Paper Title : Wireless Saline Monitoring

System

Tushar A. Madewar Bhimrao B. Shende Ajinkya Andrashkar


Electronics Department Of YCCE Electronics Department Of YCCE Electronics Department Of YCCE
Yeshwantrao Chavan College Yeshwantrao Chavan College Yeshwantrao Chavan College
(Affiliation With RTMNU) (Affiliation With RTMNU) (Affiliation With RTMNU)
Wanadongri,Nagpur,INDIA Wanadongri,Nagpur,INDIA Wanadongri,Nagpur,INDIA
madewartushar@gmail.com bhimshende810@gmail.com ajinkyaandraskar@gmail.com

Shrushti Gajbhiye Minakshi Harinkhede


Electronics Department Of YCCE Electronics Department Of YCCE
Yeshwantrao Chavan College Yeshwantrao Chavan College
(Affiliation With RTMNU) (Affiliation With RTMNU)
Wanadongri,Nagpur,INDIA Wanadongri,Nagpur,INDIA
chiumummmy@gmai.com harinkhede.minakshi@gmail.com

Abstract— Saline, one of the most popular intravenous (IV) which will be programmed in order to send alarm buzzer to
therapy plays a major role in the management of patients who nurses and doctors to indicate the critical level of saline
are critically ill. Surveillance of saline bottle level is very
important because when the bottle is emptied and the needle is II. RELATED WORK
not removed from the vein then the blood flows outward into
the bottle. In hospitals, the nurses or caretakers are responsible A. Wireless health and saline monitoring
for monitoring the saline bottle level. Mostly, due to negligence Present invention in general relates to design and develop
and any unusual condition, the exact timing of removing the a method and wireless device for health and saline
needle from the patient’s vein is ignored which causes a serious monitoring system and in particular to standalone wireless
casualty and may lead to death as well. Furthermore, remote sensor node to monitors saline levels and alerts
monitoring is a need to provide telehealth services. To prevent doctors/nurses in hospital. These notifications about saline
the accident due to the ignorance of caretakers and to provide level are sending to mobile through GSM messaging
remote surveillance in telehealth services, we have proposed the technique as well as using Bluetooth Technology on Android
cost-effective smart saline level monitoring device which phone. Notifications are also sent using Xbee RF technology.
includes the combination of sensor and ATMega Controller. We Notifications or warnings are sent to the user when saline
have built this system by using load sensor and RF Module. The level goes below the threshold and needs to be refilled. The
load sensor converts the weight of the bottle to a specific
invention also presents mathematical model based method by
voltage. The ATMega microcontroller generates and publishes a
specific message based on the voltage received from the sensor.
which we can predict the time of saline bottle is expected to
To publish and present the messages to the devices of
get empty thus allowing doctors and nurses to manage their
subscribers like doctors, nurses or caretakers, we have used time. Device also notifies user when saline flow stops due to
RF Module and LCD. This proposed monitoring system fulfills various reasons like blockage in saline tube.
the reliable delivery of messages to the subscribers which is B. Smart Saline Monitoring System using ESP32 AND
very important for healthcare.
MQTT-S
I. INTRODUCTION Saline, one of the most popular intravenous (IV) therapy
The medical field is progressing and advancing rapidly plays a major role in the management of patients who are
due to the advancement in technology. The combination of critically ill. Surveillance of saline bottle level is very
medical and engineering disciplines has revolutionized the important because when the bottle is emptied and the needle
modern medical practices. Traditional methods used for is not removed from the vein then the blood flows outward
health care are becoming outdated due to increase in into the bottle. In hospitals, the nurses or caretakers are
population. Innovative health monitoring systems are responsible for monitoring the saline bottle level. Mostly,
required with less human mediation/intervention which can due to negligence and any unusual condition, the exact
be available at low cost in rural as well as urban areas. timing of removing the needle from the patient's vein is
ATMega 328 Microcontroller &RF based saline monitoring ignored which causes a serious casualty and may lead to
system is a perfect example of such innovative health death as well. Furthermore, remote monitoring is a need to
management system. This system can be easily and readily provide telehealth services. To prevent the accident due to
installed in every hospital which will help out the nurses and the ignorance of caretakers and to provide remote
doctors for efficient monitoring of saline flow in the surveillance in telehealth services, we have proposed the
hospitals. cost-effective smart saline level monitoring device which
includes the combination of sensor and Internet of Things
Every automation system generally consist of two parts, (IoT) technologies. We have built this system by using load
transmitter and receiver part. In this proposed system there sensor and ultra-low power low cost ESP32 WiFi System on
are two RF Module used to transmit and receive the voltage Chip (SoC) microcontroller. The load sensor converts the
level changes when intravenous fluid level is below certain weight of the bottle to a specific voltage. The ESP32
limit. The system also consist of Arduino micro-controller microcontroller generates and publishes a specific message
based on the voltage received from the sensor. To publish

XXX-X-XXXX-XXXX-X/XX/$XX.00 ©20XX IEEE


and present the messages to the devices(e.g. smartphone,
tablet, laptop etc.) of subscribers like doctors, nurses or
caretakers, we have used MQTT-S publish/subscribe
protocol which runs over TCP. This proposed monitoring
system fulfills the reliable delivery of messages to the
subscribers which is very important for healthcare.

III. PROPOSED WORK


The implemented framework comprises of different
sensors and devices and they are interconnected by means
of remote correspondence modules. The sensors data is Load cells are designed to measure a specific force, and
been sent and received From nurse or doctor end utilizing ignore other forces being applied. The electrical signal
RF connectivity. This system is used to observe the output by the load cell is very small and requires specialized
condition of patient. The data can be viewed on LCD amplification. Load cells require a power source and
Module. The nurse can observe all the levels, or the range produce a very small voltage differential when under strain.
that is performed In order to read this signal, an amplifier or a board with a
high-precision analog-to-digital converter is required.
A. Block Diagram

Transmitter Section
C. Load cell amplifier

Receivrer Section This Load Cell Amplifier is a small breakout board for the
HX711 IC that allows you to easily read load cells to
measure weight. By connecting the amplifier to your
microcontroller you will be able to read the changes in the
resistance of the load cell and with some calibration you'll
be able to get very accurate weight measurements.

Rf module

B. Load Cell

An RF module (short for radio-frequency module) is a


(usually) small electronic device used to transmit and/or
receive radio signals between two devices. It is often and timely help that carried us throughout our
desirable to communicate with another device wirelessly endeavour and finally made a grand success.
This wireless communication may be accomplished
We also thank the staff of our electronics department for
through optical communication or through radio-frequency
all the cooperation and friendly treatment given to us
(RF) communication
during project. We are also thankful to our colleagues
and all those have extended the necessary help during
the course of our work.
IV. ACKNOWLEDGMENT
REFERENCES
We sincerely acknowledge with deep sense of • Shivam Gupta , Mandar Kulkarni, Vaishnavi
gratitude to our project guide Mrs. Pradnya Zode for Kulkarni B.E Electronics and Telecommunication
the guidance and encouragement they gave us for the Nashik ,Maharashtra, India-Smart saline
preparation of this project. Without her the project monitoring system using load cell and RF sensor.
would have been difficult. • Sumet Umchid, Pakkawat kongsboom, and Matuve
We are highly obliged to Dr. U. P. Waghe (Principal) Buttongdee-Design and Development of a
and Dr. P. T. Karule, H.O.D (Department of Monitoring system for Saline Administration.
Electronics Engineering) for their noble, spontaneous