CERTIFICATE OF CALIBRATION DATE OF ISSUE : 05 October 2023, ERTIFICATE NO: SST/SA/R/20231/373 ISSUED BY : SIRIM Calibration Sdn, Bhd. (Formerly known as SIRIM Standards Technology Sdn. Bhd.) PAGE 1 OF 2 PAGES (Company No, 199401006522 (292201-P)) —PPROVED SIGNATORIES — ene ‘APPROVED SIGNATORIES Jalan Beremban 15/12, Seksyen 15, 40200 Shah Alam,Selangor Darul Ehsan ‘Tel:+603 $510 9066 Fax:4603 5510 9077 Mohd Hashim Bin Effandi + Dermaga Oil & Gas Sdn. Bhd, Job No. : SA2023-5400-1 No 1, Jalan Tiara Sentral 1, Date Received : 03/10/2023 Kawasan Perindustrian Nilai Utama, 71800 Nilai, Negeri Sembilan ‘Attn: Mr Syafek nstrument : Digital Caliper Model No: CD-12"AX Manufacturer : Mitutoyo Serial No. : 0006973, Instrument Condition When Received : Physically in good condition Instrument Condition When Returned : Calibrated and test serviceable 2.Calibration due date requested by customer 53.The user should be aware that there are a number of factors that may caused this instrument to drift out of calibration before the specified calibration interval has expired, Environmental Condition: Average Temperature : (201) °C Average Relative Humidity; (521) % Calibration Date : 05 October 2023 Requested Cal.Due Date: 05 October 2024 Calibration Method : This instrament was ealibrated using the calibration procedures No. MSD0003 Rev. 20.0 Calibration Standard(s) Used : Instrument Type Serial No. Cal. Due Date: Cal. Cert. No. Traceability Caliper Checker 1034s 2210872024 SSTISAAR2023536 NMIM Pin Gauge 98.2435 13012024 SSTISAAR2023429 NMIM ation Sticker No.: SA-10-373 Measurement Uncertainty : 0.01 mm The uncertainty calculation is based on the ISO guide to the expression of uncertainty in measurement. Coverage Factor, k=2 Mod Hashim Bin Effandi The reported expanded measurement uncertainty s sated os the standard measurement uncertainty mulled by the coverane factor F such that he coverage probability corresponds to approximately 95%. This cetfcateis issued in acordance wih the laboratory accreditation requirements of skim Akreitasi Makmal Malaysia (SAMI) of Standards Malaysia. which iso signatory to the ILAC MRA. I provides traceability of measurement tothe SI system of units and/or ta uns of measurement realized atthe National Metrology Institute of Malaysia (NMIM) and other recognized national metrology institutes. CERTIFICATE OF CALIBRATION DATE OF ISSUE: 05 October 2023 CERTIFICATE NUMBER: SST/SA/R/202351373, PAGE 2 0F 2 PAGES, Instrument Digital Caliper Serial No. : 0006973 CALIBRATION RESULTS Errors (mmm) Max, Permissible Errors Description | Nominal Value (mm) a ‘minal Value (mm) |~Before Adjustment | _ After Adjustment (mm) 7) Full Surface Contact Error, J Range 0 0.00 NIA + 0.02 escola 20 0.00 NIA + 0.02 \craduation: 50 0.00 NIA + 0.02 CONE) 100 0.00 NIA = 0.03 150 0.00 NIA +003 200 0.00 NIA +003 300 0.00 NIA = 0.04 2) Repeatability, R 0.00 NIA NIA |3) Line Contact Error, L 0.00 + 0.005 Note: True Reading = Instrument Reading - Error Max. Permissible Errors Reference (s) : JIS-B-7507 : 2016 (Doe. Control No, : SD-03 Rev. 1.0) Calibrated by: fuslizam Bin Mat pbkeh End of Results The reported expanded measurement uncertainty is sated os the standard measirement uncertainty mulipled By the coverage Factor F such thatthe ‘coverage probably corresponds to approximately 95 %. This certificate issued in accordance with the lborotory accretion requirements of skim Akredtsi Makmal Malaysia (SAMM) of Standards Malaysia hich 8a signatory tthe IAC MIRA, It provides traceabilty of measurement to the Si system of units and/or to units of measurement realized at the [National Metrology Institute of Malaysia (NMIM) and other recognized national metrology institutes. CERTIFICATE OF CALIBRATION DATE OF ISSUE : 05 October 2023, CERTIFICATE NO: SST/SA/R/2023371 ISSUED BY : SIRIM Calibration Sdu, Bhd. (Formerty known as SIRIM Standards Technology Sd. Bhd.) PAGE 1 OF 2 PAGES (Company No, 199401006522 (292201-P)) Pe ‘APPROVED SIGNATORIES Jalan Beremban 15/12, Seksyen 15, 40200 Shah Alam,Selangor Darul Ehsan Tel:+603 $510 9066 Fax:+603 $510 9077 Mohd Hashim Bin Effandi + Detmaga Oil & Gas Sdn. Bhd, Job No. : SA2023-5400-2, No I, Jalan Tiara Sentral 1, ved : 03/10/2023, Kawasan Perindustrian Nilai Utama, 71800 Nila, Negeri Sembilan Attn: Mr Syafek Instrument: Depth Micrometer Model No.: N/A. Manufacturer Mitutoyo Serial No. : 115004 Instrument Condition When Received : Physically in good condition Instrument Condition When Returned : [Calibrated and test serviceable 2.Calibration due date requested by customer 5.The user should be awate tha there are a numberof factors that may caused this instrument to drift out of calibration before the specified calibration interval has expiced 4.This calibration were Not SAMM accredited Environmental Condition; Average Temperature : (20: 1) °C Average Relative Humidity: (52+ 1) % Calibration Date: 05 October 2023 Requested CalDue Date: 05 October 2024 Calibration Method : This instrument was calibrated using the calibration procedures No, MSD/0038 Rev. 3.0 Calibration Standard) Used : Instrument Type Serial No. Cal, Due Date: Cal, Cert. No. Traceability Standard Gauge Block 16096 21012023 SSTISAAR202H/11 — NMIM Calibration Sticker No.: SA-10-371 Measurement Uncertainty : 0.01 mm. The uncertainty calculation is based on the ISO guide to the expression of uncertainty in measurement, A “Approved Signatory Mohd Hashim Bin Effndi “The uncertainties are fora confidence probability of approximately 95% SIRIM SsT CERTIFICATE OF CALIBRATION DATE OF ISSUE: 05 October 2023 CERTIFICATE NUMBER: SST/SA/R/20231/371 PAGE2 OF 2 PAGES Instrument : Depth Micrometer Serial No. : 115004 CALIBRATION RESULTS Errors (mm) Max. Permissible mnge (mm) | Nominal Value (mm Range (mm) | N (em) | Before Adjustment | After Adjustment Errors (mm) 0-25 0.00 0.00 NA 0.003 2.50 0.00 NA + 0.003, Graduation: 5.10 0.00 NA 0,003 0.01 7.0 0.00 NA 0,003 1030 0.00 NA 0.003 12.90 0.00 NA + 0.003 15.00 0.00 NA + 0.003 17.60 0.00 NA + 0.003 20.20 0.00 NA +0.003 22.80 0.00 NA +0.003 25.00 0.00 NA «0.003 *~ Max. Permissible Errors Reference (s) BS 6468: 2008 (Doc. Control No. : SD-19 Rev. 1.0) Calibrated by: ‘The uncertainties are fora confidence probability of approximately 95% ‘SIRIM sau 0 CALIBRATION CERTIFICATE OF CALIBRATION DATE OF ISSUE : 09 October 2023, CERTIFICATE NO: SST/SAJR/20231/598 ISSUED BY : SIRIM Calibration Sda. Bhd. (Formerly known as SIRIM Standards Technology Sdn. Bhd.) PAGE 1 OF 4 PAGES (Company No, 199401006522 (292201-P)) SESS Petite oh) ‘APPROVED SIGNATORIES Jalan Beremban 15/12, Seksyen 15, 40200 Shah Alam,Selangor Darul Ehsan ‘Tel:+603 $510 9066 Fax:+603 5510 9077 Mohd Hashim Bin Effandi ‘Submitted by : Dermaga Oil & Gas Sdn. Bhd. Job No. : $A2023-5400-3, [No 1, Jalan Tiara Sentral 1, Date Received : 03/10/2023 Kawasan Perindustrian Nilai Utama, 71800 Nilai, Negeri Sembilan “Attn: Mr Syafek Instrument: Fecler Gauge Model No.: 184-3038 Manufacturer : Mitutoyo Identification No. : SA2023-1D-1168 Instrument Condition When Received : Physically in good condition Instrument Condition When Returned : | Calibrated and test serviceable 2.Calibration due date requested by customer 3.The user should be aware that there are a number of factors that may caused this instrument to drift out of ealibration before the specified calibration interval has expited. 4.*Denote out of tolerance Environmental Condition:- Average Temperature : (20+ 1) °C Average Relative Humidity: (581) % Calibration Date : 09 October 2023 Requested Cal.Due Date: 09 October 2024 Calibration Method This instrument was calibrated using the calibration procedures No.MSD/0012 Rev. 9.0 Calibration Standard(s) Used : Instrument Type Serial No. Cal, Due Date: Cal, Cert. No. ‘Traceability Syl¥ae Probe 2236190020 aioz/2024 SSTISAR20238/16 NMIM Standard Gauge Block 133102 g/10/2023 SSTISAMR2020H/S NMIM Calibration Sticker No. Measurement Uneertaint The uncert SA-10-598 £0,003 mm ty calculation is based on the ISO guide to the expression of uncertainty in measurement a ‘Approved Signatory Mod Hashim Bin Ean The reported expanded measurement uncertainty is Rated a he Mandard measurement uncertainty muliplied by the Coverage Jotor K such that the coverage probably corespands to approximately 95 % This certfat issued in occordance with the laboratory acretation requirements of Skim Akreditasi Mokmal Malaya (SAM) of Standards Matoysio hich sa signatory to the WAC MRA. tt provides waceablty of measurement to the System of units and/or to units of measurement realized at the [Nationa Metrology Institute of Malesia (NMIM) and other recognized national metroloay institutes. CERTIFICATE OF CALIBRATION DATE OF ISSU1: 09 October 2023, CERTIFICATE NUMBER : 5: /SA/R20231/598 PAGE2 OF 4 PAGES Instrument : Feeler Gauge Identification No. : SA2023-ID-1168 CALIBRATION RESULTS ‘Thickness Value (mm) ‘Chamber on Width Direction (mm) fominal Value (mm) Measurement Value Measurement Vatue | ‘Tolerance Min. Value [ Max. Value | _ Tolerance 0.050 0.048 0.019 | +0003 0.000 NA 0.060 0.060 0.060 | + 0,003 0.000 NIA 0.070 0.069 0.069 | + 0,008 0.001 NA 0.080 0.079 0.080 | + 0.008 0.001 NIA 0.090 0.089 0.090 | + 0.004 0.001 NIA 0.100 0.100 oor | + 0.008 0.009 NA 0.110 0.109 0.10 | + 0.005 0.001 NIA 0.120 0.121 0.12 | + 0.005 0.001 NA 0.130 0.131 0.132 | + 000s 0.002 NA Note: Tolerance Reference Document: JIS-B-7524:2008 (Clause S.1) (Doc. Control No.: $D-07 Re Calibrated By: The reported expanded mecsurement uncertainty s stated as the Standard measurement uncertainiy malpid by the coverage actor K wach Wat he ‘coverage probability corresponds to approximately 95 % This certificate is issued in accordance with te laboratory ocredttion requirements of Skim Akredtas Mokmal Molaysia (SAMM) of Standards Molaysio which isa signatory to the WAC MRA. It provides tacecblty of measurement to the System of units and/or to unis of meazurement realized ot the National Metrology Institute of Malaysia (NMIM) ond other recognized national metrology institutes. iawn ( (STANDARDS ) ) \ ee tnd) CERTIFICATE OF CALIBRATION DATE OF ISSUI: 09 October 2023 (CERTIFICATE NUMBER : SST/SA/R/20231/598 PAGE OF APAGES Instrument: Fecler Gauge entification No, : SA2023-ID-1168, CALIBRATION RESULTS ness Value (min) ‘Chamber on Width Direetion (mm) jominal Value (eum ‘Measurement Value in, Value | Max, Value | Tolerance | Measurement Value | Tolerance 0.140 oa oss | + 0.005 0.000 NA 0.150 ost o.sz | £0,005 0.001 NIA 0.200 0201 201 | + 0,005 0.001 NA 0.250 0251 0282 | + 0,00 0.002 N/A 0.300 0301 0301 | £0,005 0.001 NIA 0.350 0382 0354 | + 0.005 0.001 + 0.003, 0.400 0399 0399 | + 0.008 0.003 = 0.004 0.450 0451 0453 | + 0.008 0.002 = 0.004 0.500 0.498 oso | + 0.008 0.001 + 0.004 0.550 0548 0550 1.008 + 0,006 = 0.004 Note: Based on Reference Document: JIS-B-7524 : 2008 (Clause 5.1) (Doc. Control No. : SD-07 Re. 1.0, this leafs are out of its tolerance. However, its usage is decided by the customer based on their own specification/tolerance. Calibrated By: The reported expanded measurement uncertainty is sated os the Standard measurement uncertainty mulipled By he coverage Focor such thot the coverage probabil corresponds to approximately 95%. This ceria issued in accordance with the loborotory accredtation requirements of skim Akredtasi Makmal Malaysia (SAMM) of Standards Malesia which isa signatory to the WAC MRA, It provides traceability of measurement tothe SI system of units and/or to unts of measurement realized ot the National Metrology Institute of Malaysia (NMIM) and other recognized national metrology institutes CERTIFICATE OF CALIBRATION DATE OF ISSUI: 09 October 2023, (CERTIFICATE NUMBER : SST/SA/R/20234/598 PAGE 4OF 4PAGES Instrument : Fecler Gauge Identification No. : SA2023-1D-1168 CALIBRATION RESULTS ‘Thickness Value (rim) ‘Chamber on Width Direction (mm) Nominal Value (mm) Measurement Value Measurement Vatue | Tolerance in. Value | Max. Value | Tolerance 0.600 0,608 +0609 | + 0.008 0.004 + 0.004 0.650 0.647 0619 | + 0.008 0.001 + 0.004 0.700 0.699 o7o1 | + 0.010 0.008 + 0.005 0.750 0.750 o7s1 | «0.010 0.008 + 0,005 0.800 0.802 0803 | + 0.010 0.002 + 0,005 0.850 0.850 ogsi | £0010 + 0.006 + 0.005 0.900 0.897 0899 | + 0.010 +0017 + 0,005 0.950 0.982 0953 | +0010 0.010 + 0.005 1.000 1.002 1.007 | + 0.010 0.008 + 0,005 Note: Based on Reference Document: JIS-B-7524 : 2008 (Clause 5.1) (Doc. Control No. :SD-07 Rev. 1.0, this leafs are out of is tolerance. However, its usage is decided by the customer based on their own specification/tolerance. Calibrated By: The reported expanded measurement uncertainty s stated as the Standard measurement uncertainty mulled By the coverage Factor F such that the ‘coverage probability coresponds to approximately 5 % This certificate is ssued in accordance with te laboratory ocredltation requirements of Skim Akredtas Mokml Malesia (SAMM) of Standards Malaysia which sa signatory to the WAC MRA, It provides traceability of measurement to the Si system of units and/or to unts of measurement realized at the Notional Metrology Institute of Malaysia (NMIM) and other ecognized national metrology inetutes CERTIFICATE OF CALIBRATION DATE OF ISSUE : 04 October 2023, CERTIFICATE NO: SST/SA/R/20231/235 ISSUED BY : SIRIM Calibration Sdn, Bhd. (ormerly known as SIRIM Standards Technology Sdn. Bhd.) PA (Company No. 199401006522 (292201-P)) Lot 12, 18 & 20, Jalan Beremban 15/12, Seksyen 15, 40200 Shah Alam Selangor Darul Ehsan Tel:+603 $510 9066 Fax:+603 5510 9077 TOF2 PAGES ‘APPROVED SIGNATORIES Mohd Ami Bin Abd Aziz Dermaga Oil & Gas Sdn. Bhd, '8A2023-5400-4 No 1, Jalan Tiara Sentral 1, Date Received : 03/10/2023 Kawasan Perindustrian Nilai Utama, 71800 Nilai, Negeri Sembilan, Attn:Mr Syafek Instrument + Straight Bar Model No. N/A Manufacturer : N/A Serial No. : 39990 Instrument Condition When Received Physically in good condition Instrument Condition When Returned : | Calibrated and test serviceable 2.Calibration due date requested by customer 3h user should be aware that there are a number of factors that may caused this instrument to drift out of calibration before the specified calibration interval has expired. Environmental Condition: Average Temperature : (20+ 1)°C Average Relative Humidity: (52+ 1) % Calibration Date : 04 October 2023, Requested Cal,Due Date: 04 October 2024 Calibration Method : This instrument was calibrated using the calibration procedures No. MSD/0021 Rev. 5.0 Calibration Standard(s) Used : Instrument Type ‘Serial No. Cal. Due Date: Cal. Cert. No. ‘Traceability Sylvac Probe 22364190020 1602/2024 SSTISAMRI20238/16 — NMIM Calibration Sticker No. SA-10-235 Measurement Uncertainty : 3 ym ‘The uncertainty calculation is based on the ISO guide tothe expression of uncertainty in measurement, sk Approved Signatory Mohd Amri Bin Abd Aziz Coverage Factor, k=2 The reported expanded measurement uncertainty is Hated os the Mtandard meazurement uncertainty muliplied by the Coverage Joctor K such hat he ‘coverage probably corresponds to approximately 95% This cerca is sued in occordance with the laboratory accreditation requirements of Skim Aredtas! Matmal Molaysa (SAMA) of Standards Malaysia hich isa signatory to the WAC MRA. It provides waceabllty of measurement to the SI system of units and/or to units of measurement realized at the National Metrology Isttuteof Malysia (NMI) and other recognized national metrology institutes. : emt (Graney ») ) SIRIM SAMI 088 CALIBRATION CERTIFICATE OF CALIBRATION DATE OF ISSUE: 04 October 2023 CERTIFICATE NUMBER: SSTISA/R/20234/235 PAGE2 OF PAGES Instrument: Straight Bar Serial No.: 39990 CALIBRATION RESULTS Straight Bar Length: 500 mm Description Calibrated Value (yum) Tolerance (ym) Straighiness Top 37 140 Bottom 38 140 Note : Tolerance Reference (s) : JIS-B-7514:1997( Document Control No, SD-193 Rev. 0.0). This Straight Edge complies with Grade B. Calibrated by: Za pa Mohd Hashim Bin Effandt The reported expanded measurement uncertainty ted as the standard measurement uncertainty muliplied by the Coverage Fotor such That the coverage probability coresponds o approximately 95 % This certjcate fs tssued in occordance with the laboratory accreditation requirements of Skim Akredtas! Makmal Malaysia (SAMM) of Standards Malaysia hich Iso signatory to the WAC MRA. It provides taceabllty of measurement to the SI system of units and/or to units of measurement realized at the National Metrology Insitute of Malesia (NMI) and other recognized national metrology institute.

You might also like