrosion,
some extensive form of water treatment is necessary in order to maintain the quality of Amount of drift loss:
water within the guidelines and for the control of biological contamination. The growth C% = Approx.0.02% of the amount circulation water
of microorganisms must be checked in order to prevent the presence of any potential
harmful bacteria including the possible outbreak of the Legionnaire disease.
Blow-down Loss
The water treatment system should minimally consist of a chemical dosage system and a
conductivity control system. In its automatic mode during operation, chemicals are dosed To maintain the limits on cycles of concentration in order to meet the water quality
at a predetermined amount and duration. The conductivity control also has a pre-set guidelines, it is necessary to bleed or blowdown a certain portion of the recirculated water.
range, where about its limit, blowdown will automatically take place and stop when its The amount of blowdown can be calculated as follows:
Total Loss
The amount of make-up water is the total sum of the three type of losses stated above.
Fully automatic chemical dosing system with conductivity Overview of installation at site.
controller and pumps.
016 017
NIHON SPINDLE COOLING TOWERS
KX Series
Engineering Specification
Cooling Tower Mechanical Equipment (Fan Section)
Each cooling tower is manufactured to cool litres per second of water from _____°C (HW) Fans shall be axial flow type with FRP blades or aluminium alloy. The fans shall be designed
entering water temperature to _____°C (CW) leaving water temperature at _____°C (WB) to provide necessary air flow for heat transfer. Fan blades shall be assembled, balanced and
entering wet bulb temperature. pitched. The fan shall operate within a FRP fan cylinder, which provides a streamlined
air entry and minimum tip clearance for maximum fan efficiency.
The cooling towers are guaranteed to perform in accordance with the conditions specified
without any modifications. Motor
The fan motor(s) shall be to IP55 standard with Class F insulation, specifically designed for
Structure cooling tower service. The motor shall be located adjacent to the fan cylinder for ease of
maintenance and increased motor life expectancy. The motor shall be fully outside of the
The cooling tower structure shall be constructed from HDG Steel. All HDG (Hot Dipped
moist discharge air stream.
Galvanized) are carried out in accordance to ISO 1461:1999. The cooling tower casing shall
be constructed from FRP (Fibreglass Reinforced Polyester).
Mechanical Support
Basin The mechanical support shall be of HDG Steel and bolted to the top of fan cylinder. HDG
Steel fan guard shall be bolted to the top of mechanical support for safety measure.
The basin sump shall be constructed from HDG Steel. The basin shall be made of FRP and Extended lubrication lines shall be provided to the bearings with grease nipples located
equipped with drain outlet for ease of cleaning. outside for ease of schedule maintenance.
Infill
Access
Infill shall be of ultra-violet ray treated PVC (Polyvinyl Chloride). The PVC infill shall be
vacuum-formed with patented intricate design to facilitate a good spread of water over the A FRP inspection door shall be provided to facilitate entry into the cooling tower for
surface area of crossflow induced draft of air. It also incorporate a built in drift eliminator. inspection and maintenance. A HDG Steel access ladder shall be installed on the cooling
tower.
Specification & Data are correct at the time of publication; validation should be made at the time of purchase.
The MANUFACTURER reserves the right to change without prior notice.
SAFETY PRECAUTION SHOULD BE ABIDE AT ALL TIME TO PREVENT ACCIDENT.
Operation, Maintenance and Repair of this equipment should only be carried out by qualified personal.
WARRANTIES: Please refer to the Limitation of Warranties applicable to and in effect at the time of purchase.
018 019
NIHON SPINDLE COOLING TOWERS
KX Series
Our Past Project Portfolio References from Nihon Spindle Japan and China
Vista Tower, Intermark Mall and Doubletree Hotel by Sentosa Integrated Resort, Singapore District Cooling Plant, Japan District Cooling Plant in China
Hilton, Kuala Lumpur, Malaysia
University Malaysia Sarawak, Malaysia Dubai Water Front 700KX tower, Japan 350KX tower, Japan
020 021
NIHON SPINDLE COOLING TOWERS
KX Series
COOLING TECHNOLOGY INSTITUTE COOLING TECHNOLOGY INSTITUTE
P. O. Box 73383, Houston, Texas 77273 • 2611 FM 1960 West, Suite A-101, Houston, Texas 77068 P. O. Box 73383, Houston, Texas 77273 • 2611 FM 1960 West, Suite A-101, Houston, Texas 77068
Phone: 281.583.4087 • Fax: 281.537.1721 • email: vmanser@ cti.org • http://www.cti.org Phone: 281.583.4087 • Fax: 281.537.1721 • email: vmanser@ cti.org • http://www.cti.org
Subject: CTI Cooling Tower Certification for the CTA-250KX3 CTA-250KX30 CTA-250KX3L CTA-250KX30L CTA-350KX3-N CTA-350KX30-N
Nihon Spindle Manufacturing Company, Ltd. CTA-290KX3M CTA-290KX30M
CTA-KX Series of Cooling Towers CTA-310KX3E CTA-310KX30E CTA-310KX3S CTA-310KX30S CTA-450KX3E-N CTA-450KX30E-N
The Nihon Spindle Manufacturing Company, Ltd., line of CTA-KX Series cooling towers has been
CTA-450KX3 CTA-450KX30 CTA-450KX3L CTA-450KX30L CTA-650KX3-N CTA-650KX30-N
assigned and should use CTI Certification Validation Number 08-33-01. You are hereby authorized CTA-500KX3E CTA-500KX30E CTA-500KX3M CTA-500KX30M CTA-750KX3E-N CTA-750KX30E-N
and encouraged to display the CTI Certification Logo in all pertinent literature and are required to
affix the CTI Certification Label on all towers comprising the line, as provided in the Certification
Footnotes:
Standard.
1. Standard Model Series are 1.00 m3/h/RT @ 37°C-32°C-28°C for distribution in Japanese market.
Entire Model Series are 1.00 m3/h/RT @ 37°C-32°C-28°C for distribution in markets except Japan.
Very truly yours,
N Model Series are 0.78 m3/h/RT @ 37°C-32°C-27°C for distribution in markets except Japan.
2. CTA-KX3 Models include an integral cold water basin.
CTA-KX30 Models do not include an integral cold water basin.
3. Multiple cell models of the single cell models above are also available but not listed.
Thomas E. Weast, P.E.
CTI Certification Administrator
A Cooling Tower Institute, Inc. Company A Cooling Tower Institute, Inc. Company
Page 1 of 2 Page 2 of 2
022 023
www.spindle.com.my
024