Professional Documents
Culture Documents
TeSys Island - TPRST038
TeSys Island - TPRST038
Spesifikasi
Disklaimer: Dokumentasi ini tidak ditujukan sebagai pengganti dan tidak untuk digunakan untuk menentukan kesesuaian atau keandalan produk ini untuk aplikasi pengguna
Main
Range TeSys
Device presentation Direct starter connected to an automation controller through a bus coupler
Operational only when connected to a bus coupler
[Ue] rated operational voltage <= 480 V AC 47...63 Hz for overvoltage cat. III
<= 690 V AC 47...63 Hz for overvoltage cat. II
[Ie] rated operational current 38 A (at <50 °C) at <= 440 V AC-3
40 A (at <50 °C) at <= 440 V AC-1
07 Jul 22 1
Thermal protection adjustment 0.76…38 A
range
Complementary
Mechanical durability 30 Mcycles
Safety performance level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Connections - terminals Screw-clamp terminals 1 cable(s) 1.5…10 mm² (AWG 16...AWG 8) rigid
Screw-clamp terminals 2 cable(s) 1.5…10 mm² (AWG 16...AWG 8) rigid
2
07 Jul 22
Screw-clamp terminals 1 cable(s) 2.5…10 mm² (AWG 14...AWG 8) flexible without cable end
Screw-clamp terminals 2 cable(s) 2.5…10 mm² (AWG 14...AWG 8) flexible without cable end
Screw-clamp terminals 1 cable(s) 1.5…10 mm² (AWG 16...AWG 10) flexible with cable end
Screw-clamp terminals 2 cable(s) 1.5…6 mm² (AWG 16...AWG 10) flexible with cable end
Width 45 mm
Height 121 mm
Depth 115 mm
Environment
Ambient air temperature for -25…70 °C
storage
Pollution degree 2
Protective treatment TC
Vibration resistance 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibility Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4
Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5
Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5
Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
Packing Units
Unit Type of Package 1 PCE
Package 1 Height 5 cm
Package 1 Length 13 cm
Package 2 Height 15 cm
Package 2 width 30 cm
Package 2 Length 40 cm
Offer Sustainability
Sustainable offer status Green Premium product
07 Jul 22 3
EU RoHS Declaration
WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins
Contractual warranty
Warranty 18 months
4